Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; : e14435, 2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38922754

RESUMO

PURPOSE: A higher minimum monitor unit (minMU) for pencil-beam scanning proton beams in intensity-modulated proton therapy is preferred for more efficient delivery. However, plan quality may be compromised when the minMU is too large. This study aimed to identify the optimal minMU (OminMU) to improve plan delivery efficiency while maintaining high plan quality. METHODS: We utilized clinical plans including six anatomic sites (brain, head and neck, breast, lung, abdomen, and prostate) from 23 patients previously treated with the Varian ProBeam system. The minMU of each plan was increased from the current clinical minMU of 1.1 to 3-24 MU depending on the daily prescribed dose (DPD). The dosimetric parameters of the plans were evaluated for consistency against a 1.1-minMU plan for target coverage as well as organs-at-risk dose sparing. DPD/minMU was defined as the ratio of DPD to minMU (cGy/MU) to find the OminMU by ensuring that dosimetric parameters did not differ by >1% compared to those of the 1.1-minMU plan. RESULTS: All plans up to 5 minMU showed no significant dose differences compared to the 1.1-minMU plan. Plan qualities remained acceptable when DPD/minMU ≥35 cGy/MU. This suggests that the 35 cGy/MU criterion can be used as the OminMU, which implies that 5 MU is the OminMU for a conventional fraction dose of 180 cGy. Treatment times were decreased by an average of 32% (max 56%, min 7%) and by an average of 1.6 min when the minMU was increased from 1.1 to OminMU. CONCLUSION: A clinical guideline for OminMU has been established. The minMU can be increased by 1 MU for every 35 cGy of DPD without compromising plan quality for most cases analyzed in this study. Significant treatment time reduction of up to 56% was observed when the suggested OminMU is used.

2.
Head Neck ; 45(5): 1088-1096, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36840723

RESUMO

BACKGROUND: To determine if the extent of high-dose gross tumor volume (GTV) to clinical target volume (CTV) expansion is associated with local control in patients with p16-positive oropharynx cancer (p16+ OPC) treated with definitive intensity modulated proton therapy (IMPT). METHODS: We performed a retrospective analysis of patients with p16+ OPC treated with IMPT at a single institution between 2016 and 2021. Patients with a pre-treatment PET-CT and restaging PET-CT within 4 months following completion of IMPT were analyzed. RESULTS: Sixty patients were included for analysis with a median follow-up of 17 months. The median GTV to CTV expansion was 5 mm (IQR: 2 mm). Thirty-three percent of patients (20 of 60) did not have a GTV to CTV expansion. There was one local failure within the expansion group (3%). CONCLUSION: Excellent local control was achieved using IMPT for p16+ OPC independent of GTV expansion. IMPT with minimal target expansions represent a potential harm-minimization technique for p16-positive oropharynx cancer.


Assuntos
Neoplasias Orofaríngeas , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Terapia com Prótons/métodos , Estudos Retrospectivos , Carga Tumoral , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Dosagem Radioterapêutica , Neoplasias Orofaríngeas/etiologia , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA