Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Cell Biochem Funct ; 42(3): e4009, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38597217

RESUMO

Atypical chemokine receptor 4 (ACKR4), also known as CCX-CKR, is a member of the chemokine receptor family that lacks typical G protein signaling activity. Instead, ACKR4 functions as a scavenger receptor that can bind and internalize a wide range of chemokines, influencing their availability and activity in the body. ACKR4 is involved in various physiological processes, such as immune cell trafficking and the development of thymus, spleen, and lymph nodes. Moreover, ACKR4 has been implicated in several pathological conditions, including cancer, heart and lung diseases. In cancer, ACKR4 plays a complex role, acting as a tumor suppressor or promoter depending on the type of cancer and the stage of the disease. For instance, ACKR4 may inhibit the growth and metastasis of breast cancer, but it may also promote the progression of hepatocellular carcinoma and gastric cancer. In inflammatory situations, ACKR4 has been found to modulate the recruitment and activation of immune cells, contributing to the pathogenesis of diseases such as myocardial infraction and pulmonary sarcoidosis. The study of ACKR4 is still ongoing, and further research is needed to fully understand its role in different physiological and pathological contexts. Nonetheless, ACKR4 represents a promising target for the development of novel therapeutic strategies for various diseases.


Assuntos
Neoplasias da Mama , Transdução de Sinais , Feminino , Humanos
2.
Sensors (Basel) ; 21(20)2021 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-34696109

RESUMO

In Australia, droughts are recurring events that tremendously affect environmental, agricultural and socio-economic activities. Southern Queensland is one of the most drought-prone regions in Australia. Consequently, a comprehensive drought vulnerability mapping is essential to generate a drought vulnerability map that can help develop and implement drought mitigation strategies. The study aimed to prepare a comprehensive drought vulnerability map that combines drought categories using geospatial techniques and to assess the spatial extent of the vulnerability of droughts in southern Queensland. A total of 14 drought-influencing criteria were selected for three drought categories, specifically, meteorological, hydrological and agricultural. The specific criteria spatial layers were prepared and weighted using the fuzzy analytical hierarchy process. Individual categories of drought vulnerability maps were prepared from their specific indices. Finally, the overall drought vulnerability map was generated by combining the indices using spatial analysis. Results revealed that approximately 79.60% of the southern Queensland region is moderately to extremely vulnerable to drought. The findings of this study were validated successfully through the receiver operating characteristics curve (ROC) and the area under the curve (AUC) approach using previous historical drought records. Results can be helpful for decision makers to develop and apply proactive drought mitigation strategies.


Assuntos
Agricultura , Secas , Austrália , Hidrologia , Queensland
3.
Sensors (Basel) ; 19(6)2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30875881

RESUMO

Floods are common natural disasters worldwide, frequently causing loss of lives and huge economic and environmental damages. A spatial vulnerability mapping approach incorporating multi-criteria at the local scale is essential for deriving detailed vulnerability information for supporting flood mitigation strategies. This study developed a spatial multi-criteria-integrated approach of flood vulnerability mapping by using geospatial techniques at the local scale. The developed approach was applied on Kalapara Upazila in Bangladesh. This study incorporated 16 relevant criteria under three vulnerability components: physical vulnerability, social vulnerability and coping capacity. Criteria were converted into spatial layers, weighted and standardised to support the analytic hierarchy process. Individual vulnerability component maps were created using a weighted overlay technique, and then final vulnerability maps were produced from them. The spatial extents and levels of vulnerability were successfully identified from the produced maps. Results showed that the areas located within the eastern and south-western portions of the study area are highly vulnerable to floods due to low elevation, closeness to the active channel and more social components than other parts. However, with the integrated coping capacity, western and south-western parts are highly vulnerable because the eastern part demonstrated particularly high coping capacity compared with other parts. The approach provided was validated by qualitative judgement acquired from the field. The findings suggested the capability of this approach to assess the spatial vulnerability of flood effects in flood-affected areas for developing effective mitigation plans and strategies.

4.
Sensors (Basel) ; 18(3)2018 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-29495561

RESUMO

Macroporous silicon was prepared through an anodization process; the prepared samples showed an average pore size ranging from 4 to 6 microns, and the depth of the pores in the silicon wafer was approximately 80 microns. The prepared samples were tested for hydrogen peroxide (H2O2) concentrations, which can be used for industrial and environmental sensing applications. The selected H2O2 concentration covered a wide range from 10 to 5000 µM. The tested samples showed a linear response through the tested H2O2 concentrations with a sensitivity of 0.55 µA µM-1∙cm-2 and lower detection limits of 4.35 µM at an operating voltage of 5 V. Furthermore, the electrode exhibited a rapid response with a response time of ca. two seconds. Furthermore, the prepared sensor showed a reasonable stability over a one-month time period.

5.
Lasers Med Sci ; 32(9): 2089-2095, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28967036

RESUMO

The study of the effects of low-level laser (LLL) radiation on blood is important for elucidating the mechanisms behind the interaction of LLL radiation and biologic tissues. Different therapy methods that involve blood irradiation have been developed and used for clinical purposes with beneficial effects. The aim of this study was to compare the effects of different irradiation protocols using a diode-pumped solid-state LLL (λ = 405 nm) on samples of human blood by measuring the erythrocyte sedimentation rate (ESR). Human blood samples were obtained through venipuncture into tubes containing EDTA as an anticoagulant. Every sample was divided into two equal aliquots to be used as an irradiated sample and a non-irradiated control sample. The irradiated aliquot was subjected to a laser beam with a wavelength of 405 nm and an energy density of 72 J/cm2. The radiation source had a fixed irradiance of 30 mW/cm2. The ESR change was observed for three different experimental protocols: irradiated whole blood, irradiated red blood cells (RBCs) samples re-suspended in non-irradiated blood plasma, and non-irradiated RBCs re-suspended in irradiated blood plasma. The ESR values were measured after laser irradiation and compared with the non-irradiated control samples. Irradiated blood plasma in which non-radiated RBCs were re-suspended was found to result in the largest ESR decrease for healthy human RBCs, 51%, when compared with RBCs re-suspended in non-irradiated blood plasma. The decrease in ESR induced by LLL irradiation of the plasma alone was likely related to changes in the plasma composition and an increase in the erythrocyte zeta potential upon re-suspension of the RBCs in the irradiated blood plasma.


Assuntos
Eritrócitos/efeitos da radiação , Lasers de Estado Sólido , Adulto , Sedimentação Sanguínea/efeitos da radiação , Forma Celular/efeitos da radiação , Relação Dose-Resposta à Radiação , Contagem de Eritrócitos , Volume de Eritrócitos/efeitos da radiação , Hematócrito , Humanos , Plasma/efeitos da radiação
6.
Lasers Med Sci ; 32(2): 405-411, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28044209

RESUMO

Low-level laser irradiation (LLLI) has various effects on cultured human lymphocytes in vitro, but little is known about such effects in whole blood. This study investigated whether LLLI affected lymphocyte count in human whole blood in vitro. A total number of 130 blood samples were collected from apparently healthy adult patients through venipuncture into tubes containing EDTA. Each sample was divided into two equal aliquots to be used as a non-irradiated control sample and an irradiated sample. The irradiated aliquot was subjected to laser wavelengths of 405, 589, and 780 nm with different fluences of 36, 54, 72, and 90 J/cm2, at a fixed irradiance of 30 mW/cm2. A paired student t test was used to compare between non-irradiated and irradiated samples. The lymphocyte counts were measured using a computerized hematology analyzer and showed a significant (P < 0.02) maximum increase (1.6%) at a fluence of 72 J/cm2 when compared with non-irradiated samples. This increase in lymphocyte count upon irradiation was confirmed by flow cytometry. At a wavelength of 589 nm and fluence of 72 J/cm2, irradiation of whole blood samples showed a significant increase in CD45 lymphocytes and natural killer (NK) (CD16, CD56) cells, but no significant changes in CD3 T lymphocytes, T-suppressor (CD3, CD8) cells, T-helper (CD3, CD4) cells, and CD19 B lymphocytes when compared with their non-irradiated counterparts. Our results clearly demonstrate that NK cell count is altered by irradiation, which ultimately affects the whole lymphocyte count significantly.


Assuntos
Terapia com Luz de Baixa Intensidade , Linfócitos/efeitos da radiação , Adulto , Relação Dose-Resposta à Radiação , Feminino , Humanos , Contagem de Linfócitos , Subpopulações de Linfócitos/efeitos da radiação , Masculino
7.
Lasers Med Sci ; 31(6): 1195-201, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27250712

RESUMO

This study is designed to investigate in vitro low-level laser (LLL) effects on rheological parameter, erythrocyte sedimentation rate (ESR), of human blood. The interaction mechanism between LLL radiation and blood is unclear. Therefore, research addresses the effects of LLL irradiation on human blood and this is essential to understanding how laser radiation interacts with biological cells and tissues. The blood samples were collected through venipuncture into EDTA-containing tubes as an anticoagulant. Each sample was divided into two equal aliquots to be used as a non-irradiated sample (control) and an irradiated sample. The aliquot was subjected to doses of 36, 54, 72 and 90 J/cm(2) with wavelengths of 405, 589 and 780 nm, with a radiation source at a fixed power density of 30 mW/cm(2). The ESR and red blood cell count and volume are measured after laser irradiation and compared with the non-irradiated samples. The maximum reduction in ESR is observed with radiation dose 72 J/cm(2) delivered with a 405-nm wavelength laser beam. Moreover, no hemolysis is observed under these irradiation conditions. In a separate protocol, ESR of separated RBCs re-suspended in irradiated plasma (7.6 ± 2.3 mm/h) is found to be significantly lower (by 51 %) than their counterpart re-suspended in non-irradiated plasma (15.0 ± 3.7 mm/h). These results indicate that ESR reduction is mainly due to the effects of LLL on the plasma composition that ultimately affect whole blood ESR.


Assuntos
Sedimentação Sanguínea/efeitos da radiação , Eritrócitos/efeitos da radiação , Hemólise/efeitos da radiação , Terapia com Luz de Baixa Intensidade , Humanos
8.
Sensors (Basel) ; 16(6)2016 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-27338381

RESUMO

In this study, porous silicon (PSi) was prepared and tested as an extended gate field-effect transistor (EGFET) for pH sensing. The prepared PSi has pore sizes in the range of 500 to 750 nm with a depth of approximately 42 µm. The results of testing PSi for hydrogen ion sensing in different pH buffer solutions reveal that the PSi has a sensitivity value of 66 mV/pH that is considered a super Nernstian value. The sensor considers stability to be in the pH range of 2 to 12. The hysteresis values of the prepared PSi sensor were approximately 8.2 and 10.5 mV in the low and high pH loop, respectively. The result of this study reveals a promising application of PSi in the field for detecting hydrogen ions in different solutions.

9.
J Ultrasound ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38324099

RESUMO

PURPOSE: Graphene-polymer nanocomposites significantly impact dental filler and antibacterial applications. The study aims to overcome some problems dental filers present and improve their properties and antibacterial activity. Synthesis graphene oxide (GO) and poly (methyl methacrylate) (PMMA) were used to reinforce two types of commercial hybrid/nano-dental fillings. METHODS: Developed acoustic-solution-sonication-casting methods were applied to fabricate the new graphene-polymer-dental filler nanocomposites. The structure, morphology, rheological and mechanical properties, and antibacterial of the newly fabricated filling-PMMA/ GO nanocomposites were investigated. RESULTS: Fourier transform infrared (FTIR) showed a significant interaction between the filling and the additional materials. The X-ray diffraction (XRD) analysis revealed a considerable change in crystalline behavior. Optical microscope (OM) with field emission scanning electron microscopy (FESEM) pictures demonstrated a substantial change in the morphology of the samples with a homogeneous and fine dispersion of the nanomaterials in the filler matrix. Multi-frequency ultrasound mechanical properties measured the ultrasonic velocity, absorption coefficient, compressibility, bulk modulus, and other mechanical properties that notably enhanced after GO contributed up to 325% of the ultrasonic absorption coefficient compared with hybrid/nano-fillers. Rheological properties were measured as viscosity, absorption coefficient, and specific viscosity, which significantly improved after adding PMMA and incorporating GO up to 57% of the viscosity, compared with hybrid/nano-fillers. The inhibition zone of moth bacteria, such as Enterococcus faecalis and E. staph bacteria, improved after the contribution of GO nanosheets up to 46%. CONCLUSION: Nanofillers nanocomposites presented better properties and inhabitances zone diameter of antibacterial.

10.
Sci Rep ; 14(1): 11977, 2024 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-38796531

RESUMO

The preoperative diagnosis of brain tumors is important for therapeutic planning as it contributes to the tumors' prognosis. In the last few years, the development in the field of artificial intelligence and machine learning has contributed greatly to the medical area, especially the diagnosis of the grades of brain tumors through radiological images and magnetic resonance images. Due to the complexity of tumor descriptors in medical images, assessing the accurate grade of glioma is a major challenge for physicians. We have proposed a new classification system for glioma grading by integrating novel MRI features with an ensemble learning method, called Ensemble Learning based on Adaptive Power Mean Combiner (EL-APMC). We evaluate and compare the performance of the EL-APMC algorithm with twenty-one classifier models that represent state-of-the-art machine learning algorithms. Results show that the EL-APMC algorithm achieved the best performance in terms of classification accuracy (88.73%) and F1-score (93.12%) over the MRI Brain Tumor dataset called BRATS2015. In addition, we showed that the differences in classification results among twenty-two classifier models have statistical significance. We believe that the EL-APMC algorithm is an effective method for the classification in case of small-size datasets, which are common cases in medical fields. The proposed method provides an effective system for the classification of glioma with high reliability and accurate clinical findings.


Assuntos
Algoritmos , Neoplasias Encefálicas , Glioma , Aprendizado de Máquina , Imageamento por Ressonância Magnética , Gradação de Tumores , Humanos , Glioma/diagnóstico por imagem , Glioma/classificação , Glioma/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/classificação , Neoplasias Encefálicas/patologia
11.
ACS Synth Biol ; 13(6): 1600-1620, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38842483

RESUMO

Antimicrobial resistance (AMR) poses a critical global One Health concern, ensuing from unintentional and continuous exposure to antibiotics, as well as challenges in accurate contagion diagnostics. Addressing AMR requires a strategic approach that emphasizes early stage prevention through screening in clinical, environmental, farming, and livestock settings to identify nonvulnerable antimicrobial agents and the associated genes. Conventional AMR diagnostics, like antibiotic susceptibility testing, possess drawbacks, including high costs, time-consuming processes, and significant manpower requirements, underscoring the need for intelligent, prompt, and on-site diagnostic techniques. Nanoenabled artificial intelligence (AI)-supported smart optical biosensors present a potential solution by facilitating rapid point-of-care AMR detection with real-time, sensitive, and portable capabilities. This Review comprehensively explores various types of optical nanobiosensors, such as surface plasmon resonance sensors, whispering-gallery mode sensors, optical coherence tomography, interference reflection imaging sensors, surface-enhanced Raman spectroscopy, fluorescence spectroscopy, microring resonance sensors, and optical tweezer biosensors, for AMR diagnostics. By harnessing the unique advantages of these nanoenabled smart biosensors, a revolutionary paradigm shift in AMR diagnostics can be achieved, characterized by rapid results, high sensitivity, portability, and integration with Internet-of-Things (IoT) technologies. Moreover, nanoenabled optical biosensors enable personalized monitoring and on-site detection, significantly reducing turnaround time and eliminating the human resources needed for sample preservation and transportation. Their potential for holistic environmental surveillance further enhances monitoring capabilities in diverse settings, leading to improved modern-age healthcare practices and more effective management of antimicrobial treatments. Embracing these advanced diagnostic tools promises to bolster global healthcare capacity to combat AMR and safeguard One Health.


Assuntos
Inteligência Artificial , Técnicas Biossensoriais , Nanoestruturas , Técnicas Biossensoriais/métodos , Nanoestruturas/química , Humanos , Antibacterianos/farmacologia , Farmacorresistência Bacteriana/genética
12.
Nanomaterials (Basel) ; 13(2)2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36678106

RESUMO

The applications of silver nanowires (AgNWs) are clearly relevant to their purity and morphology. Therefore, the synthesis parameters should be precisely adjusted in order to obtain AgNWs with a high aspect ratio. Consequently, controlling the reaction time versus the reaction temperature of the AgNWs is crucial to synthesize AgNWs with a high crystallinity and is important in fabricating optoelectronic devices. In this work, we tracked the morphological alterations of AgNWs during the growth process in order to determine the optimal reaction time and temperature. Thus, here, the UV-Vis absorption spectra were used to investigate how the reaction time varies with the temperature. The reaction was conducted at five different temperatures, 140-180 °C. As a result, an equation was developed to describe the relationship between them and to calculate the reaction time at any given reaction temperature. It was observed that the average diameter of the NWs was temperature-dependent and had a minimum value of 23 nm at a reaction temperature of 150 °C. A significant purification technique was conducted for the final product at a reaction temperature of 150 °C with two different speeds in the centrifuge to remove the heavy and light by-products. Based on these qualities, a AgNWs-based porous Si (AgNWs/P-Si) device was fabricated, and current-time pulsing was achieved using an ultra-violet (UV) irradiation of a 375 nm wavelength at four bias voltages of 1 V, 2 V, 3 V, and 4 V. We obtained a high level of sensitivity and detectivity with the values of 2247.49% and 2.89 × 1012 Jones, respectively. The photocurrent increased from the µA range in the P-Si to the mA range in the AgNWs/P-Si photodetector due to the featured surface plasmon resonance of the AgNWs compared to the other metals.

13.
Colloids Surf B Biointerfaces ; 228: 113423, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37390675

RESUMO

The novelty of this work is the conjugation of poly(ethylene) oxide (PEO) with the erbium oxide (Er2O3) nanoparticles using the electrospinning technique. In this work, synthesised PEO-coated Er2O3 nanofibres were characterised and evaluated for their cytotoxicity to assess their potential use as diagnostic nanofibres for magnetic resonance imaging (MRI). PEO has significantly impacted nanoparticle conductivity due to its lower ionic conductivity at room temperature. The findings showed that the surface roughness was improved over the nanofiller loading, implying an improvement in cell attachment. The release profile performed for drug-controlling purposes has demonstrated a stable release after 30 min. Cellular response in MCF-7 cells showed high biocompatibility of the synthesised nanofibres. The cytotoxicity assay results showed that the diagnostic nanofibres had excellent biocompatibility, indicating the feasibility for diagnosis purposes. With excellent contrast performance, the PEO-coated Er2O3 nanofibres developed novel T2 and T1-T2 dual-mode MRI diagnostic nanofibres leading to better cancer diagnosis. In conclusion, this work has demonstrated that the conjugation of PEO-coated Er2O3 nanofibres improved the surface modification of the Er2O3 nanoparticles as a potential diagnostic agent. Using PEO in this study as a carrier or polymer matrix significantly influenced the biocompatibility and internalisation efficiency of the Er2O3 nanoparticles without triggering any morphological changes after treatment. This work has suggested permissible concentrations of PEO-coated Er2O3 nanofibres for diagnostic uses.


Assuntos
Nanofibras , Polietilenoglicóis , Humanos , Polietilenoglicóis/metabolismo , Células MCF-7 , Óxidos , Imageamento por Ressonância Magnética , Etilenos
14.
Materials (Basel) ; 16(13)2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37444824

RESUMO

This paper reports the optical properties of zinc oxide nanofilm fabricated by using organic natural products from Salvia officinalis leaves (SOL) extract and discusses the effect of the nanocrystal (NC) structure (nanoyarn and nanomat-like structure) on nanofilm optical properties. The surface-active layer of the nanofilm of ZnO nanoparticles (ZnO NPs) was passivated with natural organic SOL leaves hydrothermally, then accumulated on zinc oxide nanorods (ZnO NRs). The nanofilms were fabricated (with and without PEO) on glass substrate (at 85 °C for 16 h) via chemical solution deposition (CSD). The samples were characterized by UV-vis, PL, FESEM, XRD, and TEM measurements. TEM micrographs confirmed the nucleation of ZnO NPs around 4 nm and the size distribution at 1.2 nm of ZnO QDs as an influence of the quantum confinement effect (QCE). The nanofilms fabricated with SOL surfactant (which works as a capping agent for ZnO NPs) represent distinct optoelectronic properties when compared to bulk ZnO. FESEM images of the nanofilms revealed nanoyarn and nanomat-like structures resembling morphologies. The XRD patterns of the samples exhibited the existence of ZnO nanocrystallites (ZnO NCs) with (100), (002), and (101) growth planes. The nanofilms fabricated represented a distinct optical property through absorption and broad emission, as the optical energy band gap reduced as the nanofilms annealed (at 120 ℃). Based on the obtained results, it was established that phytochemicals extracted from organic natural SOL leaves have a distinct influence on zoic oxide nanofilm fabrication, which may be useful for visible light spectrum trapping. The nanofilms can be used in photovoltaic solar cell applications.

15.
J Lasers Med Sci ; 14: e28, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37744010

RESUMO

Introduction: The depth of laser light penetration into tissue is a critical factor in determining the effectiveness of photodynamic therapy (PDT). However, the optimal laser light penetration depth necessary for achieving maximum therapeutic outcomes in PDT remains unclear. This study aimed to assess the effectiveness of laser light penetration depth at two specific wavelengths, 532 nm and 660 mm. Methods: Chicken and beef of different thicknesses (1, 3, 5, 10, and 20 mm±0.2 mm) were used as in vitro tissue models. The samples were subjected to irradiation by a low-level laser diode of 532 and 660 nm in continuous mode for 10 minutes. with power densities of 167 and 142 J/cm2, respectively. Laser light transmission through the tissue was measured using a power meter. Results: For beef samples, the 660 nm wavelength achieved a maximum transmission intensity of 30.7% at 1 cm thickness, while the 532 nm laser had a transmission intensity of 6.5%. Similarly, in chicken breast samples, the maximum transmission occurred at 1 cm thickness with 68.1% for the 660 nm wavelength and 18.2% for the 532 nm laser. Conclusion: Results consistently demonstrated a significant correlation (P<0.05) between tissue thickness and laser light penetration. Thicker tissues exhibited faster declines in light transmission intensity compared to thinner tissues within 10 minutes. These findings highlight the importance of further research to enhance light delivery in thicker tissues and improve the efficacy of PDT in various medical conditions.

16.
Chemosphere ; 343: 140223, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37734509

RESUMO

Covalent organic frameworks (COFs) are class of porous coordination polymers made up of organic building blocks joined together by covalent bonding through thermodynamic and controlled reversible polymerization reactions. This review discussed versatile applications of COFs for remediation of wastewater containing dyes, emphasizing the advantages of both pristine and modified materials in adsorption, membrane separation, and advanced oxidations processes. The excellent performance of COFs towards adsorption and membrane filtration has been centered to their higher crystallinity and porosity, exhibiting exceptionally high surface area, pore size and pore volumes. Thus, they provide more active sites for trapping the dye molecules. On one hand, the photocatalytic performance of the COFs was attributed to their semiconducting properties, and when coupled with other functional semiconducting materials, they achieve good mechanical and thermal stabilities, positive light response, and narrow band gap, a typical characteristic of excellent photocatalysts. As such, COFs and their composites have demonstrated excellent potentialities for the elimination of the dyes.

17.
Materials (Basel) ; 16(5)2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36902983

RESUMO

Herein, we investigated the applicability of thick film and bulk disk forms of aluminum-doped zinc oxide (AZO) for low-dose X-ray radiation dosimetry using the extended gate field effect transistor (EGFET) configuration. The samples were fabricated using the chemical bath deposition (CBD) technique. A thick film of AZO was deposited on a glass substrate, while the bulk disk form was prepared by pressing the collected powders. The prepared samples were characterized via X-ray diffraction (XRD) and field emission scanning electron microscope (FESEM) to determine the crystallinity and surface morphology. The analyses show that the samples are crystalline and comprise nanosheets of varying sizes. The EGFET devices were exposed to different X-ray radiation doses, then characterized by measuring the I-V characteristics pre- and post-irradiation. The measurements revealed an increase in the values of drain-source currents with radiation doses. To study the detection efficiency of the device, various bias voltages were also tested for the linear and saturation regimes. Performance parameters of the devices, such as sensitivity to X-radiation exposure and different gate bias voltage, were found to depend highly on the device geometry. The bulk disk type appears to be more radiation-sensitive than the AZO thick film. Furthermore, boosting the bias voltage increased the sensitivity of both devices.

18.
Biomater Adv ; 143: 213178, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36368056

RESUMO

Biocompatible polymers have received significant interest from researchers for their potential in diagnostic applications. This type of polymer can perform with an appropriate host response or carrier for a specific purpose. The current study aims to fabricate and characterise poly(ethylene) oxide (PEO) nanofibres with different concentrations for cytotoxicity evaluation in human breast cancer cell lines (MCF-7) and to get an optimal PEO nanofibre concentration (permissible limit) as a suitable polymer matrix or carrier with potential use in diagnostic applications. The fabrication of PEO nanofibres was done using electrospinning and was characterised by structure and morphology, surface roughness, chemical bonding and release profiles. The functional effects of PEO nanofibres were evaluated with MTS assay and colony formation assay in MCF-7 cells. The results showed that viscosity plays a vital role in synthesising a polymer solution in electrospinning for producing beadless nanofibrous mats ranging from 4.7 Pa·s to 77.7 Pa·s. As the PEO concentration increases, the nanofibre diameter and thickness will increase, but the surface roughness will be decreased. The average fibre diameter for 5 wt% PEO, 6 wt% PEO and 7 wt% PEO nanofibres were 129 ± 70 nm, 185 ± 55 nm and 192 ± 53 nm, respectively. In addition, the fibre thickness for 4 wt% PEO, 5 wt% PEO, 6 wt% PEO and 7 wt% PEO nanofibres were 269 ± 3 µm, 664 ± 4 µm, 758 ± 7 µm and 1329 ± 44 µm, respectively. Contrarily, the surface roughness for 4 wt% PEO, 5 wt% PEO, 6 wt% PEO and 7 wt% PEO nanofibres were 55.6 ± 9 nm, 42.8 ± 6 nm, 42.7 ± 7 nm and 36.6 ± 1 nm, respectively. PEO nanofibres showed the same burst release pattern and rate due to the same molecular weight of PEO with a stable release rate profile after 15 min. It also demonstrates that the percentage of PEO nanofibre release increased with the increasing PEO concentration due to the fibre diameter and thickness. The findings showed that all PEO nanofibres formulations were non-toxic to MCF-7 cells. It is suggested that 5 wt% PEO nanofibre exhibited non-cytotoxic characteristics by maintaining the cell viability from dose 0-1000 µg/ml and did not induce the number of colonies. Therefore, 5 wt% PEO nanofibre is the optimal nanofibre concentration and was suggested as a suitable base polymer matrix or carrier with potential use for diagnostic purposes. The findings in this study have demonstrated the influence of cell growth and viability, including the effects of PEO nanofibre formulations on cancer progress characteristics to achieve a permissible PEO nanofibre concentration limit that can be a benchmark in medical applications, particularly diagnostic applications.


Assuntos
Neoplasias da Mama , Nanofibras , Humanos , Feminino , Nanofibras/toxicidade , Polietilenoglicóis/química , Células MCF-7 , Neoplasias da Mama/tratamento farmacológico , Polímeros/química , Etilenos , Óxidos
19.
Sci Rep ; 12(1): 10549, 2022 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-35732668

RESUMO

Laser ablation synthesis in liquid solution (PLAL) is a green technique that allows for the physical formation of nanomaterials. This study indicates the preparation of stable gold nanoparticles (AuNPs) in Gum Arabic (GA) solution via laser ablation as a CT contrast agent. The optical properties were achieved using the absorption spectroscopic technique whereas the morphology and size distribution were investigated by TEM and ImageJ software. TEM image shows greater stability and spherical shape of GA-AuNPs with smaller size at 1.85 ± 0.99 nm compared to AuNPs without GA. The absorption spectrum of pure AuNPs has a lower absorption peak height in the visible range at λ = 521 nm, while the spectrum of GA-AuNPs has a higher plasmon peak height at λ = 514 nm with a blue shift towards lower wavelengths. The concentration of GA that dissolved in 10 mL of DI water via laser ablation is set at 20 mg. Increasing the number of pulses has only a minor effect on particle size distribution, which remains tiny in the nanometer range (less than 3 nm). For energies greater than 200 mJ, there is a blue shift toward shorter wavelengths. As the concentration of GA-AuNPs increases, the CT number is also increased indicating good image contrast. It can be concluded that there is a positive and significant influence of GA as a reducing agent for AuNPs, and a contrast agent for CT imaging which highlights its superiority in future medical applications.


Assuntos
Terapia a Laser , Nanopartículas Metálicas , Meios de Contraste , Ouro/química , Goma Arábica/química , Nanopartículas Metálicas/química , Tomografia Computadorizada por Raios X
20.
Materials (Basel) ; 15(17)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36079209

RESUMO

This study investigates the growth time effect on the structural, morphological, optical, and photoelectrochemical characteristics of highly oriented ZnO nanorod arrays (ZNRAs). The nanorod arrays were grown on ITO substrates using the unified sol-gel spin coating and hydrothermal techniques. ZnO nanoparticles (ZNPs) were synthesized using the sol-gel spin coating method. In contrast, the hydrothermal method was used to grow the ZnO nanorods. The hydrothermal growth time investigated was between 4 and 12 h. The synthesized ZNRAs were used as the photoanode electrodes to investigate their photoelectrochemical (PEC) electrode potency. The as-prepared ZNRAs were characterized using various analytical tools to determine their structures, morphologies, optical, and photoelectrochemical traits. EDX spectra showed the presence of uncontaminated ZnO chemical composition, and FTIR spectra displayed the various functional groups in the samples. A rod-shaped ZnO nanocrystallite with mean lengths and diameters of 300-500 nm and 40-90 nm, respectively, is depicted. HRTEM images indicated the nucleation and growth of ZNRAs with a lattice fringe spacing of 0.26 nm and a growth lattice planer orientation of [002]. The optimum ZNRAs (grown at 8 h) as photoelectrode achieved a photoconversion efficiency of 0.46% and photocurrent density of 0.63 mA/cm2, that was 17 times higher than the one shown by ZNPs with Ag/AgCl as the reference electrode. Both values were higher than those reported in the literature, indicating the prospect of these ZNRAs for photoelectrode applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA