1.
Artigo em Inglês | MEDLINE | ID: mdl-38719632

RESUMO

BACKGROUND: The ACURATE neo2 transcatheter aortic valve was developed to improve paravalvular leak (PVL) rates while maintaining low rates of conduction disturbances and permanent pacemaker implantation (PPMI) seen with its predecessor. We aimed to compare conduction disturbances rates of transcatheter aortic valve replacement (TAVR) using ACURATE Neo2 with other commonly used valves. METHODS: A retrospective analysis of the Israeli TAVR registry between the years 2014-2023 was performed to compare conduction disturbances and PVL rates, and procedural outcomes, among patients treated with ACURATE neo2, Edwards Sapien 3 (S3), and Evolut PRO valves. Propensity score matching was performed to compare groups with similar characteristics. RESULTS: Following exclusion of patients with non-femoral access, unknown valve type, older-generation valves, and less commonly used valves or (n = 4387), our analysis included 3208 patients undergoing TAVR using ACURATE neo2, Edwards S3, and Evolut PRO valves. Propensity matched groups comprised 169 patients each. Rates of any conduction disturbances [left bundle branch block (LBBB), atrioventricular block, or PPMI] were lower in the ACURATE neo2 group compared to both other valves [15.8 %, S3-37.5 % (p < 0.001), Evolut PRO-27.5 % (p = 0.02)] as were LBBB rates [9.0 %, S3-31.3 % (p < 0.001); Evolut PRO-20.1 % (p = 0.01). Atrioventricular block and PPMI rates were lower without statistical significance, as were rates of above-moderate PVL. CONCLUSIONS: In this analysis, TAVR using ACURATE neo2 was associated with a lower composite rate of conduction disturbances in comparison to the Evolut PRO and Edwards S3 valves, mainly due to lower left bundle branch block rates, with non-significantly lower rates of PPMI and PVL.

2.
J Invasive Cardiol ; 34(4): E326-E333, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35366227

RESUMO

BACKGROUND: The Medtronic Evolut Pro valve (EPV) is a new-generation self-expanding valve (SEV), particularly designed to reduce paravalvular leak (PVL) rates in transcatheter aortic valve replacement (TAVR). We aimed to compare the safety and efficacy of EPV with older-generation SEVs, in particular, postprocedural PVL and permanent pacemaker (PPM) implantation rates. METHODS: We performed a retrospective, multicenter, propensity-matched analysis of the Israeli TAVR registry between September 2008 and June 2019. Two independent propensity score-matched comparisons were performed comparing EPV with the first-generation CoreValve (CV), and comparing EPV with the second-generation Evolut R valve (ERV). RESULTS: The registry included 2591 patients who were propensity-matched into 3 cohorts: EPV (n = 222), CV (n = 212), and ERV (n = 213). Moderate and above PVL rates were lower for EPV (angiographic PVL [aPVL], 0.6%; echocardiographic PVL [ePVL], 3.0%) as compared with CV (aPVL, 7.8% [P<.001] and ePVL, 11.6% [P<.01]), but not as compared with ERV (aPVL, 6.4% [P<.01] and ePVL, 4.4% [P=.57]). Lower rates of PPM were noted for EPV (16.3%) as compared with both CV (33.5%; P<.001) and ERV (24.4%; hazard ratio, 0.61; 95% confidence interval, 0.37-0.995; P=.046). Other safety and efficacy outcome rates were excellent, with significant improvements as compared with older-generation SEVs. CONCLUSIONS: The EPV demonstrates excellent procedural safety and efficacy outcomes. Moderate and above PVL rates were significantly reduced in comparison with CV; however, not significantly reduced as compared with ERV. The need for PPM implantation was lower as compared with both older-generation valves.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA