Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Clin Invest ; 54(6): e14176, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38339827

RESUMO

BACKGROUND: Classical pulmonary thromboembolism (TE) and local pulmonary thrombosis (PT) have been suggested as mechanisms of thrombosis in COVID-19. However, robust evidence is still lacking because this was mainly based on retrospective studies, in which patients were included when TE was suspected. METHODS: All patients with COVID-19 pneumonia underwent computed tomography and pulmonary angiography in a prospective study. The main objective was to determine the number and percentage of thrombi surrounded by lung opacification (TSO) in each patient, as well as their relationship with percentage of lung involvement (TLI), to distinguish classical TE (with a random location of thrombi that should correspond to a percentage of TSO equivalent to the TLI) from PT. We determined TLI by artificial intelligence. Analyses at patient level (TLI and percentage of TSO) and at thrombi level (TLI and TSO) were performed. RESULTS: We diagnosed TE in 70 out of 184 patients. Three (2-8) thrombi/patient were detected. The percentage of TSO was 100% (75-100) per patient, and TLI was 19.9% (4.6-35.2). Sixty-five patients (92.9%) were above the random scenario with higher percentage of TSO than TLI. Most thrombi were TSO (n = 299, 75.1%). When evaluating by TLI (<10%, 10%-20%, 20%-30% and >30%), percentage of TSO was higher in most groups. Thrombi were mainly in subsegmental/segmental arteries, and percentage of TSO was higher in all locations. CONCLUSIONS: Thrombi in COVID-19 were found within lung opacities in a higher percentage than lung involvement, regardless of TLI and clot location, supporting the hypothesis of local PT rather than "classic TE".


Assuntos
COVID-19 , Embolia Pulmonar , Tomografia Computadorizada por Raios X , Humanos , COVID-19/complicações , COVID-19/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Pulmão/diagnóstico por imagem , SARS-CoV-2 , Angiografia por Tomografia Computadorizada , Idoso de 80 Anos ou mais , Adulto , Trombose/diagnóstico por imagem
2.
Clin Chem Lab Med ; 60(1): 66-73, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-34670030

RESUMO

OBJECTIVES: Serum indices included in clinical chemistry instruments are widely used by laboratories to assess the quality of samples. Instruments that report quantitative results allow an evaluation of their diagnostic performance in a similar way to other biochemical tests. The Spanish Society of Laboratory Medicine (SEQC-ML) launched a monthly External Quality program of serum indices in 2018 using three lyophilized materials of simultaneous annual distribution. We present the results of the first three years of the program. METHODS: The use of four different quality control materials with different concentrations in three alternate months allows an annual evaluation of the participant's accuracy. Assigned values are established by consensus among homogeneous groups, considering necessary at least 10 participants for a comparison at instrument level. The average percentage difference results per instrument allow the assessment of bias among groups. RESULTS: The imprecision of the three indices ranges between 3 and 9%, with no major differences among instruments. Significant differences were observed in all indices among instruments with more than 10 participants (Roche Cobas, Abbott Architect, Abbott Alinity and Siemens Advia). The 90th percentile of the distribution of percentage differences was used as the analytical performance specification (APS). An improvement in performance was observed in the first three years of the program, probably due to the learning curve effect. In 2020, APS of 7.8, 12.2 and 9.7% were proposed for hemolytic, icteric and lipemic indices, respectively. CONCLUSIONS: Serum indices have a great impact on the quality and the reliability of laboratory test results. Participation in proficiency testing programs for serum indices is helpful to encourage harmonization among providers and laboratories.


Assuntos
Laboratórios , Ensaio de Proficiência Laboratorial , Humanos , Controle de Qualidade , Reprodutibilidade dos Testes , Soro
3.
J Pediatr Gastroenterol Nutr ; 75(5): e98-e105, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35930026

RESUMO

OBJECTIVES: High manganese (Mn) levels during fetal growth or prolonged parenteral nutrition (PN) may have adverse effects on neurodevelopment. We aim to report on Mn levels and their short-term impact on clinical course in very low birth weight infants. METHODS: An observational study including newborns with a gestational age (GA) ≤32 weeks and/or ≤1500 g of birth weight (BW). Newborns received intravenous supplementation of Mn at 1 µg/kg/day (Peditrace ® ) in PN and continued with fortified breast milk. Mothers answered surveys about dietary and other habits and blood levels of Mn in newborns were analyzed at days 1, 15, and 30 of life. Associations of Mn levels with mothers' and newborns' data were evaluated and adjusted for multiple comparisons. RESULTS: One hundred and sixty premature infants were recruited. Median blood Mn levels at birth were 43.0 and 24.5 µg/L at day 30. No important association with mothers' data was found. Median [interquartile range (IQR)] duration of PN was 8 days (7-14). A prolonged PN and late oral feeding showed a nonsignificant association with lower blood Mn levels at day 30 ( P = 0.010, P threshold 0.003). Mn levels at day 15 and 30 were associated with increasing GA ( P < 0.001). Low Mn was not a significant predictor of adverse outcomes such as retinopathy of prematurity, bronchopulmonary dysplasia, or respiratory distress syndrome after adjusting for potential confounders and multiple testing. CONCLUSIONS: Mn showed lower levels with decreasing GA and prolonged PN. Using a low Mn PN solution may not raise blood Mn levels in premature infants.


Assuntos
Doenças do Prematuro , Manganês , Lactente , Feminino , Recém-Nascido , Humanos , Recém-Nascido de muito Baixo Peso , Recém-Nascido Prematuro , Nutrição Parenteral/efeitos adversos , Idade Gestacional , Doenças do Prematuro/etiologia , Peso ao Nascer
4.
Crit Rev Clin Lab Sci ; 58(5): 329-353, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33538219

RESUMO

In laboratory medicine, much effort has been put into analytical quality in the past decades, making this medical profession one of the most standardized with the lowest rates of error. However, even the best analytical quality cannot compensate for errors or low quality in the pre or postanalytical phase of the total testing process. Guidelines for data reporting focus solely on defined data elements, which have to be provided alongside the analytical test results. No guidelines on how to format laboratory reports exist. The habit of reporting as much diagnostic data as possible, including supplemental information, may lead to an information overload. Considering the multiple tasks physicians have to do simultaneously, unfiltered data presentation may contribute to patient risk, as important information may be overlooked, or juxtaposition errors may occur. As laboratories should aim to answer clinical questions, rather than providing sole analytical results, optimizing formatting options may help improve the effectiveness and efficiency of medical decision-making. In this narrative review, we focus on the underappreciated topic of laboratory result reporting. We present published literature, focusing on the impact of laboratory result report formatting on medical decisions as well as approaches, potential benefits, and limitations for alternative report formats. We discuss influencing variables such as, for example, the type of patient (e.g. acute versus chronic), the medical specialty of the recipient of the report, the display of reference intervals, the medium or platform on which the laboratory report is presented (printed paper, within electronic health record systems, on handheld devices, etc.), the context in which the report is viewed in, and difficulties in formatting single versus cumulative reports. Evidence on this topic, especially experimental studies, is scarce. When considering the medical impact, it is of utmost importance that laboratories focus not only on the analytical aspects but on the total testing process. The achievement of high analytical quality may be of minor value if essential results get lost in overload or scattering of information by using a non-formatted tabular design. More experimental studies to define guidelines and to standardize effective and efficient reporting are most definitely needed.


Assuntos
Química Clínica , Medicina , Humanos , Laboratórios , Relatório de Pesquisa
5.
Eur J Clin Invest ; 51(6): e13532, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33660278

RESUMO

BACKGROUND: Myocardial injury is a common finding in COVID-19 strongly associated with severity. We analysed the prevalence and prognostic utility of myocardial injury, characterized by elevated cardiac troponin, in a large population of COVID-19 patients, and further evaluated separately the role of troponin T and I. METHODS: This is a multicentre, retrospective observational study enrolling patients with laboratory-confirmed COVID-19 who were hospitalized in 32 Spanish hospitals. Elevated troponin levels were defined as values above the sex-specific 99th percentile upper reference limit, as recommended by international guidelines. Thirty-day mortality was defined as endpoint. RESULTS: A total of 1280 COVID-19 patients were included in this study, of whom 187 (14.6%) died during the hospitalization. Using a nonspecific sex cut-off, elevated troponin levels were found in 344 patients (26.9%), increasing to 384 (30.0%) when a sex-specific cut-off was used. This prevalence was significantly higher (42.9% vs 21.9%; P < .001) in patients in whom troponin T was measured in comparison with troponin I. Sex-specific elevated troponin levels were significantly associated with 30-day mortality, with adjusted odds ratios (ORs) of 3.00 for total population, 3.20 for cardiac troponin T and 3.69 for cardiac troponin I. CONCLUSION: In this multicentre study, myocardial injury was a common finding in COVID-19 patients. Its prevalence increased when a sex-specific cut-off and cardiac troponin T were used. Elevated troponin was an independent predictor of 30-day mortality, irrespective of cardiac troponin assay and cut-offs to detect myocardial injury. Hence, the early measurement of cardiac troponin may be useful for risk stratification in COVID-19.


Assuntos
COVID-19/sangue , Cardiomiopatias/sangue , Mortalidade , Troponina I/sangue , Troponina T/sangue , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Prognóstico , Estudos Retrospectivos , SARS-CoV-2 , Índice de Gravidade de Doença
6.
Scand J Clin Lab Invest ; 81(3): 187-193, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33591234

RESUMO

Identification of predictors for severe disease progression is key for risk stratification in COVID-19 patients. We aimed to describe the main characteristics and identify the early predictors for severe outcomes among hospitalized patients with COVID-19 in Spain. This was an observational, retrospective cohort study (BIOCOVID-Spain study) including COVID-19 patients admitted to 32 Spanish hospitals. Demographics, comorbidities and laboratory tests were collected. Outcome was in-hospital mortality. For analysis, laboratory tests values were previously adjusted to assure the comparability of results among participants. Cox regression was performed to identify predictors. Study population included 2873 hospitalized COVID-19 patients. Nine variables were independent predictors for in-hospital mortality, including creatinine (Hazard ratio [HR]:1.327; 95% Confidence Interval [CI]: 1.040-1.695, p = .023), troponin (HR: 2.150; 95% CI: 1.155-4.001; p = .016), platelet count (HR: 0.994; 95% CI: 0.989-0.998; p = .004) and C-reactive protein (HR: 1.037; 95% CI: 1.006-1.068; p = .019). This is the first multicenter study in which an effort was carried out to adjust the results of laboratory tests measured with different methodologies to guarantee their comparability. We reported a comprehensive information about characteristics in a large cohort of hospitalized COVID-19 patients, focusing on the analytical features. Our findings may help to identify patients early at a higher risk for an adverse outcome.


Assuntos
COVID-19/diagnóstico , Serviço Hospitalar de Emergência , SARS-CoV-2 , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/mortalidade , Feminino , Mortalidade Hospitalar , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Espanha/epidemiologia , Adulto Jovem
7.
Clin Chem Lab Med ; 59(1): 71-77, 2020 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-32628627

RESUMO

Objectives: Young laboratory medicine professionals (YLMPs) are the future of clinical laboratories. Although everyday practice shows significant differences among countries, especially during residency training, most of them face the same challenges. Besides promoting scientific, professional and clinical aspects of laboratory medicine in Europe, the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) should take into consideration YLMPs' concerns and interests to help them achieve excellence. The aim of this survey was to assess the opinion and expectations of YLMPs about their involvement in the activities of EFLM. Methods: An online survey was distributed to YLMPs in Europe through different channels. The questionnaire consisted of 21 items grouped into five sections: demographic questions, opinion about the current status of YLMPs within EFLM, YLMPs network, suggestions and opportunities, and scientific training and exchange. Where appropriate, responses from residents and specialists were compared. Results: A total of 329 valid responses were obtained from 53 different countries. Countries with the highest number of participants were Spain, Turkey, Croatia and Romania. A significant percentage would like to know more about EFLM and their activities (86%) and wish EFLM promoted networking and scientific exchanges (95%), for instance by means of a European YLMPs network (93%). EFLMLabX project was widely unknown (75%). Conclusions: YLMPs demand better connection to share concerns about daily healthcare duties, to keep updated and to advance professionally. EFLM needs to improve their advertising through national societies to increase YLMPs' participation. In addition to international meetings and congresses, respondents have emphasized that workshops and other small group activities would significantly help promote laboratory medicine practice in Europe.


Assuntos
Química Clínica/estatística & dados numéricos , Pessoal de Laboratório Médico/estatística & dados numéricos , Ciência de Laboratório Médico/estatística & dados numéricos , Inquéritos e Questionários , Adulto , Atitude do Pessoal de Saúde , Europa (Continente) , Humanos , Internet , Pessoal de Laboratório Médico/psicologia , Motivação , Rede Social , Adulto Jovem
8.
Clin Chem Lab Med ; 57(12): 1829-1836, 2019 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-31348756

RESUMO

Stability of a measurand in a specimen is a function of the property variation over time in specific storage conditions, which can be expressed as a stability equation, and is usually simplified to stability limits (SLs). Stability studies show differences or even inconsistent results due to the lack of standardized experimental designs and heterogeneity of the chosen specifications. Although guidelines for the validation of sample collection tubes have been published recently, the measurand stability evaluation is not addressed. This document provides an easy guideline for the development of a stability test protocol based on a two-step process. A preliminary test is proposed to evaluate the stability under laboratory habitual conditions. The loss of stability is assessed by comparing measurement values of two samples obtained from the same patient and analyzed at different time points. One of them is analyzed under optimal conditions (basal sample). The other is stored under specific stability conditions for a time set by the laboratory (test sample). Differences are expressed using percentage deviation (PD%) to facilitate comparison with specifications. When the preliminary test demonstrates instability, a comprehensive test is proposed in order to define the stability equation and to specify SLs. Several samples are collected from a set of patients. The basal sample is analyzed under optimal conditions, whereas analysis of test samples is delayed at time intervals. For each patient PD% is calculated as the difference between measurements for every test sample and its basal one and represented in a coordinate graph versus time.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Manejo de Espécimes/normas , Coleta de Urina/métodos , Humanos , Laboratórios , Manejo de Espécimes/métodos , Fatores de Tempo , Coleta de Urina/normas
9.
Clin Chem Lab Med ; 56(11): 1806-1818, 2018 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-29729140

RESUMO

BACKGROUND: The stability limit of an analyte in a biological sample can be defined as the time required until a measured property acquires a bias higher than a defined specification. Many studies assessing stability and presenting recommendations of stability limits are available, but differences among them are frequent. The aim of this study was to classify and to grade a set of bibliographic studies on the stability of five common blood measurands and subsequently generate a consensus stability function. METHODS: First, a bibliographic search was made for stability studies for five analytes in blood: alanine aminotransferase (ALT), glucose, phosphorus, potassium and prostate specific antigen (PSA). The quality of every study was evaluated using an in-house grading tool. Second, the different conditions of stability were uniformly defined and the percent deviation (PD%) over time for each analyte and condition were scattered while unifying studies with similar conditions. RESULTS: From the 37 articles considered as valid, up to 130 experiments were evaluated and 629 PD% data were included (106 for ALT, 180 for glucose, 113 for phosphorus, 145 for potassium and 85 for PSA). Consensus stability equations were established for glucose, potassium, phosphorus and PSA, but not for ALT. CONCLUSIONS: Time is the main variable affecting stability in medical laboratory samples. Bibliographic studies differ in recommedations of stability limits mainly because of different specifications for maximum allowable error. Definition of a consensus stability function in specific conditions can help laboratories define stability limits using their own quality specifications.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Alanina Transaminase/sangue , Glicemia/química , Humanos , Fósforo/sangue , Potássio/sangue , Fase Pré-Analítica , Antígeno Prostático Específico/sangue , Estabilidade Proteica , Temperatura
10.
Clin Chem Lab Med ; 55(4): 530-538, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27658151

RESUMO

BACKGROUND: Preanalytical variables, such as sample collection, handling and transport, may affect patient results. Preanalytical phase quality monitoring should be established in order to minimize laboratory errors and improve patient safety. METHODS: A retrospective study (2001-2013) of the results obtained through the Spanish Society of Clinical Biochemistry and Molecular Pathology (SEQC) External quality assessment (preanalytical phase) was performed to summarize data regarding the main factors affecting preanalytical phase quality. Our aim was to compare data from 2006 to 2013 with a previously published manuscript assessing the 2001-2005 period. RESULTS: A significant decrease in rejection rates was observed both for blood and urine samples. For serum samples, the most frequent rejection causes in the first period were non-received samples (37.5%), hemolysis (29.3%) and clotted samples (14.4%). Conversely, in the second period, hemolysis was the main rejection cause (36.2%), followed by non-received samples (34.5%) and clotted samples (11.1%). For urine samples, the main rejection cause overall was a non-received sample (up to 86.1% of cases in the second period, and 81.6% in the first). For blood samples with anticoagulant, the number of rejections also decreased. While plasma-citrate-ESR still showed the highest percentages of rejections (0.980% vs. 1.473%, p<0.001), the lowest corresponded to whole-blood EDTA (0.296% vs. 0.381%, p<0.001). CONCLUSIONS: For the majority of sample types, a decrease in preanalytical errors was confirmed. Improvements in organization, implementation of standardized procedures in the preanalytical phase, and participation in a Spanish external quality assessment scheme may have notably contributed to error reduction in this phase.


Assuntos
Técnicas de Laboratório Clínico/normas , Controle de Qualidade , Manejo de Espécimes/normas , Coleta de Amostras Sanguíneas/normas , Hemólise , Humanos , Laboratórios/normas , Ensaio de Proficiência Laboratorial/métodos , Estudos Retrospectivos , Espanha , Urinálise/normas
11.
Cancer Immunol Immunother ; 64(10): 1261-70, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26122358

RESUMO

BACKGROUND: Chronic obstructive pulmonary disease (COPD) is a risk factor for lung cancer (LC). Myeloid-derived suppressor cells (MDSCs) down-regulate the T cell receptor ζ chain (TCR ζ) through L-arginine deprivation and lead to T cell dysfunction and deficient antitumor immunity. We hypothesized that abnormally high levels of MDSCs in COPD patients may alter tumor immunosurveillance. METHODS: We compared the proportion of circulating MDSCs (Lin-HLA-DR-/CD33+/CD11b+) (by flow cytometry), arginase I (ARG I) serum levels (by ELISA), and expression levels of TCR ζ on circulating lymphocytes (by flow cytometry) in 28 patients with LC, 62 subjects with COPD, 41 patients with both LC and COPD, 40 smokers with normal spirometry and 33 non-smoking controls. T cell proliferation assays were performed in a subgroup of participants (CFSE dilution protocol). RESULTS: We found that: (1) circulating MDSCs were up-regulated in COPD and LC patients (with and without COPD); (2) MDSCs expansion was associated with TCR ζ down-regulation in the three groups; (3) in LC patients, these findings were independent of COPD and tobacco smoking exposure; (4) TCR ζ down-regulation correlates with T cell hyporesponsiveness in COPD and LC patients. CONCLUSIONS: These results suggest that tumor immunosurveillance might be impaired in COPD and may contribute to the increased risk of LC reported in these patients.


Assuntos
Carcinoma Broncogênico/imunologia , Neoplasias Pulmonares/imunologia , Células Mieloides/imunologia , Doença Pulmonar Obstrutiva Crônica/imunologia , Linfócitos T/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Arginase/sangue , Carcinoma Broncogênico/patologia , Proliferação de Células , Células Cultivadas , Feminino , Humanos , Inflamação/imunologia , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Monitorização Imunológica , Estadiamento de Neoplasias , Doença Pulmonar Obstrutiva Crônica/patologia , Receptores de Antígenos de Linfócitos T/metabolismo , Fumar/efeitos adversos
13.
Clin Chem ; 60(8): 1052-61, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24212086

RESUMO

BACKGROUND: Cancer is a leading cause of death worldwide. The low diagnostic sensitivity and specificity of most current cancer biomarkers make early cancer diagnosis a challenging task. The comprehensive study of peptides and small proteins in a living system, known as "peptidomics," represents an alternative technological approach to the discovery of potential biomarkers for the assessment of a wide variety of pathologies. This review examines the current status of peptidomics for several body fluids, with a focus on urine, for cancer diagnostics applications. CONTENT: Several studies have used high-throughput technologies to characterize the peptide content of different body fluids. Because of its noninvasive collection and high stability, urine is a valuable source of candidate cancer biomarkers. A wide variety of preanalytical issues concerning patient selection and sample handling need to be considered, because not doing so can affect the quality of the results by introducing bias and artifacts. Optimization of both the analytical strategies and the processing of bioinformatics data is also essential to minimize the false-discovery rate. SUMMARY: Peptidomics-based studies of urine and other body fluids have yielded a number of biomolecules and peptide panels with potential for diagnosing different types of cancer, especially of the ovary, prostate, and bladder. Large-scale studies are needed to validate these molecules as cancer biomarkers.


Assuntos
Biomarcadores Tumorais/análise , Líquidos Corporais/química , Neoplasias/diagnóstico , Peptídeos/análise , Proteômica , Biomarcadores Tumorais/urina , Humanos , Neoplasias/química , Neoplasias/urina , Peptídeos/urina
14.
Clin Proteomics ; 11(1): 23, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24982608

RESUMO

BACKGROUND: Ovarian cancer (OvCa) is the most lethal gynecological malignancy. The emergence of high-throughput technologies, such as mass spectrometry, has allowed for a paradigm shift in the way we search for novel biomarkers. Urine-based peptidomic profiling is a novel approach that may result in the discovery of noninvasive biomarkers for diagnosing patients with OvCa. In this study, the peptidome of urine from 6 ovarian cancer patients and 6 healthy controls was deciphered. RESULTS: Urine samples underwent ultrafiltration and the filtrate was subjected to solid phase extraction, followed by fractionation using strong cation exchange chromatography. These fractions were analyzed using an Orbitrap mass spectrometer. Over 4600 unique endogenous urine peptides arising from 713 proteins were catalogued, representing the largest urine peptidome reported to date. Each specimen was processed in triplicate and reproducibility at the protein (69-76%) and peptide (58-63%) levels were noted. More importantly, over 3100 unique peptides were detected solely in OvCa specimens. One such promising biomarker was leucine-rich alpha-2-glycoprotein (LRG1), where multiple peptides were found in all urines from OvCa patients, but only one peptide was found in one healthy control urine sample. CONCLUSIONS: Mining the urine peptidome may yield highly promising novel OvCa biomarkers.

16.
Respiration ; 86(4): 295-301, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23154407

RESUMO

BACKGROUND: Vitamin D insufficiency and high levels of parathyroid hormone (PTH) appear to be emerging risk factors for metabolic syndrome (MS), diabetes and cardiovascular disease, conditions that occur frequently in patients with obstructive sleep apnea syndrome (OSAS). OBJECTIVES: This study examined whether serum concentrations of 25-hydroxyvitamin D [25(OH)D] and PTH were associated with the presence of MS, diabetes and hypertension among an OSAS population. METHODS: A total of 826 patients (635 men and 191 women) with newly diagnosed OSAS were studied. The occurrence of the MS was analyzed according to the National Cholesterol Education Program Adult Treatment Panel III clinical criteria. Serum levels of 25(OH)D, PTH, glucose, triglycerides, cholesterol, HDL cholesterol, creatinine and uric acid were determined. RESULTS: In 55.3% of the men and in 63.2% of the women, the serum 25(OH)D level was less than 30 ng/ml (insufficient status). After adjusting for age, sex and seasonality, there was a significant trend of decreasing odds for diabetes [odds ratio (OR) 0.55, 95% confidence interval (CI) 0.33-0.94, ptrend = 0.038] and MS (OR 0.34, 95% CI 0.21-0.56, ptrend < 0.001) with increasing vitamin D levels. Higher PTH levels were associated with a higher prevalence of obesity (OR 2.05, 95% CI 1.06-3.09, ptrend < 0.001) and hypertension (OR 1.83, 95% CI 1.01-3.05, ptrend = 0.049). CONCLUSIONS: These data suggest an inverse association of 25(OH)D with diabetes and MS and a positive association of PTH with obesity and hypertension among patients with OSAS. Based on our observational study, the causative nature of the associations cannot be established. These findings require further examination in prospective studies including clinical trials.


Assuntos
Hormônio Paratireóideo/sangue , Apneia Obstrutiva do Sono/sangue , Vitamina D/sangue , Adulto , Idoso , Complicações do Diabetes/sangue , Complicações do Diabetes/epidemiologia , Feminino , Humanos , Hipertensão/sangue , Hipertensão/complicações , Hipertensão/epidemiologia , Masculino , Síndrome Metabólica/sangue , Síndrome Metabólica/complicações , Síndrome Metabólica/epidemiologia , Pessoa de Meia-Idade , Prevalência , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Espanha/epidemiologia
17.
Clin Chim Acta ; 544: 117334, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37031782

RESUMO

BACKGROUND-AIM: Most laboratory requests focus on the detection of possible vitamin B12 deficiency. In this context, methylmalonic acid (MMA) is reported as the best biomarker. The aim of our study was to establish the biological reference interval for MMA in urine, and assess the influence of age, sex, and vitamin B12 status on MMA concentrations. METHODS: This is a prospective observational study considering individuals with normal results for blood count and liver and kidney function. Individuals who presented supplementation, any pathology or treatment that could cause cobalamin metabolism disorders, and pregnant women were excluded. Likewise, individuals whose vitamin B12 result presented antibody-mediated interference were excluded. Individuals were grouped by age-group and sex. Reference intervals were determined by non-parametric calculation (percentiles 1-99). RESULTS: It was established a single reference interval [0.52 (CI90%: 0.50-0.54) - 5.75 (CI90%: 5.57-6.17) mmolMMA/mol creatinine], with 100 % of individuals with MMA above the upper limit of reference presenting a total vitamin B12 concentration ≤ 238 pmol/L. CONCLUSION: The establishment of optimal reference intervals for methylmalonic acid excretion in urine is crucial in individuals with a suspicion of functional vitamin B12 deficiency. However, the possibility of establishing a cut-off value for total vitamin B12 suggesting subclinical deficiency remains a challenge for this magnitude.


Assuntos
Ácido Metilmalônico , Deficiência de Vitamina B 12 , Humanos , Feminino , Gravidez , Deficiência de Vitamina B 12/diagnóstico , Vitamina B 12 , Biomarcadores , Estudos Prospectivos
18.
Clin Chim Acta ; 541: 117267, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36805891

RESUMO

BACKGROUND-AIM: High vitamin B12 concentrations are considered a common finding in clinical practice. Thanks to immunoassay accessibility, vitamin B12 has become a usual test in routine health checkups. However, these analytical methods usually present antibody-mediated interferences. Our aim was to propose an algorithm for the screening of antibody-mediated analytical interferences on vitamin B12 immunoassays on the Alinity platform. METHODS: Observational, prospective, case-control study was performed during 12 months. Individuals with persistently elevated cobalamin concentrations [>554 pmol/L] were considered as cases in the absence of supplementation or other justifying cause. Individuals under treatment with vitamin B12, or in the context of alcoholism were included as controls. A thorough interference study by macromolecules in immunoassays was performed in serum samples: PEG precipitation, rheumatoid factor, heterophile antibodies and gel permeation chromatography (GPC). Albumin, total B12, IgG and IgM were measured in every GPC collected fraction and chromatograms were drafted. RESULTS: Up to 45% of cases presented interference by B12-immunocomplexes and the precipitation for all of them was >50%. The individual with the lowest interfered vitamin B12 result was 661 pmol/L. CONCLUSION: The presence of antibody-mediated interferences, mainly B12-immunocomplexes, is a relatively common phenomenon. A simple algorithm for the screening of interferences is useful and reliable in ruling out healthy individuals and highly cost-effective.


Assuntos
Deficiência de Vitamina B 12 , Vitamina B 12 , Humanos , Estudos Prospectivos , Estudos de Casos e Controles , Anticorpos
19.
Adv Lab Med ; 3(2): 103-125, 2022 Jun.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37361868

RESUMO

Wilson's disease (WD) is an inherited disorder of copper metabolism caused by mutations in the ATP7B gene. This condition is characterized by the accumulation of copper in the liver and other organs and tissues causing hepatic and neuropsychiatric manifestations. This paper reviews the diagnostic performance and limitations of the biochemical tests commonly used to detect this underdiagnosed disease. It also provides some recommendations and suggests a set of standardized laboratory comments. At present, a rapid, simple, reliable biochemical test that confirms diagnosis of WD is not available. However, diagnosis can be established based on serum ceruloplasmin and urinary copper excretion. Total serum copper should be employed with caution, since it has a low negative predictive value. The use of estimated non-ceruloplasmin-bound copper is not recommended. Nevertheless, measured relative exchangeable copper has very high sensitivity and specificity and emerges as a potential gold standard for the biochemical diagnosis of WD. The development of novel assays for WD detection makes this disorder a potential candidate to be included in newborn screening programs.

20.
Adv Lab Med ; 3(2): 153-166, 2022 Jun.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37361866

RESUMO

Aluminum enters the body primarily through diet or occupational exposure, and is cleared through urine. However, this trace element may accumulate and cause toxicity in subjects with renal insufficiency, and even in dialysis patients. The mechanism of aluminum toxicity is related to increased oxidative and inflammatory stress, iron and calcium dyshomeostasis, or cholinergic dysregulation, among other. A review was conducted on the specimens and analytical methods used to determine aluminum in biological specimens and dialysis water. This paper describes the most relevant aspects related to quality assurance. This is a practical guideline for the development and implementation of a reliable method for determination of aluminum in the clinical laboratory. Serum aluminum is the main biomarker of toxicity. For cases of chronic exposure, urine testing is recommended. At present, inductively coupled plasma mass spectrometry (ICP-MS) is the gold-standard determination method, since it has been proven to have the best quantification limits, selectivity and robustness. Clear recommendations are provided in relation to the specimens used for aluminum determination. Relevant pre-analytical, analytical, and post-analytical considerations are also presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA