Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 46: 372-379, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28689955

RESUMO

BACKGROUND: The endovascular technique has been recommended over the past few years to extracranial carotid dissection and pseudoaneurysm with promising results, especially after medical therapy failure. Flow-diverting stents are an alternative for complex cases. These stents have proven to be effective treatment devices for intracranial aneurysms. METHODS: The reference list of Pham's systematic review, published in 2011, and Seward's literature review, published in 2015, was considered, as well as all new articles with eligible features. Search was conducted on specific databases: MEDLINE and Literatura Latino-Americana e do Caribe em Ciências da Saúde. RESULTS: For carotid dissection and pseudoaneurysm, our review yielded 3 published articles including 12 patients. The technical success rate of flow-diverting stent was 100% with no procedural complication described. Mean clinical follow-up was 27.2 months (range 5-48), and in 5 months' angiographic follow-up, all lesions had healed. No new neurological events were reported during the clinical follow-up. CONCLUSIONS: Flow diverter stent use on intracranial and peripheral vascular surgery demonstrates satisfactory initial results, but it is still under investigation. There are very few cases treated till now and the initial results with flow-diverting stents to cervical carotid dissection are promising. In well-selected cases, where simple embolization or conventional stent is not appropriate, this technic may be considered.


Assuntos
Falso Aneurisma/terapia , Dissecção Aórtica/terapia , Doenças das Artérias Carótidas/terapia , Procedimentos Endovasculares/instrumentação , Stents , Adulto , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/fisiopatologia , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/fisiopatologia , Angiografia por Tomografia Computadorizada , Embolização Terapêutica/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fluxo Sanguíneo Regional , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
2.
J Vasc Surg ; 58(6): 1644-1651.e4, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23642917

RESUMO

OBJECTIVE: To elucidate the histologic changes after stent graft oversizing in nonatherosclerotic aortas using an experimental porcine model. We previously reported that the diameter and angulation of the aorta in this model are similar to those in young individuals who undergo stent graft repair for blunt aortic injuries. The lack of commercially available stent grafts specific for repairing blunt aortic injuries, particularly for small and angulated aortas, may be related to the high rate of endograft complications in this population. METHODS: Twenty-five pigs were randomized into one control group (without stent graft implantation) and four oversized groups (A: 10%-19%, B: 20%-29%, C: 30%-39%, and D: >40%). Three circumferential fragments were collected from the aorta for histologic and immunohistochemical studies. Morphometric analyzes were performed using an inflow system and image analysis software (Quantimet 500; Leica Cambridge Ltd, Cambridge, UK). RESULTS: Collagen expression in the aortic wall was not significantly different among the five groups (P = .5604). There were significantly fewer muscle fibers in the aortic wall in the oversized groups compared with the control group (P = .000198). The proportion of elastic fibers in the aortic wall was significantly smaller in the oversized groups compared with the control group (P = .0000001). Immunohistochemical analysis showed that α-actin expression in the aortic wall was significantly decreased in the oversized groups compared with the control group (P = .002031). There were no significant differences in either the number of muscle fibers or α-actin expression among the four oversized groups. CONCLUSIONS: Histologic and immunohistochemical studies confirmed the structural disarrangement of the aortic wall after insertion of an endoprosthesis, including reduced number of muscle and elastic fibers.


Assuntos
Aorta Torácica/patologia , Prótese Vascular , Procedimentos Endovasculares/métodos , Stents , Lesões do Sistema Vascular/cirurgia , Animais , Aorta Torácica/lesões , Aorta Torácica/cirurgia , Aortografia , Modelos Animais de Doenças , Imuno-Histoquímica , Desenho de Prótese , Estresse Mecânico , Suínos , Tomografia Computadorizada por Raios X , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA