Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Muscle Nerve ; 60(3): 292-298, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31269226

RESUMO

INTRODUCTION: There are no validated, practical, and quantitative measures of disease severity in Lambert-Eaton myasthenia (LEM). METHODS: Data from the Effectiveness of 3,4-Diaminopyridine in Lambert-Eaton Myasthenic Syndrome (DAPPER) trial were analyzed to assess triple timed up-and-go (3TUG) reproducibility and relationships between 3TUG times and other measures of LEM severity. RESULTS: The coverage probability technique showed ≥0.90 probability for an acceptable 3TUG difference of ≤0.2, indicating that it is reproducible in LEM patients. The correlation between 3TUG times and lower extremity function scores was significant in subjects who continued and in those who were withdrawn from 3,4-diaminopyridine free base. Worsening patient-reported Weakness Self-Assessment Scale and Investigator Assessment of Treatment Effect scores corresponded with prolongation of 3TUG times. DISCUSSION: The 3TUG is reproducible, demonstrates construct validity for assessment of lower extremity function in LEM patients, and correlates with changes in patient and physician assessments. These findings, along with prior reliability studies, indicate 3TUG is a valid measure of disease severity in LEM.


Assuntos
Síndrome Miastênica de Lambert-Eaton/fisiopatologia , Extremidade Inferior/fisiopatologia , Debilidade Muscular/fisiopatologia , Humanos , Programas de Rastreamento/métodos , Debilidade Muscular/tratamento farmacológico , Bloqueadores dos Canais de Potássio/uso terapêutico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
2.
Muscle Nerve ; 57(4): 561-568, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29280483

RESUMO

INTRODUCTION: 3,4-diaminopyridine has been used to treat Lambert-Eaton myasthenia (LEM) for 30 years despite the lack of conclusive evidence of efficacy. METHODS: We conducted a randomized double-blind placebo-controlled withdrawal study in patients with LEM who had been on stable regimens of 3,4-diaminopyridine base (3,4-DAP) for ≥ 3 months. The primary efficacy endpoint was >30% deterioration in triple timed up-and-go (3TUG) times during tapered drug withdrawal. The secondary endpoint was self-assessment of LEM-related weakness (W-SAS). RESULTS: Thirty-two participants were randomized to continuous 3,4-DAP or placebo groups. None of the 14 participants who received continuous 3,4-DAP had > 30% deterioration in 3TUG time versus 72% of the 18 who tapered to placebo (P < 0.0001). W-SAS similarly demonstrated an advantage for continuous treatment over placebo (P < 0.0001). Requirement for rescue and adverse events were more common in the placebo group. DISCUSSION: This trial provides significant evidence of efficacy of 3,4-DAP in the maintenance of strength in LEM. Muscle Nerve 57: 561-568, 2018.


Assuntos
Amifampridina/uso terapêutico , Desprescrições , Síndrome Miastênica de Lambert-Eaton/tratamento farmacológico , Debilidade Muscular/tratamento farmacológico , Fármacos Neuromusculares/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Método Duplo-Cego , Feminino , Humanos , Síndrome Miastênica de Lambert-Eaton/complicações , Quimioterapia de Manutenção , Masculino , Pessoa de Meia-Idade , Debilidade Muscular/etiologia , Adulto Jovem
3.
Muscle Nerve ; 57(1): 136-139, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28545168

RESUMO

INTRODUCTION: We report the reliability of a new measure, the triple-timed up-and-go (3TUG) test, for assessing clinical function in patients with Lambert-Eaton myasthenia (LEM). METHODS: Intrarater reproducibility and interrater agreement of the 3TUG test were assessed in 25 control participants, 24 patients with non-LEM neuromuscular disease, and 12 patients with LEM. The coverage probability (CP) method was the primary measure of reproducibility and agreement. The a priori acceptable range was < 20% difference in 3TUG test times and a CP ≥0.90 confirmed agreement. RESULTS: CP values > 0.90 for intrarater and interrater tests confirmed acceptable reproducibility and agreement for all groups. DISCUSSION: The 3TUG test is a quick, noninvasive, and reproducible measure that is easy to perform, measures clinically important weakness in LEM patients, and requires little training. Additional evaluation in a larger number of LEM patients is in progress to validate the 3TUG test as a clinical measure in LEM. Muscle Nerve 57: 136-139, 2017.


Assuntos
Síndrome Miastênica de Lambert-Eaton/diagnóstico , Adulto , Avaliação da Deficiência , Determinação de Ponto Final , Feminino , Humanos , Síndrome Miastênica de Lambert-Eaton/fisiopatologia , Masculino , Pessoa de Meia-Idade , Exame Neurológico , Doenças Neuromusculares/diagnóstico , Doenças Neuromusculares/fisiopatologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA