Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Orthod Craniofac Res ; 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459802

RESUMO

OBJECTIVES: To use the finite element method (FEM) to investigate the effect of various attachment configurations and trimming line designs of orthodontic aligners on their biomechanical performance. METHOD: A 3D upper jaw model was imported into 3D design software. The upper right central incisor tooth (Tooth 11) was made mobile, and its periodontal ligament (PDL) and bone structures were designed. Aligners were modelled with three distinct attachment configurations: No attachment, rectangular horizontal, rectangular vertical, and two trimming line designs; scalloped and straight extended, with a homogeneous thickness of 0.6 mm. These models were then imported into an FE software. Simulations were conducted for three different movements, including facial translation, distalization, and extrusion. RESULTS: Forces were recorded at 1.3-2.6 N during facial translation, 1.4-5.9 N in distalization, and 0.0-2.0 N in extrusion. The straight extended trimming line consistently generated higher forces than the scalloped design. Attachments had no significant impact on force components during facial translation but were more effective in distalization and extrusion. The combination of a straight extended trimming line with horizontal attachments exhibited the least stresses at the apical third during distalization, and the highest stresses during extrusion, suggesting superior retention. CONCLUSIONS: Rectangular attachments offer limited benefits in facial translation, but horizontal rectangular attachments can intensify load in distalization and are crucial for force generation in extrusion. Horizontal attachments are preferred over vertical options. Additionally, the straight extended trim line enhances control of tooth movement and can replace attachments in certain cases. CLINICAL RELEVANCE: These findings provide biomechanical evidence and an optimal protocol to guide clinical practice in planning diverse teeth movements. The emphasis is on the influence of attachment utilization and the specific design of aligner trimming lines to enhance control over tooth movement.

2.
Orthod Craniofac Res ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38887908

RESUMO

OBJECTIVES: Investigating the impact of thermal and mechanical loading on the force generation of orthodontic aligners made from various thermoplastic materials and different compositions. MATERIALS AND METHODS: Five distinct materials were utilized including, three multi-layer (Zendura FLX, Zendura VIVA, CA Pro) and two single-layer (Zendura A and Duran). A total of 50 thermoformed aligners (n = 10) underwent a 48-hour ageing protocol, which involved mechanical loading resulting from a 0.2 mm facial malalignment of the upper right central incisor (Tooth 11) and thermal ageing through storage in warm distilled water at 37°C. The force exerted on Tooth 11 of a resin model was measured both before and after ageing using pressure-sensitive films and a biomechanical setup. RESULTS: Before ageing, pressure-sensitive films recorded normal contact forces ranging from 83.1 to 149.7 N, while the biomechanical setup measured resultant forces ranging from 0.1 to 0.5 N, with lingual forces exceeding facial forces. Multi-layer materials exhibited lower force magnitudes compared to single-layer materials. After ageing, a significant reduction in force was observed, with some materials experiencing up to a 50% decrease. Notably, multi-layer materials, especially Zendura VIVA, exhibited lower force decay. CONCLUSIONS: The force generated by aligners is influenced by both the aligner material and the direction of movement. Multi-layer materials exhibit superior performance compared to single-layer materials, primarily because of their lower initial force, which enhances patient comfort, and their capability to maintain consistent force application even after undergoing ageing.

3.
Clin Oral Investig ; 28(5): 258, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38637429

RESUMO

OBJECTIVES: To investigate the effects of material type and thickness on force generation and distribution by aligners. MATERIALS AND METHODS: Sixty aligners were divided into six groups (n = 10): one group with a thickness of 0.89 mm using Zendura Viva (Multi-layer), four groups with a thickness of 0.75 mm using Zendura FLX (Multi-layer), CA Pro (Multi-layer), Zendura (Single-layer), and Duran (Single-layer) sheets, and one group with a thickness of 0.50 mm using Duran sheets. Force measurements were conducted using Fuji® pressure-sensitive films. RESULTS: The lowest force values, both active and passive, were recorded for the multi-layered sheets: CA Pro (83.1 N, 50.5 N), Zendura FLX (88.9 N, 60.7 N), and Zendura Viva (92.5 N, 68.5 N). Conversely, the highest values were recorded for the single-layered sheets: Duran (131.9 N, 71.8 N) and Zendura (149.7 N, 89.8 N). The highest force was recorded at the middle third of the aligner, followed by the incisal third, and then the cervical third. The net force between the incisal and cervical thirds (FI-FC) showed insignificant difference across different materials. However, when comparing the incisal and middle thirds, the net force (FI-FM) was higher with single-layered materials. Both overall force and net force (FI-FM) were significantly higher with 0.75 mm compared to those with a thickness of 0.50 mm. CONCLUSIONS: Multi-layered aligner materials exert lower forces compared to their single-layered counterparts. Additionally, increased thickness in aligners results in enhanced retention and greater force generation. For effective bodily tooth movement, thicker and single-layered rigid materials are preferred. CLINICAL RELEVANCE: This research provides valuable insights into the biomechanics of orthodontic aligners, which could have significant clinical implications for orthodontists. Orthodontists might use this information to more effectively tailor aligner treatments, considering the specific tooth movement required for each individual patient. In light of these findings, an exchangeable protocol for aligner treatment is suggested, which however needs to be proven clinically. This protocol proposes alternating between multi-layered and single-layered materials within the same treatment phase. This strategy is suggested to optimize treatment outcomes, particularly when planning for a bodily tooth movement.


Assuntos
Desenho de Aparelho Ortodôntico , Técnicas de Movimentação Dentária , Humanos , Fenômenos Biomecânicos , Resultado do Tratamento , Técnicas de Movimentação Dentária/métodos
4.
J Prosthet Dent ; 131(3): 530.e1-530.e11, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262839

RESUMO

STATEMENT OF PROBLEM: The influence of different thicknesses, translucencies, and fabrication methods on the spectrophotometric and topographical properties of zirconia-reinforced lithium silicate glass-ceramics (ZLSs) for dental restorations remains unclear. PURPOSE: The purpose of this in vitro study was to investigate the effect of thicknesses, translucencies, and fabrication methods on the color stability, translucency parameter, opalescence parameter, whiteness stability, transmitted irradiance, light transmittance, opacity, gloss, and roughness of ZLSs exposed to coffee staining and bleaching treatments. MATERIAL AND METHODS: Two pressable ZLSs (VITA AMBRIA, VA and Celtra Press, CP) and 2 machinable ZLSs (VITA Suprinity, VS and Celtra Duo, CD) were examined at high translucency (HT) and low translucency (LT) levels in 2 thicknesses (n=160). The specimens were evaluated at baseline, after coffee staining, and after bleaching. The color stability (ΔE2000), translucency parameter (TP), opalescence parameter (OP), whiteness index (WID), and whiteness stability (ΔWID) were measured with a spectrophotometer. Transmitted irradiance (It), light transmission (T), and opacity (O) were obtained from a light-polymerizing unit and a polymerization light collection device. Roughness stability (ΔSa%) was determined with an optical profilometer, and gloss stability (ΔGU%) was recorded with a gloss meter. Data of ΔCIE2000, ΔWID, ΔSa%, and ΔGU% were analyzed by 4-way ANOVA, and data of the TP, OP, WID, It, T, and O were analyzed by repeated 4-way ANOVA (α=.05). RESULTS: VS-HT exceeded the ΔCIE2000 acceptability threshold after coffee staining and bleaching protocols. Pressable ZLSs exhibited greater color stability than machinable ZLSs. The 1-mm-thick VA, CP, and CD materials exceeded the ΔWID perceptibility threshold after bleaching. The highest TP and OP was displayed by the 1-mm-thick CP after bleaching. ΔGU increased after water storage and decreased after coffee staining and bleaching. ΔSa% significantly increased after bleaching (P<.05). CONCLUSIONS: The color stability and other spectrophotometric properties of ZLSs depended on material thickness. The effects of ZLS fabrication methods and translucency levels on their measured properties were inconsistent. Subjecting 1-mm-thick ZLS materials to acidic media adversely impacted their stainability and surface texture.


Assuntos
Café , Lítio , Zircônio , Silicatos , Coloração e Rotulagem , Cerâmica/uso terapêutico
5.
BMC Oral Health ; 24(1): 620, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807109

RESUMO

BACKGROUND: The mechanical properties of fully crystallized lithium aluminosilicate ceramics may be influenced by intraoral temperature variations and postmilling surface treatment. The purpose of this study is to explore the interplay among glazing, thermocycling, and the mechanical characteristics (namely, fracture toughness and hardness) of fully crystallized lithium aluminosilicate ceramics. METHODS: Bending bars (n = 40) cut from LisiCAD blocks (GC, Japan) were randomly assigned to glazed or unglazed groups (n = 20) and subjected to the single edge v-notch beam method to create notches. A glazing firing cycle was applied to the glazed group, while the unglazed group was not subjected to glazing. Half of the specimens (n = 10) from both groups underwent thermocycling before fracture toughness testing. The fracture toughness (KIC) was evaluated at 23 ± 1 °C using a universal testing machine configured for three-point bending, and the crack length was measured via light microscopy. Seven specimens per group were selected for the hardness test. Hardness was assessed using a Vickers microhardness tester with a 1 kg load for 20 s, and each specimen underwent five indentations following ISO 14705:2016. The Shapiro-Wilk and Kolmogorov-Smirnov tests were used to evaluate the normality of the data and a two-way ANOVA was utilized for statistical analysis. The significance level was set at (α = 0.05). RESULTS: Regardless of the thermocycling conditions, the glazed specimens exhibited significantly greater fracture toughness than did their unglazed counterparts (P < 0.001). Thermocycling had no significant impact on the fracture toughness of either the glazed or unglazed specimens. Furthermore, statistical analysis revealed no significant effects on hardness with thermocycling in either group, and glazing alone did not substantially affect hardness. CONCLUSIONS: The impact of glazing on the fracture toughness of LiSiCAD restorations is noteworthy, but it has no significant influence on their hardness. Furthermore, within the parameters of this study, thermocycling was found to exert negligible effects on both fracture toughness and hardness.


Assuntos
Silicatos de Alumínio , Cerâmica , Desenho Assistido por Computador , Dureza , Teste de Materiais , Cerâmica/química , Silicatos de Alumínio/química , Análise do Estresse Dentário , Propriedades de Superfície , Cristalização
6.
J Prosthodont ; 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38734932

RESUMO

PURPOSE: To evaluate the fracture resistance of zirconia overlays, considering various preparation designs and the presence of endodontic access. MATERIALS AND METHODS: Ninety translucent zirconia (5Y-PSZ) overlay restorations were divided into six groups (n = 15/group) based on different preparation designs, with and without endodontic access: chamfer margin 4 mm above the gingival level without (group 1) and with endodontic access (group 2); margin 2 mm above the gingival level without (group 3) and with endodontic access (group 4); overlay with no chamfer margin without (group 5) and with endodontic access (group 6). Restorations were bonded to mandibular first molar resin dies, and the groups with endodontic access were sealed with flowable resin composite. All restorations underwent 100,000 cycles of thermal cycling between 5°C and 55°C, followed by loading until fracture. Maximum load and fracture resistance were recorded. ANOVA with Tukey post-hoc tests were used for statistical comparison (α < 0.05). RESULTS: Fracture resistance significantly varied among overlay designs with and without endodontic access (p < 0.001), except for the no-margin overlays (groups 5 and 6). Overlays with a 2 mm margin above the gingival margin with endodontic access (group 4) exhibited significantly higher fracture resistance compared to both the 4-mm supragingival (group 2) and no-margin (group 6) designs, even when compared to their respective intact groups (groups 1 and 5). There were no significant differences between the no-margin and 4-mm supragingival overlays. CONCLUSION: The more extensive zirconia overlay for mandibular molars is the first choice since the 2 mm margin above the gingival level design withstood considerable loads even after undergoing endodontic access. A no-margin overlay is preferred over the 4-mm supragingival design as it preserves more tooth structure and there was no outcome difference, irrespective of endodontic access. Caution is warranted in interpreting these findings due to the in vitro nature of the study.

7.
J Prosthodont ; 32(9): 861-866, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36609993

RESUMO

PURPOSE: The available independent data on the translucency of novel pre and fully sintered chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate are limited. This comparative in vitro study evaluated the translucency degree of pre and fully sintered chairside CAD-CAM lithium disilicate crowns after optional, required, and additional firing processes. MATERIALS AND METHODS: One hundred and five maxillary left central incisor crowns manufactured by three different CAD-CAM lithium disilicate brands shade A1 were assigned into seven groups as follows (n = 15): (1) Straumann n!ce without sintering; (2) Straumann n!ce with one additional sintering process; (3) Straumann n!ce with two additional sintering processes; (4) Amber Mill with one sintering process; (5) Amber Mill with two sintering processes; (6) IPS e.max CAD with one sintering process; and (7) IPS e.max CAD with two sintering processes. The translucency of all crowns was evaluated with a color imaging spectrophotometer. All statistical analyses were performed using statistical software. A standard level of significance was set at α < 0.05. RESULTS: All the milled crowns presented different degrees of translucency, and additional sintering processes altered it. IPS e.max CAD with two (4.33 ± 0.26) and one (4.01 ± 0.15) sintering processes displayed the highest translucency, whereas Straumann n!ce with no sintering process provided the lowest value (2.82 ± 0.16). CONCLUSIONS: The translucency of chairside lithium disilicate single-unit full-coverage restorations manufactured with subtractive technology was significantly influenced by the brand and the number of sintering processes. The traditional presintered IPS e.max CAD and the fully crystallized glass-ceramic Straumann n!ce considerably increased the translucency after one additional firing process, whereas Amber Mill decreased its translucency.


Assuntos
Âmbar , Porcelana Dentária , Cerâmica , Coroas , Desenho Assistido por Computador , Teste de Materiais
8.
J Prosthodont ; 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37624691

RESUMO

PURPOSE: To evaluate the effect of polishing and denture cleansers on the surface roughness (Ra ) of new-generation denture base materials that are additively, subtractively, and conventionally fabricated, while also assessing their color change after cleansing. MATERIAL AND METHODS: One hundred and fifty disk-shaped specimens (Ø10 × 2 mm) were prepared from five denture base materials (one subtractively manufactured nanographene-reinforced prepolymerized polymethylmethacrylate (PMMA) (SM-GC), one subtractively manufactured prepolymerized PMMA (SM-PM), two additively manufactured denture base resins (AM-DT and AM-ND), and one heat-polymerized PMMA (CV) (n = 30). The Ra of the specimens was measured before and after conventional laboratory polishing, while color coordinates were measured after polishing. Specimens were then divided into three subgroups based on the denture cleanser: distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet (n = 10). The Ra and color coordinates were remeasured after nine cleansing cycles over a period of 20 days. The CIEDE2000 formula was used to calculate the color differences (ΔE00 ). Two-way analysis of variance (ANOVA) was used to analyze the Ra values before (n = 30) and after (n = 10) cleansing, while repeated measures ANOVA was used to analyze the Ra of material-time point pairs within each denture cleanser (n = 10). ΔE00 data after denture cleansing was also analyzed by using two-way ANOVA (n = 10) (α = 0.05). RESULTS: Before polishing, Ra varied significantly among the materials. SM-GC and SM-PM had the lowest and AM-ND the highest Ra values (P < 0.001). Polishing significantly reduced Ra of all materials (P < 0.001), and after polishing, Ra differences among materials were nonsignificant (P ≥ 0.072). Regardless of the denture cleanser, the Ra of AM-DT, AM-ND, and CV was the highest before polishing when different time points were considered (P < 0.001). After cleansing, AM-ND had the highest Ra of all the materials, regardless of the cleanser (P ≤ 0.017). AM-DT had higher Ra than SM-PM when distilled water (P = 0.040) and higher Ra than SM-GC, SM-PM, and CV when NaOCl was used (P < 0.001). The type of cleanser significantly influenced the Ra of AM-DT, AM-ND, and CV. For AM-DT, NaOCl led to the highest Ra and the tablet led to the lowest Ra (P ≤ 0.042), while for AM-ND, distilled water led to the lowest Ra (P ≤ 0.024). For CV, the tablet led to lower Ra than distilled water (P = 0.009). Color change varied among the materials. When distilled water was used, SM-GC had higher ΔE00 than SM-PM and AM-DT (P ≤ 0.034). When NaOCl was used, AM-ND had higher ΔE00 than SM-GC, SM-PM, and AM-DT, while CV and SM-GC had higher ΔE00 than SM-PM and AM-DT (P ≤ 0.039). Finally, when the tablet was used, AM-ND and CV had the highest ΔE00 , while AM-DT had lower ΔE00 than SM-GC (P ≤ 0.015). CONCLUSIONS: The tested materials had unacceptable surface roughness (>0.2 µm) before polishing. Roughness decreased significantly after polishing (<0.2 µm). Denture cleansers did not significantly affect the surface roughness of the materials, and roughness remained clinically acceptable after cleansing (<0.2 µm). Considering previously reported color thresholds, AM-ND and CV had unacceptable color change regardless of the denture cleanser, and the effervescent tablet led to perceptible, but acceptable color change for SM-GC, SM-PM, and AM-DT.

9.
J Prosthodont ; 2023 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-37837403

RESUMO

PURPOSE: To develop a biocompatible denture base resin/TiO2 nanocomposite material with antifungal characteristics that is suitable for 3D-printing denture bases. MATERIALS AND METHODS: TiO2 nanoparticles (NPs) with a 0.10, 0.25, 0.50, and 0.75 weight percent (wt.%) were incorporated into a commercially available 3D-printed resin material. The resulting nanocomposite material was analyzed using Lactate dehydrogenase (LDH) and AlamarBlue (AB) assays for biocompatibility testing with human gingival fibroblasts (HGF). The composite material was also tested for its antifungal efficacy against Candida albicans. Fourier transform infrared (FTIR) and Energy Dispersive X-ray Spectroscopy (EDX) mapping were conducted to assess the surface coating and the dispersion of the NPs. RESULTS: LDH and AB assays confirmed the biocompatibility of the material showing cell proliferation at a rate of nearly 100% at day 10, with a cytotoxicity of less than 13% of the cells at day 10. The concentrations of 0.10, 0.25, and 0.50 wt.% caused a significant reduction (p < 0.05) in the number of candida cells attached to the surface of the specimens (p < 0.05), while 0.75 wt.% did not show any significant difference compared to the control (no TiO2 NPs) (p > 0.05). FTIR and EDX analysis confirmed the presence of TiO2 NPs within the nanocomposite material with a homogenous dispersion for 0.10 and 0.25 wt.% groups and an aggregation of the NPs within the material at higher concentrations. CONCLUSION: The addition of TiO2 NPs into 3D-printed denture base resin proved to have an antifungal effect against Candida albicans. The resultant nanocomposite material was a biocompatible material with HGFs and was successfully used for 3D printing.

10.
Int J Biomater ; 2024: 8060363, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38919543

RESUMO

Three-dimensional (3D) printing is becoming more prevalent in the dental sector due to its potential to save time for dental practitioners, streamline fabrication processes, enhance precision and consistency in fabricating prosthetic models, and offer cost-effective solutions. However, the effect of aging in artificial saliva of this type of material has not been explored. To assess the physical and mechanical properties of the two types of 3D-printed materials before and after being subjected to artificial saliva, a total of 219 acrylic resin specimens were produced. These specimens were made with two types of 3D-printed materials, namely, NextDent (ND) and Formlabs (FLs), and a Schottlander heat-cured (HC) resin material that was used as a control. Water sorption and solubility specimens (n = 5) were tested after three months of storage in artificial saliva. Moreover, the Vickers hardness, Martens hardness, flexural strength/modulus, and impact strength were evaluated both under dry conditions and after three months of storage in artificial saliva. The degree of conversion (DC), elemental analysis, and filler content were also investigated. The ANOVA showed that 3D-printed resins had significantly greater sorption than the control group (p < 0.05). However, the flexural strength values of the 3D-printed materials were significantly greater (p < 0.05) than those of the heat-cured material. The DC of the 3D-printed resins was lower than that of the control group, but the difference was not significant (p > 0.05). The 3D-printed materials contained significantly more filler than the control (p < 0.05). Moreover, the artificial saliva had a significant effect on the Vickers hardness for all tested groups and on the Martens hardness for the control group only (p < 0.05). Compared with conventional heat-cured materials, 3D-printed denture base materials demonstrated relatively poorer performance in terms of sorption, solubility, and DC but exhibited either comparable or superior mechanical properties. The aging process also influenced the Vickers and Martens' hardness. The strength of the 3D-printed materials was in compliance with ISO recommendations, and the materials could be used alongside conventional heat-cured materials.

11.
J Dent ; : 105151, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38909644

RESUMO

OBJECTIVES: The present study aimed to evaluate the trueness and precision of monolithic zirconia crowns (MZCs) fabricated by 3D printing and milling techniques. METHODS: A premolar crown was designed after scanning a prepared typodont. Twenty MZCs were fabricated using milling and 3D-printing techniques (n=10). All the specimens were scanned with an industrial scanner, and the scanned data were analyzed using 3D measurement software to evaluate the trueness and precision of each group. Root mean square (RMS) deviations were measured and statistically analyzed (One-way ANOVA, Tukey's, p≤0.05). RESULTS: The trueness of the printed MZC group (140 ± 14 µm) showed a significantly higher RMS value compared to the milled MZCs (96 ± 27 µm,p<0.001). At the same time, the precision of the milled MZCs (61±17 µm) showed a significantly higher RMS value compared to that of the printed MZCs (31±5 µm,p<0.001). CONCLUSIONS: The Fabrication techniques had a significant impact on the accuracy of the MZCs. Milled MZCs showed the highest trueness, while printed MZCs showed the highest precision. All the results were within the clinically acceptable error values. CLINICAL SIGNIFICANCE: Although the trueness of the milled MZCs is higher, the manufacturing accuracy of the 3D-printed MZCs showed clinically acceptable results in terms of trueness and precision. However, additional clinical studies are recommended. Furthermore, the volumetric changes of the material should be considered.

12.
J Mech Behav Biomed Mater ; 150: 106337, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38154364

RESUMO

OBJECTIVES: To conduct a physiochemical and mechanical material analysis on 3D printed shape-memory aligners in comparison to thermoformed aligners. MATERIALS AND METHODS: Four materials were examined, including three thermoformed materials: CA Pro (CP), Zendura A (ZA), Zendura FLX (ZF), and one 3D printed material: Tera Harz (TC-85). Rectangular strips measuring 50 × 10 × 0.5 mm were produced from each material. Five tests were conducted, including differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), shape recovery tests, three-points bending (3 PB), and Vickers surface microhardness (VH). RESULTS: DSC recorded glass transition temperatures (Tg) at 79.9 °C for CP, 92.2 °C for ZA, 107.1 °C for ZF, and 42.3 °C for TC-85. In DMA analysis at 20-45 °C, a prominent decrease in storage modulus was observed, exclusively for TC-85, as the temperature increased. Notably, within the temperature range of 30-45 °C, TC-85 exhibited substantial shape recovery after 10 min, reaching up to 86.1 %, while thermoformed materials showed minimal recovery (1.5-2.9 %). In 3 PB test (at 30, 37, 45 °C), ZA demonstrated the highest force at 2 mm bending, while TC-85 exhibited the lowest. Regarding VH at room temperature, there was a significant decrease for both ZA and ZF after thermoforming. ZA had the highest hardness, followed by ZF and TC-85, with CP showing the lowest values. CONCLUSIONS: TC-85 demonstrates exceptional shape memory at oral temperature, improving adaptation, reducing force decay, and enabling, together with its higher flexibility, extensive tooth movement per step. Additionally, it maintains microhardness similar to thermoformed sheets, ensuring the durability and effectiveness of dental aligners. CLINICAL RELEVANCE: The 3D printed aligner material with shape memory characteristics (4D aligner) has revolutionized the orthodontic aligner field. It showed mechanical properties more suitable for orthodontic treatment than thermoforming materials. Additionally, it offers enhanced control over aligner design and thickness, while optimizing the overall workflow. It also minimizes material wastage, and reduces production expenses.


Assuntos
Materiais Inteligentes , Fenômenos Mecânicos , Vidro , Temperatura de Transição , Impressão Tridimensional
13.
Dent Mater ; 40(3): 500-507, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38184445

RESUMO

OBJECTIVE: This study aims to investigate the influence of post-polymerization (post-curing) conditions on surface characteristics, flexural properties, water sorption and solubility, and cytotoxicity of additively manufactured denture base materials. METHODS: The tested specimens were additively manufactured using digital light processing and classified into different post-curing condition groups: submerged in water (WAT), submerged in glycerin (GLY), and air exposure (AIR). An uncured specimen (UNC) was used as a control. The surface topography and roughness were observed. The flexural strength and modulus were determined via a three-point bending test. The water sorption and solubility were subsequently tested. Finally, an extract test was performed to assess cytotoxicity. RESULTS: Different post-curing conditions had no significant effects on the surface topography and roughness (Sa value). Various post-curing conditions also had no significant effects on the flexural strength. Notably, the flexural modulus of the WAT group (2671.80 ± 139.42 MPa) was significantly higher than the AIR group (2197.47 ± 197.93 MPa, p = 0.0103). After different post-curing conditions, the water sorption and solubility of the specimens met the ISO standards. Finally, all post-curing conditions effectively reduced cytotoxic effects. SIGNIFICANCES: Post-curing with different oxygen levels improved flexural properties, and flexural modulus significantly increased after the specimens were submerged in water. In addition, water sorption and solubility, and cytocompatibility were optimized by post-curing, irrespective of the post-curing conditions. Therefore, the water-submerged conditions optimized the flexural modulus of the 3D-printed denture base materials.


Assuntos
Materiais Dentários , Polímeros , Bases de Dentadura , Propriedades de Superfície , Teste de Materiais , Água , Impressão Tridimensional
14.
Saudi Dent J ; 36(1): 140-145, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38375383

RESUMO

Purpose: Our in vitro comparative study aimed to investigate the impact of thickness and tooth shade background on the translucency of highly translucent zirconia veneers. Materials and Methods: A total of 75 5Y-TZP zirconia veneers of shade A1 were fabricated with thicknesses of 0.50 mm (n = 25), 0.75 mm (n = 25), and 1.0 mm (n = 25). The translucencies were measured on composite resin teeth with shades A1, A2, A3, A3.5, and A4 using a digital color imaging spectrophotometer. Data were analyzed using ANOVA and post hoc Tukey's test (p < 0.05). Results: The translucency values were optimal for the veneers placed over the substrate teeth with shades A1 and A2, regardless of the veneer thickness. Additionally, veneers with a thickness of 0.50 mm exhibited significantly higher translucency than those with thicknesses of 0.75 mm and 1.0 mm. Conclusions: Our study demonstrated that the translucency of the highly translucent zirconia veneers was influenced by both veneer thickness and tooth shade background. The optimal veneer thickness for achieving the highest translucency was 0.50 for the veneers with A1 and A2 shades placed over the substrate teeth. Clinical Relevance: The optimal thickness for achieving the highest translucency of the highly translucent zirconia laminate veneers was 0.50 mm for the veneers with A1 and A2 shades placed over the substrate teeth. Clinicians and dental technicians could consider this when selecting materials for aesthetic restorations.

15.
Materials (Basel) ; 17(12)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38930391

RESUMO

This research aims to investigate the influence of model height employed in the deep drawing of orthodontic aligner sheets on force transmission and aligner thickness. Forty aligner sheets (Zendura FLX) were thermoformed over four models of varying heights (15, 20, 25, and 30 mm). Normal contact force generated on the facial surface of the upper right central incisor (Tooth 11) was measured using pressure-sensitive films. Aligner thickness around Tooth 11 was measured at five points. A digital caliper and a micro-computed tomography (µ-CT) were employed for thickness measurements. The normal contact force exhibited an uneven distribution across the facial surface of Tooth 11. Model 15 displayed the highest force (88.9 ± 23.2 N), while Model 30 exhibited the lowest (45.7 ± 15.8 N). The force distribution was more favorable for bodily movement with Model 15. Thickness measurements revealed substantial thinning of the aligner after thermoforming. This thinning was most pronounced at the incisal edge (50% of the original thickness) and least at the gingivo-facial part (85%). Additionally, there was a progressive reduction in aligner thickness with increasing model height, which was most significant on the facial tooth surfaces. We conclude that the thermoplastic aligner sheets undergo substantial thinning during the thermoforming process, which becomes more pronounced as the height of the model increases. As a result, there is a decrease in both overall and localized force transmission, which could lead to increased tipping by the aligner and a diminished ability to achieve bodily movement.

16.
Dent Mater ; 40(4): 747-755, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38418282

RESUMO

OBJECTIVE: The objective of this study was to 1) compare the stress corrosion coefficient (n) of a Y-TZP obtained by two fatigue tests: cyclic and dynamic and 2) evaluate the effect of frequency in the characteristic lifetime and the existence of interaction between the cyclic fatigue and slow crack growth. METHODS: A total of 145 Y-TZP specimens were produced in accordance with the manufacturer's instructions. These specimens, measuring 4.0 × 3.0 × 25.0 mm, were used for dynamic (n = 70) and cyclic fatigue tests (n = 75). The specimens were obtained from CAD/CAM blocks, sectioned, and sintered in a furnace at 1530 °C with a heating rate of 25 °C/min. They were tested in their "as-sintered" form without any additional surface treatment. The fatigue tests were conducted using a four-point bending to obtain the slow crack growth parameters (n). The cyclic fatigue test was also conducted in two frequencies (2 and 10 Hz), using stress levels between 350 and 600 MPa. Data from these tests were analyzed using ASTM C 1368-00 formulas and Weibull statistics. Scanning electron microscope (SEM) was used for fracture surface analysis to identify the origin of the fracture. Critical defect size was measured and used, along with flexural strength values, to estimate fracture toughness. Dynamic fatigue test data were used to obtain subcritical crack growth (SCG) parameters and perform Weibull statistical analysis. The cyclic fatigue data were used in the General Log-linear Model equation using the ALTA PRO software. Data were analyzed using one-way ANOVA followed by Tukey post-hoc tests and Student's t-test at a significance level of p ≤ 0.05. RESULTS: In the dynamic fatigue test, the values obtained for σfo and n were 667 and 54, respectively. This parameter indicates how the strength of the material diminishes over time due to internal cracks. The Weibull parameters obtained from the same test results were m = 7.9, σ0 = 968, 9 and σ5% = 767, which indicates the reliability of the material. The Weibull parameters obtained by cyclic fatigue were statistically similar for the two frequencies used, the m* was 0.17 (2 Hz) and 0.21 (10 Hz); characteristic lifetimes (η) were 1.93 × 106 and 40,768, respectively. The n values obtained by cyclic fatigue were 48 and 40 at frequencies of 2 and 10 Hz, respectively. There was no effect of the frequency, the stress level or the interaction of the two in the Y-TZP lifetime, when analysed by General Log Linear Model. SIGNIFICANCE: the n values obtained by cyclic and dynamic fatigue tests showed no statistically significant difference and the effect of frequency in the characteristic lifetime and the existence of interaction between the cyclic fatigue and subcritical growth were not observed in the tested specimens.


Assuntos
Porcelana Dentária , Resistência à Flexão , Reprodutibilidade dos Testes , Teste de Materiais , Análise do Estresse Dentário , Zircônio , Propriedades de Superfície , Cerâmica , Ítrio
17.
J Adhes Dent ; 26(1): 53-64, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38329120

RESUMO

PURPOSE: This study investigated and compared the bond strengths, microleakage, microgaps, and marginal adaptation of self-adhesive resin composites (SAC) to dentin with or without universal adhesives. MATERIALS AND METHODS: Dentin surfaces of 75 molars were prepared for shear and microtensile bond strength testing (SBS and µTBS). Silicon molds were used to build up direct restorations using the following materials to form 5 groups: 1. Surefil One; 2. Prime&Bond active Universal Adhesive + Surefil One; 3. Vertise Flow; 4. OptiBond Universal + Vertise Flow; 5. Scotchbond Universal + Filtek Z500 (control group). Bonded specimens were thermocycled 10,000x before being tested either for SBS or µTBS using a universal testing machine at a crosshead speed of 0.5 mm/min. Direct mesial and distal class-II cavities were created on 100 sound premolars, with the gingival margin of distal cavities placed below CEJ and restored according to the five groups. After thermocycling, microleakage scores were assessed following immersion of restored premolars in 2% methylene blue dye for 24 h, while marginal gaps and adaptation percentages were investigated on epoxy resin replicas under SEM at magnifications of 2000X and 200X, respectively. Results were statistically analyzed with parametric and non-parametric tests as applicable, with a level of significance set at α = 0.05. RESULTS: Bond strengths, microleakage scores, microgaps, and percent marginal adaptation of Surefil One and Vertise Flow were significantly (p < 0.001) inferior to the control group. Dentin preconditioning with universal adhesives significantly increased the study parameter outcomes of Surefil One and Vertise Flow, yet they were still significantly below the performance of the control group. CONCLUSION: Conventional resin composite outperformed the SAC whether applied solely or in conjunction with their corresponding universal adhesives.


Assuntos
Colagem Dentária , Cimentos de Resina , Bis-Fenol A-Glicidil Metacrilato/química , Cimentos de Resina/química , Adesivos Dentinários/química , Restauração Dentária Permanente/métodos , Cimentos Dentários , Dentina , Resinas Compostas/química , Teste de Materiais
18.
J Funct Biomater ; 14(5)2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37233377

RESUMO

The development of 3D-printed crown resin materials with improved mechanical and physical properties is an area of growing interest in dentistry. This study aimed to develop a 3D-printed crown resin material modified with zirconia glass (ZG) and glass silica (GS) microfillers to enhance overall mechanical and physical properties. A total of 125 specimens were created and divided into five groups: control unmodified resin, 5% either ZG or GS reinforced 3D-printed resin, and 10% either ZG or GS reinforced 3D-printed resin. The fracture resistance, surface roughness, and translucency parameter were measured, and fractured crowns were studied under a scanning electron microscope. The results showed that 3D-printed parts that were strengthened with ZG and GS microfillers demonstrated comparable mechanical performance to unmodified crown resin but resulted in greater surface roughness, and only the group that contained 5% ZG showed an increase in translucency. However, it should be noted that increased surface roughness may impact the aesthetics of the crowns, and further optimisation of microfillers concentrations may be necessary. These findings suggest that the newly developed dental-based resins that incorporate microfillers could be suitable for clinical applications, but further studies are necessary to optimise the nanoparticle concentrations and investigate their long-term clinical outcomes.

19.
Materials (Basel) ; 16(12)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37374547

RESUMO

BACKGROUND: The creation of the denture base material with bioactive properties that releases ions and produces hydroxyapatite. METHODS: Acrylic resins were modified by the addition of 20% of four types of bioactive glasses by mixing with powders. Samples were subjected to flexural strength (1, 60 days), sorption and solubility (7 days), and ion release at pH 4 and pH 7 for 42 days. Hydroxyapatite layer formation was measured using infrared. RESULTS: Biomin F glass-containing samples release fluoride ions for a period of 42 days (pH = 4; Ca = 0.62 ± 0.09; P = 30.47 ± 4.35; Si = 22.9 ± 3.44; F = 3.1 ± 0.47 [mg/L]). The Biomin C (contained in the acrylic resin releases (pH = 4; Ca = 41.23 ± 6.19; P = 26.43 ± 3.96; Si = 33.63 ± 5.04 [mg/L]) ions for the same period of time. All samples have a flexural strength greater than 65 MPa after 60 days. CONCLUSION: The addition of partially silanized bioactive glasses allows for obtaining a material that releases ions over a longer period of time. CLINICAL SIGNIFICANCE: This type of material could be used as a denture base material, helping to preserve oral health by preventing the demineralization of the residual dentition through the release of appropriate ions that serve as substrates for hydroxyapatite formation.

20.
Polymers (Basel) ; 15(11)2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37299322

RESUMO

This study aimed to assess the mechanical and biocompatibility properties of dental resin reinforced with different nanoparticle additives. Temporary crown specimens were 3D-printed and grouped based on nanoparticle type and amount, including zirconia and glass silica. Flexural strength testing evaluated the material's ability to withstand mechanical stress using a three-point bending test. Biocompatibility was tested using MTT and dead/live cell assays to assess effects on cell viability and tissue integration. Fractured specimens were analysed using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) for fracture surface examination and elemental composition determination. Results show that adding 5% glass fillers and 10-20% zirconia nanoparticles significantly improves the flexural strength and biocompatibility of the resin material. Specifically, the addition of 10%, 20% zirconia, and 5% glass silica by weight significantly increases the flexural strength of the 3D-printed resins. Biocompatibility testing reveals cell viabilities greater than 80% in all tested groups. Reinforced 3D-printed resin holds clinical potential for restorative dentistry, as zirconia and glass fillers have been shown to enhance mechanical and biocompatibility properties of dental resin, making it a promising option for dental restorations. The findings of this study may contribute to the development of more effective and durable dental materials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA