Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Infect Control Hosp Epidemiol ; 45(5): 583-589, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38234192

RESUMO

BACKGROUND: Transient acquisition of methicillin-resistant Staphylococcus aureus (MRSA) on healthcare personnel (HCP) gloves and gowns following patient care has been examined. However, the potential for transmission to the subsequent patient has not been studied. We explored the frequency of MRSA transmission from patient to HCP, and then in separate encounters from contaminated HCP gloves and gowns to a subsequent simulated patient as well as the factors associated with these 2 transmission pathways. METHODS: We conducted a prospective cohort study with 2 parts. In objective 1, we studied MRSA transmission from random MRSA-positive patients to HCP gloves and gowns after specific routine patient care activities. In objective 2, we simulated subsequent transmission from random HCP gloves and gowns without hand hygiene to the next patient using a manikin proxy. RESULTS: For the first objective, among 98 MRSA-positive patients with 333 randomly selected individual patient-HCP interactions, HCP gloves or gowns were contaminated in 54 interactions (16.2%). In a multivariable analysis, performing endotracheal tube care had the greatest odds of glove or gown contamination (OR, 4.06; 95% CI, 1.3-12.6 relative to physical examination). For the second objective, after 147 simulated HCP-patient interactions, the subsequent transmission of MRSA to the manikin proxy occurred 15 times (10.2%). CONCLUSION: After caring for a patient with MRSA, contamination of HCP gloves and gown and transmission to subsequent patients following HCP-patient interactions occurs frequently if contact precautions are not used. Proper infection control practices, including the use of gloves and gown, can prevent this potential subsequent transmission.


Assuntos
Infecção Hospitalar , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Humanos , Infecção Hospitalar/prevenção & controle , Luvas Protetoras , Estudos Prospectivos , Pessoal de Saúde , Controle de Infecções , Infecções Estafilocócicas/prevenção & controle
2.
Infect Control Hosp Epidemiol ; 44(4): 578-588, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36177884

RESUMO

BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA) is a significant nosocomial pathogen in the ICU. MRSA contamination of healthcare personnel (HCP) gloves and gowns after providing care to patients with MRSA occurs at a rate of 14%-16% in the ICU setting. Little is known about whether the MRSA isolates identified on HCP gown and gloves following patient care activities are the same as MRSA isolates identified as colonizing or infecting the patient. METHODS: From a multisite cohort of 388 independent patient MRSA isolates and their corresponding HCP gown and glove isolates, we selected 91 isolates pairs using a probability to proportion size (PPS) sampling method. To determine whether the patient and HCP gown or gloves isolates were genetically similar, we used 5 comparative genomic typing methods: phylogenetic analysis, spa typing, multilocus sequence typing (MLST), large-scale BLAST score ratio (LSBSR), and single-nucleotide variant (SNV) analysis. RESULTS: We identified that 56 (61.5%) of isolate pairs were genetically similar at least by 4 of the methods. Comparably, the spa typing and the LSBSR analyses revealed that >75% of the examined isolate pairs were concordant, with the thresholds established for each analysis. CONCLUSIONS: Many of the patient MRSA isolates were genetically similar to those on the HCP gown or gloves following a patient care activity. This finding indicates that the patient is often the primary source of the MRSA isolates transmitted to the HCP, which can potentially be spread to other patients or hospital settings through HCP vectors. These results have important implications because they provide additional evidence for hospitals considering ending the use of contact precautions (gloves and gowns) for MRSA patients.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Humanos , Tipagem de Sequências Multilocus , Filogenia , Pessoal de Saúde
3.
Infect Control Hosp Epidemiol ; 42(6): 760-762, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33749575

RESUMO

In this cross-sectional study, we examined the relationship between resident level of care in the nursing home and colonization with resistant gram-negative bacteria. Residential-care residents were more likely to be colonized with resistant gram-negative bacteria than were postacute care residents (odds ratio, 2.3; 95% confidence interval, 1.40-3.80; P < .001).


Assuntos
Infecções por Bactérias Gram-Negativas , Estudos Transversais , Bactérias Gram-Negativas , Infecções por Bactérias Gram-Negativas/epidemiologia , Humanos , Casas de Saúde , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA