Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Cardiol Young ; 28(11): 1316-1322, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30220265

RESUMO

BACKGROUND: We reviewed all patients who were supported with extracorporeal membrane oxygenation and/or ventricular assist device at our institution in order to describe diagnostic characteristics and assess mortality. METHODS: A retrospective cohort study was performed including all patients supported with extracorporeal membrane oxygenation and/or ventricular assist device from our first case (8 October, 1998) through 25 July, 2016. The primary outcome of interest was mortality, which was modelled by the Kaplan-Meier method. RESULTS: A total of 223 patients underwent 241 extracorporeal membrane oxygenation runs. Median support time was 4.0 days, ranging from 0.04 to 55.8 days, with a mean of 6.4±7.0 days. Mean (±SD) age at initiation was 727.4 days (±146.9 days). Indications for extracorporeal membrane oxygenation were stratified by primary indication: cardiac extracorporeal membrane oxygenation (n=175; 72.6%) or respiratory extracorporeal membrane oxygenation (n=66; 27.4%). The most frequent diagnosis for cardiac extracorporeal membrane oxygenation patients was hypoplastic left heart syndrome or hypoplastic left heart syndrome-related malformation (n=55 patients with HLHS who underwent 64 extracorporeal membrane oxygenation runs). For respiratory extracorporeal membrane oxygenation, the most frequent diagnosis was congenital diaphragmatic hernia (n=22). A total of 24 patients underwent 26 ventricular assist device runs. Median support time was 7 days, ranging from 0 to 75 days, with a mean of 15.3±18.8 days. Mean age at initiation of ventricular assist device was 2530.8±660.2 days (6.93±1.81 years). Cardiomyopathy/myocarditis was the most frequent indication for ventricular assist device placement (n=14; 53.8%). Survival to discharge was 42.2% for extracorporeal membrane oxygenation patients and 54.2% for ventricular assist device patients. Kaplan-Meier 1-year survival was as follows: all patients, 41.0%; extracorporeal membrane oxygenation patients, 41.0%; and ventricular assist device patients, 43.2%. Kaplan-Meier 5-year survival was as follows: all patients, 39.7%; extracorporeal membrane oxygenation patients, 39.7%; and ventricular assist device patients, 43.2%. CONCLUSIONS: This single-institutional 18-year review documents the differential probability of survival for various sub-groups of patients who require support with extracorporeal membrane oxygenation or ventricular assist device. The indication for mechanical circulatory support, underlying diagnosis, age, and setting in which cannulation occurs may affect survival after extracorporeal membrane oxygenation and ventricular assist device. The Kaplan-Meier analyses in this study demonstrate that patients who survive to hospital discharge have an excellent chance of longer-term survival.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Previsões , Cardiopatias Congênitas/cirurgia , Coração Auxiliar , Feminino , Seguimentos , Cardiopatias Congênitas/mortalidade , Humanos , Lactente , Recém-Nascido , Estimativa de Kaplan-Meier , Masculino , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Reino Unido/epidemiologia
2.
Cardiol Young ; 26(3): 571-3, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26220108

RESUMO

This report describes the case of a neonate with d-transposition of the great arteries and severe pulmonary arterial hypertension stabilised in the post-operative period with continuous iloprost nebulisation. To our knowledge, this is the first documented method of treating post-operative severe pulmonary arterial hypertension with continuous inhaled iloprost in a patient with complex CHD. We found this method of delivering the drug very effective in stabilising haemodynamic swings in the setting of severe pulmonary arterial hypertension.


Assuntos
Hipertensão Pulmonar/tratamento farmacológico , Iloprosta/administração & dosagem , Óxido Nítrico/administração & dosagem , Transposição dos Grandes Vasos/cirurgia , Vasodilatadores/administração & dosagem , Administração por Inalação , Artérias/fisiopatologia , Evolução Fatal , Feminino , Hemodinâmica , Humanos , Recém-Nascido
3.
World J Pediatr Congenit Heart Surg ; 12(1): 17-26, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33407028

RESUMO

BACKGROUND: To assess changes in patterns of practice and outcomes over time, we reviewed all patients who underwent heart transplantation (HTx) at our institution and compared two consecutive eras with significantly different immunosuppressive protocols (cohort 1 [80 HTx, June 1995-June 2006]; cohort 2 [108 HTx, July 2006-September 2018]). METHODS: Retrospective study of 180 patients undergoing 188 HTx (June 1995-September 2018; 176 first time HTx, 10 second HTx, and 2 third HTx). In 2006, we commenced pre-HTx desensitization for highly sensitized patients and started using tacrolimus as our primary postoperative immunosuppressive agent. The primary outcome was mortality. Survival was modeled by the Kaplan-Meier method. Univariable and multivariable Cox proportional hazard models were created to identify prognostic factors for survival. RESULTS: Our 188 HTx included 18 neonates, 85 infants, 83 children, and 2 adults (>18 years). Median age was 260.0 days (range: 5 days-23.8 years). Median weight was 7.5 kg (range: 2.2-113 kg). Patients in cohort 1 were less likely to have been immunosensitized preoperatively (12.5% vs 28.7%, P = .017). Nevertheless, Kaplan-Meier analysis suggested superior survival in cohort 2 (P = .0045). Patients in cohort 2 were more likely to be alive one year, five years, and ten years after HTx. Multivariable analysis identified the earlier era (hazard ratio [HR] [95% confidence interval] for recent era = 0.32 [0.14-0.73]), transplantation after prior Norwood operation (HR = 4.44 [1.46-13.46]), and number of prior cardiac operations (HR = 1.33 [1.03-1.71]) as risk factors for mortality. CONCLUSIONS: Our analysis of 23 years of pediatric and congenital HTx reveals superior survival in the most recent 12-year era, despite the higher proportion of patients with elevated panel reactive antibody in the most recent era. This improvement was temporally associated with changes in our immunosuppressive strategy.


Assuntos
Cardiopatias Congênitas/cirurgia , Transplante de Coração/métodos , Procedimentos de Norwood/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
4.
World J Pediatr Congenit Heart Surg ; 9(5): 557-564, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30157732

RESUMO

BACKGROUND: This article reviews all patients who underwent heart transplantation (HTx) within a single institution (172 patients underwent 179 HTx [167 first-time HTxs, 10 second HTxs, 2 third HTxs]) to describe diagnostic characteristics, management protocols, and risk factors for mortality. METHODS: Descriptive analysis was performed for the entire cohort using mean, standard deviation, median, interquartile range, and overall range, as appropriate. Univariable and multivariable Cox proportional hazards models were performed to identify prognostic factors for outcomes over time. The primary outcome of interest was mortality, which was modeled by Kaplan-Meier analysis. RESULTS: Median age at HTx was 263 days (range, 5 days to 24 years; mean = 4.63 ± 5.95 years; 18 neonates, 79 infants). Median weight at HTx was 7.5 kg (range, 2.2-113 kg; mean = 19.36 ± 23.54). Diagnostic categories were cardiomyopathy (n = 62), primary transplantation for hypoplastic left heart syndrome (HLHS) or HLHS-related malformation (n = 33), transplantation after cardiac surgery for HLHS or HLHS-related malformation (n = 17), non-HLHS congenital heart disease (n = 55), and retransplant (n = 12). Operative mortality was 10.1% (18 patients). Cumulative total follow-up is 1,355 years. Late mortality was 18.4% (33 patients). Overall Kaplan-Meier five-year survival was 76.2%. One hundred twenty-one patients are alive with a mean follow-up of 7.61 ± 6.46 years. No survival differences were seen among the five diagnostic subgroups ( P = .064) or between immunosensitized patients (n = 31) and nonimmunosensitized patients (n = 141; P = .422). CONCLUSIONS: Excellent results are expected for children undergoing HTx with comparable results among diagnostic groups. Pretransplant mechanical circulatory support and posttransplant mechanical circulatory support are risk factors for decreased survival. Survival after transplantation for HLHS or HLHS-related malformation is better with primary HTx in comparison to HTx after prior cardiac surgery.


Assuntos
Previsões , Cardiopatias Congênitas/cirurgia , Transplante de Coração/mortalidade , Medição de Risco , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/mortalidade , Humanos , Lactente , Recém-Nascido , Estimativa de Kaplan-Meier , Masculino , Fatores de Risco , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos , Adulto Jovem
5.
ASAIO J ; 52(2): 206-10, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16557110

RESUMO

The purposes of this study were to quantify the insensible water loss that occurs across the Medtronic Minimax oxygenator and to estimate the resultant rise in fluid sodium concentration.A Carmeda-coated extracorporeal membrane oxygenation circuit connected to a Medtronic Minimax Plus oxygenator was primed with normal saline and attached to a closed reservoir. The gas sweep was randomly assigned to one of three rates: 2, 5, or 10 LPM (liters per minute). Each sweep rate was run in triplicate. The sodium concentration of the circuit was assessed after 12 and 24 hours of each trial. At the end of each 24-hour run, the evaporative loss was calculated. The average insensible water losses were 6.9+/-0.4 ml/h, 16.6+/-1.5 ml/h, and 34.4+/-0.3 ml/h at gas sweep rates of 2, 5, and 10 LPM, respectively (p<0.0001). Daily evaporative water losses for the membrane can be estimated to be 82.7+/-2.2 ml for each 1 LPM of sweep gas flow for a normal saline pump flow of 300 ml/min. In a closed circuit, a faster sweep gas rate is associated with a more rapid rise in sodium concentration (p<0.0001).


Assuntos
Oxigenação por Membrana Extracorpórea , Perda Insensível de Água , Técnicas In Vitro , Sódio/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA