Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(3): 593-597, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36598431

RESUMO

INTRODUCTION: Pericardial bleeding is a rare but life-threatening complication of atrial fibrillation (AF) ablation. Patients taking uninterrupted oral anticoagulation (AC) may be at increased risk for refractory bleeding despite pericardiocentesis and administration of protamine. In such cases, andexanet alfa can be given to reverse rivaroxaban or apixaban. In this study, we aim to describe the rate of acute hemostasis and thromboembolic complications with andexanet for refractory pericardial bleeding during AF ablation. METHODS AND RESULTS: In this multicenter, case series, participating centers identified patients who received a dose of apixaban or rivaroxaban within 24 h of AF ablation, developed refractory pericardial bleeding during the procedure despite pericardiocentesis and administration of protamine and received andexanet. Eleven patients met inclusion criteria, with mean age of 73.5 ± 5.3 years and median CHA2 DS2 -VASc score 4 [3-5]. All patients received protamine and pericardiocentesis, and 9 (82%) received blood products. All patients received a bolus of andexanet followed, in all but one, by a 2-h infusion. Acute hemostasis was achieved in eight patients (73%) while three required emergent surgery. One patient (9%) experienced acute ST-elevation myocardial infarction after receiving andexanet. Therapeutic AC was restarted after a mean of 2.2 ± 1.9 days and oral AC was restarted after a mean of 2.9 ± 1.6 days, with no recurrent bleeding. CONCLUSION: In patients on uninterrupted apixaban or rivaroxaban, who develop refractory pericardial bleeding during AF ablation, andexanet can achieve hemostasis thereby avoiding the need for emergent surgery. However, there is a risk of thromboembolism following administration.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Tromboembolia , Humanos , Idoso , Fibrilação Atrial/cirurgia , Rivaroxabana/efeitos adversos , Inibidores do Fator Xa , Hemorragia/induzido quimicamente , Tromboembolia/etiologia , Protaminas , Ablação por Cateter/efeitos adversos , Anticoagulantes
2.
Circulation ; 144(20): 1590-1597, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34780252

RESUMO

BACKGROUND: Prescription opioids are a major contributor to the ongoing epidemic of persistent opioid use (POU). The incidence of POU among opioid-naïve patients after cardiac implantable electronic device (CIED) procedures is unknown. METHODS: This retrospective cohort study used data from a national administrative claims database from 2004 to 2018 of patients undergoing CIED procedures. Adult patients were included if they were opioid-naïve during the 180-day period before the procedure and did not undergo another procedure with anesthesia in the next 180 days. POU was defined by filling an additional opioid prescription >30 days after the CIED procedure. RESULTS: Of the 143 400 patients who met the inclusion criteria, 15 316 (11%) filled an opioid prescription within 14 days of surgery. Among these patients, POU occurred in 1901 (12.4%) patients 30 to 180 days after surgery. The likelihood of developing POU was increased for patients who had a history of drug abuse (odds ratio, 1.52; P=0.005), preoperative muscle relaxant (odds ratio, 1.52; P<0.001) or benzodiazepine (odds ratio, 1.23; P=0.001) use, or opioid use in the previous 5 years (OR, 1.76; P<0.0001). POU did not differ after subcutaneous implantable cardioverter defibrillator or other CIED procedures (11.1 versus 12.4%; P=0.5). In a sensitivity analysis excluding high-risk patients who were discharged to a facility or who had a history of drug abuse or previous opioid, benzodiazepine, or muscle relaxant use, 8.9% of the remaining cohort had POU. Patients prescribed >135 mg of oral morphine equivalents had a significantly increased risk of POU. CONCLUSIONS: POU is common after CIED procedures, and 12% of patients continued to use opioids >30 days after surgery. Higher initially prescribed oral morphine equivalent doses were associated with developing POU.


Assuntos
Analgésicos Opioides/uso terapêutico , Desfibriladores Implantáveis , Cuidados Pós-Operatórios , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/efeitos adversos , Tomada de Decisão Clínica , Bases de Dados Factuais , Gerenciamento Clínico , Prescrições de Medicamentos/normas , Prescrições de Medicamentos/estatística & dados numéricos , Duração da Terapia , Pesquisas sobre Atenção à Saúde , Humanos , Vigilância em Saúde Pública
3.
J Cardiovasc Electrophysiol ; 32(7): 1857-1864, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33993572

RESUMO

INTRODUCTION: Esophageal injury during atrial fibrillation (AF) ablation is a life-threatening complication. We sought to measure the association of esophageal temperature attenuation with radiofrequency (RF) electrode impedance, contact force, and distance from the esophagus. METHODS: The retrospective study cohort included 35 patients with mean age 64 ± 10 years, of whom 74.3% were male, and 40% had persistent AF. All patients had undergone preprocedural cardiac magnetic resonance (CMR) followed by AF ablation with luminal esophageal temperature monitoring. Lesion locations were co-registered with CMR image segmentations of left atrial and esophageal anatomy. Luminal esophageal temperature, time matched RF lesion data, and ablation distance from the nearest esophageal location were collected as panel data. RESULTS: Luminal esophageal temperature changes corresponding to 3667 distinct lesions, delivered with mean power 27.9 ± 5.5 W over a mean duration of 22.2 ± 10.5 s were analyzed. In multivariable analyses, clustered per patient, examining posterior wall lesions only, and adjusted for lesion power and duration as set by the operator, lesion distance from the esophagus (-0.003°C/mm, p < .001), and baseline impedance (-0.015°C/Ω, p < .001) were associated with changes in luminal esophageal temperature. CONCLUSION: Esophageal luminal temperature rises are associated with shorter lesion distance from esophagus and lower baseline impedance during RF lesion delivery. When procedural strategy requires RF delivery near the esophagus, selection of sites with higher baseline impedance may improve safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Eletrodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Temperatura
4.
J Cardiovasc Electrophysiol ; 32(1): 49-57, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33205513

RESUMO

INTRODUCTION: Data on the mechanisms of atrial arrhythmias (AAs) and outcomes of catheter ablation (CA) in lung transplantation (LT) patients are insufficient. We evaluated the electrophysiologic features and outcomes of CA of AAs in LT patients. METHODS AND RESULTS: We conducted a retrospective study of all the LT patients who underwent CA for AAs at our institution between 2004 and 2019. A total of 15 patients (43% males, age: 61 ± 10 years) with a history of LT (60% bilateral and 40% unilateral) were identified. All patients had documented organized AA on surface electrocardiogram and seven patients also had atrial fibrillation (AF; 47% with >1 clinical arrhythmia). At electrophysiological study, 19 organized AAs were documented (48% focal and 52% macro-re-entrant). Focal atrial tachycardias/flutters were targeted along the pulmonary vein (PV) anastomotic site at the left inferior PV (n = 2), ridge and carina of the left superior PV (n = 2), left atrium (LA) posterior wall (n = 3), LA roof (n = 1), and tricuspid annulus (n = 1). Macro-re-entrant AAs included cavotricuspid isthmus-dependent flutter (n = 2), incisional LA flutter (n = 4), LA roof-dependent flutter (n = 1), and mitral annular flutter (n = 3). In patients with LA mapping (n = 13), PV reconnection on the side of the LT was found in six patients (40%, all with clinically documented AF), with a mean of 2.1 ± 0.9 PVs reconnected per patient. Patients with AF underwent successful PV isolation. After a median follow-up of 19 months (range: 6-86 months), 75% of patients remained free from recurrent AAs. No procedural major complications occurred. CONCLUSION: In patients with prior LT, recurrent AAs are typically associated with substrate surrounding the surgical anastomotic lines and/or chronically reconnected PVs. CA of AAs in this population is safe and effective to achieve long-term arrhythmia control.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Transplante de Pulmão , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criança , Feminino , Humanos , Transplante de Pulmão/efeitos adversos , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 31(7): 1726-1739, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32298038

RESUMO

INTRODUCTION: In patients with nonischemic cardiomyopathy (NICM) little is known about the clinical impact of catheter ablation (CA) of septal ventricular tachycardia (VT) resulting in the collateral injury of the conduction system (CICS). METHODS AND RESULTS: Ninety-five consecutive patients with NICM underwent CA of septal VT. Outcomes in patients with no baseline conduction abnormalities who developed CICS (group 1, n = 28 [29%]) were compared to patients with no CICS (group 2, n = 17 [18%]) and to patients with preexisting conduction abnormalities or biventricular pacing (group 3, n = 50 [53%]). Group-1 patients were younger, had a higher left ventricular ejection fraction and a lower prevalence of New York Heart Association III/IV class compared to group 3 while no significant differences were observed with group 2. After a median follow-up of 15 months, VT recurred in 14% of patients in group 1, 12% in group 2 (P = .94) and 32% in group 3 (P = .08) while death/transplant occurred in 14% of patients in group 1, 18% in group 2 (P = .69) and 28% in group 3 (P = .15). A worsening of left ventricular ejection fraction (LVEF) (median LVEF variation, -5%) was observed in group 1 compared to group 2 (median LVEF variation, 0%; P < .01) but not group-3 patients (median LVEF variation, -4%; P = .08) with a consequent higher need for new biventricular pacing in group 1 (43%) compared to group 2 (12%; P = .03) and group 3 (16%; P < .01). CONCLUSIONS: In patients with NICM and septal substrate, sparing the abnormal substrate harboring the conduction system provides acceptable VT control while preventing a worsening of the systolic function.


Assuntos
Cardiomiopatias , Ablação por Cateter , Taquicardia Ventricular , Cardiomiopatias/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Humanos , Volume Sistólico , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
6.
J Cardiovasc Electrophysiol ; 31(2): 423-431, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31916273

RESUMO

BACKGROUND: We have previously demonstrated the feasibility of a nurse-led risk factor modification (RFM) program for improving weight loss and obstructive sleep apnea (OSA) care among patients with atrial fibrillation (AF). OBJECTIVE: We now report its impact on arrhythmia outcomes in a subgroup of patients undergoing catheter ablation. METHODS: Participating patients with obesity and/or need for OSA management (high risk per Berlin Questionnaire or untreated OSA) underwent in-person consultation and monthly telephone calls with the nurse for up to 1 year. Arrhythmias were assessed by office ECGs and ≥2 wearable monitors. Outcomes, defined as Arrhythmia control (0-6 self-terminating recurrences, with ≤1 cardioversion for nonparoxysmal AF) and Freedom from arrhythmias (no recurrences on or off antiarrhythmic drugs), were compared at 1 year between patients undergoing catheter ablation who enrolled and declined RFM. RESULTS: Between 1 November 2016 and 1 April 2018, 195 patients enrolled and 196 declined RFM (body mass index, 35.1 ± 6.7 vs 34.3 ± 6.3 kg/m2 ; 50% vs 50% paroxysmal AF; P = NS). At 1 year, enrolled patients demonstrated significant weight loss (4.7% ± 5.3% vs 0.3% ± 4.4% in declined patients; P < .0001) and improved OSA care (78% [n = 43] of patients diagnosed with OSA began treatment). However, outcomes were similar between enrolled and declined patients undergoing ablation (arrhythmia control in 80% [n = 48] vs 79% [n = 38]; freedom from arrhythmia in 58% [n = 35] vs 71% [n = 34]; P = NS). CONCLUSION: Despite improving weight loss and OSA care, our nurse-led RFM program did not impact 1-year arrhythmia outcomes in patients with AF undergoing catheter ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Papel do Profissional de Enfermagem , Obesidade/enfermagem , Comportamento de Redução do Risco , Apneia Obstrutiva do Sono/enfermagem , Idoso , Antiarrítmicos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Índice de Massa Corporal , Ablação por Cateter/efeitos adversos , Dieta Saudável/enfermagem , Exercício Físico , Feminino , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/diagnóstico , Obesidade/fisiopatologia , Educação de Pacientes como Assunto , Avaliação de Programas e Projetos de Saúde , Recidiva , Fatores de Risco , Sono , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Redução de Peso
7.
Pacing Clin Electrophysiol ; 42(3): 333-340, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30656717

RESUMO

BACKGROUND: Noninducibility of ventricular tachycardia (VT) at noninvasive programmed stimulation performed shortly following ablation (negative NIPS) predicts low risk of the medium-term recurrence. This study aimed to evaluate long-term rate and mode of recurrence following negative NIPS. METHODS: We extended follow-up on patients in whom no VT could be induced at NIPS following ablation between 2008 and 2010. Recurrent VTs were categorized as "Original clinical" if they matched VT that had occurred spontaneously prior to the index ablation; "Original nonclinical" if they matched VT that was induced during the index ablation but had not occurred spontaneously; or "New." Among those undergoing repeat ablation, the area ablated to treat the recurrent VT was categorized as "Targeted initial scar" if it was targeted during the index procedure; "Untargeted initial scar" if it was present but not targeted during the index procedure; or "New scar" if it was not present during the index procedure. RESULTS: Of 60 patients with negative NIPS, 18 (30%) had recurrent VT and nine underwent repeat ablation over (4.1 ± 3.2) years follow-up. Of 23 recurrent VTs, 18 (78%) were "New." During repeat ablations, six (46%) of the 13 recurrent VTs were ablated in "untargeted initial scar" and four (31%) in "new scar." CONCLUSIONS: When spontaneous or inducible VTs are eliminated with ablation and no longer inducible during NIPS, these VTs are unlikely to recur during long-term follow-up. More commonly, new VTs occur, which are either associated with areas of scar not present or not targeted during the initial ablation.


Assuntos
Ablação por Cateter/métodos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva
8.
J Cardiovasc Electrophysiol ; 29(11): 1530-1539, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30230120

RESUMO

INTRODUCTION: The characteristics of the epicardial (EPI) substrate responsible for ventricular tachycardia (VT) in ischemic cardiomyopathy (ICM) are undefined, and data on the long-term outcomes of EPI catheter ablation limited. We evaluated the prevalence, electrophysiologic features, and outcomes of catheter ablation of EPI VT in ICM. METHODS AND RESULTS: From December 2010 to June 2013, a total of 13 of 93 (14%) patients with ICM underwent catheter ablation at our institution and had conclusive evidence of critical EPI substrate demonstrated to participate in VT with activation, entrainment and/or pace mapping during sinus rhythm (two other patients underwent EPI mapping but had no optimal ablation targets). The electrophysiologic substrate characteristics and activation/entrainment mapping data were compared with a reference group of ICM patients without evidence of critical EPI substrate (N = 44), defined as a complete procedural success (noninducibility of any VT at programmed stimulation) after endocardial (ENDO)-only ablation. Patients with failed EPI access (N = 2) or history of cardiac surgery (N = 92) were excluded from the study. All 13 patients had evidence of abnormal EPI substrate with fractionated/late/split electrograms and low-bipolar voltage areas. The critical VT ablation sites were all located within the EPI bipolar "dense" scar (<1.0 mV) opposite the ENDO bipolar scar in 77% of cases and extending beyond the ENDO bipolar scar (within the ENDO unipolar low-voltage area) in the remaining patients. Compared with the reference ENDO-only group, patients with EPI VT had a smaller ENDO bipolar scar area, 54.0 (37.1-84) vs 86.7 (55.6-112) cm2 ; P = 0.0159, with a similar extent of ENDO unipolar low voltage. No other substrate characteristics or location differed between the two groups. After 35.2 ± 24.2 months of follow-up, VT-free survival was 73% in patients with EPI VT compared with 66% in the ENDO-only group (log-rank P = 0.56). CONCLUSIONS: The presence of the critical EPI substrate responsible for VT can be demonstrated in at least 14% of patients with ICM. The majority of EPI critical ablation sites are distributed opposite the ENDO bipolar scar area and catheter ablation is effective in achieving long-term arrhythmia control.


Assuntos
Cardiomiopatias/epidemiologia , Ablação por Cateter/tendências , Eletrocardiografia/tendências , Isquemia Miocárdica/epidemiologia , Taquicardia Ventricular/epidemiologia , Idoso , Cardiomiopatias/fisiopatologia , Cardiomiopatias/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/cirurgia , Prevalência , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 29(6): 823-832, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29513397

RESUMO

INTRODUCTION: Whether successful catheter ablation for atrial fibrillation (AF) reduces risk of cerebrovascular events (CVEs) remains controversial and whether oral anticoagulation therapy (OAT) can be safely discontinued in patients rendered free of AF recurrences remains unknown. We evaluated OAT use patterns and examined long-term rates of CVEs (stroke/TIA) and major bleeding episodes (MBEs) in patients with nonparoxysmal AF treated with catheter ablation. METHODS AND RESULTS: Four hundred patients with nonparoxysmal AF (200 persistent, 200 longstanding persistent; mean age 60.3 ± 9.7 years, 82% male) undergoing first AF ablation were followed for 3.6 ± 2.4 years. OAT discontinuation during follow-up was permitted in selected patients per physician discretion. At last follow-up, allowing for multiple ablations, 172 (43.0%) patients were free of AF recurrence. Two hundred and seven (51.8%) discontinued OAT at some point; 174 (43.5%) were off OAT at last follow-up. Patients without AF recurrence were more likely to remain off OAT (HR 0.23 [95% CI 0.17-0.33]). Patients with persistent (versus longstanding persistent) AF type prior to ablation (HR 0.6 [CI 0.44-0.83]) and those with CHA2 DS2 -VASc score <2 (HR 0.56 [0.39-0.80]) were less likely to continue OAT. Seven patients had CVEs (incidence: 0.49/100 patient years) and 14 experienced MBE during follow-up (incidence: 0.98/100 patient years). Older age (P  =  0.001) and coronary artery disease (P  =  0.028) were associated with CVE. CONCLUSION: Anticoagulation discontinuation in well selected, closely monitored patients following successful ablation of nonparoxysmal AF was associated with a low rate of clinical embolic CVEs. Prospective studies are required to confirm safety of OAT discontinuation after successful AF ablation.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Ablação por Cateter , Ataque Isquêmico Transitório/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Esquema de Medicação , Feminino , Hemorragia/induzido quimicamente , Humanos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/fisiopatologia , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/fisiopatologia , Fatores de Tempo
10.
J Cardiovasc Electrophysiol ; 26(9): 963-968, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26075504

RESUMO

BACKGROUND: Many patients (pts) with interatrial septal repair (ASR) and/or multiple prior transseptal puncture (MTSP) are being referred for atrial fibrillation (AF) ablation. We examine the feasibility of repeat TSP in these settings. METHODS: Records were reviewed from a single center from 2001 to 2012. Criteria for MTSP were >2 priorAF ablation procedures and criteria for ASR were prior surgical or percutaneous interatrial septal repair. Intracardiac echocardiography (ICE) was used for all procedures. Repeat transseptal puncture (TSP) outcomes were classified as (1) routine, (2) challenging (additional tools, sheaths, multiple attempts), (3) failed, or (4) complicated (adverse event possibly related to TSP). Five hundred pts selected at random over the same time period undergoing 1st AF ablation without history of prior cardiac surgery were used as control. RESULTS: Two hundred and fifty-one pts met the criteria (MTSP = 224; ASR = 27). TSP was routinely accomplished in the majority (212 pts [95%] in MTSP; 20 pts [74%] in ASR). In the MTSP group, the number of challenging/failed cases increased proportionately with number of prior AF ablation procedures. There were no complications in the ASR group and 2 (1%) in MTSP. This was not different from that in the control arm (n = 6 [1%]; P = ns). Pericardial effusion was the only complication seen in all groups. CONCLUSIONS: In the majority of pts with scarred and/or repaired IAS, repeat TSP can be routinely accomplished using ICE guidance without any other special tools. Although repeat TSP can be occasionally difficult in pts with MTSP and ASR, it can be accomplished in the majority without serious complications.

11.
J Cardiovasc Electrophysiol ; 26(9): 994-999, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25991070

RESUMO

INTRODUCTION: Outflow tract ventricular arrhythmias (OT VAs) are common and catheter ablation is an effective treatment option. We sought to investigate the relationship between age-related anatomic aortic root changes and QRS morphology during left ventricular outflow tract (LVOT) pace-mapping using cardiac magnetic resonance (CMR) imaging. METHODS AND RESULTS: Fifty-one patients undergoing CMR imaging were divided into 3 groups based on age (<40, 40-60, >60 years). We measured the angle of the aortic root, the aorta to ventricular septal angle, the distance between the right coronary cusp (RCC) and left coronary cusp (LCC), and the distance between the ascending and descending aorta. Additionally, we evaluated the QRS morphologies obtained during pace-mapping from the LVOT. In older patients, LCC was more superior to the RCC (P < 0.01). Age was positively correlated with the aortic root angle (r2 = 0.481, P < 0.01) as well as the distances between the ascending and descending aorta at a level below the arch (r2 = 0.569, P < 0.01). In older patients, LVOT pace-mapping (performed in 16 patients) demonstrated higher maximal R-wave amplitude, and was greater when pacing from the LCC versus the RCC in lead III (1.8 ± 0.7 vs. 1.0 ± 0.5 mV, P = 0.02). CONCLUSION: The anatomy of the aortic root changes with age, and age-related aortic root changes may affect the QRS morphology during pace-mapping. Understanding the potential anatomic changes that accompany aging is important to maximize the efficacy of catheter ablation of OT VAs.

12.
Heart Rhythm ; 21(2): 133-140, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37956774

RESUMO

BACKGROUND: In arrhythmogenic right ventricular cardiomyopathy (ARVC), risk of atrial arrhythmias (AAs) persists after ventricular tachycardia (VT) ablation. OBJECTIVE: The purpose of this study was to determine the type, prevalence, outcome, and risk correlates of AA in ARVC in patients undergoing VT ablation. METHODS: Prospectively collected procedural and clinical data on ARVC patients undergoing VT ablation were analyzed. Risk score for typical atrial flutter was determined from univariate logistic regression analysis. RESULTS: Of 119 consecutive patients with ARVC and VT ablation, 40 (34%) had AA: atrial fibrillation (AF) in 31, typical isthmus-dependent atrial flutter (AFL) in 27, and atrial tachycardia/atypical flutter (AT) in 10. Seventeen patients (43%) with AA experienced inappropriate defibrillator therapy, with 15 patients experiencing shocks. Ablation was performed for typical AFL in 21 (53%), AT in 5 (13%), and pulmonary vein isolation for AF in 4 (10%) patients and prevented AA in 78% and all AFL during additional mean follow-up of 65 months. Risk score for typical flutter included age >40 years (1 point), ≥moderate right ventricular dysfunction (2 points), ≥moderate tricuspid regurgitation (2 points), ≥moderate right atrial dilation (2 points), and right ventricular volume >250 cc (3points), with score >4 identifying 50% prevalence of typical flutter. CONCLUSION: AAs are common in patients with ARVC and VT, can result in inappropriate implantable cardioverter-defibrillator shocks, and typically are controlled with atrial ablation. A risk score can be used to identify patients at high risk for typical AFL who may be considered for isthmus ablation at the time of VT ablation.


Assuntos
Displasia Arritmogênica Ventricular Direita , Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Adulto , Flutter Atrial/complicações , Flutter Atrial/diagnóstico , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Supraventricular/cirurgia , Complicações Pós-Operatórias/etiologia , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
13.
J Interv Card Electrophysiol ; 67(3): 559-569, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37592198

RESUMO

BACKGROUND: The use of a multi-electrode Optrell mapping catheter during ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation procedures has not been widely reported. OBJECTIVES: We aim to describe the feasibility and safety of using the Optrell multipolar mapping catheter (MPMC) to guide catheter ablation of VT and PVCs. METHODS: We conducted a single-center, retrospective evaluation of patients who underwent VT or PVC ablation between June and November 2022 utilizing the MPMC. RESULTS: A total of 20 patients met the inclusion criteria (13 VT and 7 PVC ablations, 80% male, 61 ± 15 years). High-density mapping was performed in the VT procedures with median 2753 points [IQR 1471-17,024] collected in the endocardium and 12,830 points [IQR 2319-30,010] in the epicardium. Operators noted challenges in manipulation of the MPMC in trabeculated endocardial regions or near valve apparatus. Late potentials (LPs) were detected in 11 cases, 7 of which had evidence of isochronal crowding demonstrated during late annotation mapping. Two patients who also underwent entrainment mapping had critical circuitry confirmed in regions of isochronal crowding. In the PVC group, high-density voltage and activation mapping was performed with a median 1058 points [IQR 534-3582] collected in the endocardium. CONCLUSIONS: This novel MPMC can be used safely and effectively to create high-density maps in LV endocardium or epicardium. Limitations of the catheter include a longer wait time for matrix formation prior to starting point collection and challenges in manipulation in certain regions.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Masculino , Feminino , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Eletrodos , Catéteres , Ablação por Cateter/métodos
14.
Heart Rhythm ; 21(1): 18-24, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37827346

RESUMO

BACKGROUND: Cardiac stereotactic body radiotherapy (SBRT) has emerged as a promising noninvasive treatment for refractory ventricular tachycardia (VT). OBJECTIVE: The purpose of this study was to describe the safety and effectiveness of SBRT for VT in refractory to extensive ablation. METHODS: After maximal medical and ablation therapy, patients were enrolled in a prospective registry. Available electrophysiological and imaging data were integrated to generate a plan target volume. All SBRTs were planned with a single 25 Gy fraction using respiratory motion mitigation strategies. Clinical outcomes at 6 weeks, 6 months, and 12 months were analyzed and compared with the 6 months prior to treatment. VT burden (implantable cardioverter-defibrillator [ICD] shocks and antitachycardia pacing sequences) as well as clinical and safety outcomes were the main outcomes. RESULTS: Fifteen patients were enrolled and underwent planning. Fourteen (93%) underwent treatment, with 12 (80%) surviving to the end of the 6-week period and 10 (67%) surviving to 12 months. From 6 week to 12 months, there was recurrence of VT, which resulted in either appropriate antitachycardia pacing or ICD shocks in 33% (4 of 12). There were significant reductions in treated VT at 6 weeks to 6 months (98%) and at 12 months (99%) compared to the 6 months before treatment. There was a nonsignificant trend toward lower amiodarone dose at 12 months. Four deaths occurred after treatment, with no changes in ventricular function. CONCLUSION: For a select group of high-risk patients with VT refractory to standard therapy, SBRT is associated with a reduction in VT and appropriate ICD therapies over 1 year.


Assuntos
Amiodarona , Desfibriladores Implantáveis , Radiocirurgia , Taquicardia Ventricular , Humanos , Radiocirurgia/métodos , Resultado do Tratamento
15.
Heart Rhythm O2 ; 5(1): 34-40, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38312199

RESUMO

Background: Long-term rhythm monitoring to detect atrial fibrillation (AF) following a cryptogenic stroke (CS) is well established. However, the burden of organized atrial arrhythmias in this population is not well defined. Objective: The purpose of this study was to assess the incidence and risk factors for organized atrial arrhythmias in patients with CS. Methods: We evaluated all patients with CS who received an insertable cardiac monitor (ICM) between October 2014 and April 2020. All ICM transmissions categorized as AF, tachycardia, or bradycardia were reviewed. We evaluated the time to detection of organized AF and the combination of either organized atrial arrhythmia or AF. Results: A total of 195 CS patients with ICMs were included (51% men; mean age 66 ± 12 years; mean CHA2DS2-VASC score 4.6). Over mean follow-up of 18.9 ± 11.2 months, organized atrial arrhythmias lasting ≥30 seconds were detected in 45 patients (23%), of whom 62% did not have AF. Seventeen patients had both organized atrial arrhythmia and AF, and another 21 patients had AF only. Compared to those with normal left atrial size, patients with left atrial enlargement had a higher adjusted risk for development of atrial arrhythmias (mild left atrial enlargement: hazard ratio 1.99; 95% confidence interval 1.06-3.75; moderate/severe left atrial enlargement: hazard ratio 3.06; 95% confidence interval 1.58-5.92). Conclusion: Organized atrial arrhythmias lasting ≥30 seconds are detected in nearly one-fourth of CS patients. Two-thirds of these patients did not have AF. Further studies are required to evaluate the impact of organized atrial arrhythmias on recurrent stroke risk.

16.
J Interv Card Electrophysiol ; 66(7): 1723-1728, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36790576

RESUMO

BACKGROUND: The wearable cardioverter defibrillator (WCD) is an important tool in mitigating sudden cardiac death (SCD). The WCD provides patient alarms for detected arrhythmias or electrical noise/artifact. Some patients experience frequent alarms for artifact. We sought to evaluate the effects of a novel artificial intelligence algorithm to reduce alarms related to electrical noise or artifact (advanced arrhythmia discrimination algorithm, AArD). METHODS: A retrospective review of a large commercial database of prescribed WCD. Patients prescribed the WCD during the years 2017 (discrimination algorithm, DA group) or during 2019 (advanced arrhythmia discrimination algorithm, AArD) were analyzed. A total of 96,000 patients were sampled, 48,000 in the control group (using standard direct algorithm, DA) and compared to 48,000 in the intervention AArD (4000 per group per month) for 12 months. The AArD further discriminates ECG signals based on a machine-learning algorithm utilizing intensity and frequency beyond the standard DA. Outcomes regarding alarms, arrhythmias, and safety were analyzed. RESULTS: The AArD algorithm was associated with a significant decrease in frequency of alarms over the course of WCD use; 54% of patients in the AARD versus 27% of DA had 0 alarms (P < .001). In the entire cohort, there was a 56% relative reduction in alarms with the use of AArD. Appropriate arrhythmia treatment time was not significantly different between the groups (44 s DA vs 45 s AArD [p = ns]). CONCLUSIONS: A novel artificial intelligence algorithm reduces alarms without delaying appropriate therapy for VT/VF. These changes may improve compliance and quality of life in patients with a WCD.


Assuntos
Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Humanos , Inteligência Artificial , Qualidade de Vida , Cardioversão Elétrica , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Eletrocardiografia , Desfibriladores/efeitos adversos
17.
JACC Clin Electrophysiol ; 9(2): 161-169, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36858681

RESUMO

BACKGROUND: Neuromodulation is increasingly recognized as a therapeutic strategy for patients with refractory ventricular arrhythmias (VAs). Percutaneous stellate ganglion blockade (SGB), transcutaneous magnetic stimulation (TcMS), and surgical cardiac sympathetic denervation (CSD) have all been utilized in this setting. OBJECTIVES: This study sought to characterize contemporary use and outcomes of these neuromodulation techniques for patients with refractory VA. METHODS: This retrospective cohort study included all patients at the Hospital of the University of Pennsylvania with antiarrhythmic drug (AAD)-refractory VA from 2019 to 2021 who were treated with SGB, TcMS, or CSD. RESULTS: A total of 34 patients (age 61 ± 14 years, 15 polymorphic VAs [44%], refractory to 1.8 ± 0.8 AADs) met inclusion criteria. SGB was performed on 11 patients (32%), TcMS on 19 (56%), and CSD on 7 (21%). Neuromodulation was associated with a reduction in the number of episodes of sustained VAs from 7 [IQR: 4-12] episodes in the 24 hours before the initial neuromodulation strategy to 0 [IQR: 0-1] episodes in the subsequent 24 hours (P < 0.001). During 1.2 ± 1.1 years of follow-up, 21 (62%) experienced recurrent VAs, and among those patients, the median time to recurrence was 3 [IQR: 1-25] days. Outcomes were similar among patients with monomorphic and polymorphic VAs. Among patients who had an acute myocardial infarction within 30 days before neuromodulation, the burden of VAs decreased from 11 [IQR: 7-12] episodes to 0 episodes in the 24 hours after treatment. CONCLUSIONS: Autonomic neuromodulation with SGB, TcMS, or CSD in patients with AAD-refractory VAs is safe and results in substantial acute reduction of VA although recurrent arrhythmias are common, and not all patients experience a reduction in arrhythmia burden.


Assuntos
Arritmias Cardíacas , Bloqueio Nervoso Autônomo , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Coração , Antiarrítmicos
18.
J Interv Card Electrophysiol ; 66(6): 1455-1464, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36525168

RESUMO

BACKGROUND: Adverse structural and electrical remodeling underlie persistent atrial fibrillation (PersAF). Restoration of sinus rhythm (SR) prior to ablation in PersAF may improve the underlying substrate, thus improving arrhythmia outcomes. The aim of this study was to evaluate if the presence of SR at time of ablation is associated with improved long-term arrhythmia outcomes of a limited catheter ablation (CA) strategy in PersAF. METHODS: Patients with PersAF undergoing pulmonary vein isolation at our institution from 2014-2018 were included. We compared patients who presented for ablation in SR (by cardioversion and/or antiarrhythmic drugs [AADs]) to those who presented in AF. Primary outcome of interest was freedom from atrial arrhythmias (AAs) on or off AADs at 1 year after single ablation. Secondary outcomes included freedom from AAs on or off AADs overall, freedom from AAs off AADs at 1 year, and time to recurrent AF. RESULTS: Five hundred seventeen patients were included (322 presented in AF, 195 SR). The primary outcome was higher in those who presented for CA in SR as compared to AF (85.6% vs. 77.0%, p = 0.017). Freedom from AAs off AAD at 12 months was also higher in those presenting in SR (59.0% vs. 44.4%; p = 0.001) and time to recurrent AF was longer (p = 0.008). Presence of SR at CA was independently associated with the primary outcome at 12 months (OR 1.77; 95% CI 1.08-2.90) and overall (OR 1.89; 95% CI 1.26-2.82). CONCLUSIONS: Presence of SR at time of ablation is associated with improved long-term arrhythmia outcomes of limited CA in PersAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Fatores de Tempo , Ablação por Cateter/efeitos adversos , Recidiva
19.
JACC Clin Electrophysiol ; 9(12): 2523-2533, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37715743

RESUMO

BACKGROUND: Entrainment and pace mapping are used to identify critical components (CCs) of ventricular tachycardia (VT) circuits. In patients with dense myocardial scarring, VT circuits may elude capture at standard high pacing outputs (up to 10 mA at a 2-millisecond pulse width). OBJECTIVES: The purpose of this study was to assess the utility of very high-output pacing (V-HOP, 50 mA at 2 milliseconds) for identifying CCs of VT circuits after standard high pacing output failed to elicit capture in densely scarred myocardial tissue. METHODS: Our standard VT ablation approach included electroanatomic mapping for substrate characterization and entrainment and/or pace mapping to identify CCs of VT circuits. Patients that required V-HOP to capture sites of interest comprised the study cohort. Ablation endpoints were VT termination and noninducibility. RESULTS: Twenty-five patients (71 ± 10 years of age, all males) undergoing 26 VT ablations met the inclusion criteria. The mean left ventricular ejection fraction was 30% ± 14%, and 85% had ischemic cardiomyopathy. V-HOP was used to successfully entrain VT in 17 patients, yielding central isthmus sites in 10 and entrance/exit sites in 4. VT terminated with radiofrequency ablation at these sites in 15 patients. In 9 patients, V-HOP identified scar locations with a delayed exit. Acute procedural success was achieved in 24 patients without any adverse events. Over a follow-up period of 16 ± 21 months, 2 patients experienced VT recurrence requiring repeat ablation during which the same location was targeted successfully in 1 patient. CONCLUSIONS: In VT patients with a dense scar that is traditionally inexcitable, V-HOP can identify CCs of the re-entrant circuit and guide successful ablation.


Assuntos
Isquemia Miocárdica , Taquicardia Ventricular , Masculino , Humanos , Cicatriz , Volume Sistólico , Função Ventricular Esquerda , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
20.
JACC Clin Electrophysiol ; 9(11): 2275-2287, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37737775

RESUMO

BACKGROUND: Targeting nonpulmonary vein triggers (NPVTs) of atrial fibrillation (AF) after pulmonary vein isolation can be challenging. NPVTs are often single ectopic beats with a surface P-wave obscured by a QRS or T-wave. OBJECTIVES: The goal of this study was to construct an algorithm to regionalize the site of origin of NPVTs using only intracardiac bipolar electrograms from 2 linear decapolar catheters positioned in the posterolateral right atrium (along the crista terminalis with the distal bipole pair in the superior vena cava) and in the proximal coronary sinus (CS). METHODS: After pulmonary vein isolation in 42 patients with AF, pacing from 15 typical anatomic NPVT sites was conducted. For each pacing site, the electrogram activation sequence was analyzed from the CS catheter (simultaneous/chevron/inverse chevron/distal-proximal/proximal-distal) and activation time (ie, CSCTAT) between the earliest electrograms from the 2 decapolar catheters was measured referencing the earliest CS electrogram; a negative CSCTAT value indicates the crista terminalis catheter electrogram was earlier, and a positive CSCTAT value indicates the CS catheter electrogram was earlier. A regionalization algorithm with high predictive value was defined and tested in a validation cohort with AF NPVTs localized with electroanatomic mapping. RESULTS: In the study patient cohort (71% male; 43% with persistent AF, 52% with left atrial dilation), the algorithm grouped with high precision (positive predictive value 81%-99%, specificity 94%-100%, and sensitivity 30%-94%) the 15 distinct pacing sites into 9 clinically useful regions. Algorithm testing in a 98 patient validation cohort showed predictive accuracy of 91%. CONCLUSIONS: An algorithm defined by the activation sequence and timing of electrograms from 2 linear multipolar catheters provided accurate regionalization of AF NPVTs to guide focused detailed mapping.


Assuntos
Fibrilação Atrial , Veia Cava Superior , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Catéteres , Algoritmos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA