Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Pediatr Cardiol ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38727825

RESUMO

This study aimed to evaluate the current state of congenital interventional cardiology training worldwide, with a focus on case volumes, competency assessment, and the need for ongoing mentorship during early career stages. A survey was conducted among program directors (PDs) of congenital interventional training programs across the globe. The survey gathered data on training pathways, case volumes, types of procedures performed, trainee competency assessment, and the role of ongoing mentorship. Of the 79 PDs who completed the survey, it was observed that training pathways and case volumes varied significantly, particularly between the United States and other countries. Most PDs reported an annual laboratory case volume of >500 congenital cardiac cases, with most cases being interventional. While trainees demonstrated competency in simple procedures (diagnostic cases, simple ASD closure), complex interventions (such as patent ductus arteriosus closure in premature infants) require ongoing mentorship for graduates. PDs recommended a minimum case volume of 400 total cases for trainees, including 250 interventional cases. In addition to case volumes, assessing trainee competency was deemed important, with clinical reasoning, judgment, skillset, teamwork, and complication management being key areas of evaluation. The study highlights the variability in congenital interventional cardiology training and the need for ongoing mentorship during the early career years. External mentorship programs, facilitated by national and international societies, are proposed to provide critical support for early career interventionalists thus enhancing patient care for congenital heart disease. Ultimately, the findings of this survey may serve as a framework for future training standards and guidelines in this specialized field.

2.
Interv Cardiol Clin ; 13(3): 399-408, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839172

RESUMO

Hybrid interventions in congenital heart disease (CHD) embody the inherent collaboration between congenital interventional cardiology and cardiothoracic surgery. Hybrid approaches to complex and common lesions provide the opportunity to circumvent the limitations of patient size, vascular access, severity of illness, and anatomy that would otherwise be prohibitive to surgical and percutaneous techniques alone. This review describes several important hybrid approaches to interventions in CHD.


Assuntos
Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos
3.
Interv Cardiol Clin ; 13(3): 385-398, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839171

RESUMO

Congenital heart disease (CHD) is the most common congenital birth defect with an incidence of 1 in 100. Current survival to adulthood is expected in 9 out of 10 children with severe CHD as the diagnostic, interventional, and surgical success improves. The adult CHD (ACHD) population is increasingly diverse, reflecting the broad spectrum of CHD and evolution of surgical techniques to improve survival. Similarly, transcatheter interventions have seen exponential growth and creativity to reduce the need for repeat sternotomies. This article focuses on newer data and evolving techniques for transcatheter interventions specific to certain ACHD populations.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/cirurgia , Cateterismo Cardíaco/métodos , Adulto , Procedimentos Cirúrgicos Cardíacos/métodos
4.
JACC Cardiovasc Interv ; 17(2): 231-244, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38267137

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) has expanded and evolved since its initial commercial approval in the United States in 2010. OBJECTIVES: This study sought to characterize real-world practice, including patient selection, procedural outcomes, complications, and off-label usage. METHODS: Characteristics and outcomes for patients undergoing balloon-expandable TPVR were collected from the American College of Cardiology National Cardiovascular Data Registry IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry. RESULTS: Between April 2016 and March 2021, 4,513 TPVR procedures were performed in patients with a median age of 19 years, 57% with a Melody (Medtronic Inc) and 43% with a SAPIEN (Edwards Lifesciences) valve. Most implanting centers performed <10 cases annually. One-third of transcatheter pulmonary valve implants were into homograft conduits, one-third were into bioprosthetic valves (BPVs), 25% were in native or patched right ventricular outflow tracts (RVOTs), and 6% were into Contegra (Medtronic Inc) conduits. Over the course of the study period, SAPIEN valve use grew from ∼25% to 60%, in large part because of implants in patients with a native/patched RVOT. Acute success was achieved in 95% of patients (95.7% in homografts, 96.2% in BPVs, 94.2% in native RVOTs, and 95.4% in Contegra conduits). Major adverse events occurred in 2.4% of procedures, more commonly in patients with a homograft (2.9%) or native RVOT (3.4%) than a prior BPV (1.4%; P = 0.004). CONCLUSIONS: This study describes novel population data on the use and procedural outcomes of TPVR with balloon-expandable valves. Over time, there has been increasing use of TPVR to treat regurgitant native RVOT anatomy, with the SAPIEN valve more commonly used for this application.


Assuntos
Próteses Valvulares Cardíacas , Valva Pulmonar , Substituição da Valva Aórtica Transcateter , Adulto , Humanos , Criança , Adulto Jovem , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Sistema de Registros
5.
J Am Coll Cardiol ; 83(1): 63-81, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38171712

RESUMO

Recent years have witnessed exponential growth in cardiac imaging technologies, allowing better visualization of complex cardiac anatomy and improved assessment of physiology. These advances have become increasingly important as more complex surgical and catheter-based procedures are evolving to address the needs of a growing congenital heart disease population. This state-of-the-art review presents advances in echocardiography, cardiac magnetic resonance, cardiac computed tomography, invasive angiography, 3-dimensional modeling, and digital twin technology. The paper also highlights the integration of artificial intelligence with imaging technology. While some techniques are in their infancy and need further refinement, others have found their way into clinical workflow at well-resourced centers. Studies to evaluate the clinical value and cost-effectiveness of these techniques are needed. For techniques that enhance the value of care for congenital heart disease patients, resources will need to be allocated for education and training to promote widespread implementation.


Assuntos
Inteligência Artificial , Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ecocardiografia , Técnicas de Imagem Cardíaca/métodos , Imageamento por Ressonância Magnética/métodos
6.
Circ Cardiovasc Interv ; 17(7): e013729, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38666384

RESUMO

BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight (P=0.018), body surface area (P=0.013), and minimum-to-descending aortic diameter ratio (P<0.001) were associated with higher baseline aortic gradient. The residual gradient was inversely associated with implant and final dilation diameters (P<0.001). The combined incidence of aortic injury and stent-related complications was 14%. There were no reports of abnormal brain scans or stroke. Blood pressure cuff gradient, echocardiographic arch velocity, and hypertension rates improved within 1-year follow-up with increased antihypertensive medication use. Reintervention was reported in 60 (41%) patients at a median of 84 (22-148) months to first reintervention. On multivariable logistic regression, residual aortic gradient >10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells.


Assuntos
Angioplastia com Balão , Aorta Torácica , Desenho de Prótese , Stents , Humanos , Estudos Retrospectivos , Masculino , Feminino , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/fisiopatologia , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Adolescente , Adulto Jovem , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Criança , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/terapia , Doenças da Aorta/fisiopatologia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Arteriopatias Oclusivas/terapia , Constrição Patológica , Estados Unidos , Aortografia
7.
J Soc Cardiovasc Angiogr Interv ; 2(6Part A): 101119, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-39129900

RESUMO

Background: Safety events and technical success (TS) have been previously reported for aortic and pulmonary valvuloplasty, but a composite performance measure as a novel, patient-centered strategy has neither been developed nor been studied. This study aims to refine a procedural performance (PP) variable, a composite of TS and procedural safety, for isolated, standard-risk aortic and pulmonary valvuloplasty. Methods: A multicenter review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes registry. Data were collected for all cases of isolated balloon aortic and pulmonary valvuloplasty from 2014 through 2017. Patients were excluded if they were aged <1 month, were inpatient at the time of the procedure, or had significant comorbidities, such as Williams or Noonan syndrome. Criteria for TS were developed and categorized (optimal, satisfactory, and unsatisfactory) by expert consensus based on previous outcome research. Adverse events (AE) were categorized by severity (level 1-5) using established criteria. Level 4 and 5 severity AE were considered high-severity AE. Using criteria of TS and AE severity, PP was divided into 3 composite outcome classes. Factors correlating with class III (suboptimal) PP were analyzed. Results: There were 169 cases of aortic and 270 cases of pulmonary valvuloplasty in the cohorts. In the aortic valvuloplasty cohort, a suboptimal PP (class III) occurred in 14% of cases, mostly due to high-severity AE (7%). No significant correlation between patient or case characteristics and PP was demonstrated. In the pulmonary valvuloplasty cohort, class III PP occurred in 9% of cases, predominantly due to residual valve gradient, which correlated with lower weight (P = .02). Conclusions: We designed a composite variable of PP consisting of TS and safety as a comprehensive measure of outcome. Incorporating both TS and AE may better reflect patient outcome than each metric measured separately. PP indices may identify areas for further investigation and quality improvement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA