Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Emerg Radiol ; 31(1): 73-82, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38224366

RESUMO

PURPOSE: Acute chest syndrome (ACS) is secondary to occlusion of the pulmonary vasculature and a potentially life-threatening complication of sickle cell disease (SCD). Dual-energy CT (DECT) iodine perfusion map reconstructions can provide a method to visualize and quantify the extent of pulmonary microthrombi. METHODS: A total of 102 patients with sickle cell disease who underwent DECT CTPA with perfusion were retrospectively identified. The presence or absence of airspace opacities, segmental perfusion defects, and acute or chronic pulmonary emboli was noted. The number of segmental perfusion defects between patients with and without acute chest syndrome was compared. Sub-analyses were performed to investigate robustness. RESULTS: Of the 102 patients, 68 were clinically determined to not have ACS and 34 were determined to have ACS by clinical criteria. Of the patients with ACS, 82.4% were found to have perfusion defects with a median of 2 perfusion defects per patient. The presence of any or new perfusion defects was significantly associated with the diagnosis of ACS (P = 0.005 and < 0.001, respectively). Excluding patients with pulmonary embolism, 79% of patients with ACS had old or new perfusion defects, and the specificity for new perfusion defects was 87%, higher than consolidation/ground glass opacities (80%). CONCLUSION: DECT iodine map has the capability to depict microthrombi as perfusion defects. The presence of segmental perfusion defects on dual-energy CT maps was found to be associated with ACS with potential for improved specificity and reclassification.


Assuntos
Síndrome Torácica Aguda , Anemia Falciforme , Iodo , Embolia Pulmonar , Humanos , Síndrome Torácica Aguda/diagnóstico por imagem , Estudos Retrospectivos , Angiografia/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Pulmão , Embolia Pulmonar/diagnóstico por imagem , Anemia Falciforme/complicações , Anemia Falciforme/diagnóstico por imagem , Perfusão
2.
Pol J Radiol ; 89: e63-e69, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38371894

RESUMO

Purpose: Computed tomography (CT) pulmonary angiography is considered the gold standard for pulmonary embolism (PE) diagnosis, relying on the discrimination between contrast and embolus. Photon-counting detector CT (PCD-CT) generates monoenergetic reconstructions through energy-resolved detection. Virtual monoenergetic images (VMI) at low keV can be used to improve pulmonary artery opacification. While studies have assessed VMI for PE diagnosis on dual-energy CT (DECT), there is a lack of literature on optimal settings for PCD-CT-PE reconstructions, warranting further investigation. Material and methods: Twenty-five sequential patients who underwent PCD-CT pulmonary angiography for suspicion of acute PE were retrospectively included in this study. Quantitative metrics including signal-to-noise ratio (SNR) and contrast-to-noise (CNR) ratio were calculated for 4 VMI values (40, 60, 80, and 100 keV). Qualitative measures of diagnostic quality were obtained for proximal to distal pulmonary artery branches by 2 cardiothoracic radiologists using a 5-point modified Likert scale. Results: SNR and CNR were highest for the 40 keV VMI (49.3 ± 22.2 and 48.2 ± 22.1, respectively) and were inversely related to monoenergetic keV. Qualitatively, 40 and 60 keV both exhibited excellent diagnostic quality (mean main pulmonary artery: 5.0 ± 0 and 5.0 ± 0; subsegmental pulmonary arteries 4.9 ± 0.1 and 4.9 ± 0.1, respectively) while distal segments at high (80-100) keVs had worse quality. Conclusions: 40 keV was the best individual VMI for the detection of pulmonary embolism by quantitative metrics. Qualitatively, 40-60 keV reconstructions may be used without a significant decrease in subjective quality. VMIs at higher keV lead to reduced opacification of the distal pulmonary arteries, resulting in decreased image quality.

3.
Radiology ; 307(2): e222030, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36719292

RESUMO

Background Photon-counting detector (PCD) CT provides comprehensive spectral data with every acquisition, but studies evaluating myocardial extracellular volume (ECV) quantification with use of PCD CT compared with an MRI reference remain lacking. Purpose To compare ECV quantification for myocardial tissue characterization between a first-generation PCD CT system and cardiac MRI. Materials and Methods In this single-center prospective study, adults without contraindication to iodine-based contrast media underwent same-day cardiac PCD CT and MRI with native and postcontrast T1 mapping and late gadolinium enhancement for various clinical indications for cardiac MRI (the reference standard) between July 2021 and January 2022. Global and midventricular ECV were assessed with use of three methods: single-energy PCD CT, dual-energy PCD CT, and MRI T1 mapping. Quantitative comparisons among all techniques were performed. Correlation and reliability between different methods of ECV quantification were assessed with use of the Pearson correlation coefficient (r) and the intraclass correlation coefficient. Results The final sample included 29 study participants (mean age ± SD, 54 years ± 17; 15 men). There was a strong correlation of ECV between dual- and single-energy PCD CT (r = 0.91, P < .001). Radiation dose was 40% lower with dual-energy versus single-energy PCD CT (volume CT dose index, 10.1 mGy vs 16.8 mGy, respectively; P < .001). In comparison with MRI, dual-energy PCD CT showed strong correlation (r = 0.82 and 0.91, both P < .001) and good to excellent reliability (intraclass correlation coefficients, 0.81 and 0.90) for midventricular and global ECV quantification, but it overestimated ECV by approximately 2%. Single-energy PCD CT showed similar relationship with MRI but underestimated ECV by 3%. Conclusion Myocardial tissue characterization with photon-counting detector CT-based quantitative extracellular volume analysis showed a strong correlation to MRI. © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Meios de Contraste , Gadolínio , Masculino , Adulto , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos
4.
Eur Radiol ; 33(4): 2469-2477, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36462045

RESUMO

OBJECTIVES: To assess the impact of scan modes and reconstruction kernels using a novel dual-source photon-counting detector CT (PCD-CT) on lumen visibility and sharpness of different stent sizes. METHODS: A phantom containing six balloon-expandable stents (2.5 to 9 mm diameter) in silicone tubing was scanned on a PCD-CT with standard (0.6 mm and 0.4 mm thicknesses) and ultra-high-resolution (0.2 mm thickness) modes. With the use of increasing contrast medium concentrations, densities of 0, 200, 400, and 600 HU were achieved. Standard-resolution scans were reconstructed using increasing sharpness kernels, using both polyenergetic quantitative soft tissue "conventional" ((Qr40c(0.6 mm), Qr40c(0.4 mm), Qr72c(0.2 mm)) and vascular (Bv) virtual monoenergetic reconstructions (Bv44m(0.4 mm), Bv60m(0.4 mm)) at 70 keV. In-stent lumen visibility, sharpness (max. ΔHU of the stent measured in profile plots), and in-stent noise (standard deviation of HU) were measured. RESULTS: In-stent lumen visibility was highest for Qr72c(0.2 mm) (86.5 ± 2.8% to 88.3 ± 2.6%) and in Bv60m(0.4 mm) reconstructions (77.3 ± 2.9 to 82.7 ± 2.5%). Lumen visibility was lowest in the smallest stent (2.5 mm) ranging from 54.1% in Qr40c(0.6 mm) to 74.1% in Qr72c(0.2 mm) and highest in the largest stent (9 mm) ranging from 93.8% in Qr40c(0.6 mm) to 99.1% in the Qr72c(0.2 mm) series. Lumen visibility decreased by 2.1% for every 200-HU increase in lumen attenuation. Max. ΔHU between stents and stent lumen was highest in Qr72c(0.2 mm) (ΔHU 892 ± 504 to 1526 ± 517) and Bv60m(0.4 mm) series (ΔHU 480 ± 357 to 1030 ± 344). Improvement of lumen visibility and sharpness in UHR and Bv60m(0.4 mm) series was strongest in smaller stent sizes. CONCLUSION: UHR acquisition mode and sharp reconstruction kernels on a novel PCD-CT system significantly improve in-stent lumen visibility and sharpness-especially for smaller stent sizes. KEY POINTS: • In-stent lumen visibility and sharpness of stents significantly improve using sharp reconstruction kernels (Bv60) and ultra-high-resolution mode in photon-counting detector computed tomography. • The observed improvement of stent-lumen visibility was highest in smaller stent sizes.


Assuntos
Stents , Tomografia Computadorizada por Raios X , Humanos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Imagens de Fantasmas
5.
Acta Radiol ; 64(10): 2722-2730, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37649280

RESUMO

BACKGROUND: Detecting occlusions of coronary artery bypass grafts using non-contrast computed tomography (CT) series is understudied and underestimated. PURPOSE: To evaluate morphological findings for the diagnosis of chronic coronary artery bypass graft occlusion on non-contrast CT and investigate performance statistics for potential use cases. MATERIAL AND METHODS: Seventy-three patients with coronary artery bypass grafts who had CT angiography of the chest (non-contrast and arterial phases) were retrospectively included. Two readers applied pre-set morphologic findings to assess the patency of a bypass graft on non-contrast series. These findings included vessel shape (linear-band like), collapsed lumen and surgical graft marker without a visible vessel. Performance was tested using the simultaneously acquired arterial phase series as the ground truth. RESULTS: The per-patient diagnostic accuracy for occlusion was 0.890 (95% confidence interval = 0.795-0.951). Venous grafts overall had an 88% accuracy. None of the left internal mammary artery to left anterior descending artery arterial graft occlusions were detected. The negative likelihood ratio for an occluded graft that is truly patent was 0.121, demonstrating a true post-test probability of 97% for identifying a patent graft as truly patent given a prevalence of 20% occlusion at a median 8.4 years post-surgery. Neither years post-surgery, nor number of vessels was associated with a significant decrease in reader accuracy. CONCLUSION: Evaluation of coronary bypass grafts for chronic occlusion on non-contrast CT based off vessel morphology is feasible and accurate for venous grafts. Potential use cases include low-intermediate risk patients with chest pain or shortness of breath for whom non-contrast CT was ordered, or administration of iodine-based contrast is contraindicated.


Assuntos
Ponte de Artéria Coronária , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Angiografia Coronária/métodos , Grau de Desobstrução Vascular , Sensibilidade e Especificidade , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem
6.
Pol J Radiol ; 88: e423-e429, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37808170

RESUMO

Purpose: Left atrial calcification (LAC), a primarily radiologic diagnosis, has been associated with rheumatic heart disease (RHD) and rheumatic fever (RF). However, left atrial calcification continues to be observed despite a significant decrease in the prevalence of rheumatic heart disease. The purpose of this study was to investigate other possible etiologies of left atrial calcification. Material and methods: This retrospective, observational single-center study included patients from 2017 to 2022 identified as having left atrial calcification as well as age- and sex-matched controls. The prevalence of rheumatic heart disease, atrial ablation, and mitral valve disease was compared, and odds ratios were calculated for each independent variable. Results: Sixty-two patients with left atrial calcifications were included and compared with 62 controls. 87.1% of patients in the left atrial calcifications cohort had a history of atrial fibrillation compared with 21% in the control cohort (p < 0.001). 16.1% of patients in the calcifications cohort presented a history of rheumatic fever compared with zero in the control cohort (p = 0.004). 66.1% of the left atrial calcifications cohort had a history of atrial ablation compared with 6.5% of the control group (p < 0.001). The odds ratio for left atrial calcification was 19.0 vs. 4.8 for rheumatic fever (comparative odds = 4.0 for atrial ablation vs. rheumatic fever). Multivariable log model found atrial ablation to explain 79.8% of left atrial calcifications identified. Conclusions: Our study found a 4-fold higher association between history of atrial ablation and left atrial calcification compared with rheumatic heart disease, suggesting a potential shift in etiology.

7.
AJR Am J Roentgenol ; 219(5): 743-751, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35703413

RESUMO

BACKGROUND. Deep learning-based convolutional neural networks have enabled major advances in development of artificial intelligence (AI) software applications. Modern AI applications offer comprehensive multiorgan evaluation. OBJECTIVE. The purpose of this article was to evaluate the impact of an automated AI platform integrated into clinical workflow for chest CT interpretation on radiologists' interpretation times when evaluated in a real-world clinical setting. METHODS. In this prospective single-center study, a commercial AI software solution was integrated into clinical workflow for chest CT interpretation. The software provided automated analysis of cardiac, pulmonary, and musculoskeletal findings, including labeling, segmenting, and measuring normal structures as well as detecting, labeling, and measuring abnormalities. AI-annotated images and autogenerated summary results were stored in the PACS and available to interpreting radiologists. A total of 390 patients (204 women, 186 men; mean age, 62.8 ± 13.3 [SD] years) who underwent out-patient chest CT between January 19, 2021, and January 28, 2021, were included. Scans were randomized using 1:1 allocation between AI-assisted and non-AI-assisted arms and were clinically interpreted by one of three cardiothoracic radiologists (65 scans per arm per radiologist; total of 195 scans per arm) who recorded interpretation times using a stopwatch. Findings were categorized according to review of report impressions. Interpretation times were compared between arms. RESULTS. Mean interpretation times were significantly shorter in the AI-assisted than in the non-AI-assisted arm for all three readers (289 ± 89 vs 344 ± 129 seconds, p < .001; 449 ± 110 vs 649 ± 82 seconds, p < .001; 281 ± 114 vs 348 ± 93 seconds, p = .01) and for readers combined (328 ± 122 vs 421 ± 175 seconds, p < .001). For readers combined, the mean difference was 93 seconds (95% CI, 63-123 seconds), corresponding with a 22.1% reduction in the AI-assisted arm. Mean interpretation time was also shorter in the AI-assisted arm compared with the non-AI-assisted arm for contrast-enhanced scans (83 seconds), noncontrast scans (104 seconds), negative scans (84 seconds), positive scans without significant new findings (117 seconds), and positive scans with significant new findings (92 seconds). CONCLUSION. Cardiothoracic radiologists exhibited a 22.1% reduction in chest CT interpretations times when they had access to results from an automated AI support platform during real-world clinical practice. CLINICAL IMPACT. Integration of the AI support platform into clinical workflow improved radiologist efficiency.


Assuntos
Inteligência Artificial , Tomografia Computadorizada por Raios X , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Radiologistas , Redes Neurais de Computação , Estudos Retrospectivos
8.
BMC Infect Dis ; 22(1): 637, 2022 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-35864468

RESUMO

BACKGROUND: Airspace disease as seen on chest X-rays is an important point in triage for patients initially presenting to the emergency department with suspected COVID-19 infection. The purpose of this study is to evaluate a previously trained interpretable deep learning algorithm for the diagnosis and prognosis of COVID-19 pneumonia from chest X-rays obtained in the ED. METHODS: This retrospective study included 2456 (50% RT-PCR positive for COVID-19) adult patients who received both a chest X-ray and SARS-CoV-2 RT-PCR test from January 2020 to March of 2021 in the emergency department at a single U.S. INSTITUTION: A total of 2000 patients were included as an additional training cohort and 456 patients in the randomized internal holdout testing cohort for a previously trained Siemens AI-Radiology Companion deep learning convolutional neural network algorithm. Three cardiothoracic fellowship-trained radiologists systematically evaluated each chest X-ray and generated an airspace disease area-based severity score which was compared against the same score produced by artificial intelligence. The interobserver agreement, diagnostic accuracy, and predictive capability for inpatient outcomes were assessed. Principal statistical tests used in this study include both univariate and multivariate logistic regression. RESULTS: Overall ICC was 0.820 (95% CI 0.790-0.840). The diagnostic AUC for SARS-CoV-2 RT-PCR positivity was 0.890 (95% CI 0.861-0.920) for the neural network and 0.936 (95% CI 0.918-0.960) for radiologists. Airspace opacities score by AI alone predicted ICU admission (AUC = 0.870) and mortality (0.829) in all patients. Addition of age and BMI into a multivariate log model improved mortality prediction (AUC = 0.906). CONCLUSION: The deep learning algorithm provides an accurate and interpretable assessment of the disease burden in COVID-19 pneumonia on chest radiographs. The reported severity scores correlate with expert assessment and accurately predicts important clinical outcomes. The algorithm contributes additional prognostic information not currently incorporated into patient management.


Assuntos
COVID-19 , Aprendizado Profundo , Adulto , Inteligência Artificial , COVID-19/diagnóstico por imagem , Humanos , Prognóstico , Radiografia Torácica , Estudos Retrospectivos , SARS-CoV-2 , Tomografia Computadorizada por Raios X , Raios X
9.
J Allergy Clin Immunol ; 147(2): 704-712.e17, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32745555

RESUMO

BACKGROUND: Granulomatous and lymphocytic interstitial lung disease (GLILD) is a life-threatening complication in patients with common variable immunodeficiency (CVID), but the optimal treatment is unknown. OBJECTIVE: Our aim was to determine whether rituximab with azathioprine or mycophenolate mofetil improves the high-resolution computed tomography (HRCT) chest scans and/or pulmonary function test results in patients with CVID and GLILD. METHODS: A retrospective chart review of clinical and laboratory data on 39 patients with CVID and GLILD who completed immunosuppressive therapy was performed. Chest HRCT scans, performed before therapy and after the conclusion of therapy, were blinded, randomized, and scored independently by 2 radiologists. Differences between pretreatment and posttreatment HRCT scan scores, pulmonary function test results, and lymphocyte subsets were analyzed. Whole exome sequencing was performed on all patients. RESULTS: Immunosuppressive therapy improved patients' HRCT scan scores (P < .0001), forced vital capacity (P = .0017), FEV1 (P = .037), and total lung capacity (P = .013) but not their lung carbon monoxide diffusion capacity (P = .12). Nine patients relapsed and 6 completed retreatment, with 5 of 6 of these patients (83%) having improved HRCT scan scores (P = .063). Relapse was associated with an increased number of B cells (P = .016) and activated CD4 T cells (P = .016). Four patients (10%) had pneumonia while undergoing active treatment, and 2 patients (5%) died after completion of therapy. Eight patients (21%) had a damaging mutation in a gene known to predispose (TNFRSF13B [n = 3]) or cause a CVID-like primary immunodeficiency (CTLA4 [n = 2], KMT2D [n = 2], or BIRC4 [n = 1]). Immunosuppression improved the HRCT scan scores in patients with (P = .0078) and without (P < .0001) a damaging mutation. CONCLUSIONS: Immunosuppressive therapy improved the radiographic abnormalities and pulmonary function of patients with GLILD. A majority of patients had sustained remissions.


Assuntos
Imunodeficiência de Variável Comum/complicações , Imunodeficiência de Variável Comum/tratamento farmacológico , Imunossupressores/uso terapêutico , Doenças Pulmonares Intersticiais/tratamento farmacológico , Doenças Pulmonares Intersticiais/etiologia , Adolescente , Adulto , Azatioprina/uso terapêutico , Inibidores Enzimáticos/uso terapêutico , Feminino , Humanos , Masculino , Ácido Micofenólico/uso terapêutico , Testes de Função Respiratória , Estudos Retrospectivos , Rituximab/uso terapêutico , Adulto Jovem
10.
Radiographics ; 40(5): 1284-1308, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32822281

RESUMO

Multienergy CT involves acquisition of two or more CT measurements with distinct energy spectra. Using the differential attenuation of tissues and materials at different x-ray energies, multienergy CT allows distinction of tissues and materials beyond that possible with conventional CT. Multienergy CT technologies can operate at the source or detector level. Dual-source, rapid tube-voltage switching, and dual-layer detector CT are the most commonly used multienergy CT technologies. Most of the currently available technologies typically use two energy levels, commonly referred to as dual-energy CT. With use of two or more energy bins, photon-counting detector CT can perform multienergy CT beyond current dual-energy CT technologies. Multienergy CT postprocessing can be performed in the projection or image domain using two-material or multimaterial decomposition. The most commonly used multienergy CT images are virtual monoenergetic images (VMIs), iodine maps, virtual noncontrast (VNC) images, and uric acid images. Low-energy VMIs are used to boost contrast signal and enhance lesion conspicuity. High-energy VMIs are used to decrease some artifacts. Iodine maps are used to evaluate perfusion, characterize lesions, and evaluate response to therapy. VNC images are used to characterize lesions and save radiation dose by eliminating true noncontrast images from multiphasic acquisitions. Uric acid images are used for characterization of renal calculi and gout. Online supplemental material is available for this article. ©RSNA, 2020.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Física
15.
Eur Spine J ; 24(9): 1944-50, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25212450

RESUMO

PURPOSE: Quantitative MRI techniques were utilized to study intervertebral disc degeneration. Main focus was to develop a novel approach to quantify disc height loss associated with disc degeneration. Currently there is no universally accepted metric of degeneration based on measurement of disc height. Such quantitative imaging methods would complement qualitative visual assessment methods currently used and offer a valuable diagnostic tool. METHODS: 51 adult participants took part in this MRI study. T2 weighted images were used to obtain disc height index (DHI) and also a semi-quantitative metric based on relative voxel intensities. For DHI, each disc was given a score based on standard deviations from the mean DHI of healthy discs. Diffusion Weighted MRI was used to assess morphological changes in the nucleus pulposus. Conventional Pfirrmann classification was used as the gold standard to assess these quantitative approaches. RESULTS: At deviations of up to 1.5σ below normative disc height, levels of apparent diffusion coefficient (ADC) and normalized T2 intensity were maintained. Once disc compression reached 1.5σ, there was a massive drop in ADC and normalized T2 intensity. Pfirrmann degeneration scores also increased after the 1.5σ mark. CONCLUSIONS: This study provides new, unbiased quantitative imaging tools to assess disc degeneration. We observed that these quantitative MRI measures indicate a threshold beyond which major pathological changes take place concurrently. Combined information from DHI, ADC and T2 images construct a set of novel biomarkers that could be used to identify degenerating discs that are approaching the threshold and possibly intervene before major pathologic changes occur.


Assuntos
Degeneração do Disco Intervertebral/patologia , Vértebras Lombares/patologia , Adulto , Análise de Variância , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
17.
J Thorac Imaging ; 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39330765

RESUMO

Drug-induced acute lung injury is a significant yet often underrecognized clinical challenge, associated with a wide range of therapeutic agents, including chemotherapy drugs, antibiotics, anti-inflammatory drugs, and immunotherapies. This comprehensive review examines the pathophysiology, clinical manifestations, and radiologic findings of drug-induced acute lung injury across different drug categories. Common imaging findings are highlighted to aid radiologists and clinicians in early recognition and diagnosis. The review emphasizes the importance of immediate cessation of the offending drug and supportive care, which may include corticosteroids. Understanding these patterns is crucial for prompt diagnosis and management, potentially improving patient outcomes.

18.
Acad Radiol ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38876842

RESUMO

RATIONALE AND OBJECTIVES: Managing contrast reactions is critical as contrast reactions can be life-threatening and unpredictable. Institutions need an effective system to handle these events. Currently, there is no standard practice for assigning trainees, radiologists, non-radiologist physicians, or other non-physician providers for management of contrast reaction. MATERIALS AND METHODS: The Association of Academic Radiologists (AAR) created a task force to address this gap. The AAR task force reviewed existing practices, studied available literature, and consulted experts related to contrast reaction management. The Society of Chairs of Academic Radiology Departments (SCARD) members were surveyed using a questionnaire focused on staffing strategies for contrast reaction management. RESULTS: The task force found disparities in contrast reactions management across institutions and healthcare providers. There is a lack of standardized protocols for assigning personnel for contrast reaction management. CONCLUSION: The AAR task force suggests developing standardized protocols for contrast reaction management. The protocols should outline clear roles for different healthcare providers involved in these events.

19.
Clin Imaging ; 113: 110235, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39059085

RESUMO

OBJECTIVE: This study aims to assess the efficacy of polyenergetic reconstruction methods in reducing streak artifacts caused by dual source imaging in Photon Counting Detector Computed Tomography (PCD-CT) imaging, thereby improving image quality and diagnostic accuracy. METHODS: A retrospective cohort study was conducted, involving 50 patients who underwent chest Computed Tomography Angiography with PCD-CT, focusing on those with streak artifacts. Quantitative and qualitative analyses were performed on images reconstructed using monoenergetic and polyenergetic techniques. Quantitative evaluations measured the attenuation of tracheal air density in regions affected by streak artifacts, while qualitative assessments employed a modified Likert scale to rate image quality. Statistical analyses included Wilcoxon's signed-rank tests and Spearman's correlation, alongside assessments of inter-rater reliability. RESULTS: There was significantly lower attenuation of tracheal air density on the polyenergetic reconstructions (Median - 1010 ± 62 HU vs -930 ± 110 HU; P < 0.001), and significantly decreased variation on the polyenergetic reconstructions (Median 65.2 ± 79.5 HU vs 38.8 ± 33.9 HU; P < 0.001). The median modified-Likert scale were significantly better for the polyenergetic reconstructions (median modified-Likert 4 ± 0.5 vs 2.5 ± 1; P < 0.001). The inter-rater agreement was substantial and not significantly different between reconstructions (Gwet's ACPolyenergetic = 0.78 vs Gwet's ACVMI = 0.775). CONCLUSION: Polyenergetic reconstruction significantly mitigates streak artifacts in PCD-CT imaging, enhancing quantitative and qualitative image quality. This advancement addresses a known limitation of current PCD-CT reconstruction techniques, offering a promising approach to improving diagnostic reliability and accuracy in clinical practice. We demonstrate that future software implementations can resolve this artifact.


Assuntos
Artefatos , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Angiografia por Tomografia Computadorizada/métodos , Idoso de 80 Anos ou mais , Adulto , Tomografia Computadorizada por Raios X/métodos , Radiografia Torácica/métodos
20.
Radiol Cardiothorac Imaging ; 6(4): e230328, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39023373

RESUMO

Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Doença da Artéria Coronariana , Imagens de Fantasmas , Placa Aterosclerótica , Humanos , Masculino , Feminino , Estudos Prospectivos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Idoso , Fótons , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Angiografia Coronária/métodos , Meios de Contraste
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA