Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circ J ; 88(9): 1472-1477, 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-38910134

RESUMO

BACKGROUND: The incidence and prognostic predictors of heart failure (HF) without left ventricular systolic dysfunction (LVSD) in hypertrophic cardiomyopathy (HCM), particularly their differences in terms of developing LVSD (progression to end-stage) or sudden cardiac death (SCD), are not fully elucidated. METHODS AND RESULTS: This study included 330 consecutive HCM patients with left ventricular ejection fraction (LVEF) ≥50%. HF hospitalization without LVSD and development of LVSD were evaluated as main outcomes. During a median follow-up of 7.3 years, the incidence of HF hospitalization without LVSD was 18.8%, which was higher than the incidence of developing LVSD (10.9%) or SCD (8.8%). Among patients who developed LVSD, only 19.4% experienced HF hospitalization without LVSD before developing LVSD. Multivariable analysis showed that predictors for HF hospitalization without LVSD (higher age, atrial fibrillation, history of HF hospitalization, and higher B-type natriuretic peptide concentrations) were different from those of developing LVSD (male sex, lower LVEF, lower left ventricular outflow tract gradient, and higher tricuspid regurgitation pressure gradient). Known risk factors for SCD did not predict either HF without LVSD or developing LVSD. CONCLUSIONS: In HCM with LVEF ≥50%, HF hospitalization without LVSD was more frequently observed than development of LVSD or SCD during mid-term follow-up. The overlap between HF without LVSD and developing LVSD was small (19.4%), and these 2 HF events had different predictors.


Assuntos
Cardiomiopatia Hipertrófica , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Masculino , Feminino , Cardiomiopatia Hipertrófica/fisiopatologia , Cardiomiopatia Hipertrófica/complicações , Pessoa de Meia-Idade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/epidemiologia , Idoso , Disfunção Ventricular Esquerda/fisiopatologia , Progressão da Doença , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Seguimentos , Hospitalização , Fatores de Risco , Incidência , Volume Sistólico , Adulto
2.
BMC Cardiovasc Disord ; 23(1): 281, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37264308

RESUMO

BACKGROUND: Recent studies have reported atrial involvement and coexistence of aortic stenosis in transthyretin (ATTR) cardiac amyloidosis (CA). However, pathological reports of extraventricular ATTR amyloid deposits in atrial structures or heart valves are limited, and the clinical implications of ATTR amyloid deposits outside the ventricles are not fully elucidated. CASE PRESENTATION: We report 3 cases of extraventricular ATTR amyloid deposits confirmed in surgically resected aortic valves and left atrial structures, all of which were unlikely to have significant ATTR amyloidosis infiltrating the ventricles as determined by multimodality evaluation including 99mtechnetium-pyrophosphate scintigraphy, cardiac magnetic resonance, endomyocardial biopsy and their mid-term clinical course up to 5 years. These findings suggested that these were extraventricular ATTR amyloid deposits localized in the aortic valve and the left atrium. CONCLUSIONS: While long-term observation is required to fully clarify whether these extraventricular ATTR amyloid deposits are truly localized outside the ventricles or are early stages of ATTR-CA infiltrating the ventricles, our 3 cases with multimodality evaluations and mid-term follow up suggest the existence of extraventricular ATTR amyloid deposits localized in the aortic valve and left atrial structures.


Assuntos
Neuropatias Amiloides Familiares , Fibrilação Atrial , Cardiomiopatias , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Neuropatias Amiloides Familiares/diagnóstico por imagem , Seguimentos , Placa Amiloide , Pré-Albumina/genética , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Cardiomiopatias/diagnóstico por imagem
3.
Heart Vessels ; 38(6): 785-792, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36802023

RESUMO

Risk prediction for heart failure (HF) using machine learning methods (MLM) has not yet been established at practical application levels in clinical settings. This study aimed to create a new risk prediction model for HF with a minimum number of predictor variables using MLM. We used two datasets of hospitalized HF patients: retrospective data for creating the model and prospectively registered data for model validation. Critical clinical events (CCEs) were defined as death or LV assist device implantation within 1 year from the discharge date. We randomly divided the retrospective data into training and testing datasets and created a risk prediction model based on the training dataset (MLM-risk model). The prediction model was validated using both the testing dataset and the prospectively registered data. Finally, we compared predictive power with published conventional risk models. In the patients with HF (n = 987), CCEs occurred in 142 patients. In the testing dataset, the substantial predictive power of the MLM-risk model was obtained (AUC = 0.87). We generated the model using 15 variables. Our MLM-risk model showed superior predictive power in the prospective study compared to conventional risk models such as the Seattle Heart Failure Model (c-statistics: 0.86 vs. 0.68, p < 0.05). Notably, the model with an input variable number (n = 5) has comparable predictive power for CCE with the model (variable number = 15). This study developed and validated a model with minimized variables to predict mortality more accurately in patients with HF, using a MLM, than the existing risk scores.


Assuntos
Inteligência Artificial , Insuficiência Cardíaca , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Prognóstico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Algoritmos
4.
Circ J ; 86(3): 393-401, 2022 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-35125372

RESUMO

BACKGROUND: Transaortic transcatheter aortic valve replacement (TAo-TAVR) is an alternative to peripheral or transapical TAVR. The procedural feasibility, safety, and midterm outcomes of TAo-TAVR were investigated in this study.Methods and Results:Eighty-four consecutive patients underwent TAo-TAVR from 2011 to 2021. Their median age was 83 years (interquartile range, 80-87 years). The Edwards SAPIEN and Medtronic CoreValve devices were used in 45 (53.6%) and 38 (45.2%) patients, respectively. The surgical approach was a right mini-thoracotomy in 43 patients (51.2%) and partial sternotomy in 4 patients (4.8%). The remaining 37 patients (44.0%) underwent full sternotomy because of concomitant off-pump coronary artery bypass grafting. VARC-3 device success was achieved in 77 patients (91.7%). Valve migration occurred in 3 patients (3.6%) using a first-generation CoreValve device, necessitating implantation of a second valve. No aortic annulus rupture, aortic dissection, or coronary orifice occlusion occurred. Conversion to surgery was required for 1 patient because of uncontrollable bleeding. Only 1 in-hospital death occurred. New pacemaker implantation was required in 6 patients (7.1%). Echocardiography at discharge showed no or trivial paravalvular leak (PVL) in 58 patients (69.0%), mild PVL in 23 (27.4%), and mild to moderate PVL in 2 (2.4%) patients. The 1- and 3-year incidence of cardiovascular death was 1.6% and 4.8%, respectively, with no structural valve deterioration. CONCLUSIONS: TAo-TAVR is feasible and safe with satisfactory midterm outcomes using both currently available devices.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Mortalidade Hospitalar , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
5.
Heart Lung Circ ; 31(12): 1666-1676, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36150952

RESUMO

AIM: This study aimed to evaluate the early and intermediate-term outcomes of patients who underwent concomitant off-pump coronary artery bypass grafting (CABG) and transcatheter aortic valve replacement (TAVR). METHOD: Between January 2014 and June 2021, 49 patients underwent concomitant off-pump CABG and TAVR via median sternotomy (TAVRCAB group) and 143 underwent concomitant on-pump CABG and surgical aortic replacement. Of the 143 patients who underwent on-pump surgery, 80 (SAVRCAB group) were eligible for comparison. The composite event included all-cause death, heart failure rehospitalisation, repeat revascularisation, brain infarction, and repeat aortic valve replacement. RESULTS: The Society of Thoracic Surgeons' predicted risk for mortality and age were higher in the TAVRCAB group than in the SAVRCAB group (7.1% vs 3.1% [p<0.001]; 81 yrs vs 75 years [p<0.001], respectively), while the surgical time was shorter (289 min vs 352 min; p<0.001). There was no conversion to on-pump surgery in the TAVRCAB group. The postoperative maximum creatinine kinase-MB value was lower in the TAVRCAB group. There was no deep sternal wound infection or repeat revascularisation in either group. Hospital death and brain infarction developed in one patient (1.3%) each in the SAVRCAB group, but in no patients in the TAVRCAB group. The rates of freedom from the composite event were similar between the two groups during the follow-up period. CONCLUSIONS: Concomitant off-pump CABG and TAVR would be a less-invasive alternative procedure for treating intermediate or high surgical risk patients with aortic stenosis and coronary artery disease unsuitable for percutaneous coronary intervention.


Assuntos
Estenose da Valva Aórtica , Ponte de Artéria Coronária sem Circulação Extracorpórea , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Valva Aórtica/cirurgia , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia
6.
Echocardiography ; 38(8): 1307-1313, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34286878

RESUMO

PURPOSE: Transthoracic echocardiography (TTE) provides noninvasively quantitative assessment of aortic regurgitation (AR) severity, but its diagnostic accuracy depends on image quality. Two-dimensional transesophageal echocardiography (TEE) is a semi-invasive procedure that is excellent in evaluating AR mechanism. However, quantitative assessment may be challenging due to restrictions in probe manipulation. This study aimed to investigate the diagnostic value of three-dimensional TEE to measure the vena contracta area (3DVCA) of AR. METHODS: The subjects comprised 62 patients (age, 65 ± 16 years) whose AR was evaluated using TEE. The 3DVCA and semi-quantitative TEE parameters, such as the ratio of AR jet width to left ventricular outflow tract (jet/LVOT) and the vena contracta width (VCW) of AR jet, were compared using angiography grade and quantitative TTE measurements including regurgitant volume (RVol) and effective regurgitant orifice area (EROA). The diagnostic accuracy was determined using receiver operating characteristic (ROC) analysis, and the reproducibility of 3DVCA was also evaluated. RESULTS: In 3DVCA, less overlap between angiography grades were observed. Correlation with RVol or EROA was better in 3DVCA than in Jet/LVOT or VCW. The area under the ROC curve was .737 for jet/LVOT, .773 for VCW, and .849 for 3DVCA, respectively. The optimal cutoff value of 3DVCA was ≥.31 cm2 for grading severe AR. Inter- and intra-observer reproducibility of 3DVCA were .92 and .97, respectively. CONCLUSIONS: The 3DVCA method using TEE showed high diagnostic accuracy and reproducibility. 3DVCA deserves use in accurately assessing AR severity, especially in patients who present difficulty in quantitative Doppler assessment using TTE.


Assuntos
Insuficiência da Valva Aórtica , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
7.
Int Heart J ; 62(5): 1019-1025, 2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34544972

RESUMO

The aortic regurgitation (AR) index, proposed as an objective indicator of postprocedural AR, decreases in proportion to AR severity, besides reportedly providing additional prognostic information. Meanwhile, left ventricular (LV) function has also been considered an essential prognostic factor. This study aimed to clarify whether LV function affected the AR index using cardiac catheterization data.A retrospective study was performed in patients whose LV function was evaluated using a micromanometer-tipped catheter. Patients with grade 2 or higher AR were excluded to explore non-AR factors affecting the AR index value. The AR index was calculated as a ratio of the gradient between the aortic diastolic blood pressure (DBP) and the LV end-diastolic pressure (EDP) to the aortic systolic blood pressure (SBP): AR Index = [ (DBP - LVEDP) / SBP] × 100.A total of 64 patients [age, 62 (interquartile range: 48-70) years; LV ejection fraction, 19% (16%-26%) ] were examined. AR index values ranged from 18.3 to 68.6. Despite having no AR, two patients displayed an AR index < 25, indicating significant AR. Multiple-regression analysis revealed that LV diastolic stiffness (ß = -0.750, P < 0.001), LV max dP/dt (ß = -0.296, P = 0.006), and heart rate (ß = 0.284, P = 0.011) were independent determinants of the AR index value.Patients with impaired LV diastolic function and preserved systolic function had low AR index values. The additional prognostic information of the AR index may be related to LV diastolic function.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Hemodinâmica/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/fisiologia , Idoso , Insuficiência da Valva Aórtica/classificação , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Pressão Sanguínea/fisiologia , Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem
8.
Int Heart J ; 60(2): 366-373, 2019 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-30799383

RESUMO

The diffusing capacity of the lung for carbon monoxide (DLCO) is indicative of the alveolar-capillary membrane function. A reduced DLCO is associated with poor prognosis in chronic heart failure (HF). However, the significance of DLCO as an independent prognostic predictor has not been established. Here, we aimed to determine the prognostic value of DLCO in patients with chronic HF.We enrolled 214 patients (139 females, mean age: 63 ± 16 years, left ventricular ejection fraction [LVEF]: 45 ± 21%) with stable chronic HF who underwent pulmonary function tests. Only never smokers were included in the analysis because smoking can decrease DLCO.During a median follow-up period of 2.1 years, 52 patients (24.3%) experienced cardiac events, including unplanned HF admissions, left ventricular assist device (LVAD) implantations, all-cause deaths, and cardiopulmonary arrests (CPAs). The median percent predicted DLCO (%DLCO) was 87.3%. In a Cox regression analysis, a %DLCO of ≤87.3% was independently associated with the cardiac events, even after adjusting for age, sex, systolic blood pressure (SBP), LVEF, anemia, brain natriuretic peptide, estimated glomerular filtration rate (eGFR), and prior HF admission (hazard ratio [HR]: 1.87, 95% confidence interval: 1.03-3.53, P = 0.030).A reduced DLCO is an independent predictor of poor prognosis in nonsmoking patients with chronic HF.


Assuntos
Monóxido de Carbono/análise , Insuficiência Cardíaca/diagnóstico , Capacidade de Difusão Pulmonar/métodos , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , não Fumantes/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde , Valor Preditivo dos Testes , Prognóstico , Testes de Função Respiratória/métodos , Volume Sistólico
9.
Heart Vessels ; 33(4): 385-392, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29098408

RESUMO

BACKGROUND: Serum Wisteria floribunda agglutinin positive Mac-2 binding protein (WFA+-M2BP) or Mac-2 Binding Protein Glycosylation Isomer (M2BPGi) is a novel biomarker currently applied for evaluating hepatic fibrosis. The aim of this study was to evaluate the utility of serum WFA+-M2BP level as a biomarker in chronic heart failure (HF) patients with abnormal liver function. METHODS AND RESULTS: Fifty chronic HF patients who underwent measurement of serum WFA+-M2BP were evaluated. The median value of serum WFA+-M2BP was 0.88 (interquartile range 0.48-1.29) cut-off index, and positive WFA+-M2BP (≥ 1.00 cut-off index) was observed in 22 (44%). Elevated WFA + -M2BP was associated with longer HF history, older age, female sex, valvular heart disease, decreased estimated glomerular filtration rate (eGFR), albumin, and cholinesterase. Stepwise multiple regression analysis showed that HF history, eGFR, and albumin were independent determinants of serum WFA+-M2BP values. Repeated measurements of serum WFA+-M2BP suggested association between the decrease of WFA+-M2BP and improvement of New York Heart Association (NYHA) functional class. CONCLUSIONS: Elevation of serum WFA+-M2BP showed a high prevalence in chronic HF patients with abnormal liver function with relation to HF history, decreased hepatic protein synthesis, and renal dysfunction. Our results suggest that serum WFA+-M2BP may be a novel biomarker of chronic HF.


Assuntos
Antígenos de Neoplasias/sangue , Insuficiência Cardíaca/sangue , Glicoproteínas de Membrana/sangue , Lectinas de Plantas/sangue , Receptores de N-Acetilglucosamina/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Ecocardiografia , Feminino , Glicosilação , Insuficiência Cardíaca/diagnóstico , Humanos , Técnicas Imunoenzimáticas , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Índice de Gravidade de Doença
10.
Circ J ; 82(1): 131-140, 2017 12 25.
Artigo em Inglês | MEDLINE | ID: mdl-28740056

RESUMO

BACKGROUND: Surgical treatment of functional mitral regurgitation (FMR) improves ventricular remodeling in patients with dilated cardiomyopathy (DCM). However, it is unclear whether surgical treatment improves long-term outcomes. We investigated the effects of mitral valve (MV) surgery in patients with DCM and FMR.Methods and Results:Of 525 patients with DCM hospitalized due to heart failure between January 1996 and September 2014, 70 who had severe FMR despite receiving optimal medical therapy were enrolled in the study. Of these patients, 16 underwent surgery for FMR (surgery group; repair=14, replacement=2); the remaining 54 who refused or decided not to undergo surgery were classified as the medication group. There were no differences in age, sex, medication, or echocardiographic parameters between the 2 groups (P>0.05). During the mean follow-up period of 53.6±43.6 months, the occurrence of clinical outcomes (i.e., all-cause death or left ventricular assist device implantation) was 54.3%; the occurrence of clinical outcomes was lower in the surgery group (P=0.008, log-rank test). Multivariate Cox regression analysis using clinical data revealed that MV surgery (hazard ratio [HR] 0.257, 95% confidence interval [CI] 0.103-0.640; P=0.004) and diabetes mellitus (HR 2.924, 95% CI 1.243-6.876; P=0.014) were independent predictors of clinical outcomes after adjusting for age and sex. CONCLUSIONS: Surgery for severe FMR provides better long-term outcomes in patients with DCM.


Assuntos
Cardiomiopatia Dilatada/cirurgia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Fatores de Risco , Resultado do Tratamento
11.
Circ J ; 81(8): 1116-1122, 2017 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-28321004

RESUMO

BACKGROUND: The MitraClip®system is a transcatheter-based therapeutic option for patients with chronic mitral regurgitation (MR) who are at high risk for surgery. A prospective, multicenter, single-arm study was initiated to confirm the transferability of this system to Japan.Methods and Results:Patients with symptomatic chronic moderate-to-severe (3+) or severe (4+) functional or degenerative MR with a Society of Thoracic Surgery (STS) score ≥8%, or the presence of 1 predefined risk factor were enrolled. Patients with left ventricular (LV) ejection fraction (EF) <30% were excluded. MR severity and LV function were assessed by an independent echocardiography core lab. Primary outcome included major adverse events (MAE) at 30 days and acute procedural success (APS). A total of 30 patients (age: 80±7 years; STS score: 10.3%±6.6%) were treated with the MitraClip®. At baseline, all patients had MR 3+/4+ with 53%/47% patients with degenerative/functional etiology with mean LVEF of 50.2±12.8%, and 37% of patients were NYHA class III/IV. APS was achieved in 86.7% with no occurrence of MAE. At 30 days, 86.7% of patients had MR ≤2+ and 96.7% were NYHA class I/II. CONCLUSIONS: The MitraClip®procedure resulted in clinically meaningful improvements in MR severity, function and quality of life measures, and low MAE rates. These early results suggest the transferability of this therapy to appropriately selected Japanese patients. (Trial Registration: clinicaltrials.gov Identifier NCT02520310.).


Assuntos
Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Doença Crônica , Feminino , Humanos , Japão , Masculino , Estudos Prospectivos , Fatores de Risco
12.
Circ J ; 82(1): 289-292, 2017 12 25.
Artigo em Inglês | MEDLINE | ID: mdl-29129879

RESUMO

BACKGROUND: The valve-in-valve procedure, in which a transcatheter heart valve (THV) is implanted over a prosthetic valve, has been shown to be safe and therapeutically effective, depending on the size of the replacement valve.Methods and Results:We report 3 cases of successful valve-in-valve procedure to replace a degenerated 19-mm stented prosthetic aortic valve. Balloon-expanding THVs were implanted: 20-mm in the 1st case and 23-mm in the next 2. Aortic stenosis was almost completely resolved in all patients, who recovered promptly and without cardiac adverse events. CONCLUSIONS: Using the valve-in-valve procedure for a 19-mm degenerated bioprosthesis was feasible and safe.


Assuntos
Bioprótese , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/terapia , Ecocardiografia , Feminino , Humanos , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
13.
Circ J ; 81(1): 22-27, 2016 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-27941303

RESUMO

The American Heart Association (AHA) Scientific Sessions 2016 were held on November 12-16 at the Ernest N. Morial Convention Center, New Orleans, LA. This 5-day event featured cardiovascular clinical practice covering all aspects of basic, clinical, population, and translational content. One of the hot topics at AHA 2016 was precision medicine. The key presentations and highlights from the AHA Scientific Sessions 2016, including "precision medicine" as one of the hot topics, are herein reported.


Assuntos
American Heart Association , Congressos como Assunto , Pesquisa Translacional Biomédica , Humanos , Nova Orleans , Estados Unidos
14.
Circ J ; 80(9): 1946-50, 2016 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-27498901

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become an alternative procedure for treating aortic stenosis (AS) in patients with advanced age and severe comorbidities. Ischemic heart disease (IHD) is present with AS in 40-50% of patients with typical angina. Considering the high operative mortality and morbidity rates in these patients, hybrid TAVI and off-pump CABG (OPCAB) have become realistic treatment options. METHODS AND RESULTS: Between August 2014 and November 2015, 12 patients were evaluated for simultaneous TAVI and OPCAB. Because of their advanced age and comorbidities these patients were not considered suitable for standard open heart surgery. PCI was also considered unsuitable, because of left anterior descending artery (LAD) proximal lesions and/or high SYNTAX score. TAVI was conducted through a median sternotomy after left internal thoracic artery (LITA) to LAD anastomosis. In 11 cases OPCAB with LITA and composite RA graft was performed using an aorta no-touch technique. Mean age at operation was 81±6.3 years. Average number of distal anastomoses was 2.6. Perivalvular leakage was mild in 3 patients, trivial in 8, and none in 1. There was no conversion to on-pump procedure and no hospital deaths. CONCLUSIONS: Simultaneous transaortic TAVI and OPCAB in high-risk patients with severe AS and IHD is a reasonable option. This method could be an alternative to surgical aortic valve replacement and CABG. (Circ J 2016; 80: 1946-1950).


Assuntos
Estenose da Valva Aórtica , Isquemia Miocárdica , Revascularização Miocárdica/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Isquemia Miocárdica/complicações , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/cirurgia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos
16.
Heart Vessels ; 31(6): 925-31, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25964073

RESUMO

Although counter-regulation between B-type natriuretic peptide (BNP) levels and renin-angiotensin-aldosterone system (RAAS) activation in heart failure (HF) has been suggested, whether the regulation is preserved in acute decompensated heart failure (ADHF) patients remains unclear. This study aimed to determine: (1) the relationship between RAAS activation and clinical outcomes in ADHF patients, and (2) the relationships between plasma BNP levels and degrees of activation in RAAS factors. This study included ADHF patients (n = 103, NYHA3-4, plasma BNP > 200 pg/ml). We studied the predictability of RAAS factors for cardiovascular events and the relationships between plasma BNP levels and the degrees of activation in RAAS factors, which were evaluated by plasma renin activity (PRA) and aldosterone concentration (PAC). PRA was a strong predictor of cardiovascular (CV) events over 1 year, even after accounting for plasma BNP levels (hazard ratio (HR): 1.04, CI [1.02-1.06], p < 0.01) and medication such as RAAS blockers (HR: 1.03, CI [1.01-1.05], p < 0.01), whereas PAC was borderline-significant (univariate analysis, p = 0.06). Cut-off value of PRA (5.3 ng/ml/h) was determined by AUC curve. Of the enrolled patients, higher PRA was found in 40 % of them. Although no correlation between the plasma BNP levels and PRA was found (p = 0.36), after adjusting for hemodynamic parameters, eGFR and medication, a correlation was found between them (p = 0.01). Elevated RAAS factors were found in a substantial number of ADHF patients with high plasma BNP levels in the association with hemodynamic state, which predicts poor clinical outcomes. The measurements of RAAS factors help to stratify ADHF patients at risk for further CV events.


Assuntos
Aldosterona/sangue , Insuficiência Cardíaca/terapia , Sistema Renina-Angiotensina , Renina/sangue , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Biomarcadores/sangue , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Resultado do Tratamento , Regulação para Cima
19.
Circ Rep ; 6(5): 151-160, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38736848

RESUMO

Background: Heart failure patients are deficient in B-type natriuretic peptide (BNP) but the significance of subclinical BNP deficiency is unclear. Methods and Results: A total of 1,398 subjects without cardiovascular disease, with left ventricular ejection fraction (LVEF) ≥50% and BNP level <100 pg/mL, were selected from a 2005-2008 health checkup in Arita-cho, Japan, and divided into 2 groups: with and without LV diastolic dysfunction (DD+ or DD-). We performed propensity score matching on non-cardiac factors affecting BNP levels and analyzed 470 subjects in each group (372/940 men; median age, 66 years). The DD(+) group showed higher lateral E/e', an index of estimated left ventricular filling pressure, and greater prevalence of concentric hypertrophy (CH) despite similar BNP levels, suggesting a relative deficiency of BNP in DD(+) compared with DD(-). Multivariable logistic regression analysis revealed an increase in BNP correlated with decreased odds of CH (adjusted odds ratio [aOR] 0.663, 95% confidence interval (CI) 0.484-0.909, P=0.011), whereas an increase in lateral E/e' was associated with increased odds of CH (aOR, 2.881; 95% CI, 1.390-5.973; P=0.004). Furthermore, CH in combination with diastolic dysfunction independently predicted major adverse cardiovascular events (hazard ratio 3.272, 95% CI 1.215-8.809; P=0.019). Conclusions: Relative BNP deficiency was associated with CH, which had a poor prognosis in patients with diastolic dysfunction.

20.
J Cardiol ; 83(3): 169-176, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37543193

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) for severe symptomatic aortic stenosis (AS) does not benefit all patients. We performed a prospective multicenter study to investigate the cost-effectiveness of TAVR in a Japanese cohort. METHODS AND RESULTS: We prospectively enrolled 110 symptomatic patients with severe AS who underwent TAVR from five institutions. The quality of life measurement (QOL) was performed for each patient before and at 6 months after TAVR. Patients without an improvement in QOL at 6 months after TAVR were defined as non-responders. Pre-TAVR higher QOL, higher clinical frailty scale predicted the non-responders. Three models, 1) conservative treatment for all patients strategy, 2) TAVR for all patients strategy, and 3) TAVR for a selected patient strategy who is expected to be a responder, were simulated. Lifetime cost-effectiveness was estimated using incremental cost-effectiveness ratio (ICER) and cost per quality-adjusted life-year (QALY) gained. In comparison to conservative therapy for all patients, ICER was estimated to be 5,765,800 yen/QALY for TAVR for all patients and 2,342,175 yen/QALY for TAVR for selected patient strategy patients, which is less than the commonly accepted ICER threshold of 5,000,000 yen/QALY. CONCLUSIONS: TAVR for selected patient strategy model is more cost-effective than TAVR for all patient strategy without reducing QOL in the Japanese healthcare system. TAVR for selected patient strategy has potential benefit for optimizing the TAVR treatment in patients with high frailty and may direct our resources toward beneficial interventions.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Qualidade de Vida , Análise Custo-Benefício , Estudos Prospectivos , Fragilidade/etiologia , Estenose da Valva Aórtica/etiologia , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA