Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Cancer Res Clin Oncol ; 150(9): 421, 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39287633

RESUMO

PURPOSE: Cancer-associated fibroblasts (CAFs) are one of the most critical cells in the tumor environment, with crucial roles in cancer progression and metastasis. Due to Field-Effect phenomena (also called field cancerization), the adjacent cavity side area of the margin is histologically normal, but it has been entered into neoplastic transformation due to MCT4 and MCT1 pathways activated by H2O2/ROS oxidative stress agents secreted by CAF in adjacent tumor bed microenvironment. This paper specifically focused on the role of cancer-associated fibroblast in breast tumor beds and its correlation with the presence of scattered cancer cells or onco-protein-activated cells (may be high risk but not completely transformed cancer cells) in the cavity side margins. METHODS: In this study, the glycolytic behavior of non-tumoral cavity side margins was examined using carbon nanotube-based electrochemical biosensors integrated into a cancer diagnostic probe. This method enabled the detection of CAF accumulation sites in non-cancerous neighboring tissues of tumors, with a correlation to CAF concentration. Subsequently, RT-PCR, fluorescent, histopathological, and invasion assays were conducted on hyperglycolytic lesions to explore any correlation between the abundance of CAFs and the electrochemical responses of the non-cancerous tissues surrounding the tumor, as well as their neoplastic potential. RESULTS: We observed overexpression of cancer-associated transcriptomes as well as the presence and hyperactivation of CAFs in cavity-side regions in which glycolytic metabolism was recorded, independent of the histopathological state of the lesion. At mean 70.4%, 66.7%, 70.4%, and 44.5% increments were observed in GLUT-1, MMP-2, N-cadherin, and MMP-9 transcriptomes by highly glycolytic but histologically cancer-free expression samples in comparison with negative controls (histologically non-cancer lesions with low glycolytic behavior). CONCLUSION: The presence of CAFs is correlated with the presence of high glycolytic metabolism in the cavity margin lesion, high ROS level in the lesion, and finally aggressive cancer-associated proteins (such as MMP2, …) in the margin while these metabolomes, molecules, and proteins are absent in the margins with negatively scored CDP response and low ROS level. So, it seems that when we observe CAFs in glycolytic lesions with high ROS levels, some high-risk epithelial breast cells may exist while no histological trace of cancer cells was observed. Further research on CAFs could provide valuable insights into the local recurrence of malignant breast diseases. Hence, real-time sensors can be used to detect and investigate CAFs in the non-tumoral regions surrounding tumors in cancer patients, potentially aiding in the prevention of cancer recurrence.


Assuntos
Neoplasias da Mama , Fibroblastos Associados a Câncer , Humanos , Feminino , Fibroblastos Associados a Câncer/metabolismo , Fibroblastos Associados a Câncer/patologia , Neoplasias da Mama/patologia , Neoplasias da Mama/metabolismo , Neoplasias da Mama/genética , Células Epiteliais/metabolismo , Células Epiteliais/patologia , Microambiente Tumoral , Glicólise , Margens de Excisão
2.
Cancer Med ; 11(7): 1630-1645, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35224879

RESUMO

BACKGROUND: Cancer diagnostic probe (CDP) had been developed to detect involved breast cavity side margins in real-time (Miripour et al. Bioeng Transl Med. e10236.). Here, we presented the results of the in vivo human model CDP studies on non-neoadjuvant cases. METHODS: This study is a prospective, blind comparison to a gold standard, and the medical group recruited patients. CDP and frozen data were achieved before the permanent pathology experiment. The main outcome of the study is surgical margin status. From November 2018 to April 2020, 202 patients were registered, and 188 were assigned for the study. Breast-conserving surgery at any age or gender, re-surgery due to re-currency, or involved margins are acceptable. Patients must be non-neoadjuvant. The reliability of CDP scoring had been evaluated by the pathology of the scored IMs. Then, three models of the study were designed to compare CDP with the frozen sections. Receiver operating characteristic (ROC) curves and AUC were measured based on the permanent postoperative pathology gold standard. RESULTS: A matched clinical diagnostic categorization between the pathological results of the tested IMs and response peaks of CDP on 113 cases, was reported (sensitivity = 97%, specificity = 89.3%, accuracy = 92%, positive predictive value (PPV) = 84.2%, and negative predictive value (NPV) = 98%). Study A showed the independent ability of CDP for IM scoring (sensitivity = 80%, specificity = 90%, accuracy = 90%, PPV = 22.2%, and NPV = 99.2%). Study B showed the complementary role of CDP to cover the missed lesions of frozen sections (sensitivity = 93.8%, specificity = 91%, accuracy = 91%, PPV = 55.6%, and NPV = 99.2%). Study C showed the ability of CDP in helping the pathologist to reduce his/her frozen miss judgment (specificity = 92%, accuracy = 93%, PPV = 42.1%, and NPV = 100%). Results were reported based on the post-surgical permanent pathology gold standard. CONCLUSION: CDP scoring ability in intra-operative margin detection was verified on non-neoadjuvant breast cancer patients. Non-invasive real-time diagnosis of IMs with pathological values may make CDP a distinct tool with handheld equipment to increase the prognosis of breast cancer patients.


Assuntos
Neoplasias da Mama , Margens de Excisão , Feminino , Humanos , Masculino , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Glicólise , Hipóxia , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Bioeng Transl Med ; 7(1): e10236, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35079624

RESUMO

For most people, the first step in treatment is to take out the tumor (surgery), so precise and fast diagnosis of any sign of high-risk and neoplastic cells, especially in surgical cavity margins, is significant. The frozen pathology method is the conventional standard of intraoperative diagnosis, but the low number of slides prepared from non-fixed tissues prevents us from achieving a perfect diagnosis. Although many improvements in intraoperative margin detection were achieved, still real-time detection of neoplastic lesions is crucial to improving diagnostic quality. Functionalized carbon nanotubes grown on the electrode needles lively and selectively determine the H2O2 released from cancer/atypical cells through reverse Warburg effect and hypoxia assisted glycolysis pathways in a quantitative electrochemical manner. The study was carried out on cell lines, 57 in vivo mice models with breast cancer, and 258 fresh in vitro samples of breast cancer tumors. A real-time electrotechnical system, named cancer diagnostic probe (CDP) (US Patent Pub. No.: US 2018/02991 A1, US 2021/0007638 A1, and US 2021/0022650 A1 [publications], and US 10,786,188 B1 [granted]), has been developed to find pre-neoplastic/neoplastic cells in vivo in a quantitative electrochemical manner by tracing hypoxia glycolysis byproducts. Matched pathological evaluations with response peaks of CDP were found based on the presence of neoplasia (from atypia to invasive carcinoma) in live breast tissues. The ability of CDP to find neoplastic lesions in mice models in vivo and fresh breast tumors in vitro was verified with sensitivity and specificity of 95% and 97%, respectively. The system may help a surgeon assistant system for usage in the operating room after passing many trials and standard examinations in the future.

4.
Biosci Rep ; 40(6)2020 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-32436938

RESUMO

Lipid synthesis is the recently found metabolism of cancer cells after their metastasis to lymph nodes (LNs). Carbonic acid is the main byproduct of the lipid metabolism in such cells which resulted in acidification of LN ambient. Hence, calibrated pH sensing could be a diagnostic method to find involved LNs. Here, we designed a simple pH sensing method by a syringe containing sterile PBS and embedded by litmus paper to intraoperatively check the pH of LN fluid. Injected phosphate buffer saline (PBS) would homogenize the LN fluid and litmus needle would detect the pH of the LN. We presented an experimental pathological calibration for the pH values in correlation with cancerous states of the LNs. This system named metabolism based metastatic lymph diagnoser (MMLD) could be a real-time noninvasive tool for precise and fast diagnosis of involved LNs.


Assuntos
Neoplasias da Mama/diagnóstico , Lipogênese , Linfonodo Sentinela/metabolismo , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Concentração de Íons de Hidrogênio , Metástase Linfática , Valor Preditivo dos Testes , Linfonodo Sentinela/patologia , Linfonodo Sentinela/cirurgia , Biópsia de Linfonodo Sentinela
5.
Biosens Bioelectron ; 161: 112209, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32442106

RESUMO

An electrochemical biopsy probe was designed and fabricated to detect cancer tumors under the sonography guide without the need for any sample dissection (biopsy). The system was based on recording the hypoxic function of cancer tumors by Multi-wall carbon nanotubes (MWCNTs) sensing agents had been decorated on the tip of the needle electrodes by an electrostatic deposition method. This system named BGP successfully distinct 4T1 and MC4L2 breast tumors from normal lesions. It also diagnosed the treated tumors from vital ones. BGP as a clinically useful biosensor would detect the cancerous probability of any suspicious breast mass without any sample excision. Also, it can present a profile from neoplastic states of different regions of a tumor. This ability would make ensure for the radiologist to do biopsy or not, especially in the cases which are suspicious between BIRADS III and IVa. This would not only shed new light in detecting breast cancer tumors without biopsy (applied in radiological BIRADS classifications) but also evaluate the therapeutic effects on cancer tumors after chemotherapy/radiotherapy therapies without complicated and expensive scanning.


Assuntos
Técnicas Biossensoriais , Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Nanotubos de Carbono/química , Biópsia com Agulha de Grande Calibre/métodos , Mama/patologia , Neoplasias da Mama/patologia , Feminino , Humanos , Radiologia Intervencionista , Ultrassonografia
6.
Nanoscale ; 12(43): 22129-22139, 2020 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-33119020

RESUMO

Herein, we present a new design on the Single Needle Electrochemical Therapy (SNEChT) method by introducing some major improvements, including a nanoporous platinum electrode, tunable in situ anode size that depends on the width and location of the tumor, and the capability of measuring the efficacy of therapy based in intra-therapeutic impedance recording by the same EChT needle. It could have significant implications in optimizing EChT operative conditions. The nanoporous Pt electrode increased the interactive surface with a tumor, and produced a higher amount of current with lower stimulating DC voltage. The tunable anode size prevents the over-acidification of treated or non-desired lesions. Hence, this feature reduced the over distribution of tissue. Monitoring the impedance during the therapy clearly informs us about the local destruction of the tumor in each location. Thus, we can be informed about the threshold of tissue acidosis with the lowest electrical stimulation. The insertion of one needle with a tunable anode length for both precise therapy and impedance-based intra-therapeutic monitoring will shed new light on the applications of EChT.


Assuntos
Terapia por Estimulação Elétrica , Nanoporos , Neoplasias , Impedância Elétrica , Eletroquímica , Eletrodos , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Platina
7.
Biosens Bioelectron ; 165: 112435, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32729548

RESUMO

COVID-19 is the shocking viral pandemics of this year which affected the health, economy, communications, and all aspects of social activities all over the world. Early diagnosis of this viral disease is very important since it can prevent lots of mortalities and care consumption. The functional similarities between COVID-19 and COVID-2 in inducing acute respiratory syndrome lightened our mind to find a diagnostic mechanism based on early traces of mitochondrial ROS overproduction as lung cells' dysfunctions induced by the virus. We designed a simple electrochemical sensor to selectively detect the intensity of ROS in the sputum sample (with a volume of less than 500 µl). Comparing the results of the sensor with clinical diagnostics of more than 140 normal and involved cases resulted in a response calibration with accuracy and sensitivity both 97%. Testing the sensor in more than 4 hospitals shed promising lights in ROS based real-time tracing of COVID-19 from the sputum sample.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas Biossensoriais/métodos , Infecções por Coronavirus/diagnóstico , Técnicas Eletroquímicas/métodos , Pneumonia Viral/diagnóstico , Espécies Reativas de Oxigênio/análise , Escarro/virologia , Adulto , Idoso , Técnicas Biossensoriais/instrumentação , COVID-19 , Infecções por Coronavirus/virologia , Diagnóstico Precoce , Técnicas Eletroquímicas/instrumentação , Desenho de Equipamento , Feminino , Humanos , Pulmão/química , Pulmão/virologia , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/virologia , SARS-CoV-2 , Sensibilidade e Especificidade , Escarro/química , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA