Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 89(5): 1915-1930, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36594439

RESUMO

PURPOSE: To combine a new two-stage N/2 ghost correction and an adapted L1-SPIRiT method for reconstruction of 7T highly accelerated whole-brain diffusion MRI (dMRI) using only autocalibration scans (ACS) without the need of additional single-band reference (SBref) scans. METHODS: The proposed ghost correction consisted of a 3-line reference approach in stage 1 and the reference-free entropy method in stage 2. The adapted L1-SPIRiT method was formulated within the 3D k-space framework. Its efficacy was examined by acquiring two dMRI data sets at 1.05-mm isotropic resolutions with a total acceleration of 6 or 9 (i.e., 2-fold or 3-fold slice and 3-fold in-plane acceleration). Diffusion analysis was performed to derive DTI metrics and estimate fiber orientation distribution functions (fODFs). The results were compared with those of 3D k-space GRAPPA using only ACS, all in reference to 3D k-space GRAPPA using both ACS and SBref (serving as a reference). RESULTS: The proposed ghost correction eliminated artifacts more robustly than conventional approaches. Our adapted L1-SPIRiT method outperformed 3D k-space GRAPPA when using only ACS, improving image quality to what was achievable with 3D k-space GRAPPA using both ACS and SBref scans. The improvement in image quality further resulted in an improvement in estimation performances for DTI and fODFs. CONCLUSION: The combination of our new ghost correction and adapted L1-SPIRiT method can reliably reconstruct 7T highly accelerated whole-brain dMRI without the need of SBref scans, increasing acquisition efficiency and reducing motion sensitivity.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador/métodos , Imagem de Difusão por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Artefatos
2.
NMR Biomed ; 36(8): e4929, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36940048

RESUMO

The goals of this study were to measure the apparent transverse relaxation time constant, T2 , of scyllo-inositol (sIns) in young and older healthy adults' brains and to investigate the effect of alcohol usage on sIns in young and older healthy adults' brains, using proton magnetic resonance spectroscopy (MRS) at 3 T. Twenty-nine young adults (age 21 ± 1 years) and 24 older adults (age 74 ± 3 years) participated in this study. MRS data were acquired from two brain regions (the occipital cortex and posterior cingulate cortex) at 3 T. The T2 of sIns was measured using a localization by adiabatic selective refocusing (LASER) sequence at various echo times, while the sIns concentrations were measured using a short-echo-time stimulated echo acquisition mode (STEAM) sequence. A trend towards lower T2 relaxation values of sIns in older adults was observed, although these were not significant. sIns concentration was higher with age in both brain regions and was significantly higher in the young when considering alcohol consumption of more than two drinks per week. This study shows that differences in sIns can be found in two distinct regions of the brain across two age groups, potentially reflecting normal aging. In addition, it is important to take into account alcohol consumption when reporting the sIns level in the brain.


Assuntos
Envelhecimento , Encéfalo , Adulto Jovem , Humanos , Idoso , Adulto , Recém-Nascido , Encéfalo/diagnóstico por imagem , Inositol , Consumo de Bebidas Alcoólicas
3.
Neuroimage ; 258: 119360, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35697132

RESUMO

T1-weighted divided by T2-weighted (T1w/T2w) myelin maps were initially developed for neuroanatomical analyses such as identifying cortical areas, but they are increasingly used in statistical comparisons across individuals and groups with other variables of interest. Existing T1w/T2w myelin maps contain radiofrequency transmit field (B1+) biases, which may be correlated with these variables of interest, leading to potentially spurious results. Here we propose two empirical methods for correcting these transmit field biases using either explicit measures of the transmit field or alternatively a 'pseudo-transmit' approach that is highly correlated with the transmit field at 3T. We find that the resulting corrected T1w/T2w myelin maps are both better neuroanatomical measures (e.g., for use in cross-species comparisons), and more appropriate for statistical comparisons of relative T1w/T2w differences across individuals and groups (e.g., sex, age, or body-mass-index) within a consistently acquired study at 3T. We recommend that investigators who use the T1w/T2w approach for mapping cortical myelin use these B1+ transmit field corrected myelin maps going forward.


Assuntos
Imageamento por Ressonância Magnética , Bainha de Mielina , Viés , Humanos , Imageamento por Ressonância Magnética/métodos
4.
Magn Reson Med ; 87(5): 2111-2119, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34866226

RESUMO

PURPOSE: The aim of the study is to optimize the performance of localized 1 H MRS sequences at 3T, using the entire spin system of N-acetyl aspartate (NAA) as an example of the large chemical shift spread of all the metabolites routinely detected in vivo, including the amide region. We specifically focus on the design of the suitable broadband excitation radiofrequency (RF) pulses to minimize chemical shift artifacts. METHODS: The performance of the excitation and refocusing pulse shapes is evaluated with respect to NAA localization. Two new excitation RF pulses are developed to achieve optimized performance in the brain using single-voxel 1 H MRS at 3T. Numerical simulations and in vivo experiments are carried out to demonstrate the performance of the RF pulses. RESULTS: New excitation RF pulses with the same B1 requirements but larger excitation bandwidth (up to a factor of 2) are shown to significantly reduce localization artifacts. The large frequency spread of the entire NAA spin system necessitates the use of broadband excitation and refocusing pulses for MRS at 3T. CONCLUSION: To minimize chemical shift artifacts of metabolic compounds with spins in the amide area (>5 ppm) at 3T it is important to use broadband excitation and refocusing pulses.


Assuntos
Artefatos , Ondas de Rádio , Algoritmos , Encéfalo/diagnóstico por imagem , Frequência Cardíaca
5.
Magn Reson Med ; 87(6): 2613-2620, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35092085

RESUMO

PURPOSE: Advanced MRS protocols improve data quality and reproducibility relative to vendor-provided protocols; however, they are challenging to incorporate into the clinical workflow and require local MRS expertise for successful implementation. Here, we developed an automated advanced MRS acquisition protocol at 3T to facilitate acquisition of high-quality spectroscopic data without local MRS expertise. METHODS: First, a B0 shimming protocol was selected for automation by comparing 3 widely used B0 algorithms (2 vendor protocols and FAST(EST)MAP). Next, voxel-based B0 and B1 calibrations were incorporated into the consensus-recommended semi-LASER sequence and combined with an automated VOI prescription tool, a recently developed method for automated voxel prescription. The efficiency of collecting single-voxel data from a clinical cohort (N = 40) with the automated protocol (calibration time and fraction of usable datasets) was compared with the nonautomated semi-LASER protocol (N = 35) whereby all prescan calibrations were executed manually in the academic hospital setting with rotating MR technologists in the neuroradiology unit. RESULTS: A multi-iteration FAST(EST)MAP protocol resulted in narrower water linewidths than vendor's B0 shim protocols for data acquired from 6 brain locations (p < 1e-5) and was selected for automation. The automated B0 and B1 calibrations resulted in a time saving of ~4.5 minutes per voxel relative to the same advanced protocol executed manually. All spectra acquired with the automated protocol were usable, whereas only 86% of those collected with the manual protocol were usable and spectral quality was more variable. CONCLUSION: The plug-and-play advanced MRS protocol allows automated acquisition of high-quality MRS data with high success rate and consistency on a clinical 3T platform.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Reprodutibilidade dos Testes
6.
Magn Reson Med ; 86(1): 17-32, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33497006

RESUMO

PURPOSE: To develop a 3D composite adiabatic spectral-spatial pulse for refocusing in spin-echo spectroscopy acquisitions and to compare its performance against standard acquisition methods. METHODS: A 3D composite adiabatic pulse was designed by modulating a train of parallel transmit-optimized 2D subpulses with an adiabatic envelope. The spatial and spectral profiles were simulated and validated by experiments to demonstrate the feasibility of the design in both single and double spin-echo spectroscopy acquisitions. Phantom and in vivo studies were performed to evaluate the pulse performance and compared with semi-LASER with respect to localization performance, sequence timing, signal suppression, and specific absorption rate. RESULTS: Simultaneous 2D spatial localization with water and lipid suppression was achieved with the designed refocusing pulse, allowing high-quality spectra to be acquired with shorter minimum TE/TR, reduced SAR, as well as adaptation to spatially varying B0 and B1+ field inhomogeneities in both prostate and brain studies. CONCLUSION: The proposed composite pulse can serve as a more SAR efficient alternative to conventional localization methods such as semi-LASER at ultrahigh field for spin echo-based spectroscopy studies. Subpulse parallel-transmit optimization provides the flexibility to manage the tradeoff among multiple design criteria to accommodate different field strengths and applications.


Assuntos
Algoritmos , Encéfalo , Encéfalo/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Masculino , Imagens de Fantasmas , Próstata
7.
NMR Biomed ; 34(5): e4206, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-31930768

RESUMO

Diffusion-weighted (DW-) MRS investigates non-invasively microstructural properties of tissue by probing metabolite diffusion in vivo. Despite the growing interest in DW-MRS for clinical applications, little has been published on the reproducibility of this technique. In this study, we explored the optimization of a single-voxel DW-semi-LASER sequence for clinical applications at 3 T, and evaluated the reproducibility of the method under different experimental conditions. DW-MRS measurements were carried out in 10 healthy participants and repeated across three sessions. Metabolite apparent diffusion coefficients (ADCs) were calculated from mono-exponential fits (ADCexp ) up to b = 3300 s/mm2 , and from the diffusional kurtosis approach (ADCK ) up to b = 7300 s/mm2 . The inter-subject variabilities of ADCs of N-acetylaspartate + N-acetylaspartylglutamate (tNAA), creatine + phosphocreatine, choline containing compounds, and myo-inositol were calculated in the posterior cingulate cortex (PCC) and in the corona radiata (CR). We explored the effect of physiological motion on the DW-MRS signal and the importance of cardiac gating and peak thresholding to account for signal amplitude fluctuations. Additionally, we investigated the dependence of the intra-subject variability on the acquisition scheme using a bootstrapping resampling method. Coefficients of variation were lower in PCC than CR, likely due to the different sensitivities to motion artifacts of the two regions. Finally, we computed coefficients of repeatability for ADCexp and performed power calculations needed for designing clinical studies. The power calculation for ADCexp of tNAA showed that in the PCC seven subjects per group are sufficient to detect a difference of 5% between two groups with an acquisition time of 4 min, suggesting that ADCexp of tNAA is a suitable marker for disease-related intracellular alteration even in small case-control studies. In the CR, further work is needed to evaluate the voxel size and location that minimize the motion artifacts and variability of the ADC measurements.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Lasers , Adulto , Difusão , Dipeptídeos , Estudos de Viabilidade , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Reprodutibilidade dos Testes , Tamanho da Amostra , Fatores de Tempo , Adulto Jovem
8.
Neuroimage ; 223: 117349, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32898683

RESUMO

Resting state functional connectivity refers to the temporal correlations between spontaneous hemodynamic signals obtained using functional magnetic resonance imaging. This technique has demonstrated that the structure and dynamics of identifiable networks are altered in psychiatric and neurological disease states. Thus, resting state network organizations can be used as a diagnostic, or prognostic recovery indicator. However, much about the physiological basis of this technique is unknown. Thus, providing a translational bridge to an optimal animal model, the macaque, in which invasive circuit manipulations are possible, is of utmost importance. Current approaches to resting state measurements in macaques face unique challenges associated with signal-to-noise, the need for contrast agents limiting translatability, and within-subject designs. These limitations can, in principle, be overcome through ultra-high magnetic fields. However, imaging at magnetic fields above 7T has yet to be adapted for fMRI in macaques. Here, we demonstrate that the combination of high channel count transmitter and receiver arrays, optimized pulse sequences, and careful anesthesia regimens, allows for detailed single-subject resting state analysis at high resolutions using a 10.5 Tesla scanner. In this study, we uncover thirty spatially detailed resting state components that are highly robust across individual macaques and closely resemble the quality and findings of connectomes from large human datasets. This detailed map of the rsfMRI 'macaque connectome' will be the basis for future neurobiological circuit manipulation work, providing valuable biological insights into human connectomics.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Animais , Feminino , Processamento de Imagem Assistida por Computador/métodos , Macaca fascicularis , Macaca mulatta , Masculino , Vias Neurais/fisiologia , Razão Sinal-Ruído
9.
Radiology ; 297(2): 304-312, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32840468

RESUMO

Background Diffusion-weighted imaging (DWI) shows promise in detecting and monitoring breast cancer, but standard spin-echo (SE) echo-planar DWI methods often have poor image quality and low spatial resolution. Proposed alternatives include readout-segmented (RS) echo-planar imaging and axially reformatted (AR)-simultaneous multislice (SMS) imaging. Purpose To compare the resolution and image quality of standard SE echo-planar imaging DWI with two high-spatial-resolution alternatives, RS echo-planar and AR-SMS imaging, for breast imaging. Materials and Methods In a prospective study (2016-2018), three 5-minute DWI protocols were acquired at 3.0 T, including standard SE echo-planar imaging, RS echo-planar imaging with five segments, and AR-SMS imaging with four times slice acceleration. Participants were women undergoing breast MRI either as part of a treatment response clinical trial or undergoing breast MRI for screening or suspected cancer. A commercial breast phantom was imaged for resolution comparison. Three breast radiologists reviewed images in random order, including clinical images indicating the lesion, images with b value of 800 sec/mm2, and apparent diffusion coefficient (ADC) maps from the three randomly labeled DWI methods. Readers measured the longest dimension and lesion-average ADC on three DWI methods, reported measurement confidence, and rated or ranked the quality of each image. The scores were fit to a linear mixed-effects model with intercepts for reader and subject. Results The smallest feature (1 mm) was only detectible in a phantom on images from AR-SMS DWI. Thirty lesions from 28 women (mean age, 50 years ± 13 [standard deviation]) were evaluated. On the five-point Likert scale for image quality, AR-SMS imaging scored 1.31 points higher than SE echo-planar imaging and 0.74 points higher than RS echo-planar imaging, whereas RS echo-planar imaging scored 0.57 points higher than SE echo-planar imaging (all P < .001). Conclusion The axially reformatted simultaneous multislice protocol was rated highest for image quality, followed by the readout-segmented echo-planar imaging protocol. Both were rated higher than the standard spin-echo echo-planar imaging. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Partridge in this issue.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Meios de Contraste , Imagem Ecoplanar/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
10.
Magn Reson Med ; 84(4): 1747-1762, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32115756

RESUMO

PURPOSE: In this study, we sought to develop a self-navigation strategy for improving the reconstruction of diffusion weighted 3D multishot echo planar imaging (EPI). We propose a method for extracting the phase correction information from the acquisition itself, eliminating the need for a 2D navigator, further accelerating the acquisition. METHODS: In-vivo acquisitions at 3T with 0.9 mm and 1.5 mm isotropic resolutions were used to evaluate the performance of the self-navigation strategy. Sensitivity to motion was tested using a large difference in pitch position of the head. Using a multishell diffusion weighted acquisition, tractography results were obtained at (0.9 mm)3 to validate the quality with conventional acquisition. RESULTS: The use of 3D multislab EPI with self-navigation enables 3D diffusion-weighted spin echo EPI acquisitions that have the same efficiency as 2D single-shot acquisition. For matched acquisition time the image signal-to-noise ratio (SNR) between 3D and 2D acquisition is shown to be comparable for whole-brain coverage with (1.5 mm)3 resolution and for (0.9 mm)3 resolution the 3D acquisition has higher SNR than what can be obtained with 2D acquisitions using current state-of-art multiband techniques. The self-navigation technique was shown to be stable under inter-volume motion. In tractography analysis, the higher resolution afforded by our technique enabled clear delineation of the tapetum and posterior corona radiata. CONCLUSION: The proposed self-navigation approach utilized a self-consistent phase in 3D diffusion weighted acquisitions. Its efficiency and stability were demonstrated for a plurality of common acquisitions. The proposed self-navigation approach allows for faster acquisition of 3D multishot EPI desirable for large field of view and/or higher resolution.


Assuntos
Imagem Ecoplanar , Interpretação de Imagem Assistida por Computador , Algoritmos , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Reprodutibilidade dos Testes
11.
Magn Reson Med ; 84(4): 1947-1960, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32187742

RESUMO

PURPOSE: Simultaneous multislab (SMSb) 4D flow MRI was developed and implemented at 7T for accelerated acquisition of the 3D blood velocity vector field in both carotid bifurcations. METHODS: SMSb was applied to 4D flow to acquire blood velocities in both carotid bifurcations in sagittal orientation using a local transmit/receive coil at 7T. B1+ transmit efficiency was optimized by B1+ shimming. SMSb 4D flow was obtained in 8 healthy subjects in single-band (SB) and multiband (MB) fashion. Additionally, MB data were retrospectively undersampled to simulate GRAPPA R = 2 (MB2_GRAPPA2), and both SB datasets were added to form an artificial MB dataset (SumSB). The band separation performance was quantified by signal leakage. Peak velocity and total flow values were calculated and compared to SB via intraclass correlation analysis (ICC). RESULTS: Clean slab separation was achieved yielding a mean signal leakage of 13% above the mean SB noise level. Mean total flow for MB2, SumSB, and MB_GRAPPA2 deviated less than 9% from the SB values. Peak velocities averaged over all vessels and subjects were 0.48 ± 0.11 m/s for SB, 0.47 ± 0.12 m/s for SumSB, 0.50 ± 0.13 m/s for MB2, and 0.53 ± 0.13 m/s for MB2_GRAPPA2. ICC revealed excellent absolute agreement and consistency of total flow for all methods compared to SB2. Peak velocity showed good to excellent agreement and consistency for SumSB and MB2 and MB2_GRAPPA2 method showed poor to excellent agreement and good to excellent consistency. CONCLUSION: Simultaneous multislab 4D Flow MRI allows accurate quantification of total flow and peak velocity while reducing scan times.


Assuntos
Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
Neuroimage ; 184: 396-408, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30237033

RESUMO

We investigate the utility of radiofrequency (RF) parallel transmission (pTx) for whole-brain resting-state functional MRI (rfMRI) acquisition at 7 Tesla (7T). To this end, Human Connectome Project (HCP)-style data acquisitions were chosen as a showcase example. Five healthy subjects were scanned in pTx and single-channel transmit (1Tx) modes. The pTx data were acquired using a prototype 16-channel transmit system and a commercially available Nova 8-channel transmit 32-channel receive RF head coil. Additionally, pTx single-spoke multiband (MB) pulses were designed to image sagittal slices. HCP-style 7T rfMRI data (1.6-mm isotropic resolution, 5-fold slice and 2-fold in-plane acceleration, 3600 image volumes and ∼ 1-h scan) were acquired with pTx and the results were compared to those acquired with the original 7T HCP rfMRI protocol. The use of pTx significantly improved flip-angle uniformity across the brain, with coefficient of variation (i.e., std/mean) of whole-brain flip-angle distribution reduced on average by ∼39%. This in turn yielded ∼17% increase in group temporal SNR (tSNR) as averaged across the entire brain and ∼10% increase in group functional contrast-to-noise ratio (fCNR) as averaged across the grayordinate space (including cortical surfaces and subcortical voxels). Furthermore, when placing a seed in either the posterior parietal lobe or putamen to estimate seed-based dense connectome, the increase in fCNR was observed to translate into stronger correlation of the seed with the rest of the grayordinate space. We have demonstrated the utility of pTx for slice-accelerated high-resolution whole-brain rfMRI at 7T; as compared to current state-of-the-art, the use of pTx improves flip-angle uniformity, increases tSNR, enhances fCNR and strengthens functional connectivity estimation.


Assuntos
Encéfalo/fisiologia , Conectoma/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ondas de Rádio , Descanso/fisiologia , Adulto Jovem
13.
Magn Reson Med ; 82(6): 1984-1992, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31297889

RESUMO

PURPOSE: To demonstrate feasibility and performance of prospective motion and B0 shim correction for MRS in human brain at 7T. METHODS: Prospective motion correction using an optical camera and linear B0 shim correction using FASTMAP-like navigators were implemented into a semi-LASER sequence. The effect of motion on spectral quality was assessed without and with prospective correction in prefrontal cortex in 11 subjects. RESULTS: Without prospective motion and shim correction, motion resulted in considerable degradation of MR spectra (broader linewidth, lower signal-to-noise ratio, degraded water suppression). With prospective motion and shim correction, spectral quality remained excellent despite motion. Prospective motion correction alone was not sufficient to prevent degradation of spectral quality. CONCLUSION: Prospective motion and B0 shim correction is feasible at 7T and should help improve the robustness of MRS, particularly in motion-prone populations.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Espectroscopia de Ressonância Magnética , Movimento (Física) , Adulto , Idoso , Algoritmos , Artefatos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Córtex Pré-Frontal/diagnóstico por imagem , Razão Sinal-Ruído
14.
Magn Reson Med ; 81(4): 2624-2631, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30387902

RESUMO

PURPOSE: Correction of Nyquist ghosts for single-shot spin-echo EPI using the standard 3-line navigator often fails in breast DWI because of incomplete fat suppression, respiration, and greater B0 inhomogeneity. The purpose of this work is to compare the performance of the 3-line navigator with 4 data-driven methods termed "referenceless methods," including 2 previously proposed in literature, 1 introduced in this work, and finally a combination of all 3, in breast DWI. METHODS: Breast DWI was acquired for 41 patients with SS SE-EPI. Raw data was corrected offline with the standard 3-line navigator and 4 referenceless methods, which modeled the ghost as a linear phase error and minimized 3 unique cost functions as well as the median solution of all 3. Ghost levels were evaluated based on the signal intensity in the background region, defined by a mask auto-generated from a T1 -weighted anatomical image. Ghost intensity measurements were fit to a linear mixed model including ghost correction method and b-value as covariates. RESULTS: All 4 referenceless methods outperformed the standard 3-line navigator with statistical significance at all 4 b-values tested (b = 0, 100, 600, and 800 s/mm2 ). CONCLUSIONS: Referenceless methods provide a robust way to reduce Nyquist ghosts in breast DWI without the need for any additional calibration scan.


Assuntos
Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Algoritmos , Artefatos , Calibragem , Simulação por Computador , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Modelos Lineares , Distribuição Normal , Imagens de Fantasmas , Razão Sinal-Ruído
15.
Magn Reson Med ; 79(6): 2896-2901, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29044690

RESUMO

PURPOSE: To measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffusion gradients. METHODS: Diffusion-weighted spectra were acquired from the prefrontal cortex in five healthy subjects using STEAM (echo time [TE]/mixing time [TM]/pulse repetition time [TR] = 21.22/105/3000 ms, b-values = 0 and 3172 s/mm2 ) and PRESS (TE/TR = 54.2/3000 ms, b-values = 0 and 2204 s/mm2 ). Diffusion weighting was applied using bipolar gradients in three orthogonal directions. Post-processed spectra were analyzed with LCModel, and the trace/3 ADC values were calculated. RESULTS: Comparable trace/3 ADC values (0.14-0.18 µm2 /ms) were obtained for five main metabolites with both methods. These metabolites were quantified with Cramér-Rao lower bounds below 15%. CONCLUSION: The ADC values of the five main metabolites were successfully measured in the human brain at 3T with eliminated directional dependence. Both STEAM and PRESS can be used to probe the diffusivity of metabolites in normal brain and various pathologies on the clinical scanner with slightly higher precision achieved with STEAM for glutamate and myo-inositol. Magn Reson Med 79:2896-2901, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Substância Cinzenta/diagnóstico por imagem , Córtex Pré-Frontal/diagnóstico por imagem , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Neuroglia/metabolismo , Neurônios/metabolismo , Prótons , Razão Sinal-Ruído , Adulto Jovem
16.
Magn Reson Med ; 79(3): 1260-1265, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28691380

RESUMO

PURPOSE: The goal of this study was to measure and compare the apparent transverse relaxation time constants (T2 ) of five intracellular metabolites using localization by adiabatic selective refocusing (LASER) and point-resolved spectroscopy (PRESS) sequences in the human brain at 3 T. METHODS: Five healthy subjects were studied at 3 T. 1 H spectra from the prefrontal cortex were acquired at six different echo times using LASER and PRESS sequences. Postprocessed data were analyzed with LCModel, and the resulting amplitudes were fitted using a mono-exponential decay function to determine the T2 of metabolites. RESULTS: Twenty-one percent higher apparent T2 values for the singlet resonances of N-acetyl aspartate, total creatine, and total choline were measured with LASER as compared with PRESS, whereas comparable apparent T2 values were measured for strongly coupled metabolites, glutamate, and myo-inositol, with both sequences. CONCLUSIONS: Reliable T2 measurements were obtained with both sequences for the five major intracellular metabolites. The LASER sequence appears to be more efficient in suppressing the diffusion component for singlets (having nonexchangeable protons) compared to J-coupled metabolites. Magn Reson Med 79:1260-1265, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Química Encefálica/fisiologia , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Adulto Jovem
17.
Magn Reson Med ; 79(2): 701-710, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28497465

RESUMO

PURPOSE: To introduce a method of designing single and parallel transmit (pTx) 3D adiabatic π pulses for inverting and refocusing spins that are insensitive to transmit B1 ( B1+) inhomogeneity. THEORY AND METHODS: A 3D adiabatic pulse is created by replacing each piece-wise constant element (or sub-pulse) of an adiabatic full passage (AFP) by a 2D selective pulse. In this study, the parent AFP is an HS1 and each sub-pulse is a 2D pulse derived from a jinc function designed using a spiral k-trajectory. Spatial selectivity in the third direction is achieved by blipping the slab-selective gradient between sub-pulses, yielding a rectangular slab profile identical to that of the parent AFP. The slew-rate limited sub-pulse can be undersampled utilizing pTx, thus shortening the overall pulse width. Simulations and experiments demonstrate the quality of spatial selectivity and adiabaticity achievable. RESULTS: The 3D adiabatic pulse inverts and refocus spins in a sharply demarcated cylindrical volume. When stepping RF amplitude, an adiabatic threshold is observed above which the flip angle remains π. Experimental results demonstrate that pTx is an effective means to significantly improve pulse performance. CONCLUSION: A method of designing 3D adiabatic pulses insensitive to B1 inhomogeneity has been developed. pTx can shorten these pulses while retaining their adiabatic character. Magn Reson Med 79:701-710, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Ondas de Rádio , Encéfalo/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador
18.
Magn Reson Med ; 79(2): 815-825, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28488274

RESUMO

PURPOSE: To evaluate the feasibility of quantitative single breath-hold renal arterial spin labeling (ASL) imaging at 7T. METHODS: A single-shot fast spin echo FAIR (flow-sensitive alternating inversion recovery) method was used to perform two studies. First, a multi-delay perfusion study was performed to estimate the spin labeling temporal bolus width achievable with a local transceiver array coil at 7T. Second, with a conservatively defined bolus width, a quantitative perfusion study was performed using the single subtraction approach. To address issues of B1+ inhomogeneity/efficiency and excessive short-term specific absorption rates, various strategies were used, such as dynamic radiofrequency shimming and optimization. RESULTS: A conservative temporal bolus width of 600 ms determined from the multi-delay study was applied for single-subtraction imaging to measure the renal blood flow in the cortex and medulla: 303 ± 31.8 and 91.3 ± 15.2 (mL/100 g/min), respectively. The estimated spatial and temporal signal-to-noise ratios of renal perfusion measurements were 3.8 ± 0.7 and 2.4 ± 0.6 for the cortex, and 2.2 ± 0.6 and 1.4 ± 0.2 for the medulla. CONCLUSION: With proper management of field strength specific challenges, quantitative renal ASL imaging can be achieved at 7T within a single breath-hold. Magn Reson Med 79:815-825, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Suspensão da Respiração , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
19.
Magn Reson Med ; 80(5): 1857-1870, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29603381

RESUMO

PURPOSE: Investigating the utility of RF parallel transmission (pTx) for Human Connectome Project (HCP)-style whole-brain diffusion MRI (dMRI) data at 7 Tesla (7T). METHODS: Healthy subjects were scanned in pTx and single-transmit (1Tx) modes. Multiband (MB), single-spoke pTx pulses were designed to image sagittal slices. HCP-style dMRI data (i.e., 1.05-mm resolutions, MB2, b-values = 1000/2000 s/mm2 , 286 images and 40-min scan) and data with higher accelerations (MB3 and MB4) were acquired with pTx. RESULTS: pTx significantly improved flip-angle detected signal uniformity across the brain, yielding ∼19% increase in temporal SNR (tSNR) averaged over the brain relative to 1Tx. This allowed significantly enhanced estimation of multiple fiber orientations (with ∼21% decrease in dispersion) in HCP-style 7T dMRI datasets. Additionally, pTx pulses achieved substantially lower power deposition, permitting higher accelerations, enabling collection of the same data in 2/3 and 1/2 the scan time or of more data in the same scan time. CONCLUSION: pTx provides a solution to two major limitations for slice-accelerated high-resolution whole-brain dMRI at 7T; it improves flip-angle uniformity, and enables higher slice acceleration relative to current state-of-the-art. As such, pTx provides significant advantages for rapid acquisition of high-quality, high-resolution truly whole-brain dMRI data.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Algoritmos , Conectoma , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
20.
Neuroimage ; 154: 23-32, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-27894889

RESUMO

Whole-brain functional magnetic resonance imaging (fMRI), in conjunction with multiband acceleration, has played an important role in mapping the functional connectivity throughout the entire brain with both high temporal and spatial resolution. Ultrahigh magnetic field strengths (7T and above) allow functional imaging with even higher functional contrast-to-noise ratios for improved spatial resolution and specificity compared to traditional field strengths (1.5T and 3T). High-resolution 7T fMRI, however, has primarily been constrained to smaller brain regions given the amount of time it takes to acquire the number of slices necessary for high resolution whole brain imaging. Here we evaluate a range of whole-brain high-resolution resting state fMRI protocols (0.9, 1.25, 1.5, 1.6 and 2mm isotropic voxels) at 7T, obtained with both in-plane and slice acceleration parallel imaging techniques to maintain the temporal resolution and brain coverage typically acquired at 3T. Using the processing pipeline developed by the Human Connectome Project, we demonstrate that high resolution images acquired at 7T provide increased functional contrast to noise ratios with significantly less partial volume effects and more distinct spatial features, potentially allowing for robust individual subject parcellations and descriptions of fine-scaled patterns, such as visuotopic organization.


Assuntos
Conectoma/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA