Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 50(11): 3225-3234, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37300572

RESUMO

PURPOSE: Dosimetry is rarely performed for the treatment of differentiated thyroid cancer patients with Na[131I]I (radioiodine), and information regarding absorbed doses delivered is limited. Collection of dosimetry data in a multi-centre setting requires standardised quantitative imaging and dosimetry. A multi-national, multi-centre clinical study was performed to assess absorbed doses delivered to normal organs for differentiated thyroid cancer patients treated with Na[131I]I. METHODS: Patients were enrolled in four centres and administered fixed activities of 1.1 or 3.7 GBq of Na[131I]I using rhTSH stimulation or under thyroid hormone withdrawal according to local protocols. Patients were imaged using SPECT(/CT) at variable imaging time-points following standardised acquisition and reconstruction protocols. Whole-body retention data were collected. Dosimetry for normal organs was performed at two dosimetry centres and results collated. RESULTS: One hundred and five patients were recruited. Median absorbed doses per unit administered activity of 0.44, 0.14, 0.05 and 0.16 mGy/MBq were determined for the salivary glands of patients treated at centre 1, 2, 3 and 4, respectively. Median whole-body absorbed doses for 1.1 and 3.7 GBq were 0.05 Gy and 0.16 Gy, respectively. Median whole-body absorbed doses per unit administered activity of 0.04, 0.05, 0.04 and 0.04 mGy/MBq were calculated for centre 1, 2, 3 and 4, respectively. CONCLUSIONS: A wide range of normal organ doses were observed for differentiated thyroid cancer patients treated with Na[131I]I, highlighting the necessity for individualised dosimetry. The results show that data may be collated from multiple centres if minimum standards for the acquisition and dosimetry protocols can be achieved.


Assuntos
Radioisótopos do Iodo , Neoplasias da Glândula Tireoide , Humanos , Radioisótopos do Iodo/uso terapêutico , Radiometria/métodos , Neoplasias da Glândula Tireoide/radioterapia , Neoplasias da Glândula Tireoide/tratamento farmacológico , Glândulas Salivares
2.
Hell J Nucl Med ; 26 Suppl: 14, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37658553

RESUMO

INTRODUCTION: Clinical dosimetry in nuclear medicine is developing fast, with an increasing number of procedures performed for a variety of therapeutic applications. In that context, the advent of CE-marked commercial clinical dosimetry software is a positive signal, as they should, in principle, optimize the workflow and increase robustness. However, they pose the problem of the evaluation of their performances, in terms of accuracy but also ease of use (user-friendliness). AIM: The aim of this presentation is to discuss the various steps required for the evaluation of clinical dosimetry procedures in general, and dosimetry software in particular. MATERIALS AND METHODS: The clinical dosimetry workflow (CDW) is the suite of steps that lead from calibration procedures to the final reporting of the clinical dosimetry procedure. The study of the CDW implemented in various software shows a age variability in the implementation of the steps that constitute the CDW, and the order of their implementation. This can be accepted, however it raises the issue of comparing software that, basically, do not do the same thing, or do things in a different order. RESULTS AND DISCUSSION: The various steps that compose the CDW have to be studied (benchmarked) using specific tools: If assessing calibrations/reconstructions can be made using phantoms filled with radioactive sources, rigid objects are not adapted to the evaluation of registration procedures. Computing anthropomorphic models can be used to verify absorbed dose calculation algorithms (for example using Monte Carlo radiation transport modelling as the gold standard). As can be seen, a range of tools of different type (test objects, models, patient data) must be used - and sometimes developed - to evaluate each step of the CDW. Finally, the end-to-end process must be benchmarked on "real" clinical data, but the price to pay is that the ground truth is not known, thereby limiting these approaches to precision rather than accuracy. CONCLUSION: Nuclear medicine dosimetry quality assurance (QA) is in its infancy. However, procedures already applied in external beam radiotherapy may be easily transposed to nuclear medicine, and it will not take decades until nuclear medicine benefits from sound, reproducible procedures that will increase the robustness of clinical dosimetry procedures.


Assuntos
Medicina Nuclear , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radiometria/métodos , Software , Algoritmos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica
3.
BMC Cancer ; 22(1): 1346, 2022 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36550428

RESUMO

BACKGROUND: Although neuroendocrine tumors (NET) are classed as rare, they have a high prevalence and their incidence is increasing. Effective treatment with lutetium 17-[177Lu]Lu-oxodotreotide (Lutathera®) is possible in patients with well-differentiated NET, improving progression-free survival (PFS), overall survival (OS), and quality of life (QoL). However, progression does occur. Retreatment with additional Lutathera® cycles is an option to extend PFS and OS. Two retreatment cycles are usually proposed. We aim to compare four versus two Lutathera® retreatment cycles in patients with new progression of a well-differentiated intestinal NET. METHODS: This will be a multicenter, randomized, controlled, open-label, phase II study in France (ReLUTH). The aim is to evaluate the efficacy of retreatment with Lutathera® in patients with progressive intestinal NET (determined by somatostatin-receptor positive imaging) after previous treatment with two cycles of Lutathera®. Before randomization, all patients will have already received two Lutathera® retreatment cycles (7.4 GBq infusion each, 8 weeks apart). A total of 146 patients will be randomized (1:1) to two additional cycles of Lutathera® (7.4 GBq infusion each, separated by 8 weeks) or to no treatment (active surveillance). PRIMARY OBJECTIVE: efficacy of two additional Lutathera® retreatment cycles compared to active surveillance over 6 months. PRIMARY ENDPOINT: disease control rate at 6 months from randomization (defined as Complete Response, Partial Response, and Stable Disease in the Response Evaluation Criteria In Solid Tumours) with an evaluation every 2 months. A secondary objective will be the safety, as well as the PFS, OS, and QoL. It is expected that the efficacy of retreatment will increase after two additional Lutathera® cycles, with no increased safety concerns. DISCUSSION: Our prospective, randomized controlled study may lead to new recommendations for the use of Lutathera® in patients with intestinal progressive NET, and should confirm that four cycles will be more effective than two, with limited adverse impact on safety. Four Lutathera® treatment cycles have the potential to prolong life and improve quality of life in patients. TRIAL REGISTRATION: ClinicalTrials.gov: NCT04954820.


Assuntos
Tumores Neuroendócrinos , Compostos Organometálicos , Humanos , Tumores Neuroendócrinos/patologia , Qualidade de Vida , Estudos Prospectivos , Octreotida , Compostos Organometálicos/efeitos adversos , Retratamento
4.
Hell J Nucl Med ; 24(2): 165-166, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34352056

RESUMO

Lutetium-177 (177Lu)-based post-therapeutic imaging allows visualization of treated lesions andabsorbed dose measurement. There is an increasing number of cadmium-zinc-telluride (CZT) gamma-cameras in nuclear medicine departments but until now these devices were not adapted to the medium-energy emission of 177Lu photons. We present here in the first reported images acquired with a new collimator designed for CZT gamma-camera compared to a conventional sodium iodide (NaI) (Tl) gamma-camera. Post-therapeutic 177Lu-DOTATATE imaging on a CZT device with a medium energy high resolution (MEHRS)-collimator are promising and support the widespread of both 177Lu-based peptide-receptor radionuclide therapy (PRRT) and CZT gamma-cameras.


Assuntos
Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Cádmio , Humanos , Tomografia por Emissão de Pósitrons , Cintilografia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Zinco
5.
Radiat Environ Biophys ; 59(1): 29-62, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31863162

RESUMO

At the tissue level, energy deposition in cells is determined by the microdistribution of alpha-emitting radionuclides in relation to sensitive target cells. Furthermore, the highly localized energy deposition of alpha particle tracks and the limited range of alpha particles in tissue produce a highly inhomogeneous energy deposition in traversed cell nuclei. Thus, energy deposition in cell nuclei in a given tissue is characterized by the probability of alpha particle hits and, in the case of a hit, by the energy deposited there. In classical microdosimetry, the randomness of energy deposition in cellular sites is described by a stochastic quantity, the specific energy, which approximates the macroscopic dose for a sufficiently large number of energy deposition events. Typical examples of the alpha-emitting radionuclides in internal microdosimetry are radon progeny and plutonium in the lungs, plutonium and americium in bones, and radium in targeted radionuclide therapy. Several microdosimetric approaches have been proposed to relate specific energy distributions to radiobiological effects, such as hit-related concepts, LET and track length-based models, effect-specific interpretations of specific energy distributions, such as the dual radiation action theory or the hit-size effectiveness function, and finally track structure models. Since microdosimetry characterizes only the initial step of energy deposition, microdosimetric concepts are most successful in exposure situations where biological effects are dominated by energy deposition, but not by subsequently operating biological mechanisms. Indeed, the simulation of the combined action of physical and biological factors may eventually require the application of track structure models at the nanometer scale.


Assuntos
Partículas alfa , Radioisótopos , Radiometria/métodos , Animais , Osso e Ossos , Humanos , Pulmão , Radioisótopos/uso terapêutico
6.
J Appl Clin Med Phys ; 21(8): 208-215, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32573908

RESUMO

PURPOSE: To assess the accuracy of volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) when treating moving targets (such as lung or liver lesions), focusing on the impact of the interplay effect in the event of complex breathing motion and when a gating window is used. METHODS: A dedicated programmable motion platform was implemented. This platform can carry large quality assurance (QA) phantoms and achieve complex three-dimensional (3D) motion. Volumetric modulated arc therapy SBRT plans were delivered with TrueBeam linac to this moving setup and the measured dose was compared to the computed one. Several parameters were assessed such as breathing period, dose rate, dose prescription, shape of the breathing pattern, the use of a planning target volume (PTV) margin, and the use of a gating window. RESULTS: Loss of dose coverage (D95%) was acceptable in most situations. The doses received by 95% of the CTV, D95% ( C T V m ) ranged from 94 to 101% (mean 98%) and the doses received by 2% of the CTV D2% ( C T V m ) ranged from 94% to 110% of the prescribed dose. A visible interplay effect was observed when no margin was used or when the number of breathing cycles during the treatment delivery was lower than 20. CONCLUSIONS: In our clinical context, treating lung and liver lesions using VMAT SBRT is reasonable. The interplay effect was moderated and acceptable in all simulated situations.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
8.
J Appl Clin Med Phys ; 16(6): 164­176, 2015 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699568

RESUMO

Intensity-modulated radiation therapy (IMRT) for total body irradiation (TBI) is practiced in several centers using the TomoTherapy System. In this context the planning target volume (PTV) is the entire body including the skin. A safety margin in the air surrounding the body should be added to take into account setup errors. But using inverse planning, over-fluence peak could be generated in the skin region to insure dose homogeneity. This work proposes to study the performance of the use of a virtual bolus (VB). A VB is a material placed on the skin surface during planning, but absent for the real treatment. The optimal VB that compensates large setup errors without introducing a high-dose increase or hot spots for small setup errors was determined. For two cylindrical phantoms, 20VBs with different densities, thicknesses or designs were tested. Dose coverage of the PTV (V95%) in the presence of simulated setup errors was computed to assess the VB performance. A measure of the dose increase in the phantom center due to the absence of the VB during treatment was also achieved. Finally, the fluence peak at the phantom edge was measured in complete buildup conditions using a large phantom and a detector matrix. Using these VBs, simulated setup errors were compensated to a minimum value of 2.6 and 2.1 cm for small and large phantom, respectively (and only 1.2 and 1.7 cm with no VB). An optimal double-layer VB was found with a density of 0.4 kg.m(-3) and a total thickness of 8mm; an inner layer of 5 mm was declared as the target for the treatment planning system and an additional layer of 3 mm was added to avoid the over-fluence peak. Using this VB, setup errors were compensated up to 2.9 cm. The dose increase was measured to be only +1.5% at the phantom center and over-fluence peak was strongly decreased.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Irradiação Corporal Total/métodos , Simulação por Computador , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Interface Usuário-Computador
9.
Eur J Nucl Med Mol Imaging ; 41(10): 1976-88, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24915892

RESUMO

Molecular radiotherapy (MRT) has demonstrated unique therapeutic advantages in the treatment of an increasing number of cancers. As with other treatment modalities, there is related toxicity to a number of organs at risk. Despite the large number of clinical trials over the past several decades, considerable uncertainties still remain regarding the optimization of this therapeutic approach and one of the vital issues to be answered is whether an absorbed radiation dose-response exists that could be used to guide personalized treatment. There are only limited and sporadic data investigating MRT dosimetry. The determination of dose-effect relationships for MRT has yet to be the explicit aim of a clinical trial. The aim of this article was to collate and discuss the available evidence for an absorbed radiation dose-effect relationships in MRT through a review of published data. Based on a PubMed search, 92 papers were found. Out of 79 studies investigating dosimetry, an absorbed dose-effect correlation was found in 48. The application of radiobiological modelling to clinical data is of increasing importance and the limited published data on absorbed dose-effect relationships based on these models are also reviewed. Based on National Cancer Institute guideline definition, the studies had a moderate or low rate of clinical relevance due to the limited number of studies investigating overall survival and absorbed dose. Nevertheless, the evidence strongly implies a correlation between the absorbed doses delivered and the response and toxicity, indicating that dosimetry-based personalized treatments would improve outcome and increase survival.


Assuntos
Medicina Baseada em Evidências/métodos , Neoplasias/diagnóstico por imagem , Radioterapia/métodos , Humanos , Neoplasias/radioterapia , Cintilografia , Dosagem Radioterapêutica
10.
Phys Med ; 120: 103328, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38498956

RESUMO

The EFOMP Special Interest Group for Radionuclide Internal Dosimetry (SIG_FRID) organised its first scientific meeting, the Symposium on Molecular Radiotherapy Dosimetry, in Athens on November 9th-11th 2023. The Symposium was hosted by the Hellenic Association of Medical Physicists and the National and Kapodistrian University of Athens. This meeting gathered more than 180 scientists from 28 countries. Scientific, clinical and regulatory aspects were addressed by 8 invited experts. Two continuous professional development sessions were organised. A special round table gathering medical physics experts, physicians regulatory authority experts and patient representatives addressed the possibilities to increase clinical dosimetry dissemination. The event was supported by companies and a specific industry session allowed sponsors to present their products, innovations and future perspective in this field.


Assuntos
Radiometria , Humanos
11.
J Nucl Med ; 65(10): 1564-1570, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39266288

RESUMO

Single-domain antibodies (sdAbs) demonstrate favorable pharmacokinetic profiles for molecular imaging applications. However, their renal excretion and retention are obstacles for applications in targeted radionuclide therapy (TRT). Methods: Using a click-chemistry-based pretargeting approach, we aimed to reduce kidney retention of a fibroblast activation protein α (FAP)-targeted sdAb, 4AH29, for 177Lu-TRT. Key pretargeting parameters (sdAb-injected mass and lag time) were optimized in healthy mice and U87MG (FAP+) xenografts. A TRT study in a pancreatic ductal adenocarcinoma (PDAC) patient-derived xenograft (PDX) model was performed as a pilot study for sdAb-based pretargeting applications. Results: Modification of 4AH29 with trans-cyclooctene (TCO) moieties did not modify the sdAb pharmacokinetic profile. A 200-µg injected mass of 4AH29-TCO and an 8-h lag time for the injection of [177Lu]Lu-DOTA-PEG7-tetrazine resulted in the highest kidney therapeutic index (2.0 ± 0.4), which was 5-fold higher than that of [177Lu]Lu-DOTA-4AH29 (0.4 ± 0.1). FAP expression in the tumor microenvironment was validated in a PDAC PDX model with both immunohistochemistry and PET/CT imaging. Mice treated with the pretargeting high-activity approach (4AH29-TCO + [177Lu]Lu-DOTA-PEG7-tetrazine; 3 × 88 MBq, 1 injection per week for 3 wk) demonstrated prolonged survival compared with the vehicle control and conventionally treated ([177Lu]Lu-DOTA-4AH29; 3 × 37 MBq, 1 injection per week for 3 wk) mice. Mesangial expansion was reported in 7 of 10 mice in the conventional cohort, suggesting treatment-related kidney morphologic changes, but was not observed in the pretargeting cohort. Conclusion: This study validates pretargeting to mitigate sdAbs' kidney retention with no observation of morphologic changes on therapy regimen at early time points. Clinical translation of click-chemistry-based pre-TRT is warranted on the basis of its ability to alleviate toxicities related to biovectors' intrinsic pharmacokinetic profiles. The absence of representative animal models with extensive stroma and high FAP expression on cancer-associated fibroblasts led to a low mean tumor-absorbed dose even with high injected activity and consequently to modest survival benefit in this PDAC PDX.


Assuntos
Compostos Radiofarmacêuticos , Anticorpos de Domínio Único , Animais , Camundongos , Compostos Radiofarmacêuticos/uso terapêutico , Compostos Radiofarmacêuticos/farmacocinética , Humanos , Linhagem Celular Tumoral , Anticorpos de Domínio Único/uso terapêutico , Distribuição Tecidual , Feminino , Endopeptidases , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/diagnóstico por imagem , Carcinoma Ductal Pancreático/radioterapia , Carcinoma Ductal Pancreático/diagnóstico por imagem , Rim/diagnóstico por imagem , Proteínas de Membrana
12.
Med Phys ; 51(1): 522-532, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37712869

RESUMO

BACKGROUND: Radiopharmaceutical therapy (RPT) is an increasingly adopted modality for treating cancer. There is evidence that the optimization of the treatment based on dosimetry can improve outcomes. However, standardization of the clinical dosimetry workflow still represents a major effort. Among the many sources of variability, the impact of using different Dose Voxel Kernels (DVKs) to generate absorbed dose (AD) maps by convolution with the time-integrated activity (TIA) distribution has not been systematically investigated. PURPOSE: This study aims to compare DVKs and assess the differences in the ADs when convolving the same TIA map with different DVKs. METHODS: DVKs of 3 × 3 × 3 mm3 sampling-nine for 177 Lu, nine for 90 Y-were selected from those most used in commercial/free software or presented in prior publications. For each voxel within a 11 × 11 × 11 matrix, the coefficient of variation (CoV) and the percentage difference between maximum and minimum values (% maximum difference) were calculated. The total absorbed dose per decay (SUM), calculated as the sum of all the voxel values in each kernel, was also compared. Publicly available quantitative SPECT images for two patients treated with 177 Lu-DOTATATE and PET images for two patients treated with 90 Y-microspheres were used, including organs at risk (177 Lu: kidneys; 90 Y: liver and healthy liver) and tumors' segmentations. For each patient, the mean AD to the volumes of interest (VOIs) was calculated using the different DVKs, the same TIA map and the same software tool for dose convolution, thereby focusing on the DVK impact. For each VOI, the % maximum difference of the mean AD between maximum and minimum values was computed. RESULTS: The CoV (% maximum difference) in voxels of normalized coordinates [0,0,0], [0,1,0], and [0,1,1] were 5%(21%), 9%(35%), and 10%(46%) for the 177 Lu DVKs. For the case of 90 Y, these values were 2%(9%), 4%(14%), and 4%(16%). The CoV (% maximum difference) for SUM was 9%(33%) for 177 Lu, and 4%(15%) for 90 Y. The variability of the mean tumor and organ AD was up to 19% and 15% in 177 Lu-DOTATATE and 90 Y-microspheres patients, respectively. CONCLUSIONS: This study showed a considerable AD variability due exclusively to the use of different DVKs. A concerted effort by the scientific community would contribute to decrease these discrepancies, strengthening the consistency of AD calculation in RPT.


Assuntos
Radiometria , Compostos Radiofarmacêuticos , Humanos , Fígado , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Software
13.
J Nucl Med ; 65(6): 923-930, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38637144

RESUMO

[177Lu]Lu-DOTATATE has been approved for progressive and inoperable gastroenteropancreatic neuroendocrine tumors (GEP-NETs) that overexpress somatostatin receptors. The absorbed doses by limiting organs and tumors can be quantified by serial postinfusion scintigraphy measurements of the γ-emissions from 177Lu. The objective of this work was to explore how postinfusion [177Lu]Lu-DOTATATE dosimetry could influence clinical management by predicting treatment efficacy (tumor shrinkage and survival) and toxicity. Methods: Patients with GEP-NETs treated with [177Lu]Lu-DOTATATE between 2016 and 2022 and who underwent dosimetry were included. Absorbed doses were calculated for healthy organs (liver, kidneys, bone marrow, and spleen) and tumors using PLANET Dose and the local energy deposition method based on serial posttreatment SPECT/CT. Up to 5 lesions per site were selected and measured on images collected at baseline and 3 mo after treatment end (measurement masked to the somatostatin receptor imaging uptake). For toxicity assessment, laboratory parameters were regularly monitored. Clinical data, including time to death or progression, were collected from the patients' health records. Correlations between absorbed doses by organs and toxicity and between absorbed doses by lesions and tumor volume variation were studied using regression models. Results: In total, 35 dosimetric studies were performed in patients with mostly grade 2 (77%) tumors and metastases in liver (89%), lymph nodes (77%), and bone (34%), and 146 lesions were analyzed: 1-9 lesions per patient, mostly liver metastases (65%) and lymph nodes (25%). The median total absorbed dose by tumors was 94.4 Gy. The absorbed doses by tumors significantly decreased between cycles. The absorbed dose by tumors was significantly associated with tumor volume variation (P < 0.001) 3 mo after treatment end, and it was a significant prognostic factor for survival. Toxicity analysis showed a correlation between the decrease of hematologic parameters such as lymphocytes or platelet concentrations and the absorbed doses by the spleen or bone marrow. The mean absorbed dose by the kidneys was not correlated with nephrotoxicity during the studied period. Conclusion: In patients treated with [177Lu]Lu-DOTATATE for GEP-NETs, tumor and healthy organ dosimetry can predict survival and toxicities, thus influencing clinical management.


Assuntos
Relação Dose-Resposta à Radiação , Neoplasias Intestinais , Tumores Neuroendócrinos , Octreotida , Compostos Organometálicos , Neoplasias Pancreáticas , Medicina de Precisão , Radiometria , Neoplasias Gástricas , Humanos , Tumores Neuroendócrinos/radioterapia , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Octreotida/análogos & derivados , Octreotida/uso terapêutico , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/diagnóstico por imagem , Masculino , Compostos Organometálicos/uso terapêutico , Feminino , Neoplasias Gástricas/radioterapia , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/metabolismo , Neoplasias Gástricas/patologia , Pessoa de Meia-Idade , Idoso , Neoplasias Intestinais/radioterapia , Neoplasias Intestinais/diagnóstico por imagem , Neoplasias Intestinais/patologia , Adulto , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estudos Retrospectivos
14.
Phys Med ; 117: 103196, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38104033

RESUMO

PURPOSE: The use of molecular radiotherapy (MRT) has been rapidly evolving over the last years. The aim of this study was to assess the current implementation of dosimetry for MRTs in Europe. METHODS: A web-based questionnaire was open for treating centres between April and June 2022, and focused on 2020-2022. Questions addressed the application of 16 different MRTs, the availability and involvement of medical physicists, software used, quality assurance, as well as the target regions for dosimetry, whether treatment planning and/or verification were performed, and the dosimetric methods used. RESULTS: A total of 173 responses suitable for analysis was received from centres performing MRT, geographically distributed over 27 European countries. Of these, 146 centres (84 %) indicated to perform some form of dosimetry, and 97 % of these centres had a medical physicist available and almost always involved in dosimetry. The most common MRTs were 131I-based treatments for thyroid diseases and thyroid cancer, and [223Ra]RaCl2 for bone metastases. The implementation of dosimetry varied widely between therapies, from almost all centres performing dosimetry-based planning for microsphere treatments to none for some of the less common treatments (like 32P sodium-phosphate for myeloproliferative disease and [89Sr]SrCl2 for bone metastases). CONCLUSIONS: Over the last years, implementation of dosimetry, both for pre-therapeutic treatment planning and post-therapy absorbed dose verification, increased for several treatments, especially for microsphere treatments. For other treatments that have moved from research to clinical routine, the use of dosimetry decreased in recent years. However, there are still large differences both across and within countries.


Assuntos
Radiometria , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Europa (Continente)
15.
J Nucl Med ; 65(1): 125-131, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-37884334

RESUMO

Implementation of radiopharmaceutical therapy dosimetry varies depending on the clinical application, dosimetry protocol, software, and ultimately the operator. Assessing clinical dosimetry accuracy and precision is therefore a challenging task. This work emphasizes some pitfalls encountered during a structured analysis, performed on a single-patient dataset consisting of SPECT/CT images by various participants using a standard protocol and clinically approved commercial software. Methods: The clinical dataset consisted of the dosimetric study of a patient administered with [177Lu]Lu-DOTATATE at Tygerberg Hospital, South Africa, as a part of International Atomic Energy Agency-coordinated research project E23005. SPECT/CT images were acquired at 5 time points postinjection. Patient and calibration images were reconstructed on a workstation, and a calibration factor of 122.6 Bq/count was derived independently and provided to the participants. A standard dosimetric protocol was defined, and PLANETDose (version 3.1.1) software was installed at 9 centers to perform the dosimetry of 3 treatment cycles. The protocol included rigid image registration, segmentation (semimanual for organs, activity threshold for tumors), and dose voxel kernel convolution of activity followed by absorbed dose (AD) rate integration to obtain the ADs. Iterations of the protocol were performed by participants individually and within collective training, the results of which were analyzed for dosimetric variability, as well as for quality assurance and error analysis. Intermediary checkpoints were developed to understand possible sources of variation and to differentiate user error from legitimate user variability. Results: Initial dosimetric results for organs (liver and kidneys) and lesions showed considerable interoperator variability. Not only was the generation of intermediate checkpoints such as total counts, volumes, and activity required, but also activity-to-count ratio, activity concentration, and AD rate-to-activity concentration ratio to determine the source of variability. Conclusion: When the same patient dataset was analyzed using the same dosimetry procedure and software, significant disparities were observed in the results despite multiple sessions of training and feedback. Variations due to human error could be minimized or avoided by performing intensive training sessions, establishing intermediate checkpoints, conducting sanity checks, and cross-validating results across physicists or with standardized datasets. This finding promotes the development of quality assurance in clinical dosimetry.


Assuntos
Neoplasias , Compostos Radiofarmacêuticos , Humanos , Compostos Radiofarmacêuticos/uso terapêutico , Radiometria/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Fígado
16.
Phys Med ; 116: 103166, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37926641

RESUMO

The European Council Directive 2013/59/Euratom (BSS Directive) includes optimisation of treatment with radiotherapeutic procedures based on patient dosimetry and verification of the absorbed doses delivered. The present policy statement summarises aspects of three directives relating to the therapeutic use of radiopharmaceuticals and medical devices, and outlines the steps needed for implementation of patient dosimetry for radioactive drugs. To support the transition from administrations of fixed activities to personalised treatments based on patient-specific dosimetry, EFOMP presents a number of recommendations including: increased networking between centres and disciplines to support data collection and development of codes-of-practice; resourcing to support an infrastructure that permits routine patient dosimetry; research funding to support investigation into individualised treatments; inter-disciplinary training and education programmes; and support for investigator led clinical trials. Close collaborations between the medical physicist and responsible practitioner are encouraged to develop a similar pathway as is routine for external beam radiotherapy and brachytherapy. EFOMP's policy is to promote the roles and responsibilities of medical physics throughout Europe in the development of molecular radiotherapy to ensure patient benefit. As the BSS directive is adopted throughout Europe, unprecedented opportunities arise to develop informed treatments that will mitigate the risks of under- or over-treatments.


Assuntos
Medicina Nuclear , Humanos , Radiometria , Políticas , Europa (Continente)
17.
Tumour Biol ; 33(3): 679-88, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22389160

RESUMO

Syndecan-1 (CD138), a heparan sulfate proteoglycan, is constantly expressed on tumor cells in multiple myeloma (MM). This surface antigen is an attractive candidate for targeted therapy, especially radioimmunotherapy (RAIT). We report preliminary biodistribution and dosimetry results obtained in refractory MM patients in a phase I/II RAIT study using iodine-131-labeled anti-CD138 (B-B4) monoclonal antibody (mAb). Four patients with progressive disease were enrolled after three lines of therapy. They received 370 MBq (20 mg/m(2)) of (131)I-B-B4 for the dosimetry study. Each patient underwent a whole body (WB) CT and four WB emission scans at days D0, D1, and D3-4. Images were corrected for attenuation and scatter to assess doses absorbed by organs and bone marrow (BM). Blood and urine samples were additionally collected. Dosimetry was conducted using the MIRD method. Images obtained 1 h after (131)I-B-B4 injection showed high BM and liver uptake without kidney uptake. The BM uptake confirmed BM involvement as detected by pre-inclusion FDG PET/CT. Absorbed doses were calculated at 2.03 ± 0.3 mGy/MBq for the liver, 1.10 ± 0.9 mGy/MBq for the kidneys, and 0.52 ± 0.20 mGy/MBq for the BM. Grade III thrombocytopenia was documented in two cases (highest BM-absorbed doses), and no grade IV hematological toxicity was observed. Therefore, autologous stem cells were not infused. One patient out of four experienced partial response, with 60% reduction of M-spike on serum electrophoresis, and total relief of pain, lasting for 1 year. This patient was able to go back to work. In this proof of concept study based on dosimetry, we show that MM RAIT is feasible using the anti-CD138 antibody. It would be of great interest to perform a RAIT phase I/II trial with a humanized anti-CD138 mAb with increased doses and systematic autologous stem cell infusions to overcome hematological toxicity and achieve efficacy.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Imunoconjugados/uso terapêutico , Mieloma Múltiplo/radioterapia , Radioimunoterapia , Sindecana-1/imunologia , Anticorpos Monoclonais/farmacologia , Feminino , Humanos , Imunoconjugados/farmacologia , Radioisótopos do Iodo/uso terapêutico , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Radiometria , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Nucl Med Biol ; 104-105: 53-64, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34922279

RESUMO

Targeted radionuclide therapy (TRT) is used to treat disseminated or metastatic tumours in which conventional external beam radiotherapy (EBRT) would have unacceptable side effects. Unlike EBRT, TRT delivers low doses at a continuous low dose rate. In EBRT, the effect increases progressively with the dose rate, and biological effects (tumour control and normal tissue damage) are related to the dose according to a sigmoid curve model. This model is part of the so-called quantitative radiobiology that is mostly based on the target cell theory, according to which cell death is due to (lethal) radiation hits to vital cellular targets. This model was developed for EBRT, but was adapted to low dose-rate situations by including a parameter that reflects the time needed to repair tissue damage. However, a growing body of evidence indicates that the model should take into account also the biological effects, which are due to intercellular communications (bystander effects) and amplify the effects of radiation, as well as the immune system. Moreover, extranuclear targets must be considered, although induced intracellular and intercellular signalling pathways may ultimately result in DNA damage. It is likely that bystander effects and immune response always contribute to the overall response to TRT at different levels, and that dose and dose rate are key parameters in controlling their real contribution. We hypothesize that the dose rate is the key determinant in the balance between the physical and DNA-centred response on one side, and the biological response that integrates all subcellular compartments and intercellular signalling pathways on the other side.


Assuntos
Neoplasias , Radiobiologia , Dano ao DNA , Humanos , Neoplasias/radioterapia , Radioisótopos/uso terapêutico , Transdução de Sinais
19.
Phys Med ; 96: 101-113, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35276403

RESUMO

PURPOSE: Monte Carlo modelling of SPECT imaging in Molecular Radiotherapy can improve activity quantification. Until now, SPECT modelling with GATE only considered circular orbit (CO) acquisitions. This cannot reproduce auto-contour acquisitions, where the detector head moves close to the patient to improve image resolution. The aim of this work is to develop and validate an auto-contouring step-and-shoot acquisition mode for GATE SPECT modelling. METHODS: 177Lu and 131I SPECT experimental acquisitions performed on a Siemens Symbia T2 and GE Discovery 670 gamma camera, respectively, were modelled. SPECT projections were obtained for a cylindrical Jaszczak phantom and a lung and spine phantom. Detector head parameters (radial positions and acquisition angles) were extracted from the experimental projections to model the non-circular orbit (NCO) detector motion. The gamma camera model was validated against the experimental projections obtained with the cylindrical Jaszczak (177Lu) and lung and spine phantom (131I). Then, 177Lu and 131I CO and NCO SPECT projections were simulated to validate the impact of explicit NCO modelling on simulated projections. RESULTS: Experimental and simulated SPECT images were compared using the gamma index, and were in good agreement with gamma index passing rate (GIPR) and gammaavg of 96.27%, 0.242 (177Lu) and 92.89%, 0.36 (131I). Then, simulated 177Lu and 131I CO and NCO SPECT projections were compared. The GIPR, gammaavg between the two gamma camera motions was 99.85%, 0.108 for 177Lu and 75.58%, 0.6 for 131I. CONCLUSION: This work thereby justifies the need for auto-contouring modelling for isotopes with high septal penetration.


Assuntos
Radioisótopos do Iodo , Tomografia Computadorizada de Emissão de Fóton Único , Câmaras gama , Humanos , Radioisótopos do Iodo/uso terapêutico , Método de Monte Carlo , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/métodos
20.
EJNMMI Radiopharm Chem ; 7(1): 18, 2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35852679

RESUMO

BACKGROUND: The development of radiopharmaceuticals requires extensive evaluation before they can be applied in a diagnostic or therapeutic setting in Nuclear Medicine. Chemical, radiochemical, and pharmaceutical parameters must be established and verified to ensure the quality of these novel products. MAIN BODY: To provide supportive evidence for the expected human in vivo behaviour, particularly related to safety and efficacy, additional tests, often referred to as "non-clinical" or "preclinical" are mandatory. This document is an outcome of a Technical Meeting of the International Atomic Energy Agency. It summarises the considerations necessary for non-clinical studies to accommodate the regulatory requirements for clinical translation of radiopharmaceuticals. These considerations include non-clinical pharmacology, radiation exposure and effects, toxicological studies, pharmacokinetic modelling, and imaging studies. Additionally, standardisation of different specific clinical applications is discussed. CONCLUSION: This document is intended as a guide for radiopharmaceutical scientists, Nuclear Medicine specialists, and regulatory professionals to bring innovative diagnostic and therapeutic radiopharmaceuticals into the clinical evaluation process in a safe and effective way.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA