RESUMO
BACKGROUND/PURPOSE: This study evaluated compliance with a multi-institutional quality improvement management protocol for Type-C esophageal atresia with distal tracheoesophageal fistula (EA/TEF). METHODS: Compliance and outcomes before and after implementation of a perioperative protocol bundle for infants undergoing Type-C EA/TEF repair were compared across 11 children's hospitals from 1/2016-1/2019. Bundle components included elimination of prosthetic material between tracheal and esophageal suture lines during repair, not leaving a transanastomotic tube at the conclusion of repair (NO-TUBE), obtaining an esophagram by postoperative-day-5, and discontinuing prophylactic antibiotics 24â¯h postoperatively. RESULTS: One-hundred seventy patients were included, 40% pre-protocol and 60% post-protocol. Bundle compliance increased 2.5-fold pre- to post-protocol from 17.6% to 44.1% (pâ¯<â¯0.001). After stratifying by institutional compliance with all bundle components, 43.5% of patients were treated at low-compliance centers (<20%), 43% at medium-compliance centers (20-80%), and 13.5% at high-compliance centers (>80%). Rates of esophageal leak, anastomotic stricture, and time to full feeds did not differ between pre- and post-protocol cohorts, though there was an inverse correlation between NO-TUBE compliance and stricture rate over time (ρâ¯=â¯-0.75, pâ¯=â¯0.029). CONCLUSIONS: Compliance with our multi-institutional management protocol increased 2.5-fold over the study period without compromising safety or time to feeds and does not support the use of transanastomotic tubes. LEVEL OF EVIDENCE: Level II. TYPE OF STUDY: Treatment Study.