Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
NMR Biomed ; 36(10): e4958, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37094995

RESUMO

Chemical exchange saturation transfer (CEST) has been explored for differentiation between tumour and benign tissue in prostate cancer (PCa) patients. With ultrahigh field strengths such as 7-T, the increase of spectral resolution and sensitivity could allow for selective detection of amide proton transfer (APT) at 3.5 ppm and a group of compounds that resonate at 2 ppm (i.e., [poly]amines and/or creatine). The potential of 7-T multipool CEST analysis of the prostate and the detection of PCa was studied in patients with proven localised PCa who were scheduled to undergo robot-assisted radical prostatectomy (RARP). Twelve patients were prospectively included (mean age 68.0 years, mean serum prostate-specific antigen 7.8ng/mL). A total of 24 lesions larger than 2 mm were analysed. Used were 7-T T2-weighted (T2W) imaging and 48 spectral CEST points. Patients received 1.5-T/3-T prostate magnetic resonance imaging and galium-68-prostate-specific membrane antigen-positron emission tomography/computerised tomography to determine the location of the single-slice CEST. Based on the histopathological results after RARP, three regions of interest were drawn on the T2W images from a known malignant zone and benign zone in the central and peripheral zones. These areas were transposed to the CEST data, from which the APT and 2-ppm CEST were calculated. The statistical significance of the CEST between the central zone, the peripheral zone, and tumour was calculated using a Kruskal-Wallis test. The z-spectra showed that APT and even a distinct pool that resonated at 2 ppm were detectable. This study showed a difference trend in the APT levels, but no difference in the 2-ppm levels when tested between the central zone, the peripheral zone, and tumour (H(2) = 4.8, p = 0.093 and H(2) = 0.86, p = 0.651, respectively). Thus, to conclude, we could most likely detect APT and amines and/or creatine levels noninvasively in prostate using the CEST effect. At group level, CEST showed a higher level of APT in the peripheral versus the central zone; however, no differences of APT and 2-ppm levels were observed in tumours.


Assuntos
Creatina , Neoplasias da Próstata , Masculino , Humanos , Idoso , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Prótons , Amidas/química , Aminas
2.
NMR Biomed ; 33(3): e4235, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31879985

RESUMO

Deuterium metabolic imaging (DMI) is a novel MR-based method to spatially map metabolism of deuterated substrates such as [6,6'-2 H2 ]-glucose in vivo. Compared with traditional 13 C-MR-based metabolic studies, the MR sensitivity of DMI is high due to the larger 2 H magnetic moment and favorable T1 and T2 relaxation times. Here, the magnetic field dependence of DMI sensitivity and transmit efficiency is studied on phantoms and rat brain postmortem at 4, 9.4 and 11.7 T. The sensitivity and spectral resolution on human brain in vivo are investigated at 4 and 7 T before and after an oral dose of [6,6'-2 H2 ]-glucose. For small animal surface coils (Ø 30 mm), the experimentally measured sensitivity and transmit efficiency scale with the magnetic field to a power of +1.75 and -0.30, respectively. These are in excellent agreement with theoretical predictions made from the principle of reciprocity for a coil noise-dominant regime. For larger human surface coils (Ø 80 mm), the sensitivity scales as a +1.65 power. The spectral resolution increases linearly due to near-constant linewidths. With optimal multireceiver arrays the acquisition of DMI at a nominal 1 mL spatial resolution is feasible at 7 T.


Assuntos
Deutério/metabolismo , Campos Magnéticos , Imageamento por Ressonância Magnética , Animais , Encéfalo/diagnóstico por imagem , Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 , Humanos , Imagens de Fantasmas , Ratos , Razão Sinal-Ruído
3.
NMR Biomed ; 31(4): e3890, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29442388

RESUMO

The combination of functional MRI (fMRI) and MRS is a promising approach to relate BOLD imaging to neuronal metabolism, especially at high field strength. However, typical scan times for GABA edited spectroscopy are of the order of 6-30 min, which is long compared with functional changes observed with fMRI. The aim of this study is to reduce scan time and increase GABA sensitivity for edited spectroscopy in the human visual cortex, by enlarging the volume of activated tissue in the primary visual cortex. A dedicated setup at 7 T for combined fMRI and GABA MRS is developed. This setup consists of a half volume multi-transmit coil with a large screen for visual cortex activation, two high density receive arrays and an optimized single-voxel MEGA-sLASER sequence with macromolecular suppression for signal acquisition. The coil setup performance as well as the GABA measurement speed, SNR, and stability were evaluated. A 2.2-fold gain of the average SNR for GABA detection was obtained, as compared with a conventional 7 T setup. This was achieved by increasing the viewing angle of the participant with respect to the visual stimulus, thereby activating almost the entire primary visual cortex, allowing larger spectroscopy measurement volumes and resulting in an improved GABA SNR. Fewer than 16 signal averages, lasting 1 min 23 s in total, were needed for the GABA fit method to become stable, as demonstrated in three participants. The stability of the measurement setup was sufficient to detect GABA with an accuracy of 5%, as determined with a GABA phantom. In vivo, larger variations in GABA concentration are found: 14-25%. Overall, the results bring functional GABA detections at a temporal resolution closer to the physiological time scale of BOLD cortex activation.


Assuntos
Espectroscopia de Ressonância Magnética , Córtex Visual/metabolismo , Ácido gama-Aminobutírico/metabolismo , Creatina/metabolismo , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética/instrumentação , Imagens de Fantasmas , Razão Sinal-Ruído
4.
Magn Reson Med ; 72(6): 1516-21, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24357271

RESUMO

PURPOSE: Improved diagnostic sensitivity could be obtained in cancer detection and staging when individual compounds of the choline pool can be detected. Therefore, a novel coil design is proposed, providing the ability to acquire both (1) H and (31) P magnetic resonance spectroscopic imaging (MRSI) in patients with prostate cancer. METHODS: A two-element (1) H/(31) P endorectal coil was designed by adjusting a commercially available 3T endorectal coil. The two-element coil setup was interfaced as a transceiver to a whole body 7T MR scanner. Simulations and phantom measurements were performed to compare the efficiency of the coil. (1) H MRSI and (31) P MRSI were acquired in vivo in prostate cancer patients. RESULTS: The efficiency of the (1) H/(31) P coil is comparable to the dual channel (1) H coil previously published. Individually distinguishable phospholipid metabolites in the in vivo (31) P spectra were: phosphoethanolamine, phosphocholine, phosphate, glycerophosphoethanolamine, glycerophosphocholine, phosphocreatine, and adenosine triposphate. (1) H MRSI was performed within the same scan session, visualizing choline, polyamines, creatine, and citrate. CONCLUSION: (1) H MRSI and (31) P MRSI can be acquired in the human prostate at 7T within the same scan session using an endorectal coil matched and tuned for (1) H (quadrature) and (31) P (linear) without the need of cable traps and with negligible efficiency losses in the (1) H and (31) P channel.


Assuntos
Biomarcadores Tumorais/metabolismo , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Espectroscopia de Prótons por Ressonância Magnética/métodos , Transdutores , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Fósforo/farmacocinética , Compostos Radiofarmacêuticos , Reto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Magn Reson Med ; 68(4): 1018-25, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22213204

RESUMO

At high field (7 T) spectral editing of γ-aminobutyric acid with MEGA-point-resolved spectroscopy is inefficient due to the large chemical shift displacement error. In this article, a new pulse sequence is designed which has minimal chemical shift displacement error to perform an efficient spectral editing of the γ-aminobutyric acid 3.0 ppm resonance at 7 T. The sequence consists of the conventional MEGA editing pulses and a semi-localized by adiabatic selective refocusing sequence. Phantom and in vivo measurements demonstrated an efficient detection of γ-aminobutyric acid. Using ECG triggering, excellent in vivo performance of the MEGA-semi-localized by adiabatic selective refocusing (MEGA-sLASER) provided well-resolved γ-aminobutyric acid signals in 27 mL volumes in the human brain at an echo time of 74 ms within a relatively short acquisition time (5 min). Furthermore, the high efficiency of the MEGA-sLASER was demonstrated by acquiring small volumes (8 mL) at an echo time of 74 ms, as well as long echo time measurements (222 ms in 27 mL volume).


Assuntos
Algoritmos , Química Encefálica , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Imagem Molecular/métodos , Processamento de Sinais Assistido por Computador , Ácido gama-Aminobutírico/análise , Humanos , Prótons
6.
Phys Med Biol ; 67(13)2022 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-35545081

RESUMO

Immobilization masks are used to prevent patient movement during head and neck (H&N) radiotherapy. Motion restriction is beneficial both during treatment, as well as in the pre-treatment simulation phase, where magnetic resonance imaging (MRI) is often used for target definition. However, the shape and size of the immobilization masks hinder the use of regular, close-fitting MRI receive arrays. In this work, we developed a mask-compatible 8-channel H&N array that consists of a single-channel baseplate, on which the mask can be secured, and a flexible 7-channel anterior element that follows the shape of the mask. The latter uses high impedance coils to achieve its flexibility and radiolucency. A fully-functional prototype was manufactured, its radiolucency was characterized, and the gain in imaging performance with respect to current clinical setups was quantified. Dosimetry measurements showed an overall dose change of -0.3%. Small, local deviations were up to -2.7% but had no clinically significant impact on a full treatment plan, as gamma pass rates (3%/3 mm) only slightly reduced from 97.9% to 97.6% (clinical acceptance criterion: ≥95%). The proposed H&N array improved the imaging performance with respect to three clinical setups. The H&N array more than doubled (+123%) and tripled (+246%) the signal-to-noise ratio with respect to the clinical MRI-simulation and MR-linac setups, respectively.G-factors were also lower with the proposed H&N array. The improved imaging performance resulted in a clearly visible signal-to-noise ratio improvement of clinically used TSE and DWI acquisitions. In conclusion, the 8-channel H&N array improves the imaging performance of MRI-simulation and MR-linac acquisitions, while dosimetry suggests that no clinically significant dose changes are induced.


Assuntos
Aceleradores de Partículas , Radioterapia Guiada por Imagem , Cabeça , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA