Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Sep Sci ; 43(15): 3053-3060, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32419309

RESUMO

Switchable-hydrophilicity solvent liquid-liquid microextraction and dispersive liquid-liquid microextraction were compared for the extraction of piperine from Piper nigrum L. prior to its analysis by using high-performance liquid chromatography with UV detection. Under optimum conditions, limits of detection and quantitation were found as 0.2-0.6 and 0.7-2.0 µg/mg with the two methods, respectively. Calibration graphs showed good linearity with coefficients of determination (R2 ) higher than 0.9962 and percentage relative standard deviations lower than 6.8%. Both methods were efficiently used for the extraction of piperine from black and white pepper samples from different origins and percentage relative recoveries ranged between 90.0 and 106.0%. The results showed that switchable-hydrophilicity solvent liquid-liquid microextraction is a better alternative to dispersive liquid-liquid microextraction for the routine analysis of piperine in food samples. A novel scaled-up dispersive liquid-liquid microextraction method was also proposed for the isolation of piperine providing a yield of 102.9 ± 4.9% and purity higher than 98.0% as revealed by NMR spectroscopy.


Assuntos
Alcaloides/análise , Benzodioxóis/análise , Cicloexilaminas/química , Etilaminas/química , Contaminação de Alimentos/análise , Microextração em Fase Líquida , Piper nigrum/química , Piperidinas/análise , Alcamidas Poli-Insaturadas/análise , Cromatografia Líquida de Alta Pressão , Interações Hidrofóbicas e Hidrofílicas , Solventes/química , Espectrofotometria Ultravioleta , Raios Ultravioleta
2.
Anal Methods ; 15(38): 5018-5026, 2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37740274

RESUMO

Colorimetric determination of proteins in serum is proposed based on the biuret method and replacing ultraviolet-visible spectrometric (UV-Vis) detection with a simple and affordable smartphone digital image colorimetric (SDIC) method. Optimum SDIC conditions were found as a detection wavelength of 555 nm, a region of interest of 1600 px2, and 9.0 cm between the detection camera and sample solution. Under the optimum conditions, the coefficient of determination was 0.9982 within a linear dynamic range of 0.022 to 0.35 g dL-1. The precision of the method based on the percent relative standard deviation was below 5%. The limit of detection and limit of quantitation were found to be 0.007 and 0.022 g dL-1 respectively, which were sufficient for the quantification of the total protein, albumin, and globulin in serum. The method was validated with an independent experiment using a UV-Vis method and both methods showed good statistical agreement, indicating the accuracy of the proposed SDIC method.


Assuntos
Colorimetria , Smartphone , Colorimetria/métodos , Limite de Detecção , Proteínas Sanguíneas , Espectrofotometria Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA