RESUMO
Novel computing technologies that imitate the principles of biological neural systems may offer low power consumption along with distinct cognitive and learning advantages. The development of reliable memristive devices capable of storing multiple states of information has opened up new applications such as neuromorphic circuits and adaptive systems. At the same time, the explosive growth of the printed electronics industry has expedited the search for advanced memory materials suitable for manufacturing flexible devices. Here, we demonstrate that solution-processed MoOx/MoS2 and WOx/WS2 heterostructures sandwiched between two printed silver electrodes exhibit an unprecedentedly large and tunable electrical resistance range from 10(2) to 10(8) Ω combined with low programming voltages of 0.1-0.2 V. The bipolar resistive switching, with a concurrent capacitive contribution, is governed by an ultrathin (<3 nm) oxide layer. With strong nonlinearity in switching dynamics, different mechanisms of synaptic plasticity are implemented by applying a sequence of electrical pulses.
RESUMO
The past 18 months have seen an unprecedented approach to vaccine development in the global effort against the COVID-19 pandemic. The process from discovery research, through clinical trials and regulatory approval often takes more than 10 years. However, the critical need to expedite vaccine availability in the pandemic has meant that new approaches to development, manufacturing, and regulation have been required: this has necessitated many stages of product development, clinical trials, and manufacturing to be undertaken in parallel at a global level. Through the development of these innovative products, the world has the best chance of finding individual, or combinations of, vaccines that will provide adequate protection for the world's population. Despite the huge scientific and regulatory achievements and significant investment to accelerate vaccine availability, it is essential that safety measures are not compromised. Here we focus on the post regulatory approval testing by independent laboratories that provides an additional assurance of the safety and quality of a product, with an emphasis on the UK experience through the National Institute for Biological Standards and Control (NIBSC), an expert centre of the UK's Medicines and Healthcare products Regulatory Agency (MHRA).
RESUMO
The general mechanism of chemical sensing is based on molecular recognition linked to different transduction strategies based on electrochemical, optical, gravimetric or thermal effects that can convert the signal to digital information. Electrochemical sensors support accurate, fast, and inexpensive analytical methods with the advantages of being easily embedded and integrated into electronics, and having the greatest potential impact in the areas of healthcare, environmental monitoring (e.g. electronic noses), food packaging and many other applications (E. Bakker and Y. Qin, Anal. Chem., 2006, 78, 3965). Nanoscale electrochemical biosensors offer a new scope and opportunity in analytical chemistry. The reduction in the size of electrochemical biosensors to nanoscale dimensions expands their analytical capability, allowing the exploration of nanoscopic domains, measurements of local concentration profiles, detection in microfluidic systems and in vivo monitoring of neurochemical events by detection of stimulated dopamine release (R. Kennedy, L. Huang, M. Atkinson and P. Dush, Anal. Chem., 1993, 65, 1882). This article reviews both state of art developments in electrochemical nanosensing, and the industrial outlook.
Assuntos
Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Nanoestruturas , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Propriedades de SuperfícieRESUMO
As characterization of glycosylation is required for the licensing of recombinant glycoprotein therapeutics, technique comparability must be assessed. Eleven UK laboratories (seven industrial, two regulatory or government, two academic) participated in an inter-laboratory study to analyze N-glycans present in four mixtures prepared by PNGase F cleavage of commercial glycoproteins: human alpha1-acid glycoprotein (H alpha1), bovine alpha1-acid glycoprotein (B alpha1), bovine pancreatic ribonuclease B (RNaseB), and human serum immunoglobulin G (hIgG). Participants applied their routine glycan mapping methodology using predominantly chromatography and mass spectrometry to identify and quantify components. Data interpretation focused on the relative amounts of different glycan structures present, the degree of sialylation, antennary and the galactosylation profiles, fucosylation and bisecting GlcNAc content, and the number of glycan components identified. All laboratories found high levels of sialylation for H alpha1 and B alpha1 (Z-numbers 271 +/- 24 and 224 +/- 18, respectively), but varying ratios of di-, tri-, and tetra-antennary chains. The Z-score for hIgG glycans had high variability as values obtained from mass spectrometric and chromatographic methods clustered separately. The proportion of the major penta-mannosyl chain from RNaseB was between 29 and 62%. Proportions of fucosylated and bisected GlcNAc chains from hIgG were between 58 and 96% and 9 and 23%, respectively. Mass spectrometric approaches consistently identified more glycan species, especially when both N-glycolylneuraminic acid (Neu5Gc) and N-acetylneuraminic acid (Neu5Ac) were present. These data highlight the need for well-characterized reference standards to support method validation and regulatory guidance on selection of approaches. Pharmacopoeial specifications must acknowledge method variability.
Assuntos
Técnicas de Laboratório Clínico , Glicoproteínas/química , Oligossacarídeos/química , Polissacarídeos/análise , Animais , Bovinos , Cromatografia/métodos , Humanos , Imunoglobulina G/química , Espectrometria de Massas/métodos , Polissacarídeos/químicaRESUMO
A selection of physicochemical and biological assays were investigated for their utility in detecting changes in preparations of Interferon alpha-2a and Interferon alpha-2b (IFN-alpha 2a, IFN-alpha 2b), which had been subjected to stressed conditions, in order to create models of biopharmaceutical products containing product-related impurities. The stress treatments, which included oxidation of methionine residues and storage at elevated temperatures for different periods of time, were designed to induce various degrees of degradation, aggregation or oxidation of the interferon. Biological activity of the stressed preparations was assessed in three different in vitro cell-based bioassay systems: a late-stage anti-proliferative assay and early-stage assays measuring reporter gene activation or endogenous gene expression by quantitative real time Reverse Transcription-Polymerase Chain Reaction (qRT-PCR). Relevant physicochemical methods such as SDS-PAGE, reverse phase (RP) chromatography, size-exclusion chromatography (SEC) and dynamic light scattering (DLS), proved their complementarity in detecting structural changes in the stressed preparations which were reflected by reductions in biological activity.
Assuntos
Bioensaio/métodos , Produtos Biológicos/química , Interferon-alfa/análise , Produtos Biológicos/metabolismo , Proliferação de Células , Cromatografia/métodos , Desenho de Fármacos , Eletroforese em Gel de Poliacrilamida , Humanos , Interferon alfa-2 , Interferon-alfa/metabolismo , Metionina/química , Oxigênio/química , Proteínas Recombinantes , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Manejo de Espécimes , TemperaturaRESUMO
An approach to polymer surface modification using self-assembled layers (SALs) of functional alkoxysilanes has been developed in order to improve the printability of silver nanoparticle inks and enhance adhesion between the metal conducting layer and the flexible polymer substrate. The SALs have been fully characterized by AFM, XPS, and WCA, and the resulting printability, adhesion, and electrical conductivity of the screen-printed metal contacts have been estimated by cross-cut tape test and 4-point probe measurements. It was shown that (3-mercaptopropyl)trimethoxysilane SALs enable significant adhesion improvements for both aqueous- and organic-based silver inks, approaching nearly 100% for PEN and PDMS substrates while exhibiting relatively low sheet resistance up to 0.1 Ω/sq. It was demonstrated that SALs containing functional -SH or -NH2 end groups offer the opportunity to increase the affinity of the polymer substrates to silver inks and thus to achieve efficient patterning of highly conductive structures on flexible and stretchable substrates.
RESUMO
The measurement of protein concentration in an aqueous sample is an important assay in biochemistry research and development labs for applications ranging from enzymatic studies to providing data for biopharmaceutical lot release. Spectrophotometric protein quantitation assays are methods that use UV and visible spectroscopy to rapidly determine the concentration of protein, relative to a standard, or using an assigned extinction coefficient. Methods are described to provide information on how to analyze protein concentration using UV protein spectroscopy measurements, traditional dye-based absorbance measurements; BCA, Lowry, and Bradford assays and the fluorescent dye-based assays; amine derivatization and detergent partition assays. The observation that no single assay dominates the market is due to specific limitations of certain methods that investigators need to consider before selecting the most appropriate assay for their sample. Many of the dye-based assays have unique chemical mechanisms that are prone to interference from chemicals prevalent in many biological buffer preparations. A discussion of which assays are prone to interference and the selection of alternative methods is included.
Assuntos
Bioquímica/métodos , Proteínas/análise , Algoritmos , Aminas/metabolismo , Animais , Bioquímica/instrumentação , Colorimetria/instrumentação , Colorimetria/métodos , Humanos , Indicadores e Reagentes/síntese química , Indicadores e Reagentes/química , Medições Luminescentes/instrumentação , Medições Luminescentes/métodos , Proteínas/química , Quinolinas/química , Quinolinas/farmacologia , Corantes de Rosanilina/química , Corantes de Rosanilina/farmacologia , Espectroscopia por Absorção de Raios X/instrumentação , Espectroscopia por Absorção de Raios X/métodosRESUMO
BACKGROUND: Immunoassays allow the specific detection and quantitation of biological molecules in complex samples at physiologically relevant concentrations. However, there are concerns over the comparability of such techniques when the same assay is performed by different operators or laboratories. An international intercomparison study was performed to assess the uncertainty involved in the estimation of a protein cytokine concentration using a fluorescent ELISA. METHODS: The intercomparison study method was based on a non-competitive sandwich immunoassay with an enhancement step to generate a fluorescent readout. The intercomparison was performed in two phases, with the uncertainty of the instrument determined separately from that of the assay. The 11 laboratories participating in the study represented national metrology institutes or nominated expert laboratories. RESULTS: Participants were asked to determine an undisclosed concentration of interferon using a supplied standard. The mean participant estimate and experimental standard deviation of the mean was 3.54+/-0.22 mg/L, with the spread of data ranging around +/-35% of the mean. The quantitation range of the ELISA and of participants' instruments displayed large variation that contributed to the overall uncertainty. CONCLUSIONS: Identified sources of uncertainty within the ELISA methodology included pipetting, data fitting, model selection and instrument/plate variation.