Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ultrasound Obstet Gynecol ; 44(1): 31-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24448754

RESUMO

OBJECTIVES: To determine the effect of different ultrasound machine-probe combinations on nuchal translucency (NT) measurements and to assess how this impacts on the accuracy of the NT-derived component of first-trimester screening for trisomy 21. METHODS: Sixteen different ultrasound machine-probe combinations were used for axial measurement of 2.0-, 3.0- and 4.0-mm spaced targets in an ultrasound phantom. Differences between the measured and known values were determined. The mean of the axial measurements was used to calculate adjusted risks for trisomy 21, given specific clinical scenarios. RESULTS: Differences observed using different machine-probe combinations for the 2.0-mm target ranged from 1.8-2.2 mm; for the 3.0-mm target, 2.7-3.2 mm; and for the 4-mm target, 3.7-4.3 mm, and exceeded those due to intraobserver variability. For a fetal crown-rump length of 50.0 mm and NT measurement of 2.0 mm, the maximum/minimum measurements in the fetus of a 40-year-old woman led to derived risks ranging from 1 in 32 (NT, 2.2 mm) to 1 in 189 (NT, 1.8 mm) and in the fetus of a 20-year-old with an NT of 3.0 mm these ranged from 1 in 102 (NT, 3.2 mm) to 1 in 160 (NT, 2.7 mm). CONCLUSIONS: We have described the effect of machine-probe combinations on small but very precise ultrasound measurements. Such machine-probe combinations led to greater variability than those ascribed to intraobserver differences, and significantly affected the screening risk for the same fixed measurement. This finding has implications for Down syndrome screening algorithms and audit of ultrasound operators. Furthermore, most ultrasound machines are neither calibrated nor specified for measurements of tenths of a mm.


Assuntos
Síndrome de Down/diagnóstico por imagem , Medição da Translucência Nucal/instrumentação , Adulto , Calibragem , Feminino , Humanos , Modelos Lineares , Medição da Translucência Nucal/normas , Variações Dependentes do Observador , Gravidez , Primeiro Trimestre da Gravidez
2.
Ultrasound Obstet Gynecol ; 40(2): 194-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22190416

RESUMO

OBJECTIVE: To investigate the effect of use of different machine-probe combinations on measurement variability and to assess how this variability impacts on accuracy of pregnancy dating. METHODS: Sixteen different ultrasound machine-probe combinations were used for lateral measurement of targets spaced 10 and 40 mm apart and axial measurement of targets spaced 10 and 50 mm apart in an ultrasound phantom, and differences between the measured and true values were determined. The mean of the 40-mm lateral measurements was used to estimate gestational age using standard obstetric dating tables for crown-rump length (CRL) and femur length (FL) and the mean of the 50-mm axial measurements was used to estimate gestational age using the obstetric dating tables for biparietal diameter (BPD). RESULTS: As absolute measurements became larger, differences observed using different machine-probe combinations exceeded those due to intraobserver variability. Maximum dating differences for first-trimester CRL of 2 days (based on a measured CRL range of 39-42 mm), second-trimester BPD of 4 days (based on a measured BPD range of 49-52 mm) and FL of 9 days (based on a measured FL range of 39-42 mm) were observed when measurements were transposed to the equivalent gestational age using standard charts. CONCLUSION: Differences between measured and true values of biometric measurements reflect both machine-probe and intraobserver variability. Incremental first-trimester CRL growth with time is rapid, but second-trimester FL growth is much less so, leaving this lateral measurement more prone to both observer and machine-probe errors. The only axial growth measurement commonly performed is BPD where the measurement differences were intermediate between those of CRL and FL. The differences that can be ascribed to different equipment combinations are in many cases greater than those expected in clinical practice and are of potential importance in determining how fetal biometry is used for dating pregnancies.


Assuntos
Biometria/métodos , Idade Gestacional , Ultrassonografia Pré-Natal/métodos , Estatura Cabeça-Cóccix , Feminino , Humanos , Variações Dependentes do Observador , Gravidez , Ultrassonografia Pré-Natal/instrumentação
3.
Anaesthesia ; 67(1): 33-39, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21972913

RESUMO

Target controlled infusion (TCI) devices can be associated with significant safety concerns when used during magnetic resonance imaging (MRI). We tested the safety and compatibility of newer TCI systems in a 3-Tesla MRI environment. Two Asena PK and two Agilia TCI pumps were used to administer TCI propofol (at target blood concentrations of 0.5 and 6.0 µg.ml⁻¹) using the Marsh model under magnetic fields of up to 50 G with a T2-weighted sequence. We assessed the devices for projectile risk, accuracy of drug delivery, alarm function and effects on MR image quality. Both devices did not demonstrate any significant deflection at the tested field strengths, and performed within acceptable limits (cumulative error in total delivered volume < 3%; maximum 10-min interval error < 10%). The Asena pump caused minor artefacts on MR images. The TCI pumps tested perform well and safely implement pharmacokinetic software in a high magnetic field.


Assuntos
Análise de Falha de Equipamento , Bombas de Infusão/normas , Imageamento por Ressonância Magnética/métodos , Algoritmos , Anestésicos Intravenosos/administração & dosagem , Anestésicos Intravenosos/farmacocinética , Artefatos , Alarmes Clínicos , Simulação por Computador , Sistemas de Liberação de Medicamentos , Campos Eletromagnéticos , Falha de Equipamento , Humanos , Bombas de Infusão/efeitos adversos , Farmacocinética , Propofol/administração & dosagem , Propofol/farmacocinética , Ondas de Rádio , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA