RESUMO
AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data. METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available. Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV. CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants.
Assuntos
Cardiomiopatias , Taquicardia Ventricular , Humanos , Bloqueio de Ramo , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/complicações , Ventrículos do Coração , Eletrocardiografia , Cardiomiopatias/complicações , Cardiomiopatias/diagnósticoRESUMO
AIMS: Despite recent improvements, inappropriate shocks emitted by implanted subcutaneous implantable cardioverter defibrillators (S-ICDs) remain a challenge in 'real-life' practice. We aimed to study the pre-implant factors associated with inappropriate shocks for the latest generation of S-ICDs. METHODS AND RESULTS: Three-hundred patients implanted with the third-generation S-ICD system for primary or secondary prevention between January 2017 and March 2020 were included in this multicentre retrospective observational study. A follow-up of at least 6 months and pre-implant screening procedure data were mandatory for inclusion. During a mean follow-up of 22.8 (±11.4) months, 37 patients (12.3%) received appropriate S-ICD shock therapy, whereas 26 patients (8.7%) experienced inappropriate shocks (incidence 4.9 per 100 patient years). The total number of inappropriate shock episodes was 48, with nine patients experiencing multiple episodes. The causes of inappropriate shocks included supraventricular arrhythmias (34.6%) and cardiac (30.7%) or extra-cardiac noise (38.4%) oversensing. Using multivariate analysis, we explored the independent factors associated with inappropriate shocks. These were the availability of less than three sensing vectors during pre-implant screening [hazard ratio (HR), 0.33; 95% confidence interval (CI), 0.11-0.93; P = 0.035], low QRS/T wave ratio in Lead I (for a threshold <3; HR, 4.79; 95% CI, 2.00-11.49; P < 0.001), history of supraventricular tachycardia (HR, 8.67; 95% CI, 2.80-26.7; P < 0.001), and being overweight (body mass index > 25; HR, 2.66; 95% CI, 1.10-6.45; P = 0.03). CONCLUSION: Automatic pre-implant screening data are a useful quantitative predictor of inappropriate shocks. Electrocardiogram features should be taken into consideration along with other clinical factors to identify patients at high risk of inappropriate shocks.
Assuntos
Desfibriladores Implantáveis , Taquicardia Supraventricular , Humanos , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Supraventricular/etiologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Estudos Retrospectivos , Eletrocardiografia , Fatores de RiscoRESUMO
AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited cardiomyopathy associated with a high risk of ventricular arrhythmia (VA). Current guidelines recommend beta-blockers as first-line medical therapy and if ineffective, sotalol or amiodarone. We describe our experience, as a tertiary centre for ARVC, with the effectiveness and tolerance of flecainide in addition to beta-blockers to prevent VA in ARVC. METHODS AND RESULTS: We retrospectively included 100 consecutive ARVC patients who received flecainide with beta-blockers between May 1999 and November 2017. Treatment persistence and related side effects were assessed, as was VA-free survival on treatment, 24-h Holter monitoring and programmed ventricular stimulation (PVS) off- and on-treatment. Tolerance was good, with 10% flecainide discontinuations (lack of efficacy in six, atrial fibrillation in one, and side effects in three). No Brugada-induced electrocardiography pattern on flecainide or haemodynamic impairment was reported. Premature ventricular contraction burden at 24-h Holter monitoring was significantly decreased under treatment [median 415 (interquartile range, IQR 97-730) vs. 2370 (1572-3400) at baseline, P < 0.0001, n = 46]. Among the 33 patients with PVS under treatment, PVS was positive in 40% on-treatment vs. 94% off-treatment (P < 0.001). During a median follow-up of 47 months (IQR 23-73), 22 patients presented sustained VA on treatment, corresponding to an event rate of 5% [95% confidence interval (CI) (0.6-9)] at 1 year and 25% [95% CI (14-35)] at 5 years under treatment. No patient died. CONCLUSION: This study suggests that flecainide and beta-blockers association is complementary to implantable cardioverter-defibrillator and catheter ablation and is safe for treating persistent symptomatic VA in patients with ARVC.
Assuntos
Displasia Arritmogênica Ventricular Direita , Fibrilação Atrial , Desfibriladores Implantáveis , Taquicardia Ventricular , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/tratamento farmacológico , Fibrilação Atrial/tratamento farmacológico , Flecainida/efeitos adversos , Humanos , Estudos Retrospectivos , Sotalol , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamento farmacológico , Resultado do TratamentoRESUMO
AIMS: In arrhythmogenic cardiomyopathy (ACM), sustained ventricular tachycardia (VT) typically displays a left bundle branch block (LBBB) morphology while a right bundle branch block (RBBB) morphology is rare. The present study assesses the VT morphology in ACM patients with sustained VT and their clinical and genetic characteristics. METHODS AND RESULTS: Twenty-six centres from 11 European countries provided information on 954 ACM patients who had ≥1 episode of sustained VT spontaneously documented during patients' clinical course. Arrhythmogenic cardiomyopathy was defined according to the 2010 Task Force Criteria, and VT morphology according to the QRS pattern in V1. Overall, 882 (92.5%) patients displayed LBBB-VT alone and 72 (7.5%) RBBB-VT [alone in 42 (4.4%) or in combination with LBBB-VT in 30 (3.1%)]. Male sex prevalence was 79.3%, 88.1%, and 56.7% in the LBBB-VT, RBBB-VT, and LBBB + RBBB-VT groups, respectively (P = 0.007). First RBBB-VT occurred 5 years after the first LBBB-VT (46.5 ± 14.4 vs 41.1 ± 15.8 years, P = 0.011). An implanted cardioverter-defibrillator was more frequently implanted in the RBBB-VT (92.9%) and the LBBB + RBBB-VT groups (90%) than in the LBBB-VT group (68.1%) (P < 0.001). Mutations in PKP2 predominated in the LBBB-VT (65.2%) and the LBBB + RBBB-VT (41.7%) groups while DSP mutations predominated in the RBBB-VT group (45.5%). By multivariable analysis, female sex was associated with LBBB + RBBB-VT (P = 0.011) while DSP mutations were associated with RBBB-VT (P < 0.001). After a median follow-up of 103 (51-185) months, death occurred in 106 (11.1%) patients with no intergroup difference (P = 0.176). CONCLUSION: RBBB-VT accounts for a significant proportion of sustained VTs in ACM. Sex and type of pathogenic mutations were associated with VT type, female sex with LBBB + RBBB-VT, and DSP mutation with RBBB-VT.
Assuntos
Cardiomiopatias , Taquicardia Ventricular , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/terapia , Cardiomiopatias/complicações , Cardiomiopatias/epidemiologia , Cardiomiopatias/genética , Eletrocardiografia , Feminino , Humanos , Masculino , Prevalência , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/genéticaRESUMO
BACKGROUND: Cryoballoon ablation (CBA) as a first-line rhythm control strategy is superior to antiarrhythmic drugs (AADs) for preventing atrial fibrillation (AF) recurrence; the impact of first-line CBA on quality of life (QoL) and symptoms has not been well characterized. METHODS: Patients aged 18 to 75 with symptomatic paroxysmal AF naïve to rhythm control therapy were randomized (1:1) to CBA (Arctic Front Advance, Medtronic) or AAD (Class I or III). Symptoms and QoL were assessed at baseline, 1, 3, 6, 9, and 12 months using the EHRA classification and Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT) and SF-36v2 questionnaires. Symptomatic palpitations were evaluated via patient diary. RESULTS: Overall, 107 patients were randomized to CBA and 111 to AAD; crossovers occurred in 9%. Larger improvements in the AFEQT summary, subscale and treatment satisfaction scores were observed at 12 months with CBA vs AAD (all P <0.05). At 12 months, the mean adjusted difference in the AFEQT summary score was 9.9 points higher in the CBA group (95% CI: 5.5 -14.2, P <0.001). Clinically important improvements in the SF-36 physical and mental component scores were observed at 12 months in both groups, with no significant between group differences at this timepoint. In the CBA vs AAD group, larger improvements in EHRA class were observed at 6, 9 and 12 months (P <0.05) and the incidence rate of symptomatic palpitations was lower (4.6 vs 15.2 days/year post-blanking; IRR: 0.30, P <0.001). CONCLUSIONS: In patients with symptomatic AF, first-line CBA was superior to AAD for improving AF-specific QoL and symptoms. TRIAL REGISTRATION: ClinicalTrials.gov number: NCT01803438.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Adolescente , Adulto , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Humanos , Pessoa de Meia-Idade , Qualidade de Vida , Resultado do Tratamento , Adulto JovemRESUMO
AIMS: Treatment guidelines for patients with atrial fibrillation (AF) suggest that patients should be managed with an antiarrhythmic drug (AAD) before undergoing catheter ablation (CA). This study evaluated whether pulmonary vein isolation employing cryoballoon CA is superior to AAD therapy for the prevention of atrial arrhythmia (AA) recurrence in rhythm control naive patients with paroxysmal AF (PAF). METHODS AND RESULTS: A total of 218 treatment naive patients with symptomatic PAF were randomized (1 : 1) to cryoballoon CA (Arctic Front Advance, Medtronic) or AAD (Class I or III) and followed for 12 months. The primary endpoint was ≥1 episode of recurrent AA (AF, atrial flutter, or atrial tachycardia) >30 s after a prespecified 90-day blanking period. Secondary endpoints included the rate of serious adverse events (SAEs) and recurrence of symptomatic palpitations (evaluated via patient diaries). Freedom from AA was achieved in 82.2% of subjects in the cryoballoon arm and 67.6% of subjects in the AAD arm (HR = 0.48, P = 0.01). There were no group differences in the time-to-first (HR = 0.76, P = 0.28) or overall incidence [incidence rate ratio (IRR)=0.79, P = 0.28] of SAEs. The incidence rate of symptomatic palpitations was lower in the cryoballoon (7.61 days/year) compared with the AAD arm (18.96 days/year; IRR = 0.40, P < 0.001). CONCLUSIONS: Cryoballoon CA was superior to AAD therapy, significantly reducing AA recurrence in treatment naive patients with PAF. Additionally, cryoballoon CA was associated with lower symptom recurrence and a similar rate of SAEs compared with AAD therapy.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do TratamentoRESUMO
BACKGROUND: Ablation index (AI) is a new lesion quality marker that has been demonstrated to allow a high single-procedure arrhythmia-free survival in single-center studies. This prospective, multi-center study was designed to evaluate the reproducibility of pulmonary vein (PV) isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV isolation and were divided in four study groups according to operator's preference in choosing the ablation catheter (a contact force (ST) or contact force surround flow (STSF) catheter) and the AI setting (330-450 or 380-500 at anterior wall or posterior wall, respectively). RESULTS: At 12 months a high rate of freedom from AF recurrences was observed in patients with both paroxysmal and persistent AF (91% vs 83.3%; P = .039). There was no difference in the rate of AF recurrence among the four study groups (4.5% in group ST330-450, 12.2% in group ST 380-500, 14.9% in group STSF330-450, 9.4% in group STSF380-500; P = .083). Recurrence was also similar between patients treated with a ST (8%) or STSF catheter (12.1%; P = .2), and within patients targeting an AI settings of 330 to 450 (10.9%) or 380 to 500 (10.3%; P = .64). In patients with paroxysmal AF, there was no difference (P = .12) in the 1-year freedom from AF recurrence among 14 operators that performed ≥10 ablation procedure. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion resulted in high rate of 1-year freedom from AF recurrence, irrespective of the ablation catheters, AI settings, and operator.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Reprodutibilidade dos Testes , Resultado do TratamentoRESUMO
BACKGROUND: Atrial fibrillation (AF) ablation outcome is still operator dependent. Ablation Index (AI) is a new lesion quality marker that has been demonstrated to allow acute durable pulmonary vein (PV) isolation followed by a high single-procedure arrhythmia-free survival. This prospective, multicenter study was designed to evaluate the reproducibility of acute PV isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV encircling and were divided in four study groups according to operator preference in choosing the ablation catheter (a contact force [ST] or contact force surround flow [STSF] catheter) and the AI setting (330 at posterior and 450 at anterior wall or 380 at posterior and 500 at anterior wall). Radiofrequency was delivered targeting interlesion distance ≤6 mm. RESULTS: The rate of first-pass PV isolation (ST330 90 ± 16%, ST380 87 ± 19%, STSF330 90 ± 17%, STSF380 91 ± 15%, P = .585) was similar among the four study groups, whereas procedure (ST330 129 ± 44 minutes, ST380 144 ± 44 minutes, STSF330 120 ± 72 minutes, STSF380 125 ± 73 minutes, P < .001) and fluoroscopy time (ST330 542 ± 285 seconds, ST380 540 ± 416 seconds, STSF330 257 ± 356 seconds, STSF380 379 ± 454 seconds, P < 0.001) significantly differed. The difference in the rate of first-pass isolation was not statistical different (P = .06) among the 12 operators that performed at least 15 procedures. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion results in high and comparable rate of acute PV isolation among operator performing ablation with different catheters, AI settings, procedure, and fluoroscopy times.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Reprodutibilidade dos TestesRESUMO
OBJECTIVES: This study aimed to assess the impact of pacemaker mode programming on clinical outcomes in patients with high-degree atrioventricular conduction disturbance (AVCD) after transcatheter aortic valve implantation (TAVI). BACKGROUND: Although high-degree AVCD after TAVI can receive pacemaker, recovery of the AVCD is often observed. Specific pacemaker algorithms (AAI-DDD mode switch) are available which favor spontaneous atrioventricular conduction. METHODS: Of 1,621 consecutive multi-center TAVI patients, 269 (16.4%) received pacemaker. We retrospectively included 91 patients with persistent high-degree AVCD at hospital discharge. Pacemaker dependency was defined as absence, inadequate intrinsic ventricular rhythm, or ventricular pacing time > 95% on pacemaker interrogation during follow-up. Comparison of heart failure hospitalization and death between conventional DDD (cDDD) and other modes was examined (AAI-DDD and VVI). RESULTS: During a mean follow-up duration of 13 months, the pacemaker dependency rate was 52.8%. Patients with cDDD mode (N = 36: 40.0%) had significantly more pacemaker dependency. Multivariate analysis showed that cDDD mode was independently associated with pacemaker dependency (odds ratio = 3.63, P = 0.03). Moreover, cDDD patients had a significant higher incidence of heart failure hospitalization (Hospitalization: cDDD vs. others = 45.4% vs. 18.2%, P = 0.03) and had a higher incidence of mortality (Death: cDDD vs. the others = 27.0% vs. 4.4%, P = 0.06). CONCLUSIONS: Up to half of patients implanted for high-degree AVCD after TAVI had conduction recovery. Patients with cDDD programming at hospital discharge had more pacemaker dependency and a worse cardiac prognosis. Thus, pacemaker mode should be systematically set to promote spontaneous atrioventricular conduction in patients with pacemaker implantation after TAVI.
Assuntos
Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/efeitos adversos , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/mortalidade , Bloqueio Atrioventricular/fisiopatologia , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Hospitalização , Humanos , Masculino , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
BACKGROUND: Electrocardiographic screening before subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is unsuccessful in around 10% of cases. A personalized screening method, by slightly moving the electrodes, to obtain a better R/T ratio has been described to overcome traditional screening failure. OBJECTIVE: The objectives of the SIS study were to assess to what extent a personalized screening method improves eligibility for S-ICD implantation and to evaluate the inappropriate shock rate after such screening success. METHODS: All consecutive patients eligible for an S-ICD implantation were prospectively recruited across 20 French centers between December 2019 and January 2022. In case of traditional screening failure, patients received a second personalized screening. If at least 1 vector was positive, the personalized screening was considered successful, and the patient was eligible for implantation. RESULTS: The study included 474 patients (mean age, 50.4 ± 14.1 years; 77.4% men). Traditional screening was successful in 456 (96.2%) cases. This figure rose to 98.3% (n = 466; P = .002) when personalized screening was performed. All patients implanted after successful personalized screening had correct signal detection on initial device interrogation. Nevertheless, after 1-year follow-up, 3 of the 7 patients (43%) implanted with personalized screening experienced inappropriate shock vs 18 of the 427 patients (4.2%) with traditional screening and S-ICD implantation (P = .003). CONCLUSION: Traditional S-ICD screening was successful in our study in a high proportion of patients. Considering the small improvement in success of screening and a higher rate of inappropriate shock, a strategy of personalized screening cannot be routinely recommended. CLINICALTRIALS: gov identifier: NCT04101253.
RESUMO
The relations between endocardial voltage mapping and the genetic background of patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) have not been investigated so far. A total of 97 patients with proved or suspected ARVC who underwent 3-dimensional endocardial mapping and genetic testing have been retrospectively included. Presence, localization, and size of scar areas were correlated to ARVC diagnosis and the presence of a pathogenic variant. A total of 78 patients (80%) presented with some bipolar or unipolar scar on endocardial voltage mapping, whereas 43 carried pathogenic variants (44%). Significant associations were observed between presence of endocardial scars on voltage mapping and previous or inducible ventricular tachycardia, right ventricular function and dimensions, or electrocardiogram features of ARVC. A total of 60 of the 78 patients (77%) with an endocardial scar fulfilled the criteria for a definitive arrhythmogenic right ventricular dysplasia diagnosis versus 8 of 19 patients (42%) without scar (p = 0.003). Patients with a definitive diagnosis of ARVC had more scars from any location and the scars were larger in patients with ARVC. In the 68 patients with a definitive diagnosis of ARVC, the presence of any endocardial scar was similar whether an ARVC-causal mutation was present or not. Only scar extent was significantly greater in patients with pathogenic variants. There was no difference in the presence and characteristics of scars in PKP2 mutated versus other mutated patients. The 3-dimensional endocardial mapping could have an important role for refining ARVC diagnosis and may be able to detect minor forms with otherwise insufficient criteria for diagnosis. The trend for larger scar extent were observed in mutated patients, without any difference according to the mutated genes.
Assuntos
Displasia Arritmogênica Ventricular Direita , Ablação por Cateter , Taquicardia Ventricular , Humanos , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/genética , Cicatriz/complicações , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas/métodos , Endocárdio/patologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/genética , Ablação por Cateter/efeitos adversosRESUMO
BACKGROUND: Few data exist on the characteristics and outcomes of patients with arrhythmogenic right ventricular cardiomyopathy and advanced heart failure who undergo heart transplantation. AIM: To explore the pretransplant course and outcomes of patients with arrhythmogenic right ventricular cardiomyopathy after heart transplantation. METHODS: This observational retrospective monocentric study included all consecutive patients with arrhythmogenic right ventricular cardiomyopathy who underwent heart transplantation during a 13-year period (2006-2019) at Pitié-Salpêtrière University Hospital (Paris). RESULTS: A total of 23 patients with arrhythmogenic right ventricular cardiomyopathy underwent heart transplantation between 2006 and 2019. The median time from diagnosis to heart transplantation was 9 years, and the median age at transplantation was 50 years. At diagnosis, half of the patients had left ventricular dysfunction, 59% had extensive T-wave inversion and 43% had a history of sustained ventricular tachycardia. Only five patients were involved in intensive sport activity. Indications for heart transplantation were end-stage biventricular dysfunction in 13 patients, end-stage right ventricular heart failure in seven and electrical storm in three. Only three patients had pulmonary hypertension, and half of the patients had atrial arrhythmias. The survival rate 1 year after heart transplantation was 74% (95% confidence interval 53-88%). Eight patients experienced primary graft dysfunction needing extracorporeal membrane oxygenation. CONCLUSIONS: Patients with arrhythmogenic right ventricular cardiomyopathy who eventually needed heart transplantation mostly exhibited extended disease with biventricular dysfunction at diagnosis. Intensive sport activity did not seem to be a major determinant. Advanced heart failure usually occurred late in the course of the disease. Primary graft dysfunction after heart transplantation was frequent, and should be anticipated. Additional data are needed to identify the optimal timing for heart transplantation and predictors of end-stage heart failure in patients with arrhythmogenic right ventricular cardiomyopathy.
Assuntos
Displasia Arritmogênica Ventricular Direita , Insuficiência Cardíaca , Transplante de Coração , Disfunção Primária do Enxerto , Humanos , Pessoa de Meia-Idade , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/cirurgia , Estudos Retrospectivos , Transplante de Coração/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Progressão da DoençaRESUMO
BACKGROUND: In a preliminary study in patients hospitalized for catheter ablation of atrial fibrillation (AF), the atrial thrombus exclusion (ATE) score (stroke, hypertension, heart failure, and D-dimers >270 ng/mL) was developed to rule out the diagnosis of intra-atrial thrombus, with a negative predictive value (NPV) of 100%, and to avoid performing transesophageal echocardiography (TEE). OBJECTIVES: The present study was designed to prospectively confirm the NPV of the ATE score in an independent population. METHODS: Consecutive patients hospitalized for catheter ablation of AF or left atrial tachycardia (LAT) were prospectively enrolled in a multicenter study. D-dimer levels were measured within 48 hours before ablation. An ATE score of 0 was considered predictive of no thrombus. TEE was routinely performed at the beginning or just before the ablation procedure. The primary endpoint was the presence of atrial thrombus diagnosed by TEE. RESULTS: The analysis included 3,072 patients (53.3% paroxysmal AF, 36.7% persistent AF, and 10% LAT). A thrombus was detected in 29 patients (0.94%; 95% CI: 0.63%-1.35%), all on appropriate anticoagulant therapy. An ATE score of 0 was observed in 818 patients (26.6%), and the sensitivity, specificity, positive predictive value, and NPV were 93.1%, 26.8%, 1.2%, and 99.8%, respectively. Follow-up of the 2 false negative patients revealed the persistence of chronic organized thrombi. CONCLUSIONS: In patients hospitalized for catheter ablation of AF or LAT, the ATE score identifies a population at very low risk for atrial thrombus. In consultation with the patient, the cardiologist may consider not performing a preoperative TEE in case of an ATE score of 0.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Trombose , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Cardiopatias/diagnóstico , Trombose/epidemiologiaRESUMO
BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Reoperação/métodos , Recidiva , Resultado do TratamentoRESUMO
BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).
Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Estudos de Coortes , Resultado do Tratamento , Estudos Retrospectivos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapiaRESUMO
BACKGROUND: Centenarians have been proposed as a model of successful aging but recent studies suggest a high prevalence of cardiovascular diseases. Some findings on their electrocardiograms (ECGs) are simply age-related and others mirror underlying diseases. We aimed to identify ECG features truly associated with extreme age. METHODS: Retrospective analysis of 55 centenarians hospitalized between January 2000 and June 2010. Each centenarian was matched with three octogenarians according to gender, presence of hypertension, aortic stenosis, heart failure, and ischemic heart disease. RESULTS: A history of hypertension was present in 32 (58%) centenarians, aortic stenosis in 6 (11%), heart failure in 8 (15%), and ischemic heart disease in 6 (11%). Centenarians had a higher heart rate than octogenarians (81 ± 15 bpm vs. 72 ± 15 bpm, respectively, P < 0.001) but were less frequently on beta-blockers (7% vs. 36%, respectively, P < 0.001). Centenarians displayed more frequently atrial premature beats than octogenarians (18% vs. 3%, respectively, P < 0.001) but tended to have less atrial fibrillation (15% vs. 22% respectively, P = 0.21). Centenarians had more frequently left QRS axis deviation (48% vs. 28%, P = 0.009) and Q waves (14% vs. 1%, P = 0.02). QT interval was more prolonged in centenarians (446 ± 42 ms vs. 429 ± 39 ms, P = 0.008). Two centenarians (4%) and 24 (15%) octogenarians had a strictly normal ECG (P = 0.02). CONCLUSIONS: Abnormal ECG is a common finding in centenarians, with different characteristics than in younger elderly individuals. These differences are unrelated to the presence of cardiac diseases.
Assuntos
Eletrocardiografia/estatística & dados numéricos , Avaliação Geriátrica/métodos , Avaliação Geriátrica/estatística & dados numéricos , Cardiopatias/epidemiologia , Cardiopatias/fisiopatologia , Frequência Cardíaca , Fatores Etários , Idoso de 80 Anos ou mais , Arritmias Cardíacas , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Paris/epidemiologia , Estudos RetrospectivosRESUMO
BACKGROUND: The absence of pacing capabilities may reduce the appeal of subcutaneous implantable cardioverter-defibrillator (S-ICD) devices for patients at risk for conduction disorders or with antitachycardia pacing (ATP)/cardiac resynchronization (CRT) requirements. Reports of rates of S-ICD to transvenous implantable cardioverter-defibrillator (TV-ICD) system switch in real-world scenarios are limited. OBJECTIVE: The purpose of this study was to investigate the need for a subsequent transvenous (TV) device in patients implanted with an S-ICD and its predictors. METHODS: All patients implanted with an S-ICD were enrolled from the multicenter, real-world iSUSI (International SUbcutaneouS Implantable cardioverter defibrillator) Registry. The need for a TV device and its clinical reason, and appropriate and inappropriate device therapies were assessed. Logistic regression with Firth penalization was used to assess the association between baseline and procedural characteristics and the overall need for a subsequent TV device. RESULTS: A total of 1509 patients were enrolled (age 50.8 ± 15.8 years; 76.9% male; 32.0% ischemic; left ventricular ejection fraction 38% [30%-60%]). Over 26.5 [13.4-42.9] months, 155 (10.3%) and 144 (9.3%) patients experienced appropriate and inappropriate device therapies, respectively. Forty-one patients (2.7%) required a TV device (13 bradycardia; 10 need for CRT; 10 inappropriate shocks). Body mass index (BMI) >30 kg/m2 and chronic kidney disease (CKD) were associated with need for a TV device (odds ratio [OR] 2.57 [1.37-4.81], P = .003; and OR 2.67 [1.29-5.54], P = .008, respectively). CONCLUSION: A low rate (2.7%) of conversion from S-ICD to a TV device was observed at follow-up, with need for antibradycardia pacing, ATP, or CRT being the main reasons. BMI >30 kg/m2 and CKD predicted all-cause need for a TV device.
Assuntos
Desfibriladores Implantáveis , Insuficiência Renal Crônica , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Volume Sistólico , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda , Trifosfato de AdenosinaRESUMO
BACKGROUND: A few limited case series have shown that the subcutaneous implantable cardioverter-defibrillator (S-ICD) system is safe for teenagers and young adults, but a large-scale analysis currently is lacking. OBJECTIVES: The purpose of this study was to compare mid-term device-associated outcomes in a large real-world cohort of S-ICD patients, stratified by age at implantation. METHODS: Two propensity-matched cohorts of teenagers + young adults (≤30 years old) and adults (>30 years old) were retrieved from the ELISIR Registry. The primary outcome was the comparison of inappropriate shock rate. Complications, freedom from sustained ventricular arrhythmias, and overall and cardiovascular mortality were deemed secondary outcomes. RESULTS: Teenagers + young adults represented 11.0% of the entire cohort. Two propensity-matched groups of 161 patients each were used for the analysis. Median follow-up was 23.1 (13.2-40.5) months. In total, 15.2% patients experienced inappropriate shocks, and 9.3% device-related complications were observed, with no age-related differences in inappropriate shocks (16.1% vs 14.3%; P = .642) and complication rates (9.9% vs 8.7%; P = .701). At univariate analysis, young age was not associated with increased rates of inappropriate shocks (hazard ratio [HR] 1.204 [0.675-2.148]: P = .529). At multivariate analysis, use of the SMART Pass algorithm was associated with a strong reduction in inappropriate shocks (adjusted HR 0.292 [0.161-0.525]; P <.001), whereas arrhythmogenic right ventricular cardiomyopathy (ARVC) was associated with higher rates of inappropriate shocks (adjusted HR 2.380 [1.205-4.697]; P = .012). CONCLUSION: In a large multicenter registry of propensity-matched patients, use of the S-ICD in teenagers/young adults was safe and effective. The rates of inappropriate shocks and complications between cohorts were not significantly different. The only predictor of increased inappropriate shocks was a diagnosis of ARVC.
Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico , Displasia Arritmogênica Ventricular Direita/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Sistema de Registros , Resultado do Tratamento , Adulto JovemAssuntos
Cardiomiopatias/patologia , Septos Cardíacos/patologia , Hipertrofia Ventricular Direita/patologia , Imageamento por Ressonância Magnética , Sarcoidose/patologia , Taquicardia Ventricular/etiologia , Corticosteroides/uso terapêutico , Biópsia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/tratamento farmacológico , Fármacos Cardiovasculares/uso terapêutico , Ablação por Cateter , Terapia Combinada , Ciclofosfamida/uso terapêutico , Desfibriladores Implantáveis , Eletrocardiografia , Humanos , Hipertrofia Ventricular Direita/diagnóstico por imagem , Hipertrofia Ventricular Direita/etiologia , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Sarcoidose/tratamento farmacológico , Sarcoidose Pulmonar/diagnóstico , Sarcoidose Pulmonar/patologia , Síncope/etiologia , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/cirurgia , UltrassonografiaRESUMO
The new 5-year ventricular arrhythmia (VA) occurrence risk model is a major breakthrough for arrhythmia risk stratification in the challenging population of patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). In the original study, the model resulted in a 20.6% reduction in implantable cardioverter-defibrillator (ICD) placement compared with the 2015 consensus, for the same protection level. However, only internal validation was performed, limiting generalisation. We externally validated the model in a European tertiary care cohort of 128 patients with ARVC with restrictive indications for primary prevention ICD placement. Overall, 74% were men, none had VA history, and a single patient had an ICD at baseline. Median age at diagnosis was 38 years (interquartile range [IQR] 28-50). During a median follow-up of 7.8 years (IQR 6.1-9.7), 15 patients (12%) experienced VA. The model provided good discrimination, with a C-index for 5-year VA risk prediction of 0.84 (95% confidence interval 0.74-0.93). However, the model led to an overestimation of the 5-year VA risk when applying thresholds < 50%. With a < 10% predicted risk, no patient showed VA. With a 7.5% predicted risk, the ICD:VA ratio was 6.3 vs 3.4 in the original study. The model still outperformed the 2015 International Task Force Consensus. Overall, in a relatively large European ARVC cohort with restrictive indications for ICD placement, the ARVC model for VA prediction successfully identified ARVC patients with VA during follow-up. Yet, our study underscores the need for careful threshold selection, considering the model's associated risk overestimation in low- to intermediate-risk patients.