1.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38554125

RESUMO

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Assuntos
Estenose da Valva Aórtica , Benchmarking , Tempo de Internação , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Masculino , Feminino , Idoso de 80 Anos ou mais , Tempo de Internação/estatística & dados numéricos , Idoso , Procedimentos Clínicos , Europa (Continente)/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Segurança do Paciente
2.
Europace ; 23(2): 254-263, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33083813

RESUMO

AIMS: We determined the incidence and type of arrhythmias at 2-year follow-up in patients with new-onset persistent left bundle branch block (LBBB) following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: Multicentre prospective study including 103 consecutive patients with new-onset persistent LBBB post-TAVR (SAPIEN XT/3: 53; CoreValve/Evolut R: 50). An implantable cardiac monitor (Reveal XT, Reveal Linq) was implanted before hospital discharge and patients had continuous monitoring for up to 2 years. Arrhythmic events were adjudicated in a central core lab. 1836 new arrhythmic events (tachyarrhythmias: 1655 and bradyarrhythmias: 181) occurred at 2 years. Of these, 283 (15%) occurred beyond 1 year (tachyarrhythmias 212, bradyarrhythmias 71) in 33 (36%) patients, without differences between valve type. Most late (>1 year) arrhythmic events were asymptomatic (94%) and led to a treatment change in 17 (19%) patients. A total of 71 late bradyarrhythmias [high-degree atrioventricular block (HAVB): 3, severe bradycardia: 68] were detected in 17 (21%) patients. At 2 years, 18 (17%) patients had received a permanent pacemaker (PPM) or implantable cardiac-defibrillator. PPM implantation due to HAVB predominated in the early phase post-TAVR, with only 1 HAVB event requiring PPM implantation after 1 year. CONCLUSION: Patients with new-onset LBBB post-TAVR exhibited a very high burden of arrhythmic events within the 2 years post-procedure. While new tachyarrhythmic events were homogeneously distributed over time, the vast majority of new HAVB episodes leading to PPM implantation occurred early after the procedure. These results should help to guide the management of this challenging group of patients. (clinicaltrials.gov: NCT02153307).


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Humanos , Estudos Prospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 44(7): 1216-1223, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34110038

RESUMO

BACKGROUND: Gastrointestinal bleeding (GIB) is associated with a high recurrence rate and a prior GIB episode is common in real-world left atrial appendage closure (LAAC) recipients. The present study sought to evaluate the clinical characteristics and outcomes of patients with prior GIB undergoing LAAC, and to determine the factors associated with and clinical impact of GIB recurrence. METHODS: Multicenter study including 277 consecutive patients who underwent percutaneous LAAC and had prior GIB. All-cause death, all bleeding, GIB recurrence, and clinical ischemic stroke were recorded. RESULTS: After a median follow-up of 17 (interquartile range: 6-37) months post-LAAC, the rates of death, bleeding, GIB recurrence, and ischemic stroke were 14.0 per 100 person-year (PY), 29.3 per 100 PY, 17.7 per 100 PY, and 1.1 per 100 PY, respectively. GIB recurrence occurred within 3 months post-LAAC in 55.8% of patients. A previous lower GIB (vs. upper or unclassified) (HR: 1.76; 95% CI: 1.09-2.82; p = .020) and eGFR < 45 mL/min (HR: 1.70; 95% CI:1.04-2.67; p = .033) determined an increased risk of GIB recurrence. By multivariable analysis, eGFR < 45 mL/min (HR: 2.72; 95% CI: 1.70-4.34; p < .001), GIB recurrence following LAAC (HR: 2.15; 95% CI: 1.33-3.46; p = .002), diabetes mellitus (HR: 1.77; 95% CI: 1.10-2.84; p = .018), and age (HR: 1.06; 95% CI: 1.03-1.10; p < .001) were associated with an increased mortality. CONCLUSIONS: Patients with prior GIB undergoing LAAC exhibited a relatively low rate of GIB recurrence, and prior lower GIB and moderate-to-severe chronic kidney disease determined an increased risk. GIB recurrence was associated with an increased mortality.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Hemorragia Gastrointestinal/complicações , Hemorragia Gastrointestinal/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Recidiva , Resultado do Tratamento
4.
Am Heart J ; 221: 19-28, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31896037

RESUMO

BACKGROUND: Although there have been several reports documenting complications related with transesophageal echocardiography (TEE) manipulation following cardiac surgery, there is a paucity of data regarding the safety of TEE used to guide catheter-based interventions. The aim of this study was to determine the prevalence, types and risk factors of complications associated with procedures requiring active TEE guidance. METHODS: This study included 1249 consecutive patients undergoing either transcatheter aortic valve implantation (TAVI), Mitraclip, left atrial appendage occlusion (LAAO) or paravalvular leak closure (PVLC). Patients were divided into 2 cohorts based on the degree of probe manipulation required to guide the procedure and the risk of developing a TEE-related complication: low-risk (TAVI, n = 1037) and high-risk (Mitraclip, LAAO and PVLC, n = 212). Patients were further analyzed according to the occurrence of major and minor TEE-related complications. RESULTS: The overall incidence of TEE-related complications was 0.9% in the TAVI group and 6.1% in the rest of the cohort (P < .001). Patients in the high-risk cohort had also a higher incidence of major-complications (2.8% vs 0.6%, P = .008), and factors associated with an increased risk were being underweight, having a prior history of gastrointestinal bleeding and the use of chronic steroids/immunosuppressive medications. Procedural time under TEE-manipulation was longer in patients exhibiting complications and was an independent predictor of major complications (OR = 1.13, 95% CI 1.01-1.25, for each 10 minutes increments in imaging time). Patients with major complications undergoing Mitraclip had the longest median time under TEE-manipulation (297 minutes) and a risk of developing a major-complication that was 10.64 times higher than the rest of the cohort (95% CI 3.30-34.29, P < .001). CONCLUSION: The prevalence of TEE-related complications associated with interventional procedures is higher than previously reported. Undergoing a prolonged procedure, particularly in the setting of Mitraclip, was the main factor linked to TEE-related complications.


Assuntos
Cateterismo Cardíaco/métodos , Transtornos de Deglutição/epidemiologia , Ecocardiografia Transesofagiana/efeitos adversos , Esôfago/lesões , Hemorragia Gastrointestinal/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/cirurgia , Transfusão de Sangue , Perfuração Esofágica/epidemiologia , Perfuração Esofágica/etiologia , Feminino , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Humanos , Lacerações/epidemiologia , Lacerações/etiologia , Masculino , Valva Mitral/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Cirurgia Assistida por Computador , Fatores de Tempo
5.
J Interv Cardiol ; 2019: 3579671, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772527

RESUMO

OBJECTIVES: To report on the feasibility and technical differences between coronary procedures performed before and after TAVR with the balloon-expandable Edwards-SAPIEN or the SAPIEN XT valves. BACKGROUND: Coronary artery disease (CAD) and aortic stenosis often coexist. Transcatheter aortic valve replacement (TAVR) is emerging as a treatment for younger and lower surgical risk patients who might not present with clinically evident CAD before TAVR. The demand for performing post-TAVR coronary angiograms (CAs) and percutaneous coronary interventions (PCIs) will thus increase, posing new technical challenges. METHODS: Over 1000 TAVRs were performed at the Quebec Heart and Lung Institute, of which 616 with the abovementioned valves. Of these, 28 patients had an analyzable pre- and post-TAVR CAs and 13 patients had pre- and post-TAVR PCIs performed. Procedural characteristics were gathered from all coronary procedures and subsequently compared amongst the same type of procedure performed at these two distinct time periods. RESULTS: Neither CAs-nor PCIs-performed after valve implantation revealed significant differences regarding arterial access site, catheter diameter, number of diagnostic or guiding catheters used, procedural duration, fluoroscopy time, or achievement of selective coronary injection. Lesion location and classification, as well as the preference of using a drug-eluting stent, remained unchanged. During post-TAVR CA, the amount of contrast delivered and the radiation dose area product were significantly lower compared with pre-TAVR CA values. CONCLUSIONS: Performance of CA and PCI after TAVR with a balloon-expandable valve appears unaffected by its presence.


Assuntos
Valvuloplastia com Balão , Angiografia Coronária , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Doses de Radiação
6.
Catheter Cardiovasc Interv ; 92(3): 583-591, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29745455

RESUMO

OBJECTIVES: To assess the clinical characteristics, management, and outcomes of patients diagnosed with infective endocarditis (IE) after edge-to-edge mitral valve repair with the MitraClip device. BACKGROUND: Transcatheter edge-to-edge mitral valve repair has emerged as an alternative to surgery in high-risk patients. However, few data exist on IE following transcatheter mitral procedures. METHODS: Four electronic databases (PubMed, Google Scholar, Embase, and Cochrane Library) were searched for original published studies on IE after edge-to-edge transcatheter mitral valve repair from 2003 to 2017. RESULTS: A total of 10 publications describing 12 patients with definitive IE (median age 76 years, 55% men) were found. The mean logistic EuroSCORE/EuroSCORE II were 41% and 45%, respectively. The IE episode occurred early (within 12 months post-procedure) in nine patients (75%; within the first month in five patients). Staphylococcus aureus was the most frequent (60%) causal microorganism, and severe mitral regurgitation was present in all cases but one. Surgical mitral valve replacement (SMVR) was performed in most (67%) patients, and the mortality associated with the IE episode was high (42%). CONCLUSIONS: IE following transcatheter edge-to-edge mitral valve repair is a rare but life-threatening complication, usually necessitating SMVR despite the high-risk profile of the patients. These results highlight the importance of adequate preventive measures and a prompt diagnosis and treatment of this serious complication.


Assuntos
Endocardite Bacteriana/microbiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Valva Mitral/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/fisiopatologia , Endocardite Bacteriana/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/microbiologia , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/microbiologia , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/fisiopatologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Expert Rev Med Devices ; 21(3): 187-196, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38155555

RESUMO

INTRODUCTION: Over the last two decades, mitral transcatheter edge-to-edge repair (M-TEER) has become a safe and effective therapy for severe mitral regurgitation in patients deemed at high surgical risk. AREAS COVERED: This review aims to encompass the most relevant and updated evidence in the field of M-TEER from its inception, focusing on clinical and anatomical features for proper patient and device selection. EXPERT OPINION: Growing operator experience and device iterations have resulted in improved clinical outcomes and an expansion of the therapy to patients with complex anatomies and clinical scenarios. Future investigations are warranted to determine the best management options and the most suitable device for every patient with MR.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Seleção de Pacientes , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
9.
Artigo em Inglês | MEDLINE | ID: mdl-38848005

RESUMO

Many lesions in patients undergoing percutaneous coronary intervention (PCI) exhibit significant calcification. Several techniques have been developed to improve outcomes in this setting. However, their impact on coronary microcirculation remains unknown. The aim of this study is to evaluate the influence of plaque modification techniques on coronary microcirculation across patients with severely calcified coronary artery disease. In this multicenter retrospective study, consecutive patients undergoing PCI with either Rotablation (RA) or Shockwave-intravascular-lithotripsy (IVL) were included. Primary endpoint was the impairment of coronary microvascular resistances assessed by Δ angiography-derived index of microvascular resistance (ΔIMRangio) which was defined as the difference in IMRangio value post- and pre-PCI. Secondary endpoints included the development of peri procedural PCI complications (flow-limiting coronary dissection, slow-flow/no reflow during PCI, coronary perforation, branch occlusion, failed PCI, stroke and shock developed during PCI) and 12-month follow-up adverse events. 162 patients were included in the analysis. Almost 80% of patients were male and the left descending anterior artery was the most common treated vessel. Both RA and IVL led to an increase in ΔIMRangio (22.3 and 10.3; p = 0.038, respectively). A significantly higher rate of PCI complications was observed in patients with ΔIMRangio above the median of the cohort (21.0% vs. 6.2%; p = 0.006). PCI with RA was independently associated with higher ΔIMRangio values (OR 2.01, 95% CI: 1.01-4.03; p = 0.048). Plaque modification with IVL and RA during PCI increases microvascular resistance. Evaluating the microcirculatory status in this setting might help to predict clinical and procedural outcomes and to optimize clinical results.

10.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38763211

RESUMO

INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup pre-transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length >60mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiac death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.31; 95%CI, 1.01-1.71; P=.042). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.

11.
Card Electrophysiol Clin ; 15(2): 193-200, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37076231

RESUMO

Left atrial appendage closure aims to eliminate the stasis component of Virchow triad by eliminating a cul-de-sac that favors thrombosis, particularly when atrial contractility becomes inefficient, such as in atrial fibrillation. Left atrial appendage closure devices have a common objective of sealing the appendage completely, with device stability and avoidance of device thrombosis. Two main device designs have been used to perform left atrial appendage closure: those that use a pacifier design (lobe + disk) and those that use a plug (single lobe) design. This review highlights the potential features and benefits of the single-lobe devices.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Humanos , Seguimentos , Resultado do Tratamento , Ecocardiografia Transesofagiana , Fibrilação Atrial/cirurgia , Trombose/prevenção & controle , Cateterismo Cardíaco
12.
Expert Rev Cardiovasc Ther ; 21(10): 703-712, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37815845

RESUMO

INTRODUCTION: With the expanding indications of transcatheter aortic valve replacement (TAVR) to younger and low-risk patients, the life expectancy of patients currently undergoing TAVR will likely outlive the durability of transcatheter bioprosthesis. Consequently, the number of failed transcatheter bioprosthesis requiring surgical valve explant or redo TAVR is expected to increase. AREAS COVERED: The aim of this review is to provide an updated overview of redo TAVR for treating degenerated transcatheter bioprosthesis, focusing on pre-procedural planning, potential challenges of coronary reaccess during TAVR-in-TAVR and main outcomes of TAVR explant and redo TAVR. EXPERT OPINION: Patient-tailored device selection and individualized implantation height should be carefully assessed during the index TAVR procedure (weighting between pacemaker avoidance and the potential risk of coronary occlusion in future TAVR-in-TAVR). Future prospective studies comparing safety and clinical outcomes between redo TAVR vs TAVR explant are eagerly awaited.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
13.
Int J Gen Med ; 16: 4257-4265, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37750105

RESUMO

Background: The percutaneous treatment of heart valve diseases carried out in the hemodynamic service is constantly growing. After analyzing the mortality, readmissions, success of the procedure, and complications, several studies support this type of percutaneous procedure. The increase in these procedures has required the creation of multidisciplinary teams and new diagnostic and care circuits, such as presurgical consultations and postsurgical follow-ups. Even so, there is little evidence regarding the effect of these consultations on quality indicators. Purpose: The objective of this study is to evaluate the impact of a program of presurgical and postsurgical nurse interventions (PROCESS-VALVE) on quality indicators of the health of patients undergoing percutaneous valve procedures. Patients and Methods: The influence of presurgical and postsurgical consultations on quality indicators will be evaluated through an ambispective quasi-experimental study. Patients will be recruited at a tertiary-level hospital in Barcelona, Spain. For the control group, data will be collected retrospectively from patients who underwent percutaneous valve procedures but did not receive pre- or postsurgical consultations. The intervention group comprises those patients agreeing to participate in the study and the hemodynamic nurse valve consultation program (PROCESS-VALVE). In addition, we will assess whether a face-to-face postsurgical consultation equally improves quality indicators compared to postsurgical telephone consultation; for this, a sub-study will be carried out comparing face-to-face or telephone postsurgical follow-up by means of a randomized controlled clinical trial with simple blinding in the intervention group. Discussion: This study will generate scientific evidence regarding the impact on quality indicators of a nursing intervention via presurgical and postsurgical consultations. In addition, it will allow us to decide the most appropriate follow-up strategy for this type of patient. Trial Registration: ClinicalTrials.gov NCT05179278, registration date 01/05/2022.

14.
Rev Esp Cardiol (Engl Ed) ; 76(10): 767-773, 2023 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36804557

RESUMO

INTRODUCTION AND OBJECTIVES: The cusp overlap technique (COT) has been proposed to reduce conduction disturbances (CD) after transcatheter aortic valve implantation (TAVI) with self-expanding supra-annular devices, but there are scarce data on COT with intra-annular valves. The aim of this study was to determine whether the use of the COT during Portico implantation results in higher valve implantation and lower rates of CD. METHODS: We included 85 patients undergoing TAVI with the Portico FlexNav system: 43 retrospective patients using the standard 3-cusp view and 42 prospective patients with the COT. Primary endpoints were implantation depth and new-onset CD (composite outcome of new-onset left bundle branch block and new permanent pacemaker implantation). RESULTS: COT resulted in a higher implantation depth (noncoronary cusp: 4.9±3.9 vs 7.4±3.0; P=.005) and lower new-onset CD (31.0% vs 58.1%; P=.012), with a tendency toward a lower need for permanent pacemaker implantation (14.3% vs 30.2%, P=.078; 7.7% vs 31.0%; P=.011 in patients without pre-existing right bundle branch block). Transvalvular aortic gradients were slightly lower with COT (8.7±3.7 vs 11.0±6.1; P=.044). There were no differences in technical success or major procedure-related complications. On multivariate analysis, COT use was associated with a lower risk of new-onset CD. CONCLUSIONS: Use of the COT during Portico implantation is feasible and facilitates a higher valve implant, which in turn may help to reduce rates of new-onset CD.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
15.
J Clin Med ; 12(18)2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37762965

RESUMO

Transcatheter aortic valve replacement (TAVR) is currently the treatment of choice for patients aged ≥75 years with severe aortic stenosis. Preoperative anemia is present in a large proportion of patients and may increase the risk of post-procedural complications. The purpose of this prognostic systematic review was to analyze the impact of baseline anemia on short- and mid-term outcomes following TAVR. A computerized search was performed on PubMed and Web of Science databases for studies published between January 2013 and December 2022. Primary outcomes were 30-day need for transfusion, acute renal failure, 30-day and mid-term mortality, and readmission during the first year post-TAVR. Data were analyzed via random effects model using inverse variance method with 95% confidence intervals. Eleven observational studies met our eligibility criteria and included a total of 12,588 patients. The prevalence of baseline anemia ranged between 39% and 72%, with no relevant sex differences. Patients with preprocedural anemia received more blood transfusions [OR: 2.95 (2.13-4.09)]), and exhibited increased rates of acute kidney injury [OR:1.74 (1.45-2.10)], short-term mortality [OR: 1.47 (1.07-2.01], and mid-term [OR: 1.89 (1.58-2.25)] mortality following TAVR compared with those without anemia. Baseline anemia determined an increased risk for blood transfusion, acute kidney injury, and short/mid-term mortality among TAVR recipients.

16.
Rev Esp Cardiol (Engl Ed) ; 76(1): 25-31, 2023 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35691867

RESUMO

INTRODUCTION AND OBJECTIVES: The PASCAL system is a novel device for transcatheter mitral valve repair based on the edge-to-edge concept. The unique features of this device might have a relevant impact on the repair outcomes. There are few data on clinical outcomes in real-life registries. The aim of this study was to report the early Iberian experience (Spain and Portugal) of the PASCAL system. METHODS: Procedural and 30-day outcomes were investigated in consecutive patients with symptomatic severe mitral regurgitation (MR) treated with the PASCAL system at 10 centers. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE) at 30 days. RESULTS: We included 68 patients (age, 75 [68-81] years; 38% women; EuroSCORE II 4.5%). MR etiology was degenerative in 25%, functional in 65%, and mixed in 10%. A total of 71% of patients were in New York Heart Association (NYHA) functional class≥III. Technical success was achieved in 96% and independent capture was used in 73% of procedures. In the treated population, MR at discharge was≤2+ in 100%, with no in-hospital deaths. At 30 days, the MAE rate was 5.9%, the all-cause mortality rate was 1.6%, 98% were in NYHA functional class≤II, and 95% had MR≤2+ (P<.001). CONCLUSIONS: Transcatheter mitral valve repair with the PASCAL system was safe and effective, with high procedural success and low rates of MAE. At 30 days, MR was significantly reduced, with a significant improvement in functional status.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento
17.
JACC Cardiovasc Interv ; 16(17): 2153-2164, 2023 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-37704301

RESUMO

BACKGROUND: In patients undergoing percutaneous coronary intervention (PCI) in the work-up pre-transcatheter aortic valve replacement (TAVR), the incidence and clinical impact of late bleeding events (LBEs) remain largely unknown. OBJECTIVES: This study sought to determine the incidence, clinical characteristics, associated factors, and outcomes of LBEs in patients undergoing PCI in the work-up pre-TAVR. METHODS: This was a multicenter study including 1,457 consecutive patients (mean age 81 ± 7 years; 41.5% women) who underwent TAVR and survived beyond 30 days. LBEs (>30 days post-TAVR) were defined according to the Valve Academic Research Consortium-2 criteria. RESULTS: LBEs occurred in 116 (7.9%) patients after a median follow-up of 23 (IQR: 12-40) months. Late bleeding was minor, major, and life-threatening or disabling in 21 (18.1%), 63 (54.3%), and 32 (27.6%) patients, respectively. Periprocedural (<30 days post-TAVR) major bleeding and the combination of antiplatelet and anticoagulation therapy at discharge were independent factors associated with LBEs (P ≤ 0.02 for all). LBEs conveyed an increased mortality risk at 4-year follow-up compared with no bleeding (43.9% vs 36.0; P = 0.034). Also, LBE was identified as an independent predictor of all-cause mortality after TAVR (HR: 1.39; 95% CI: 1.05-1.83; P = 0.020). CONCLUSIONS: In TAVR candidates with concomitant significant coronary artery disease requiring percutaneous treatment, LBEs after TAVR were frequent and associated with increased mortality. Combining antiplatelet and anticoagulation regimens and the occurrence of periprocedural bleeding determined an increased risk of LBEs. Preventive strategies should be pursued for preventing late bleeding after TAVR, and further studies are needed to provide more solid evidence on the most safe and effective antithrombotic regimen post-TAVR in this challenging group of patients.


Assuntos
Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Catéteres
18.
JACC Cardiovasc Interv ; 16(10): 1208-1217, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37225292

RESUMO

BACKGROUND: Coronary obstruction (CO) following transcatheter aortic valve replacement (TAVR) is a life-threatening complication, scarcely studied. OBJECTIVES: The authors analyzed the incidence of CO after TAVR, presentation, management, and in-hospital and 1-year clinical outcomes in a large series of patients undergoing TAVR. METHODS: Patients from the Spanish TAVI (Transcatheter Aortic Valve Implantation) registry who presented with CO in the procedure, during hospitalization or at follow-up were included. Computed tomography (CT) risk factors were assessed. In-hospital, 30-day, and 1-year all-cause mortality rates were analyzed and compared with patients without CO using logistic regression models in the overall cohort and in a propensity score-matched cohort. RESULTS: Of 13,675 patients undergoing TAVR, 115 (0.80%) presented with a CO, mainly during the procedure (83.5%). The incidence of CO was stable throughout the study period (2009-2021), with a median annual rate of 0.8% (range 0.3%-1.3%). Preimplantation CT scans were available in 105 patients (91.3%). A combination of at least 2 CT-based risk factors was less frequent in native than in valve-in-valve patients (31.7% vs 78.3%; P < 0.01). Percutaneous coronary intervention was the treatment of choice in 100 patients (86.9%), with a technical success of 78.0%. In-hospital, 30-day, and 1-year mortality rates were higher in CO patients than in those without CO (37.4% vs 4.1%, 38.3% vs 4.3%, and 39.1% vs 9.1%, respectively; P < 0.001). CONCLUSIONS: In this large, nationwide TAVR registry, CO was a rare, but often fatal, complication that did not decrease over time. The lack of identifiable predisposing factors in a subset of patients and the frequently challenging treatment when established may partly explain these findings.


Assuntos
Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Catéteres , Sistema de Registros
19.
Circ Cardiovasc Interv ; 16(3): e012554, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36943930

RESUMO

BACKGROUND: The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. METHODS: This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm2. A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. RESULTS: From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39-3.65; P=0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11-3.09]; P=0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41-1.45]; P=0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) and similar between groups. CONCLUSIONS: In patient with BAM, selecting a larger SAPIEN 3/Ultra THV increased the risk of conduction disturbances without any benefit on valve hemodynamics and clinical outcomes.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese
20.
JACC Cardiovasc Interv ; 16(18): 2277-2290, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37758382

RESUMO

BACKGROUND: The burden of cardiac death after transcatheter aortic valve replacement (TAVR), particularly from advanced heart failure (HF) and sudden cardiac death (SCD), remains largely unknown. OBJECTIVES: This study sought to evaluate the incidence and predictors of SCD and HF-related death in TAVR recipients treated with newer-generation devices. METHODS: This study included a total of 5,421 consecutive patients who underwent TAVR with newer-generation devices using balloon (75.7%) or self-expandable (24.3%) valves. RESULTS: After a median follow-up of 2 (IQR: 1-3) years, 976 (18.0%) patients had died, 50.8% from cardiovascular causes. Advanced HF and SCD accounted for 11.6% and 7.5% of deaths, respectively. Independent predictors of HF-related death were atrial fibrillation (HR: 2.17; 95% CI: 1.47-3.22; P < 0.001), prior pacemaker (HR: 1.79; 95% CI: 1.10-2.92; P = 0.01), reduced left ventricular ejection fraction (HR: 1.08 per 5% decrease; 95% CI: 1.01-1.14; P = 0.02), transthoracic approach (HR: 2.50; 95% CI: 1.37-4.55; P = 0.003), and new-onset persistent left bundle branch block (HR: 1.85; 95% CI: 1.14-3.02; P = 0.01). Two baseline characteristics (diabetes, HR: 1.81; 95% CI: 1.13-2.89; P = 0.01; and chronic kidney disease, HR: 1.72; 95% CI: 1.02-2.90; P = 0.04) and 3 procedural findings (valve in valve, HR: 2.17; 95% CI: 1.01-4.64; P = 0.04; transarterial nontransfemoral approach, HR: 2.23; 95% CI: 1.23-4.48; P = 0.01; and periprocedural ventricular arrhythmia, HR: 7.19; 95% CI: 2.61-19.76; P < 0.001) were associated with an increased risk of SCD after TAVR. CONCLUSIONS: Advanced HF and SCD accounted for a fifth of deaths after TAVR in contemporary practice. Potentially treatable factors leading to increased risk of HF deaths and SCD were identified, such as arrhythmia/dyssynchrony factors for HF and valve-in-valve TAVR or periprocedural ventricular arrhythmias for SCD.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Função Ventricular Esquerda , Resultado do Tratamento , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA