Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
BACKGROUND: The present population-based cohort study investigated long-term mortality after surgical aortic valve replacement (AVR) with bioprosthetic (B) or mechanical aortic valve prostheses (M) in a European social welfare state. METHODS: We analysed patient data from health insurance records covering 98% of the Austrian population between 2010 and 2018. Subsequent patient-level record linkage with national health data provided patient characteristics and clinical outcomes. Further reoperation, myocardial infarction, heart failure and stroke were evaluated as secondary outcomes. RESULTS: A total of 13,993 patients were analysed and the following age groups were examined separately: <50 years (727 patients: 57.77% M, 42.23% B), 50-65 years (2612 patients: 26.88% M, 73.12% B) and >65 years (10,654 patients: 1.26% M, 98.74% B). Multivariable Cox regression revealed that the use of B-AVR was significantly associated with higher mortality in patients aged 50-65 years compared to M-AVR (HR = 1.676 [1.289-2.181], p < 0.001). B-AVR also performed worse in a competing risk analysis regarding reoperation (HR = 3.483 [1.445-8.396], p = 0.005) and myocardial infarction (HR = 2.868 [1.255-6.555], p = 0.012). However, the risk of developing heart failure and stroke did not differ significantly after AVR in any age group. CONCLUSIONS: Patients aged 50-65 years who underwent M-AVR had better long-term survival, and a lower risk of reoperation and myocardial infarction. Even though anticoagulation is crucial in patients with M-AVR, we did not observe significantly increased stroke rates in patients with M-AVR. This evident survival benefit in recipients of mechanical aortic valve prostheses aged <65 years critically questions current guideline recommendations.
Assuntos
Bioprótese , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Acidente Vascular Cerebral , Valva Aórtica/cirurgia , Estudos de Coortes , Insuficiência Cardíaca/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Infarto do Miocárdio/etiologia , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do TratamentoRESUMO
Radiofrequency denervation has been established for many years as an important minimally invasive procedure for the treatment of chronic pain conditions. Positive experiences of many users for various indications are contrasted by a nonuniform evidence. With meticulous patient selection and correct assessment of the indications a longer term reduction of pain, a reduced need for analgesics and an improvement in the quality of life can be achieved. The aim of this interdisciplinary position paper is to present the value of radiofrequency denervation in the treatment of chronic pain. The summarized recommendations of the expert group are based on the available evidence and on the clinical experiences of Austrian centers that frequently implement the procedure. The position paper contains recommendations on patient selection and proven indications. We discribe safety aspects, complications, side effects and contraindications.
Assuntos
Dor Crônica , Dor Lombar , Articulação Zigapofisária , Áustria , Dor Crônica/terapia , Denervação , Humanos , Dor Lombar/cirurgia , Vértebras Lombares , Qualidade de Vida , Resultado do TratamentoAssuntos
Falência Renal Crônica , Pró-Proteína Convertase 9 , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anticorpos Monoclonais Humanizados/uso terapêutico , Anticolesterolemiantes/uso terapêutico , LDL-Colesterol/sangue , LDL-Colesterol/metabolismo , Falência Renal Crônica/terapia , Inibidores de PCSK9/uso terapêutico , Diálise RenalAssuntos
Embolia Pulmonar , Síncope , Hemorragia/etiologia , Humanos , Embolia Pulmonar/complicações , Síncope/etiologiaAssuntos
Fibrilação Atrial , Intervenção Coronária Percutânea , Anticoagulantes , Fibrinolíticos , Humanos , Piridinas , Tiazóis , Vitamina KRESUMO
Accumulating evidence shows that acute as well as chronic heart disease can directly contribute to an acute or chronic worsening of liver function and vice versa. Description and definition of cardiohepatic syndrome (CHS) in this review are based on the cardiorenal syndrome (CRS) concept. The eye-catching analogy between CHS and CRS is applied to facilitate an understanding of the pathophysiology and overall burden of disease for each of the proposed CHS subtypes, their natural course, and associated morbidity and mortality.
Assuntos
Insuficiência Cardíaca/diagnóstico , Falência Hepática/diagnóstico , Doença Crônica , Gerenciamento Clínico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Falência Hepática/fisiopatologia , Falência Hepática/terapia , Prognóstico , SíndromeRESUMO
There is a strong need for non-invasive detection of human atherosclerotic lesions. One of the radioisotopic approaches using Indium-111-HIG has been shown to accumulate in oxidized LDL-rich foam cells and inflammatory vascular lesions. Earlier human studies in 200 patients, 100 with peripheral vascular disease and 100 with carotid artery disease comparing In-111-HIG scintigraphy with sonographic data revealed a high sensitivity (70%-77%) but a very low specificity (33%-41%). At this time we concluded the approach "not promising" for human studies. However, clinical follow-up over 5 years now shows that those patients with positive In-111-HIG scintigraphy exhibited a significantly higher vascular morbidity (P<0,01) and mortality (P<0,01), especially in the immediate follow-up period. Retrospective analysis discovered higher CRP and isoprostane (8-epi-prostaglandin (PG) F2α) levels in HIG-positive patients at the time of scintigraphy. These findings indicate that In-111-HIG reflecting vascular lesions with a high inflammatory component, probably more prone to rupture, may identify a population at high vascular risk rather than a lesion at risk. The clinical impact of this finding should be assessed in prospective studies.
RESUMO
Right ventricular apical pacing (RVAP) with a left bundle branch block on the electrocardiogram may result in regional wall motion abnormalities and decreased left ventricular function (LVF). Furthermore, perfusion defects in dipyridamole technetium-99m-methoxisobutylisonitrile ((99m)Tc-MIBI) myocardial perfusion imaging may occur despite a normal coronary angiogram. In a 68 years old patient, RVAP resulted in regional wall motion abnormalities, markedly decreased LVF and perfusion defects in dipyridamole (99m)Tc-MIBI myocardial perfusion imaging by single photon emission tomography (SPET). Coronary angiography excluded coronary heart disease. Reprogramming of the pacemaker resulted in physiologic activation of the ventricles. Echocardiography showed a normal LV systolic function. Repeated myocardial perfusion imaging was unremarkable. In conclusion, our case confirms thatRVAP may lead to scintigraphic perfusion defects and wall motion abnormalities despite a normal coronary angiogram and this differentiate between ischemia-induced perfusion defects.
Assuntos
Artefatos , Estimulação Cardíaca Artificial/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Idoso , Diagnóstico Diferencial , Humanos , MasculinoRESUMO
OBJECTIVES: Limited data are available from randomized trials comparing outcomes between transcatheter aortic valve replacement (TAVR) and surgery in patients with different risks and with follow-up of at least 4 years or longer. In this large, population-based cohort study, long-term mortality and morbidity were investigated in patients undergoing aortic valve replacement (AVR) for severe aortic stenosis using a surgically implanted bioprosthesis (surgical/biological aortic valve replacement; sB-AVR) or TAVR. METHODS: Individual data from the Austrian Insurance Funds from 2010 through 2020 were analysed. The primary outcome was all-cause mortality, assessed in the overall and propensity score-matched populations. Secondary outcomes included reoperation and cardiovascular events. RESULTS: From January 2010 through December 2020, a total of 18 882 patients underwent sB-AVR (n = 11 749; 62.2%) or TAVR (n = 7133; 37.8%); median follow-up was 5.8 (95% CI 5.7-5.9) years (maximum 12.3 years). The risk of all-cause mortality was higher with TAVR compared with sB-AVR: hazard ratio 1.552, 95% confidence interval (CI) 1.469-1.640, P < 0.001; propensity score-matched hazard ratio 1.510, 1.403-1.625, P < 0.001. Estimated median survival was 8.8 years (95% CI 8.6-9.1) with sB-AVR versus 5 years (4.9-5.2) with TAVR. Estimated 5-year survival probability was 0.664 (0.664-0.686) with sB-AVR versus 0.409 (0.378-0.444) with TAVR overall, and 0.690 (0.674-0.707) and 0.560 (0.540-0.582), respectively, with propensity score matching. Separate subgroup analyses for patients aged 65-75 years and >75 years indicated a significant survival benefit in patients selected for sB-AVR in both groups. Other predictors of mortality were age, sex, previous heart failure, diabetes and chronic kidney disease. CONCLUSIONS: In this retrospective national population-based study, selection for TAVR was significantly associated with higher all-cause mortality compared with sB-AVR in patients ≥65 years with severe, symptomatic aortic stenosis in the >2-year follow-up.
Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/cirurgia , Seleção de Pacientes , Estudos Retrospectivos , Pontuação de Propensão , Próteses Valvulares Cardíacas , Resultado do Tratamento , Bioprótese , Fatores de Risco , SeguimentosRESUMO
OBJECTIVES: This population-based cohort study investigated mid-term outcome after surgical aortic valve replacement with a bioprosthetic or mechanical valve prosthesis in patients aged <50 years in a European social welfare state. METHODS: We analysed patient data from the main social insurance carriers in Austria (2010-2020). Subsequent patient-level record linkage with national health data provided patient characteristics and clinical outcome. Survival, reoperation, myocardial infarction, heart failure, embolic stroke or intracerebral haemorrhage, bleeding other than intracerebral haemorrhage and major adverse cardiac events were evaluated as outcomes. RESULTS: A total of 991 patients were analysed. Regarding demographics, no major differences between groups were observed. Multivariable Cox regression revealed no significant difference in overall survival (P = 0.352) with a median follow-up time of 6.2 years. Reoperation-free survival was decreased (hazard ratio = 1.560 [95% CI: 1.076-2.262], P = 0.019) and the risk for reoperation was increased (hazard ratio = 2.770 [95% CI: 1.402-5.472], P = 0.003) in patients who received bioprostheses. Estimated probability of death after reoperation was 0.23 (CL: 0.08-0.35) after 2 years and 0.34 (CL: 0.06-0.53) after 10 years over both groups. Regarding further outcomes, no significant differences between the two groups were observed. CONCLUSIONS: In patients below 50 years of age receiving aortic valve replacement, implantation of bioprostheses when compared to mechanical heart valve prostheses was associated with a significantly higher rate of reoperations and reduced reoperation-free survival. Nevertheless, we could not observe a difference in overall survival. However, long-term follow-up has to evaluate that a significantly lower rate of reoperations may translate in consistently improved long-term survival.