Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Am Heart J ; 210: 1-8, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30711875

RESUMO

BACKGROUND: Coronary angiography and intervention to saphenous venous grafts (SVGs) remain challenging. This study aimed to investigate the feasibility and safety of the radial approach compared to femoral access in a large cohort of patients undergoing SVG angiography and intervention. METHODS: Data from 1,481 patients from Canada, United States, and Spain who underwent procedures between 2010 and 2016 were collected. Patients must have undergone SVG coronary angiography and/or intervention. Demographics, procedural data, and in-hospital complications were recorded. RESULTS: Procedures were undertaken by either the radial (n = 863, 211 intervention) or femoral (n = 618, 260 intervention) approach. The mean number of SVGs per patient was similar between groups (radial 2.3 ± 0.7 vs femoral 2.6 ± 1.1, P = .61), but the radial group required a fewer number of catheters (2.6 ± 1.7 vs 4.1 ± 1.1, P < .001). Fluoroscopy time was comparable between groups, and there was a trend toward lower contrast volume in the radial group (P = .045). Overall, the total dose of heparin was significantly higher in the radial group (P < .001); however, radial patients experienced significantly less access-site bleeding complications (P < .001). Outpatients undergoing radial SVG interventions had a higher likelihood of a same-day discharge home (P < .001). CONCLUSIONS: Radial access for SVG angiography and intervention is safe and feasible, without increasing fluoroscopy time. In experienced centers, radial access was associated with fewer catheters used, lower contrast volume, and lower rate of vascular access-site bleeding complications. Moreover, outpatients undergoing SVG percutaneous coronary intervention though the radial approach had a higher likelihood of a same-day discharge home.


Assuntos
Angiografia Coronária/métodos , Artéria Femoral , Intervenção Coronária Percutânea/métodos , Artéria Radial , Veia Safena/diagnóstico por imagem , Idoso , Índice de Massa Corporal , Canadá , Ponte de Artéria Coronária , Estudos de Viabilidade , Feminino , Fluoroscopia/estatística & dados numéricos , Hematoma/etiologia , Humanos , Masculino , Duração da Cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/estatística & dados numéricos , Inibidores da Agregação Plaquetária/administração & dosagem , Hemorragia Pós-Operatória/etiologia , Estudos Prospectivos , Estudos Retrospectivos , Segurança , Veia Safena/transplante , Espanha , Estados Unidos
2.
Cardiovasc Diabetol ; 16(1): 68, 2017 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-28526024

RESUMO

BACKGROUND: In diabetic patients a predisposed coronary microcirculation along with a higher risk of distal particulate embolization during primary percutaneous intervention (PCI) increases the risk of peri-procedural microcirculatory damage. However, new antiplatelet agents, in particular Ticagrelor, may protect the microcirculation through its adenosine-mediated vasodilatory effects. METHODS: PREDICT is an original, prospective, randomized, multicenter controlled study designed to investigate the protective effect of Ticagrelor on the microcirculation during PCI in patient with diabetes mellitus type 2 or pre-diabetic status. The primary endpoints of this study aim to test (i) the decrease in microcirculatory resistance with antiplatelet therapy (Ticagrelor > Clopidogrel; mechanistic effect) and (ii) the relative microcirculatory protection of Ticagrelor compared to Clopidogrel during PCI (Ticagrelor < Clopidogrel; protective effect). CONCLUSIONS: PREDICT will be the first multicentre clinical trial to test the adenosine-mediated vasodilatory effect of Ticagrelor on the microcirculation during PCI in diabetic patients. The results will provide important insights into the prospective beneficial effect of this drug in preventing microvascular impairment related to PCI ( http://www.clinicaltrials.gov No. NCT02698618).


Assuntos
Adenosina/análogos & derivados , Doença da Artéria Coronariana/terapia , Circulação Coronária/efeitos dos fármacos , Diabetes Mellitus Tipo 2/complicações , Microcirculação/efeitos dos fármacos , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/uso terapêutico , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Ticlopidina/análogos & derivados , Vasodilatação/efeitos dos fármacos , Adenosina/efeitos adversos , Adenosina/uso terapêutico , Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Protocolos Clínicos , Clopidogrel , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/fisiopatologia , Diabetes Mellitus Tipo 2/sangue , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Estudos Prospectivos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Projetos de Pesquisa , Fatores de Risco , Espanha , Ticagrelor , Ticlopidina/efeitos adversos , Ticlopidina/uso terapêutico , Fatores de Tempo , Resultado do Tratamento
3.
Cardiovasc Diagn Ther ; 9(3): 229-238, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31275813

RESUMO

BACKGROUND: Current consensus recommends extended vascular investigation in patients with spontaneous coronary artery dissection (SCAD). We here report our experience with the use of magnetic resonance angiography (MRA) for screening extra-coronary arteriopathy in patients presenting with SCAD. METHODS: Patients presenting with SCAD in a Spanish centre underwent prospective contrast-enhanced MRA to assess the cephalic and abdominopelvic arterial territories. Fibromuscular dysplasia (FMD) was diagnosed following European consensus criteria. Other vascular abnormalities were recorded separately. Two vascular radiologists supervised the acquisitions and independently analysed the results for all cases. RESULTS: Forty patients with SCAD [mean age 50.9±8.6 years, 90% (n=36) women] were included in the study, 12 patients declined to participate and 5 were excluded (metallic implanted devices). All enrolled patients underwent the screening protocol without complications. MRA demonstrated at least one extra-coronary vascular abnormality in 16 patients (40%): 5 (12.5%) were diagnosed with FMD, 6 (15%) showed arterial tortuosity, 3 (7.5%) had non-FMD focal stenoses, and 2 (5%) were found to have small aneurysms at the celiac trunk and splenic artery. No intracranial aneurysms were detected. At a mean follow-up of 4±3 years from the index episode, two cases experienced SCAD recurrences, one in a patient with FMD and the other one in a patient with arterial tortuosity. No deaths or strokes occurred. CONCLUSIONS: Systematic extended vascular study with MRA was feasible and demonstrated associated extra-coronary arteriopathy in a substantial proportion of patients presenting with SCAD; however, none required additional intervention or led to vascular events. MRA, being a radiation-free modality, may be the preferred method for screening extracoronary arteriopathy in SCAD, a condition primarily affecting young and middle-age women sensitive to the risks of radiation.

4.
Rev Esp Cardiol (Engl Ed) ; 71(8): 628-637, 2018 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29191780

RESUMO

INTRODUCTION AND OBJECTIVES: The predictive value of the SYNTAX score (SS) for clinical outcomes after transcatheter aortic valve implantation (TAVI) is very limited and could potentially be improved by the combination of anatomic and clinical variables, the SS-II. We aimed to evaluate the value of the SS-II in predicting outcomes in patients undergoing TAVI. METHODS: A total of 402 patients with severe symptomatic aortic stenosis undergoing transfemoral TAVI were included. Preprocedural TAVI angiograms were reviewed and the SS-I and SS-II were calculated using the SS algorithms. Patients were stratified in 3 groups according to SS-II tertiles. The coprimary endpoints were all-cause death and major adverse cardiovascular events (MACE), a composite of all-cause death, cerebrovascular event, or myocardial infarction at 1 year. RESULTS: Increased SS-II was associated with higher 30-day mortality (P=.036) and major bleeding (P=.015). The 1-year risk of death and MACE was higher among patients in the 3rd SS-II tertile (HR, 2.60; P=.002 and HR, 2.66; P<.001) and was similar among patients in the 2nd tertile (HR, 1.27; P=.507 and HR, 1.05; P=.895) compared with patients in the 1st tertile. The highest SS-II tertile was an independent predictor of long-term mortality (P=.046) and MACE (P=.001). CONCLUSIONS: The SS-II seems more suited to predict clinical outcomes in patients undergoing TAVI than the SS-I. Increased SS-II was associated with poorer clinical outcomes at 1 and 4 years post-TAVI, independently of the presence of coronary artery disease.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Causas de Morte/tendências , Angiografia Coronária , Ecocardiografia sob Estresse , Ecocardiografia Transesofagiana , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Resultado do Tratamento
5.
Rev Esp Cardiol (Engl Ed) ; 71(9): 735-742, 2018 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29191782

RESUMO

INTRODUCTION AND OBJECTIVES: The SAPIEN 3 (S3) valve and the Medtronic Evolut R (EVR) are second-generation transcatheter valves, designed to further reduce the rate of paravalvular aortic regurgitation (AoR). The aim of this study was to compare the 2 devices in terms of valve performance in a case-matched study with independent echocardiographic analysis. METHODS: Of a population of 201 patients who underwent transcatheter aortic valve implantation, 144 patients (S3, n = 80; EVR, n = 64) were matched according to aortic annulus diameter and aortic valve calcium score, as assessed by computed tomography. All echocardiographic examinations collected at baseline and at 1- and 6-month follow-up were centrally analyzed. RESULTS: The 2 groups were well balanced in baseline clinical and echocardiographic characteristics. The EVR valve showed a better hemodynamic profile as assessed by peak aortic gradient (EVR 13 ± 7 vs S3 20 ± 10mmHg; P<.001), mean aortic gradient (EVR 7 ± 3 vs S3 11 ± 6mmHg; P<.001), and Doppler velocity index (EVR 0.65±0.15 vs S3 0.51±0.16; P<.001). The rate of moderate-severe or any paravalvular (≥ mild) AoR was higher in the EVR group (11% and 50%) than in the S3 group (2.5% and 21%; P <.05, respectively), with a larger number of paravalvular jets (P <.001). CONCLUSIONS: In a case-matched cohort of transcatheter aortic valve implantation patients, the S3 valve was associated with a lower rate of paravalvular AoR but also with a higher residual gradient than the EVR system.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Desenho de Prótese , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA