Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 25(1): 170, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38395809

RESUMO

BACKGROUND: Local infiltration analgesia (LIA) is frequently administered to patient undergoing joint replacement surgical procedures. The aim of the present research was to verify the safety of collected shed blood to be reinfused postoperatively, by measuring levobupivacaine levels in drainage blood in patients undergoing LIA during knee replacement surgery. PATIENTS AND METHODS: 24 patients who underwent total knee arthroplasty (TKA) and 12 scheduled for total hip arthroplasty (THA) who received intraoperative LIA were considered. Blood samples were collected from shed blood which was present in drainage 2 and 5 hours after surgery and serum was analysed by liquid chromatography-tandem mass spectrometry. RESULTS: At 2 hours postoperatively, the median levobupivacaine serum concentration in the collected shed blood was 1.2 mg/L (SD: 4.2) for TKA and 17.13 mg/L (SD: 24.4) for THA. At 5 hours, levobupivacaine concentration was 1.84 mg/L (SD: 2.2) for TKA and 17.5 mg/L (SD: 25.2) for THA. Higher values of average serum levobupivacaine concentration were reported in drains collected from patients who had undergone THA compared to TKA (p<0.001). BMI significantly influenced levels of serum drug, that resulted to be higher in patients with BMI<25 (p= 0.01). CONCLUSION: Levobupivacaine from collected shed blood that would have been returned to the patient, was below toxicity level at 2 and 5 hours after LIA during total joint replacement. The average serum levobupivacaine concentration was found to be higher in drains taken from THA patients than TKA patients. Patients with lower BMI demonstrated the highest levels of levobupivacaine in shed blood and a lower blood volume needed for central nervous system toxicity. Therefore, in patients with a lower BMI undergoing THA, anaesthetic dosage should be reduced or autotransfusion should be avoided to prevent potential risks of toxicity.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Drenagem , Humanos , Analgesia/métodos , Anestésicos Locais , Drenagem/efeitos adversos , Levobupivacaína
2.
Knee Surg Sports Traumatol Arthrosc ; 29(2): 586-593, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32279109

RESUMO

PURPOSE: The purpose of this study was to compare the effectiveness of a flexion spacer in the clinical and radiological outcomes of patients who underwent total knee arthroplasty (TKA) and to compare these patients to a group of patients subjected to the same type of surgery but without the use of a flexion spacer. It was hypothesized that patients who underwent TKA using a flexion spacer would have better clinical and radiological outcomes than those without a flexion spacer in both short- and medium-term follow-ups. METHODS: A consecutive series of patients undergoing TKA were included, yielding 20 patients in the study group. The control group was identified from the consultant database of the senior author, yielding 21 patients who underwent the same operation. All 41 patients received a Vanguard Knee System (Zimmer-Biomet, Warsaw, Indiana, USA). Cases were defined as those patients who had undergone TKA using a flexion spacer device for gap balancing; controls were defined as patients who had undergone TKA without the support of a flexion spacer device. Patients were clinically and radiographically evaluated at two consecutive follow-ups: T1-13.1 ± 1.3 months and T2-108 ± 6 months. Clinical evaluation was performed using the Knee Society Scoring System and the Western Ontario, McMaster Universities Osteoarthritis Index score. Radiographic evaluation included the femoral angle (α), the tibial angle (ß), the sagittal femoral (γ) angle and the tibial slope (δ). Furthermore, the lateral patellofemoral angle (LPFA) and the Caton-Deschamps index were evaluated. RESULTS: No statistically significant clinical differences were found between the two groups at T1 and T2; moreover, the clinical outcomes of the two groups were stable between the two follow-ups, with no significant improvement or worsening. Radiographic evaluation showed no difference in the two groups between T1 and T2; the only significant radiographic difference between the two groups concerned the LPFA (both at 30° and 60°) at each follow-up, which was significantly greater in cases than in controls (p = 0.001). CONCLUSIONS: The current study demonstrates that the use of a flexion spacer significantly improves radiographic patello-femoral tracking, although no significant clinical differences were found between the two groups. LEVEL OF EVIDENCE: Case-control study, level III.


Assuntos
Artroplastia do Joelho/instrumentação , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Articulação Patelofemoral/diagnóstico por imagem , Articulação Patelofemoral/cirurgia , Idoso , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Estudos de Casos e Controles , Humanos , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Articulação Patelofemoral/fisiopatologia , Complicações Pós-Operatórias , Radiografia , Amplitude de Movimento Articular , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA