Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Crit Care ; 27(1): 361, 2023 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-37730622

RESUMO

INTRODUCTION: Prediction of fluid responsiveness in acutely ill patients might be influenced by a number of clinical and technical factors. We aim to identify variables potentially modifying the operative performance of fluid responsiveness predictors commonly used in clinical practice. METHODS: A sensitive strategy was conducted in the Medline and Embase databases to search for prospective studies assessing the operative performance of pulse pressure variation, stroke volume variation, passive leg raising (PLR), end-expiratory occlusion test (EEOT), mini-fluid challenge, and tidal volume challenge to predict fluid responsiveness in critically ill and acutely ill surgical patients published between January 1999 and February 2023. Adjusted diagnostic odds ratios (DORs) were calculated by subgroup analyses (inverse variance method) and meta-regression (test of moderators). Variables potentially modifying the operative performance of such predictor tests were classified as technical and clinical. RESULTS: A total of 149 studies were included in the analysis. The volume used during fluid loading, the method used to assess variations in macrovascular flow (cardiac output, stroke volume, aortic blood flow, volume‒time integral, etc.) in response to PLR/EEOT, and the apneic time selected during the EEOT were identified as technical variables modifying the operative performance of such fluid responsiveness predictor tests (p < 0.05 for all adjusted vs. unadjusted DORs). In addition, the operative performance of fluid responsiveness predictors was also influenced by clinical variables such as the positive end-expiratory pressure (in the case of EEOT) and the dose of norepinephrine used during the fluid responsiveness assessment for PLR and EEOT (for all adjusted vs. unadjusted DORs). CONCLUSION: Prediction of fluid responsiveness in critically and acutely ill patients is strongly influenced by a number of technical and clinical aspects. Such factors should be considered for individual intervention decisions.


Assuntos
Aorta , Humanos , Estudos Prospectivos , Pressão Sanguínea , Débito Cardíaco , Bases de Dados Factuais
2.
J Intensive Care Med ; 33(4): 227-240, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28506136

RESUMO

Management with intravenous fluids can improve cardiac output in some surgical patients. Management with static preload indicators, such as central venous pressure and pulmonary artery occlusion pressure, has not demonstrated a suitable relationship with changes in the cardiac output induced by intravenous fluid therapy. Dynamic indicators, such as the variability of arterial pulse pressure or stroke volume variation, have demonstrated a suitable relationship. Since improvement in cardiac output does not guarantee an adequate perfusion pressure, in patients with hypotension, it is also necessary to know whether arterial pressure will also increase with intravenous fluid therapy. In this regard, the functional assessment of arterial load by dynamic arterial elastance could help to determine which patients will improve not only their cardiac output but also their mean arterial pressure.


Assuntos
Débito Cardíaco/fisiologia , Doenças Cardiovasculares/terapia , Cuidados Críticos , Hidratação , Ressuscitação , Doenças Cardiovasculares/fisiopatologia , Estado Terminal , Hemodinâmica , Humanos , Valor Preditivo dos Testes , Volume Sistólico
3.
BMJ Open ; 14(8): e086388, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39117412

RESUMO

INTRODUCTION: The dynamic arterial elastance (EaDyn), calculated as pulse pressure variation divided by stroke volume variation, has been studied as a predictor of vasopressor weaning. However, its potential as a haemodynamic tool for tapering off vasopressors in patients with sepsis remains unexplored. Therefore, our study aimed to assess whether using EaDyn for weaning vasopressor support could reduce the duration of vasopressor support in patients with sepsis. METHODS AND ANALYSIS: This pragmatic single-centre controlled clinical trial will take place at Fundación Santa Fe de Bogotá, Colombia. Adult patients diagnosed with septic shock according to the sepsis-3 criteria and a Sequential Organ Failure Assessment score ≥4 will be included. A total of 114 patients (57 per group) will undergo conventional critical care monitoring, and the weaning of vasopressor support will be initiated based on the EaDyn or mean arterial pressure (MAP), depending on the assigned group. EaDyn will be estimated based on the measurements obtained from a PiCCO device connected to a PulsioFlex Monitoring Platform (PULSION Medical Systems SE, Feldkirchen, Germany). Our primary outcome is the difference in vasopressor support duration between the EaDyn and MAP groups.Participants and statisticians performing the statistical analysis will be blinded to the group allocation. Dependent and independent variables will be analysed through univariate and multivariate statistical tests. Since we will perform three repeated measurements for analysis, we will implement a Bonferroni post hoc correction. Additionally, Cox regression and Kaplan-Meier analyses will be conducted to address objectives related to time. ETHICS AND DISSEMINATION: This study was approved by the Ethics Committee at Fundación Santa Fe de Bogotá (CCEI-16026-2024). Written informed consent will be obtained from all participants. The results will be disseminated through publication in peer-reviewed journals and presentations at national and international events. TRIAL REGISTRATION NUMBER: NCT06118775.


Assuntos
Choque Séptico , Vasoconstritores , Humanos , Choque Séptico/tratamento farmacológico , Choque Séptico/fisiopatologia , Vasoconstritores/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Volume Sistólico , Masculino , Colômbia , Feminino , Pressão Arterial/efeitos dos fármacos , Cuidados Críticos/métodos , Adulto
4.
Ann Intensive Care ; 14(1): 108, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38980442

RESUMO

BACKGROUND: Dynamic arterial elastance (Eadyn) has been investigated for its ability to predict hypotension during the weaning of vasopressors. Our study focused on assessing Eadyn's performance in the context of critically ill adult patients admitted to the intensive care unit, regardless of diagnosis. MAIN BODY: Our study was conducted in accordance with the Preferred Reported Items for Systematic Reviews and Meta-Analysis checklist. The protocol was registered in PROSPERO (CRD42023421462) on May 26, 2023. We included prospective observational studies from the MEDLINE and Embase databases through May 2023. Five studies involving 183 patients were included in the quantitative analysis. We extracted data related to patient clinical characteristics, and information about Eadyn measurement methods, results, and norepinephrine dose. Most patients (76%) were diagnosed with septic shock, while the remaining patients required norepinephrine for other reasons. The average pressure responsiveness rate was 36.20%. The synthesized results yielded an area under the curve of 0.85, with a sensitivity of 0.87 (95% CI 0.74-0.93), specificity of 0.76 (95% CI 0.68-0.83), and diagnostic odds ratio of 19.07 (95% CI 8.47-42.92). Subgroup analyses indicated no variations in the Eadyn based on norepinephrine dosage, the Eadyn measurement device, or the Eadyn diagnostic cutoff to predict cessation of vasopressor support. CONCLUSIONS: Eadyn, evaluated through subgroup analyses, demonstrated good predictive ability for the discontinuation of vasopressor support in critically ill patients.

5.
Sci Rep ; 12(1): 2590, 2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-35173214

RESUMO

Several limitations regarding pulse pressure variation (PPV) use have been reported. Our aim was to describe changes in the PPV operative performance as a predictor of fluid responsiveness during the development of a swine endotoxin shock model and to assess hemodynamic variables associated with PPV changes. A swine porcine endotoxin shock model was established (Escherichia Coli 055:B5 endotoxin) in 7 pigs, and 3 pigs were included in the control group. The endotoxin was infused until the mean arterial pressure (MAP) dropped below 50 mmHg (TH0); then, the model animal was reanimated with fluids and vasopressors. We performed fluid challenges every hour for 6 h. ROC curve analysis and a linear mixed model were performed. The area under the curve of PPV decreased from 0.95 (0.81-1.00) to 0.60 (0.17-1.00) at TH0. Its cutoff increased from 10.5 to 22.00% at TH0. PPV showed an inverse relationship with stroke volume, mean systemic filling pressure, MAP, and systemic vascular resistance (SVR) (p < 0.001, AIC = 111.85). The PPV operative performance as a predictor of fluid responsiveness decreased with the progression of shock. This could lead to an inverse association between PPV and the following variables: MAP and SVR.


Assuntos
Pressão Sanguínea/fisiologia , Choque Séptico/fisiopatologia , Animais , Pressão Arterial , Modelos Animais de Doenças , Feminino , Hemodinâmica , Curva ROC , Suínos , Resistência Vascular
6.
Ann Intensive Care ; 11(1): 28, 2021 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-33555488

RESUMO

INTRODUCTION: Dynamic predictors of fluid responsiveness have shown good performance in mechanically ventilated patients at tidal volumes (Vt) > 8 mL kg-1. Nevertheless, most critically ill conditions demand lower Vt. We sought to evaluate the operative performance of several predictors of fluid responsiveness at Vt ≤ 8 mL kg-1 by using meta-regression and subgroup analyses. METHODS: A sensitive search was conducted in the Embase and MEDLINE databases. We searched for studies prospectively assessing the operative performance of pulse pressure variation (PPV), stroke volume variation (SVV), end-expiratory occlusion test (EEOT), passive leg raising (PLR), inferior vena cava respiratory variability (Δ-IVC), mini-fluid challenge (m-FC), and tidal volume challenge (VtC), to predict fluid responsiveness in adult patients mechanically ventilated at Vt ≤ 8 ml kg-1, without respiratory effort and arrhythmias, published between 1999 and 2020. Operative performance was assessed using hierarchical and bivariate analyses, while subgroup analysis was used to evaluate variations in their operative performance and sources of heterogeneity. A sensitivity analysis based on the methodological quality of the studies included (QUADAS-2) was also performed. RESULTS: A total of 33 studies involving 1,352 patients were included for analysis. Areas under the curve (AUC) values for predictors of fluid responsiveness were: for PPV = 0.82, Δ-IVC = 0.86, SVV = 0.90, m-FC = 0.84, PLR = 0.84, EEOT = 0.92, and VtC = 0.92. According to subgroup analyses, variations in methods to measure cardiac output and in turn, to classify patients as responders or non-responders significantly influence the performance of PPV and SVV (p < 0.05). Operative performance of PPV was also significantly affected by the compliance of the respiratory system (p = 0.05), while type of patient (p < 0.01) and thresholds used to determine responsiveness significantly affected the predictability of SVV (p = 0.05). Similarly, volume of fluids infused to determine variation in cardiac output, significantly affected the performance of SVV (p = 0.01) and PLR (p < 0.01). Sensitivity analysis showed no variations in operative performance of PPV (p = 0.39), SVV (p = 0.23) and EEOT (p = 0.15). CONCLUSION: Most predictors of fluid responsiveness reliably predict the response of cardiac output to volume expansion in adult patients mechanically ventilated at tidal volumes ≤ 8 ml kg-1. Nevertheless, technical and clinical variables might clearly influence on their operative performance.

7.
Clin Med Insights Circ Respir Pulm Med ; 14: 1179548420901518, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32047358

RESUMO

INTRODUCTION: Pulse pressure variation (PPV) has been shown to be useful to predict fluid responsiveness in patients ventilated at tidal volume (Vt) >8 mL kg-1. Nevertheless, most conditions in critical care force to use lower Vt. Thus, we sought to evaluate the operative performance of PPV when a Vt ⩽8 mL kg-1 is used during mechanical ventilation support. METHODS: We searched PubMed and Embase databases for articles evaluating the operative performance of PPV as a predictor of fluid responsiveness in critical care and perioperative adult patients ventilated with tidal volume ⩽8 mL kg-1 without respiratory effort and arrhythmias, between January 1990 and January 2019. We included cohort and cross-sectional studies. Two authors performed an Independently selection using predefined terms of search. The fitted data of sensitivity, specificity, and area under the curve (AUC) were assessed by bivariate and hierarchical analyses. RESULTS: We retrieved 19 trials with a total of 777 patients and a total of 935 fluid challenges. The fitted sensitivity of PPV to predict fluid responsiveness during mechanical ventilation at Vt ⩽8 mL kg-1 was 0.65 (95% confidence interval [CI]: 0.57-0.73), the specificity was 0.79 (95% CI: 0.73-0.84), and the AUC was 0.75. The diagnostic odds ratio was 5.5 (95% CI: 3.08-10.01, P < .001) by the random-effects model. CONCLUSIONS: Pulse pressure variation shows a fair operative performance as a predictor of fluid responsiveness in critical care and perioperative patients ventilated with a tidal volume ⩽8 mL kg-1 without respiratory effort and arrhythmias.

9.
Repert. med. cir ; 33(2): 178-185, 2024. tab, graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1561074

RESUMO

Introducción: el reto de líquidos es una prueba que consiste en administrarlos y medir la respuesta hemodinámica mediante el cambio del gasto cardíaco (GC), aunque solo medir el GC resulta insuficiente. El acople ventrículo-arterial (AVA) (elastancia arterial efectiva/ elastancia telesistólica: Eae/Ets) aparece como una variable que evalúa el estado cardiocirculatorio en forma integral. Objetivo: evaluar el AVA en un biomodelo de choque endotóxico y durante retos de líquidos. Materiales y métodos: biomodelo de choque endotóxico (9 porcinos). Se midieron variables hemodinámicas cada hora desde un tiempo 0 (T0) hasta T6. Se realizaron 5 retos de líquidos entre T0 y T4. El tiempo de hipotensión se denominó TH0. Se calcularon diferencias de medianas de variables entre T0-T4. Se clasificaron los retos en dos grupos según el delta del AVA (AVA posreto-AVA prerreto), en ΔAVA≤0 o >0, se midieron variables antes y después de cada reto. Se determinó la relación lactato/piruvato (L/P) en T0, T3 y T6, se establecieron correlaciones entre la diferencia LP T6-T0 y de variables hemodinámicas. Resultados: el AVA aumentó (1.58 a 2,02, p=0.042) por incremento en la Eae (1.74 a 2,55; p=0.017). El grupo ΔAVA≤0 elevó el GC (4.32 a 5,46, p=0.032) y el poder cardíaco (PC) (0.61 a 0,77, p=0,028). El Δ L/P se correlacionó con el Δ del índice de choque sistólico y diastólico (r=0.73), pero no con el del AVA. Conclusión: durante el choque endotóxico el AVA aumentó de manera significativa. Durante el reto de líquidos el grupo Δ AVA≤0, elevó el GC y PC. El Δ L/P no se correlacionó con variables del AVA.


Introduction: fluid challenges (FCs) consist of measuring hemodynamic response through changes in cardiac output (CO) after fluid administration, although only measuring CO proves insufficient. Ventriculo-arterial coupling (V-A) (effective arterial elastance / tele-systolic elastance: E(a)/Ets) are variables used for a comprehensive cardiac and circulatory status appraisal. Objective: to evaluate V-A in an endotoxic shock bio-model by FCs. Materials and methods: an endotoxic shock bio-model (9 pigs). Hemodynamic variables were measured every hour from time 0 (T0) to T6. Five FCs were performed between T0 and T4. Hypotension time was referred to as HT. The median differences in variables between T0-T4 were calculated. Challenges were classified into two groups according to V-A delta (post-challenge V-A - pre-challenge V-A). In ΔV-A≤0 o>0, variables were measured before and after each FC. The lactate to pyruvate (L/P) ratio was determined at T0, T3 and T6. Correlations between the LP T6-T0 difference and hemodynamic variables, were established. Results: V-A increased (1.58 to 2,02, p=0.042) as Eae increased (1.74 to 2.55; p=0.017). CO (4.32 to 5.46, p=0.032) and cardiac power (CP) (0.61 to 0.77, p=0,028) increased, in the ΔV-AC≤0 group. The ΔLP correlated with the systolic and diastolic shock index (r=0.73), but not with V-A. Conclusion: V-A increased significantly during endotoxic shock. The ΔAVA≤0 group, showed elevated CO and CP during FC. ΔLP did not correlate with any of the V-A variables.


Assuntos
Humanos , Sepse , Endotoxemia
10.
Rev. colomb. anestesiol ; 43(3): 214-218, July-Sept. 2015.
Artigo em Inglês | LILACS, COLNAL | ID: lil-757257

RESUMO

Introduction: The passive leg raising test (PLR) allows physicians to determine which patients require treatment with intravenous fluids. Objectives: It is important to be aware of tools that help us to determine the response to the passive leg raising test, as well as understanding in which clinical situations it can be performed. Materials and methods: Non-systematic review. Medline and PubMed databases were consulted in search of relevant articles. Results: Through echocardiography, pulse pressure and capnography can be determined as a response to leg raising. Conclusions: This article explores the tools that are useful in determining the response to this maneuver, and the clinical conditions in which it is indicated.


Introducción: la prueba de elevación de piernas pasivas permite determinar en qué paciente se requiere manejo con líquidos endovenosos. Objetivos: es importante conocer las herramientas que ayudan a determinar la respuesta a la prueba de elevación de piernas pasiva, además conocer en qué situaciones clínicas se puede realizar. Materiales y métodos: revisión no sistemática. Se consultaron las siguientes bases de datos Medline y Pubmed, en búsqueda de artículos relevantes. Resultados: mediante ecocardiografía, presión de pulso y capnografía se puede determinar la respuesta a la elevación de piernas. Conclusiones: el presente artículo explora las herramientas que son útiles para determinar la respuesta a esta maniobra y las condiciones clínicas donde se indica.


Assuntos
Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA