Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38932605

RESUMO

PURPOSE: This study aims to assess the functional outcomes based on restoring the anterior compartment after total knee arthroplasty (TKA). METHODS: This retrospective study included 96 primary TKAs performed between 2021 and 2022. Functional positioning principles were applied using an image-based robotic-assisted system. The mean age was 69.2 ± 7.9 years. Knee Society Score (KSS), Kujala score, Forgotten Joint Score (FJS) and knee flexion were collected preoperatively and at 1 year. The depth difference between native and prosthetic trochlea was measured to assess anterior compartment restoration at full extension, 30°, 70° and 90° flexion. The global anterior compartment restoration combined the anterior compartment restoration and the patellar thickness restoration. RESULTS: The trochlear offset was mostly understuffed after TKA compared to the native anatomy, mainly for medial and lateral condyles at 30° and 70° of flexion. The global anterior compartment restoration was understuffed in full extension (-0.7 mm ± 2), at 30° (-4.4 mm ± 2) and 70° of flexion (-3.6 mm ± 2.5). At 90°, the global anterior compartment restoration was overstuffed (2.2 mm ± 1.8). Functional scores were not significantly influenced by the anterior compartment stuffing at 0° and 30° (n.s.). The anterior compartment overstuffing at 70° and 90° was associated with decreased KSS function score (p = 0.009) and flexion (p = 0.04). CONCLUSION: Moderate anterior understuffing was frequently observed after TKA performed with functional positioning and an image-based robotic-assisted system. This understuffing did not influence the functional outcomes. The overstuffing of the anterior compartment led to a reduction in KSS function score and flexion measurements at 1 year. LEVEL OF EVIDENCE: Level III, retrospective cohort study.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38680026

RESUMO

PURPOSE: The impact of gender on the outcomes of unicompartmental knee arthroplasty (UKA) remains a topic of active discussion with limited exploration thus far. The study aims to elucidate the gender effect on clinical outcomes, complications, pre- and postoperative radiological outcomes following the implantation of a medial UKA at mid-term follow-up in a large section of patients. METHODS: This was a single-centre, retrospective cohort study encompassing patients undergoing medial UKA between 2011 and 2019. The International Knee Society (IKS) Knee and Function score, patient satisfaction, complications, revisions, pre- and postoperative radiological outcomes (coronal plane alignment, femoral and tibial component positioning, posterior tibial slope) were evaluated. Survival rate at the time of the last follow-up was also recorded. RESULTS: Of the 366 knees that met the inclusion criteria, 10 were lost to follow-up, accounting for a 2.7% loss. Mean follow-up was 5.2 ± 2 years [2.1-11.3]. Out of the total population, 205 patients were females (57.6%, 205/356) and 151 were males (42.4%, 151/356). Men exhibited superior pre- and postoperative IKS function scores (p = 0.017). However, no significant differences were observed between women and men regarding improvements of IKS Knee and Function scores, radiographic outcomes and implant survivorship. CONCLUSION: At a mean follow-up of 5 years, this study revealed no significant impact of gender on clinical outcomes and complications in patients undergoing medial UKA. Furthermore, no significant differences were evident in radiographic outcomes, implant positioning and knee phenotype. LEVEL OF EVIDENCE: Level III.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38738818

RESUMO

PURPOSE: Functional implant positioning (FIP) for total knee arthroplasty (TKA) is an evolution of kinematic alignment based on preoperative CT scan and robotic-assisted technology. This study aimed to assess the ligament balancing of image-based robotic-assisted TKA in extension, mid-flexion and flexion with an FIP using intraoperative sensor-guided technology. The hypothesis was that image-based robotic-assisted TKA performed by FIP would achieve ligament balancing all along the arc of knee flexion. METHODS: This prospective monocentric study included 47 consecutive patients with varus knees undergoing image-based robotic-assisted TKA performed with FIP. After robotic-assisted bone cuts, trial components were inserted, and soft tissue balance was assessed using sensor-guided technology at 10°, 45° and 90° of knee flexion. A mediolateral balanced knee was defined by an intercompartmental pressure difference (ICPD) ≤ 15 lbf and medial and lateral compartment pressure ≤60 lbf. The mean age was 71.6 years old ±6.7, the mean BMI was 29.0 kg/m2 ± 4.9 and the mean preoperative HKA was 174° ± 5 [159; 183]. RESULTS: The mean postoperative knee alignment was 177.0° ± 2.2° [172; 181]. There were 93.6% of balanced knees (n = 44) at 10 and 90° of knee flexion versus 76.6% (n = 36) at 45° of knee flexion with a significant difference (p = 0.014). Median ICPD at 10, 45 and 90° of knee flexion were, respectively, 7.0 (interquartile range [IQR]: 9), 11.0 (IQR: 9.5) and 8.0 (IQR: 9.0). Pairwise analyses revealed differences for ICPD at 45° versus ICPD at 10° (p = 0.003) and ICPD at 90° versus ICPD at 45° (p = 0.007). CONCLUSION: FIP with an image-based robotic-assisted system allowed the restoration of a well-balanced knee at 10° and 90° of flexion in varus knees. Nevertheless, some discrepancies occurred in midflexion, and more work is needed to understand ligament behaviour all along the arc of knee flexion. LEVEL OF EVIDENCE: Level II.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38769805

RESUMO

PURPOSE: The association between the prevalence of patellofemoral arthritis (PFA) and femoral tunnel positioning following isolated medial patellofemoral ligament reconstruction (MPFLr) has not been well described. The aim of this study was to analyse the relationship between femoral tunnel positioning and the prevalence of PFA. METHODS: This was a single-centre study of patients undergoing an isolated MPFLr between 2006 and 2011 with a minimum of 10 years of follow-up. Outcomes assessed were the presence of PFA on radiographs, recurrence of instability requiring revision surgery and patient-reported outcomes, including Kujala, Tegner and IKDC scores. Tunnel positioning was assessed on postoperative radiographs using two radiographic methods: Schöttle's point and the grid method to localise the femoral tunnel. Patients were grouped based on tunnel positioning and compared. RESULTS: Fifty patients were analysed at a mean follow-up of 12.4 years. Thirty-three patients (66%) had a femoral tunnel position within 7 mm of Schöttle's point and 39 (78%) within the anatomic quadrant, with the most common location according to the grid method in D4 (28%) and E4 (26%), respectively. Thirty-seven patients (74%) had a satisfactory (>80 versus <80) Kujala score at long-term follow-up. None of the examined tunnel assessment methods demonstrated a significant relationship with Tegner, Kujala or International Knee Documentation Committee scores. Patients with a femoral tunnel position >7 mm outside Schöttle's point or were considered to be in a nonanatomic position were not significantly more likely to result in unsatisfactory Kujala scores at the last follow-up. Tunnel positioning and the other tested parameters were not found to be significantly associated with the development of PFA. CONCLUSION: No correlation between femoral tunnel position and risk of PFA or poor outcomes was observed in patients undergoing isolated MPFLr at long-term follow-up. The impact of femoral tunnel placement on long-term outcomes in patients with PFI may be less significant than originally considered. LEVEL OF EVIDENCE: Level IV.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38819941

RESUMO

PURPOSE: Predictive models help determine predictive factors necessary to improve functional outcomes after total knee arthroplasty (TKA). However, no study has assessed predictive models for functional outcomes after TKA based on the new concepts of personalised surgery and new technologies. This study aimed to develop and evaluate predictive modelling approaches to predict the achievement of minimal clinically important difference (MCID) in patient-reported outcome measures (PROMs) 1 year after TKA. METHODS: Four hundred thirty robotic-assisted TKAs were analysed in this retrospective study. The mean age was 67.9 ± 7.9 years; the mean body mass index (BMI) was 32.0 ± 6.8 kg/m2. The following PROMs were collected preoperatively and 1-year postoperatively: knee injury and osteoarthritis outcome score for joint replacement, Western Ontario and McMaster Universities osteoarthritis index (WOMAC) Function, WOMAC Pain. Demographic data, preoperative CT scan, implant size, implant position on the robotic system and characteristics of the joint replacement procedure were selected as predictive variables. Four machine learning algorithms were trained to predict the MCID status at 1-year post-TKA for each PROM survey. 'No MCID' was chosen as the target. Models were evaluated by class discrimination (F1-score) and area under the receiver operating characteristic curve (ROC-AUC). RESULTS: The best-performing model was ridge logistic regression for WOMAC Function (area under the curve [AUC] = 0.80, F1 = 0.48, sensitivity = 0.79, specificity = 0.62). Variables most strongly contributing to not achieving MCID status were preoperative PROMs, high BMI and femoral resection depth (posterior and distal), supporting functional positioning principles. Conversely, variables contributing to a positive outcome (achieving MCID) were medial/lateral alignment of the tibial component, whether the procedure was an outpatient surgery and whether the patient received managed Medicare insurance. CONCLUSION: The most predictive variables included preoperative PROMs, BMI and surgical planning. The surgical predictive variables were valgus femoral alignment and femoral rotation, reflecting the benefits of personalised surgery. Including surgical variables in predictive models for functional outcomes after TKA should guide clinical and surgical decision-making for every patient. LEVEL OF EVIDENCE: Level III.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38690988

RESUMO

PURPOSE: The objective of this study was to compare the degree of accuracy in implant positioning and limb alignment offered by two robot-assisted (RA) systems: an image-based robot-assisted (IBRA) versus an imageless robot-assisted (ILRA) system for the treatment of medial knee osteoarthritis with unicompartmental knee arthroplasty (UKA). METHODS: This retrospective radiographic study included medial UKAs performed between 2011 and 2023. Radiographic measurements taken preoperatively and at 1-year postoperative control visit focusing on hip-knee-ankle angle (HKA), posterior tibial slope (PTS), tibial component coronal alignment relative to Cartier's angle and restoration of proper joint line (JL) height were analyzed. Outliers for postoperative measurements were defined as follows: HKA <175° or >180°, PTS <2° or >8°, >3° or <-3° alterations in Cartier's angle and ±2 mm changes in the height of the joint line. RESULTS: The final sample consisted of 292 medial UKAs: 95 (32.5%) with an IBRA system and 197 (67.5%) with an ILRA system. Implant positioning and limb alignment were more accurate in the group of patients treated with IBRA, HKA (77.9% vs. 67.5%, p = 0.07), PTS (93.7% vs. 82.7%, p = 0.01), restoration of tibial varus relative to Cartier's angle (87.4% vs. 65%, p < 0.001) and restoration of JL height (81.1% vs. 69.5%, p = 0.04). CONCLUSION: Medial UKA surgery using an IBRA system was associated with a higher degree of accuracy in implant positioning and postoperative limb alignment as compared to an ILRA system. This is a valuable contribution to help communicate the advantages of using this surgical technique and improve its reproducibility. LEVEL OF EVIDENCE: Level III, Retrospective cohort study.

7.
Int Orthop ; 48(7): 1761-1769, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38743298

RESUMO

PURPOSE: Lateral unicompartmental knee arthroplasty (UKA) is an accepted treatment option in cases of end-stage lateral osteoarthritis. While lateral UKA has many proposed advantages compared to total knee arthroplasty, its technical challenges and relatively small number of cases make this an uncommon procedure. The aim of this study was to report the survivorship and functional outcomes beyond 20 years of follow-up of isolated UKA. METHODS: Between January 1988 and October 2003, 54 lateral UKAs were performed in a single center. The fitted prosthesis was a fixed plate and cemented polyethylene (PE). All patients had isolated lateral tibiofemoral osteoarthritis, including five open meniscectomies, three arthroscopies, and three open reductions of lateral tibial plateau fractures. Patients with a minimum of 20 years of follow-up were included in the final analysis. RESULTS: Of the 54 UKA, 22 died before reaching the minimum follow-up period and four were lost to follow-up. Twenty-eight were included in the final analysis. Among them, 21 patients remained alive and an additional seven were deceased after 20 years. The mean age at the last follow-up was 84.8 ± 11.9 years with a mean follow-up duration of 22.5 ± 2.1 years. Of the 28 knees, eight underwent revision surgery (5 for the progression of osteoarthritis; 2 for aseptic loosening; 1 for PE wear). Kaplan-Meier survival analysis revealed a survival rate at 20 and 25 years of 72.3% (CI 59.1; 88.6). The average time to revision was 14.9 ± 4.9 years. At the last follow-up, the mean function Knee Society Score (KSS) was 41.5 ± 32.9 and the mean objective KSS score was 79.4 ± 9.7. In the unrevised population, 94.7% of patients (n = 18) reported being satisfied or very satisfied with the surgery. CONCLUSION: Lateral UKA remains a viable treatment option for patients with isolated lateral tibiofemoral osteoarthritis, providing satisfactory 20-year implant survivorship and high patient satisfaction.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Falha de Prótese , Humanos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/instrumentação , Masculino , Feminino , Osteoartrite do Joelho/cirurgia , Seguimentos , Idoso , Idoso de 80 Anos ou mais , Resultado do Tratamento , Pessoa de Meia-Idade , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Reoperação/estatística & dados numéricos , Reoperação/métodos
8.
Artigo em Inglês | MEDLINE | ID: mdl-38967776

RESUMO

INTRODUCTION: More personalized alignment techniques in total knee arthroplasty (TKA) have recently been described particularly for the young and active patients. Performing the ideal tibial cut might be challenging with a conventional ancillary. Therefore the aims of this study were: (1) to describe specific tibial landmarks to optimize the tibial cut in TKA; (2) to compare the accuracy of the tibial cut with these landmarks compared to a conventional technique. METHODS: This retrospective case-control study compared primary TKAs performed using a conventional technique with extramedullary guide associated with specific tibial landmarks. For each case, one control patient was matched based on body mass index (BMI), age, preoperative Hip Knee Ankle (HKA) angle, and Medial Proximal Tibial Angle (MPTA). All control patients were operated by the same surgeon and similar conventional technique but without landmarks. The MPTA target was to reproduce preoperative deformity with a 3° of varus limit. 34 TKA were included in each group. There was no preoperative difference between both groups. Mean age was 63 years old ± 8. Mean BMI was 32 kg/m2 ± 5. Mean HKA was 170.6° ± 2.5. Mean MPTA was 85.1° ± 2.3. The radiographic assessment was performed preoperatively and at 2 months: HKA, mechanical Medial Distal Femoral Angle (mMDFA), MPTA, tibial slope, restoration of the joint line-height. RESULTS: The tibial landmarks corresponded to the line of insertion of the deep medial collateral ligament fibers extended to the capsular insertion above the Gerdy tubercle. The postoperative MPTA was significantly more varus (87.2° ± 1.6 in landmark group versus 88.3° ± 2.2; p = 0.027) and closer to preoperative bone deformity in landmark group (p = 0.002) with significantly less outliers than in the conventional group. There was no significant difference between both groups postoperatively for HKA (175.4° ± 2.3 versus 175.9° ± 2.5; p = 0.42); mMDFA (88.9° ± 2.3 versus 88.2° ± 2.1; p = 0.18); tibial slope (82.6° ± 1.9 versus 82.4° ± 2.6; p = 0.67), the restoration of the joint line-height (1.5 mm ± 2 versus 1.8 mm ± 2; p = 0.56). CONCLUSION: Specific tibial landmarks during TKA can be used to increase the accuracy of the tibial cut when using personalized alignment techniques in TKA. LEVEL OF EVIDENCE: IV.

9.
Arthroscopy ; 39(2): 349-357, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35988794

RESUMO

PURPOSE: To report the long-term clinical outcomes after isolated medial patellofemoral ligament reconstruction (MPFLr) to treat recurrent patellar instability. METHODS: This was a single-center study of patients undergoing an isolated MPFLr between 2000 and 2011. All patients underwent reconstruction using hamstring autograft. The inclusion criteria were a minimum 10-year follow-up period and skeletally mature patients with more than 1 episode of patellar dislocation who underwent MPFLr without an associated bony procedure. RESULTS: A total of 54 knees were available for final analysis. The mean follow-up period was 12.3 years (range, 10-14 year). The mean age at surgery was 25 years. No patients had patellofemoral arthritis (PFA) prior to surgery. Preoperatively, the mean Caton-Deschamps index was 1.1 and the mean tibial tubercle-trochlear groove distance was 14.9 ± 2 mm (range, 7-17 mm). All patients had trochlear dysplasia according to the Dejour classification. At final follow-up, the mean Kujala score was 82.9 ± 15.3; mean International Knee Documentation Committee score, 78.3 ± 18.5; and mean Tegner score, 4.0 ± 1.7. Patients with an unsatisfactory outcome as determined by a Kujala score lower than 80 had a higher Caton-Deschamps index preoperatively and were more likely to be female patients; however, neither factor reached significance. Of the patients, 33 (66%) had no radiographic evidence of PFA whereas 15 (30%) had Iwano stage 1 and 2 had Iwano stage 2 (4%). At final follow-up, 4 patients (7.4%) had recurrent instability requiring revision surgery. CONCLUSIONS: Isolated MPFLr with gracilis tendon autograft in appropriately selected patients is an effective long-term treatment for recurrent patellofemoral instability with low rates of recurrence. One-third of patients exhibit radiographic evidence of PFA more than 10 years after isolated MPFLr. LEVEL OF EVIDENCE: Level IV, case series.


Assuntos
Instabilidade Articular , Luxação Patelar , Articulação Patelofemoral , Humanos , Feminino , Adulto , Masculino , Articulação Patelofemoral/cirurgia , Instabilidade Articular/cirurgia , Seguimentos , Autoenxertos , Luxação Patelar/cirurgia , Ligamentos Articulares/cirurgia , Tendões/transplante
10.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 814-821, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34557949

RESUMO

PURPOSE: The purpose of this study was to evaluate: (1) improvement of functional and quality of life scores, (2) adverse events, (3) short-term implants survivorship of a newly designed fixed-bearing partial knee replacement (PKR) with a morphometric tibial tray in a large and multicentric population at a minimum follow-up of 2 years. METHODS: From 2017 to 2019, 479 medial PKR were implanted by 16 non-developing surgeons from United States, Europe, and Japan. Eight patients were lost to follow-up (1.8%). Standardized follow-up procedures included patient-reported outcomes (Oxford Knee Society score, Forgotten Joint Score, EQ VAS, EQ 5D), patient satisfaction, radiographic assessments, adverse event at 2 years. Comparisons between the preoperative and postoperative values were performed using Student t test. Kaplan-Meier survivorship analysis was performed with knee revision as the endpoint. RESULTS: The mean age was 65.6 ± 9.6 years. Mean body mass index was 29.5 ± 5.1 kg/m2. Oxford Knee Society score and Forgotten Joint Score, respectively, improved from 23.7 ± 8 and 16 ± 15.8 preoperatively to 42.4 ± 6.5 and 74 ± 24.9 at 2 years (p < 0.0001). Satisfaction Score was 92.3 ± 13.4 at 2 years. Ten re-operations (2.1%) were reported including seven implant removals (1.5%). No other adverse event was reported. The causes of conversion to total knee arthroplasty were: nickel allergy (n = 2), patellofemoral osteoarthritis (n = 1), pain (n = 1), deep infection (n = 3). Two re-operations were performed due to infection, and one for internal fixation for a tibial plateau fracture. The 2-year Kaplan-Meier survival estimate was 98.4%, with implant removals as the endpoint. CONCLUSION: This prospective multicentric study reported safe and reliable clinical outcomes of a morphometric PKR, which optimized tibial coverage and femoral fit, in a large population of patients worldwide at 2 years. LEVEL OF EVIDENCE: Prospective cohort study-therapeutic study, Level II.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Pessoa de Meia-Idade , Idoso , Artroplastia do Joelho/métodos , Estudos Prospectivos , Prótese do Joelho/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Reoperação , Seguimentos , Estudos Retrospectivos
11.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 803-813, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33839803

RESUMO

PURPOSE: In recent studies, robotic-assisted surgical techniques for unicompartmental knee arthroplasty (UKA) have demonstrated superior implant positioning and limb alignment compared to a conventional technique. However, the impact of the robotic-assisted technique on clinical and functional outcomes is less clear. The aim of this study was to compare the gait parameters of UKA performed with conventional and image-free robotic-assisted techniques. METHODS: This prospective, single-center study included 66 medial UKA, randomized to a robotic-assisted (n = 33) or conventional technique (n = 33). Gait knee kinematics was assessed on a treadmill at 6 months to identify changes in gait characteristics (walking speed, each degree-of-freedom: flexion-extension, abduction-adduction, internal-external rotation, and anterior-posterior displacement). Clinical results were assessed at 6 months using the IKS score and the Forgotten Joint Score. Implants position was assessed on post-operative radiographs. RESULTS: Post-operatively, the whole gait cycle was not significantly different between groups. In both groups, there was a significant improvement in varus deformity between the pre- and post-operative gait cycle. There was no significant difference between the two groups in clinical scores, implant position, revision, and complication rates. CONCLUSION: No difference of gait parameters could be identified between medial UKA performed with image-free robotic-assisted technique or with conventional technique. LEVEL OF EVIDENCE: Prospective randomized controlled trial.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Prospectivos , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Marcha , Resultado do Tratamento
12.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1334-1346, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35552475

RESUMO

PURPOSE: An anatomo-functional implant positioning (AFIP) technique in total knee arthroplasty (TKA) could restore physiological ligament balance (symmetric gap in extension, asymmetric gap in flexion). The purposes were to compare (1) ligament balancing in extension and flexion after TKA in the AFIP group, (2) TKA alignment, implant positioning and patellar tracking between AFIP and adjusted mechanical alignment (aMA) techniques, (3) clinical outcomes between both groups at 12 months. METHODS: All robotic-assisted TKA with an AFIP technique were included (n = 40). Exclusion criteria were genu valgum (HKA angle > 183°), extra-articular deformity more than 10°, and patellar maltracking (high-grade J-sign). One control patient with a TKA implanted by an aMA technique was matched for each case, based on age, body mass index, sex, and knee alignment. Ligament balancing (medial and lateral gaps in millimeters) in full extension and at 90° of flexion after TKA in the AFIP group was assessed with the robotic system. TKA alignment (HKA angle), implants positioning (femoral and tibial coronal axis, tibial slope, joint-line orientation), patellar tracking (patellar tilt and translation) and the Knee Society Score (KSS) at 6 and 12 months were compared between both groups. The ligament balancing was compared using a t test for paired samples in the AFIP group. The radiographic measurements and KSS scores were compared between groups using a t test for independent samples. RESULTS: In the AFIP group, there was no significant difference between the medial and lateral gap laxity in extension (NS). A significant opening of the lateral gap was observed in flexion compared to extension (mean: + 2.9 mm; p < 0.0001). The mean postoperative HKA angle was comparable between both groups (177.3° ± 2.1 in the AFIP group vs 176.8° ± 3.2; NS). In the AFIP group, the femoral anatomy was restored (90.9° ± 1.6) and the tibial varus was partially corrected (87.4° ± 1.8). The improvement of Knee and Function KSS at 6 months was better in the AFIP group (59.3 ± 11.9 and 51.7 ± 20, respectively, versus 49.3 ± 9.7 and 20.8 ± 13; p < 0.001). CONCLUSION: The AFIP concept allowed the restoration of the native knee alignment and a natural functional ligament pattern. With a more physiological target for ligament balancing, the AFIP technique had equivalent clinical outcomes at 12 months compared to aMA, with a faster recovery. LEVEL OF EVIDENCE: III retrospective therapeutic case control series.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Ligamentos/cirurgia , Amplitude de Movimento Articular/fisiologia
13.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1470-1476, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36538057

RESUMO

BACKGROUND: Literature regarding outcomes in patients over 80 years old after total knee arthroplasty (TKA) is inconsistent. We aimed to compare implant survivorship and functional outcomes between elderly patients (≥ 80 years) and younger patients (< 80 years) following TKA, using a single modern posterior-stabilized (PS) prosthetic design. METHODS: This is a retrospective cohort study of 80 patients over 80 years old who underwent TKA between January 2015 and December 2016, who were compared with younger patients (60-75 years old) operated during the same period. Patients were matched with a ratio of 1:3 based on logistic regression analysis of gender and body mass index. All patients received the same cemented PS prosthesis with a fixed bearing polyethylene insert, with or without patellar resurfacing. Implant survival and patient-reported outcome measurements were compared between the two groups. At last follow-up, data were available for 41 knees in the elderly group (including 17 patients who died before 5-year follow-up) and 123 knees in the younger group. RESULTS: Functional results were better at final follow-up in the group < 80 years with a significantly higher Knee Society Function Subscore (88.6 ± 16.9 vs 79.4 ± 22.1, p < 0.01), but no significant differences in Knee Subscore and global Knee Society Score (p > 0.05), nor regarding maximum flexion (121° ± 12 and 117° ± 13, p = 0.08). The implant survivorship was 100.0% after a mean 64.4-month follow-up (range 60-78), without revision requiring removal of the implant in any group. The survival rate without any reoperation was 97.6% (95% CI 93.0-100.0) in the elderly group and 95.9% (95% CI 92.5-99.5) in the younger group (p = 0.64). CONCLUSION: At a minimum of 5-year follow-up, there was no revision surgery and a very low rate of complications requiring reoperations both in the group over 80 years of age and in the younger population, with the use of a PS prosthesis. The functional results were slightly lower for elderly patients and correlate with the lower functional demands of this population. The indication for TKA, especially with a PS implant, may be encouraged in appropriately selected elderly patients. LEVEL OF EVIDENCE: III (retrospective cohort study).


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Idoso , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Seguimentos , Estudos Retrospectivos , Taxa de Sobrevida , Articulação do Joelho/cirurgia , Reoperação , Desenho de Prótese , Resultado do Tratamento
14.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5591-5602, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37851026

RESUMO

PURPOSE: Few comparative studies assessed the current concept of individualised alignment for total knee arthroplasty (TKA) and their outcomes at mid-term. This study aimed to evaluate the functional outcomes at 1 year of primary TKA performed with a functional positioning technique based on an image-based robotic-assisted system, compared to conventional TKA performed with a restricted kinematic alignment technique. METHODS: This retrospective comparative study included 100 primary TKAs performed with functional positioning principles using an image-based robotic-assisted system. A control group included 100 primary TKAs with the same posterior-stabilised implant as the robotic group but performed with manual instrumentation and restricted kinematic alignment technique. In the robotic group, the mean age was 69.2 years old ± 7.9; the mean body mass index was 29.7 kg/m2 ± 4.6. The demographic characteristics were similar between both groups. Kujala score, Forgotten Joint Score (FJS), Knee Society Score (KSS) knee and KSS function were collected 12 months postoperatively. Normally distributed continuous variables were compared using the Student t test. For non-normally distributed continuous variables, the Mann-Whitney test was used. RESULTS: FJS was significantly higher in the robotic group (76.3 ± 13 vs. 68.6 ± 16.9 in the conventional group; p = 0.026). At a 1-year follow-up, there was no significant difference in the KSS knee and KSS function scores and the Kujala score between both groups. The mean KSS knee score was 90.8 ± 11.4 in the robotic group versus 89.4 ± 9.6 in the conventional group (p = 0.082). The mean KSS function score was 91.4 ± 12.3 versus 91.3 ± 12.6, respectively (p = 0.778). CONCLUSION: Functional positioning principles using an image-based robotic-assisted system achieved a higher Forgotten Joint Score 1 year after TKA compared to restricted kinematic alignment. Personalised alignment and implant positioning are interesting paths to improve the functional outcomes after TKA. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Idoso , Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Fenômenos Biomecânicos , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia
15.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5398-5406, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37752347

RESUMO

PURPOSE: Surgeons want to achieve native kinematics in primary total knee arthroplasty (TKA). Cruciate-substituting (CS) implants could restore the knee kinematics more efficiently than posterior-stabilised (PS) TKA. This study aimed to compare gait patterns in patients with CS or PS TKA at 6 months. The hypothesis was that CS implants would demonstrate comparable gait parameters to PS implants at 6 months. METHODS: In this prospective case-control study, 38 primary TKA without coronal laxity were divided into 2 groups: 19 cruciate-substituting (CS) and 19 posterior-stabilised (PS) implants. The type of prosthesis was determined according to the surgical period. Exclusion criteria were TKA revision, associated procedures and inability to walk on a treadmill. Gait analysis was conducted on a treadmill 6 months postoperatively for each patient with a knee assessment device (KneeKG®). Gait characteristics included analysis in three spatial dimensions (flexion-extension, abduction-adduction, internal-external rotation, anterior-posterior translation). Clinical outcomes (Knee Society Score and Forgotten Joint Score) were compared between both groups at 6 months postoperatively. RESULTS: At 6 months, the gait analysis did not demonstrate any significant difference between CS and PS implants. The range and the maximum anteroposterior translation were similar in both groups (9.2 ± 6.5 mm in CS group vs. 8.1 ± 3 mm in PS group (n.s.); and - 5.2 ± 5 mm in CS group vs. - 6.3 ± 5.9 mm in PS group (n.s.), respectively). The internal/external rotation, the flexion, and the varus angle were similar between CS and PS implants. The KSS Knee score was higher at 6 months in the CS group than in the PS group (92.1 ± 5.6 vs. 84.8 ± 8.9 (p < 0.01)). CONCLUSION: Cruciate-substituting and posterior-stabilised TKA had similar gait patterns at 6 months postoperatively, despite a non-equivalent posterior stabilisation system. CS prostheses were an interesting option for primary TKA for knee kinematics restoration without requiring a femoral box. LEVEL OF EVIDENCE: Prospective, case-control study; Level II.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Ligamento Cruzado Posterior , Humanos , Artroplastia do Joelho/métodos , Ligamento Cruzado Posterior/cirurgia , Estudos de Casos e Controles , Desenho de Prótese , Articulação do Joelho/cirurgia , Marcha , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Osteoartrite do Joelho/cirurgia
16.
J Arthroplasty ; 38(11): 2275-2281, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37271228

RESUMO

BACKGROUND: Outliers in implant positioning, malalignment, and joint line height change are risk factors for unicompartmental knee arthroplasty (UKA) failure. However, their relationships and patterns in large datasets remain unexplored. This study assessed medial UKA survival in a large cohort and explored associated risk factors. METHODS: This was a retrospective cohort study on medial UKA patients (2011 to 2019). Radiological outcomes included tibial implant positioning in the coronal plane, posterior tibial slope, residual knee deformity, and joint line restitution. Survival rate at last follow-up was recorded. Multinomial logistic regression analyzed risk factors, incorporating demographic and univariate analysis data. RESULTS: Three hundred and sixty-six knees met inclusion criteria, with 10 lost to follow-up (2.7%). Mean follow-up was 61.3 months [24.1 to 135.1]. 5- and 10-year implant survival rates were 92% ± 1.6 and 88.4% ± 3.8, respectively. Multivariate analysis identified post-operative hip-knee-ankle angle (HKA) ≤ 175° (OR = 5.30 [1.64 to 17.13], P = .005) and joint line lowering ≥2 mm (OR = 8.86 [2.06 to 38.06]) as significant risk factors for tibial implant failure. Their combination carried a significantly high risk of failure (OR = 10.3 [3.1 to 34.3]). Post-operative HKA < 175° was common in knees with pre-operative HKA < 172°. CONCLUSION: This study reports encouraging 5- and 10-year survival outcomes for medial UKA. Tibial loosening was the main reason for revision. Patients with joint line lowering ≥ 2 mm and post-operative HKA ≤ 175° were at high risk of tibial implant failure. Surgeons should carefully restore the joint line in cases of pre-operative HKA < 172°.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Articulação do Joelho/cirurgia , Tíbia/cirurgia
17.
Int Orthop ; 47(2): 533-541, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36434294

RESUMO

PURPOSE: Implant malpositioning, joint line (JL) lowering, and malalignment have been identified as risk factors for implant failure in unicompartmental knee arthroplasty (UKA). The aims of this study were to compare the accuracy of implant positioning in robotic-assisted UKA versus conventional UKA in a large cohort and examine the correlation with implant survival at mid-term follow-up. METHODS: This retrospective study included 356 medial UKAs from 2011 to 2019. The radiological measurements performed were coronal positioning of tibial implant according to Cartier angle (Δ Cartier), posterior tibial slope (PTS), residual hip-knee-ankle (HKA), and JL restoration. Outliers were defined as follows: post-operative HKA < 175° or > 180°, Δ Cartier > 3° or < - 3°, JL change ≥ 2 mm, and PTS < 2° or > 8°. The survival probability was reported at the last follow-up. RESULTS: Out of the 356 knees included, 159 underwent conventional UKA (44.5%) and 197 (55.5%) robotic-assisted UKA. The mean follow-up was 61.3 months ± 24.0. Robotic UKA was associated with better accuracy compared to conventional UKA in relation to HKA (67% vs 56%, p = 0.023), JL restoration (70% vs 44%, p < 0.0001), PTS (83% vs 55%, p < 0.0001), and tibial varus restoration (65% vs 55%, p = 0.049). Implant survival in the robotic group was found to be superior at the last follow-up (96.4% versus 87.3% at 9 years, p = 0.004). CONCLUSION: Robotic assistance in patients undergoing medial UKA was associated with better accuracy compared to conventional UKA with respect to tibial implant positioning, post-operative limb alignment, and JL restoration. This was translated in improved survival at mid-term follow-up favouring the robotic group.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Seguimentos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Extremidade Inferior/cirurgia , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento
18.
Int Orthop ; 47(2): 329-341, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36112197

RESUMO

PURPOSE: The ability of kinematic alignment (KA) to consistently restore trochlea anatomy in total knee arthroplasty (TKA) is unknown despite recreation of constitutional anatomy being its rationale for use. The purpose of this study was to assess if alignment choice in TKA effects the ability to restore the native trochlea groove. METHODS: One hundred and twenty-two consecutive patients undergoing robotic-assisted TKA using the MAKO image-based robotic platform had simulated femoral components placed according to kinematic, mechanical and functional alignment principals. Implant position and trochlea restoration between groups were compared. Restoration was assessed by shift (medial-lateral) and depth relative to the native groove from three consistent points; full extension (0°), mid-flexion (30°-40°) and deep flexion (70°-80°). RESULTS: Three hundred and sixty-six alignment options were analysed. Femoral alignment was significantly different between groups. Of KA, 13.1% compared to 3.3% of FA plans were outside safe coronal boundaries. The trochlear groove was translated the most by MA compared to KA and FA (full extension, MA 7.84 ± 1.99 mm lateral to the native groove, KA 6.40 ± 2.43 mm and FA 6.88 ± 1.74 mm, p ≤ 0.001). In full extension, FA most closely restored the trochlear groove depth in all three positions of flexion. CONCLUSION: Alignment philosophy led to significant differences in trochlea groove recreation. A kinematically placed femoral component led to positioning considered unsafe in over 13% of cases. A functionally placed femoral component most closely restored trochlea depth in all three positions of flexion.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Articulação do Joelho/cirurgia , Fêmur/cirurgia , Fenômenos Biomecânicos , Recreação , Osteoartrite do Joelho/cirurgia
19.
Int Orthop ; 47(2): 437-446, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36355082

RESUMO

INTRODUCTION: Robotically assisted total knee arthroplasty (RA-TKA) is an emerging surgical tool. The purpose of this study was to analyze the length of time taken to perform the key steps of a RA-TKA for a surgeon and centre new to the MAKO robotic system. METHOD: This was a prospective cohort study of the first 50 patients undergoing TKA using a robotic platform (Mako, Stryker, Kalamazoo, MI, USA) performed by a single surgeon. Each key surgical step was recorded. The first 50 patients were chronologically allocated into five groups of ten and compared. RESULTS: Mean operation length was 59.4 ± 7.4 min with significant improvement after 30 cases. A significant effect on certain steps of the surgery also occurred over 50 cases: after 30 cases for pre-operative planning (3.8 min in group 1 versus 1.2 min in group 4, p < 0.005), ten cases for registration time (5.2 min in group 1 versus 3.8 in group 2, p = 0.039) and ten cases for tibial cutting time (1.6 min in group 1 versus 1.3 in group 2, p < 0.005). Nurse setup, femur cutting, and intraoperative planning did not demonstrate a significant improvement in time over 50 cases. CONCLUSION: A significant decrease in total operating length occurred after the 30th case. Anatomical registration and tibial cutting time demonstrated the largest improvements. MAKO image-based robotically assisted TKA is not a time-intensive intervention for both the surgeon and scrub nursing staff, and significant improvements in total surgical time occurs early in the learning phase.


Assuntos
Artroplastia do Joelho , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Prospectivos
20.
Int Orthop ; 47(4): 963-971, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35962232

RESUMO

PURPOSE: Anterior cruciate ligament (ACL) deficiency can be a consequence or a cause of femoro-tibial osteoarthritis (OA). Several studies have published satisfactory outcomes of unicompartimental knee arthroplasty (UKA) and combined ACL reconstruction despite its absence classically being considered a contraindication. A major challenge in the ACL deficient knee is obtaining appropriate gap balancing and limb axis. Robotically assisted UKA allows for precise control of these factors; however, it's utilisation as a tool with combined ACL reconstruction and UKA has not been described. The purpose of this study was to evaluate the clinical and radiological outcomes of robotically assisted UKA with combined ACL reconstruction. METHODS: This was a retrospective single-centre study of ten patients operated by a single surgeon from 2016 to 2020. All surgery was performed using a cemented fixed bearing UKA prosthesis (Journey uni, Smith and Nephew®) (8 medial, 2 lateral) inserted with the assistance of an image-free robotic-assisted system (BlueBelt, Navio, Smith and Nephew®). All ACL reconstructions were performed using hamstring autograft. Clinical assessment included International Knee Score (IKS) score, Tegner score and patient satisfaction. Radiological assessment was performed to assess radiolucent lines, progression of OA in the other compartments, Hip-Knee-Ankle angle and Posterior Tibial Slope. RESULTS: There were eight females (80%), mean age was 57 ± 7 [48-70], mean BMI was 26 ± 3 [22-31]. The mean follow-up was 45 months ± 13 months [24-66]. Mean post-operative IKS knee and function score were respectively 96 ± 4.5 [88-100] and 93 ± 8.2 [74-100], mean Tegner score was 4.5 ± 1.4 [3-6]. Nine patients (90%) returned to sport; one patient (10%) was dissatisfied because of residual pain preventing a return to a desired level of sport. 100% of the radiological objectives were achieved. No radiolucent lines were seen at the last follow-up. There were two re-operations (20%) for stiffness requiring arthroscopic arthrolysis at two and three months respectively following surgery, with full recovery of the flexion at the last follow-up in both cases. No other complications were observed. CONCLUSION: Robotic UKA associated with ACL reconstruction provides satisfactory early patient outcomes and accurate implant positioning. The first results in terms of return to sports were promising.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Feminino , Humanos , Pessoa de Meia-Idade , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Estudos Retrospectivos , Lesões do Ligamento Cruzado Anterior/cirurgia , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/complicações , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Reconstrução do Ligamento Cruzado Anterior/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA