Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Spine J ; 33(4): 1607-1616, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38367026

RESUMO

PURPOSE: To evaluate feasibility, internal consistency, inter-rater reliability, and prospective validity of AO Spine CROST (Clinician Reported Outcome Spine Trauma) in the clinical setting. METHODS: Patients were included from four trauma centers. Two surgeons with substantial amount of experience in spine trauma care were included from each center. Two separate questionnaires were administered at baseline, 6-months and 1-year: one to surgeons (mainly CROST) and another to patients (AO Spine PROST-Patient Reported Outcome Spine Trauma). Descriptive statistics were used to analyze patient characteristics and feasibility, Cronbach's α for internal consistency. Inter-rater reliability through exact agreement, Kappa statistics and Intraclass Correlation Coefficient (ICC). Prospective analysis, and relationships between CROST and PROST were explored through descriptive statistics and Spearman correlations. RESULTS: In total, 92 patients were included. CROST showed excellent feasibility results. Internal consistency (α = 0.58-0.70) and reliability (ICC = 0.52 and 0.55) were moderate. Mean total scores between surgeons only differed 0.2-0.9 with exact agreement 48.9-57.6%. Exact agreement per CROST item showed good results (73.9-98.9%). Kappa statistics revealed moderate agreement for most CROST items. In the prospective analysis a trend was only seen when no concerns at all were expressed by the surgeon (CROST = 0), and moderate to strong positive Spearman correlations were found between CROST at baseline and the scores at follow-up (rs = 0.41-0.64). Comparing the CROST with PROST showed no specific association, nor any Spearman correlations (rs = -0.33-0.07). CONCLUSIONS: The AO Spine CROST showed moderate validity in a true clinical setting including patients from the daily clinical practice.


Assuntos
Traumatismos da Coluna Vertebral , Humanos , Reprodutibilidade dos Testes , Traumatismos da Coluna Vertebral/cirurgia , Coluna Vertebral , Inquéritos e Questionários , Medidas de Resultados Relatados pelo Paciente
2.
Emerg Radiol ; 31(1): 63-71, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38194212

RESUMO

PURPOSE: Assessing the diagnostic performance and supplementary value of whole-body computed tomography scout view (SV) images in the detection of thoracolumbar spine injuries in early resuscitation phase and identifying frequent image quality confounders. METHODS: In this retrospective database analysis at a tertiary emergency center, three blinded senior experts independently assessed SV to detect thoracolumbar spine injuries. The findings were categorized according to the AO Spine classification system. Confounders impacting SV image quality were identified. The suspected injury level and severity, along with the confidence level, were indicated. Diagnostic performance was estimated using the caret package in R programming language. RESULTS: We assessed images of 199 patients, encompassing 1592 vertebrae (T10-L5), and identified 56 spinal injuries (3.5%). Among the 199 cases, 39 (19.6%) exhibited at least one injury in the thoracolumbar spine, with 12 (6.0%) of them displaying multiple spinal injuries. The pooled sensitivity, specificity, and accuracy were 47%, 99%, and 97%, respectively. All experts correctly identified the most severe injury of AO type C. The most common image confounders were medical equipment (44.6%), hand position (37.6%), and bowel gas (37.5%). CONCLUSION: SV examination holds potential as a valuable supplementary tool for thoracolumbar spinal injury detection when CT reconstructions are not yet available. Our data show high specificity and accuracy but moderate sensitivity. While not sufficient for standalone screening, reviewing SV images expedites spinal screening in mass casualty incidents. Addressing modifiable factors like medical equipment or hand positioning can enhance SV image quality and assessment.


Assuntos
Traumatismo Múltiplo , Fraturas da Coluna Vertebral , Traumatismos da Coluna Vertebral , Humanos , Estudos Retrospectivos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/lesões , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/lesões , Tomografia Computadorizada por Raios X/métodos , Traumatismos da Coluna Vertebral/diagnóstico por imagem
3.
Eur Spine J ; 32(3): 934-949, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36715755

RESUMO

PURPOSE: The aim of this study was to assess safety and efficacy of vertebral body stenting (VBS) by analyzing (1) radiographic outcome, (2) clinical outcome, and (3) perioperative complications in patients with vertebral compression fractures treated with VBS at minimum 6-month follow-up. METHODS: In this retrospective cohort study, 78 patients (61 ± 14 [21-90] years; 67% female) who have received a vertebral body stent due to a traumatic, osteoporotic or metastatic thoracolumbar compression fracture at our hospital between 2012 and 2020 were included. Median follow-up was 0.9 years with a minimum follow-up of 6 months. Radiographic and clinical outcome was analyzed directly, 6 weeks, 12 weeks, 6 months postoperatively, and at last follow-up. RESULTS: Anterior vertebral body height of all patients improved significantly by mean 6.2 ± 4.8 mm directly postoperatively (p < 0.0001) and remained at 4.3 ± 5.1 mm at last follow-up compared to preoperatively (p < 0.0001). The fracture kyphosis angle of all patients improved significantly by mean 5.8 ± 6.9 degrees directly postoperatively (p < 0.0001) and remained at mean 4.9 ± 6.9 degrees at last follow-up compared to preoperatively (p < 0.0001). The segmental kyphosis angle of all patients improved significantly by mean 7.1 ± 7.6 degrees directly postoperatively (p < 0.0001) and remained at mean 2.8 ± 7.8 degrees at last follow-up compared to preoperatively (p = 0.03). Back pain was ameliorated from a preoperative median Numeric Rating Scale value of 6.5 to 3.0 directly postoperatively and further bettered to 1.0 six months postoperatively (p = 0.0001). Revision surgery was required in one patient after 0.4 years. CONCLUSION: Vertebral body stenting is a safe and effective treatment option for osteoporotic, traumatic and metastatic compression fractures.


Assuntos
Fraturas por Compressão , Cifose , Fraturas da Coluna Vertebral , Humanos , Feminino , Masculino , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/complicações , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Corpo Vertebral , Estudos Retrospectivos , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia , Vértebras Torácicas/lesões , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Vértebras Lombares/lesões , Cifose/cirurgia , Stents/efeitos adversos
4.
Eur Spine J ; 32(1): 46-54, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36449081

RESUMO

PURPOSE: To validate the AO Spine Subaxial Injury Classification System with participants of various experience levels, subspecialties, and geographic regions. METHODS: A live webinar was organized in 2020 for validation of the AO Spine Subaxial Injury Classification System. The validation consisted of 41 unique subaxial cervical spine injuries with associated computed tomography scans and key images. Intraobserver reproducibility and interobserver reliability of the AO Spine Subaxial Injury Classification System were calculated for injury morphology, injury subtype, and facet injury. The reliability and reproducibility of the classification system were categorized as slight (ƙ = 0-0.20), fair (ƙ = 0.21-0.40), moderate (ƙ = 0.41-0.60), substantial (ƙ = 0.61-0.80), or excellent (ƙ = > 0.80) as determined by the Landis and Koch classification. RESULTS: A total of 203 AO Spine members participated in the AO Spine Subaxial Injury Classification System validation. The percent of participants accurately classifying each injury was over 90% for fracture morphology and fracture subtype on both assessments. The interobserver reliability for fracture morphology was excellent (ƙ = 0.87), while fracture subtype (ƙ = 0.80) and facet injury were substantial (ƙ = 0.74). The intraobserver reproducibility for fracture morphology and subtype were excellent (ƙ = 0.85, 0.88, respectively), while reproducibility for facet injuries was substantial (ƙ = 0.76). CONCLUSION: The AO Spine Subaxial Injury Classification System demonstrated excellent interobserver reliability and intraobserver reproducibility for fracture morphology, substantial reliability and reproducibility for facet injuries, and excellent reproducibility with substantial reliability for injury subtype.


Assuntos
Fraturas Ósseas , Traumatismos da Coluna Vertebral , Humanos , Reprodutibilidade dos Testes , Traumatismos da Coluna Vertebral/diagnóstico por imagem , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/lesões , Tomografia Computadorizada por Raios X/métodos , Vértebras Lombares/lesões , Variações Dependentes do Observador
5.
Eur Spine J ; 32(6): 2120-2130, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37031293

RESUMO

PURPOSE: The AO Spine PROST (Patient Reported Outcome Spine Trauma) was developed for people with spine trauma and minor or no neurological impairment. The purpose is to investigate health professionals' perspective on the applicability of the AO Spine PROST for people with motor-complete traumatic or non-traumatic spinal cord injury (SCI), using a discussion meeting and international survey study. METHODS: A discussion meeting with SCI rehabilitation physicians in the Netherlands was performed, followed by a worldwide online survey among the AO Spine International community, involved in the care of people with SCI. Participants rated the comprehensibility, relevance, acceptability, feasibility and completeness of the AO Spine PROST on a 1-5 point scale (5 most positive). Comments could be provided per question. RESULTS: The discussion meeting was attended by 13 SCI rehabilitation physicians. The survey was completed by 196 participants. Comprehensibility (mean ± SD: 4.1 ± 0.8), acceptability (4.0 ± 0.8), relevance (3.9 ± 0.8), completeness (3.9 ± 0.8), and feasibility (4.1 ± 0.7) of the AO Spine PROST were rated positively for use in people with motor-complete traumatic or non-traumatic SCI. Only a few participants questioned the relevance of items on the lower extremities (e.g., walking) or missed items on pulmonary functioning and complications. Some recommendations were made for improvement in instructions, terminology and examples of the tool. CONCLUSION: Health professionals found the AO Spine PROST generally applicable for people with motor-complete traumatic or non-traumatic SCI. This study provides further evidence for the use of the AO Spine PROST in spine trauma care, rehabilitation and research, as well as suggestions for its further development.


Assuntos
Traumatismos da Medula Espinal , Traumatismos da Coluna Vertebral , Humanos , Transferência Intratubária do Zigoto , Coluna Vertebral , Traumatismos da Medula Espinal/cirurgia , Medidas de Resultados Relatados pelo Paciente
6.
Eur Spine J ; 31(10): 2812-2821, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35976438

RESUMO

PURPOSE: Implant leakage is the most common complication of vertebral augmentation. Alternative injectable materials must demonstrate intravascular safety comparable to or better than polymethyl methacrylate (PMMA). This study assessed the systemic effects of a triphasic calcium-based implant or PMMA injected directly into the femoral vein in a large animal model designed to mimic severe intravascular implant leakage. METHODS: Six skeletally mature female sheep were randomly assigned (n = 3) to either the PMMA or the triphasic implant (AGN1, composition: calcium sulfate, ß-tricalcium phosphate, brushite) treatment group. Femoral veins of each sheep were directly injected with 0.5 mL of implant material to mimic leakage volumes reported during PMMA vertebroplasty. To compare acute systemic effects of the materials, cardiovascular parameters, laboratory coagulation markers, and calcium and sulfate serum levels were monitored for 60 min after implant injection. Thrombotic and embolic events were evaluated by radiologic imaging, necropsy, and histopathology. RESULTS: Heart rate, systemic arterial blood pressure, arterial oxygenation, arterial carbon dioxide content, and coagulation markers remained within physiological range after either AGN1 or PMMA injection. No blood flow interruption in the larger pulmonary vessels was observed in either group. Lung histopathology revealed that the severity of thrombotic changes after AGN1 injection was minimal to slight, while changes after PMMA injection were minimal to massive. CONCLUSION: Acute systemic effects of intravascular AGN1 appeared to be comparable to or less than that of intravascular PMMA. Furthermore, in this preliminary study, the severity and incidence of pulmonary histological changes were lower for AGN1 compared to PMMA.


Assuntos
Embolia Pulmonar , Vertebroplastia , Animais , Cimentos Ósseos , Cálcio , Sulfato de Cálcio , Dióxido de Carbono , Feminino , Polimetil Metacrilato , Ovinos , Vertebroplastia/métodos
7.
Eur Spine J ; 30(9): 2570-2576, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33740146

RESUMO

PURPOSE: Factors influencing paraspinal muscle degeneration are still not well understood. Fatty infiltration is known to be one main feature of the degeneration cascade. The aim of this cross-sectional study was to illustrate the 3D cluster of paraspinal lumbar muscle degeneration on T2-weighted MRI images using our newly developed software application 'iSix'. METHODS: Mono- (Mm. rotatores), multi- (Mm. multifidus) and pluri-segmental (M. erector spinae) lumbar muscles groups were segmented on T2-weighted MR sequences using a novel computer-assisted technique for quantitative muscle/fat discrimination. The degree of fatty infiltration of the three predefined muscle groups was compared on a 3-dimensional basis, with regard to segment involvement and age. General linear models were utilized for statistical comparison. RESULTS: N = 120 segments (age: 52.7; range 16-87 years) could be included. The overall relative fatty infiltration of the mono-segmental muscles was higher (21.1 14.5%) compared to the multi-segmental (16.0 8.8% p = 0.049) and pluri-segmental muscles (8.5 8.0%; p = 0.03). Mono-segmental muscles on the levels L4/5 (22.9 ± 10.2 [CI 17.6-28.2] %) and L5/S1 (27.01 ± 15.1 [CI 21.4-32.7] %) showed a significant higher amount of fat compared to the levels L2/3 (8.2 ± 6.8 [CI 2.2-14.2] %; L4/5 vs. L2/3, p = 0.03; L5/S1 vs. L2/3, p = 0.02) and L3/4 (13.2 ± 5.4 [CI 8.6-17.7]%; L4/5 vs. L3/4, p = 0.02; L5/S1 vs. L3/4, p < 0.01). Multivariate linear regression analyses revealed age and Pfirrmann grade as independent factors for fatty muscle degeneration. CONCLUSIONS: 3D analysis of fatty infiltration is an innovative tool to study lumbar muscle degeneration. Mono-segmental muscles are more severely affected by degeneration compared to multi-/pluri-segmental muscles, especially at the L4/5 and L5/S1 level. Age and disc degeneration independently correlate with muscle degeneration.


Assuntos
Degeneração do Disco Intervertebral , Vértebras Lombares , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Região Lombossacral/diagnóstico por imagem , Pessoa de Meia-Idade , Músculos Paraespinais/diagnóstico por imagem , Adulto Jovem
8.
Eur Spine J ; 30(9): 2631-2644, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-32815075

RESUMO

PURPOSE: To validate the Dutch version of AOSpine PROST (Patient Reported Outcome Spine Trauma). METHODS: Patients were recruited from two level-1 trauma centers from the Netherlands. Next to the AOSpine PROST, patients also filled out SF-36 for concurrent validity. Descriptive statistics were used to analyze the characteristics. Content validity was assessed by evaluating the number of inapplicable or missing questions. Also floor and ceiling effects were analyzed. Internal consistency was assessed by calculating Cronbach's α and item-total correlation coefficients (itcc). Spearman correlation tests were performed within AOSpine PROST items and in correlation with SF-36. Test-retest reliability was analyzed using Intraclass Correlation Coefficients (ICC). Responsiveness was assessed by calculating effect sizes (ES) and standardized response mean (SRM). Factor analysis was performed to explore any dimensions within AOSpine PROST. RESULTS: Out of 179 enrolled patients, 163 (91.1%) were included. Good results were obtained for content validity. No floor or ceiling effects were seen. Internal consistency was excellent (Cronbach's α = 0.96, itcc 0.50-0.86), with also good Spearman correlations (0.25-0.79). Compared to SF-36, the strongest correlation was seen for physical functioning (0.79; p < .001). Also test-retest reliability was excellent (ICC = 0.92). Concerning responsiveness analysis, very good results were seen with ES = 1.81 and SRM = 2.03 (p < 0.001). Factor analysis revealed two possible dimensions (Eigenvalues > 1), explaining 65.4% of variance. CONCLUSIONS: Very satisfactory results were obtained for reliability, validity and responsiveness of the Dutch version of AOSpine PROST. Treating surgeons are encouraged to use this novel and validated tool in clinical setting and research to contribute to evidence-based and patient-centered care.


Assuntos
Traumatismos da Coluna Vertebral , Transferência Intratubária do Zigoto , Humanos , Países Baixos , Medidas de Resultados Relatados pelo Paciente , Reprodutibilidade dos Testes
9.
Eur Spine J ; 30(6): 1635-1650, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33797624

RESUMO

PURPOSE: To determine the variation in the global treatment practices for subaxial unilateral cervical spine facet fractures based on surgeon experience, practice setting, and surgical subspecialty. METHODS: A survey was sent to 272 members of the AO Spine Subaxial Injury Classification System Validation Group worldwide. Questions surveyed surgeon preferences with regard to diagnostic work-up and treatment of fracture types F1-F3, according to the AO Spine Subaxial Cervical Spine Injury Classification System, with various associated neurologic injuries. RESULTS: A total of 161 responses were received. Academic surgeons use the facet portion of the AO Spine classification system less frequently (61.6%) compared to hospital-employed and private practice surgeons (81.1% and 81.8%, respectively) (p = 0.029). The overall consensus was in favor of operative treatment for any facet fracture with radicular symptoms (N2) and for any fractures categorized as F2N2 and above. For F3N0 fractures, significantly less surgeons from Africa/Asia/Middle East (49%) and Europe (59.2%) chose operative treatment than from North/Latin/South America (74.1%) (p = 0.025). For F3N1 fractures, significantly less surgeons from Africa/Asia/Middle East (52%) and Europe (63.3%) recommended operative treatment than from North/Latin/South America (84.5%) (p = 0.001). More than 95% of surgeons included CT in their work-up of facet fractures, regardless of the type. No statistically significant differences were seen in the need for MRI to decide treatment. CONCLUSION: Considerable agreement exists between surgeon preferences with regard to unilateral facet fracture management with few exceptions. F2N2 fracture subtypes and subtypes with radiculopathy (N2) appear to be the threshold for operative treatment.


Assuntos
Fraturas da Coluna Vertebral , Fusão Vertebral , Cirurgiões , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/lesões , Vértebras Cervicais/cirurgia , Humanos , Imageamento por Ressonância Magnética , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia
10.
Eur Spine J ; 30(2): 517-523, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32700126

RESUMO

PURPOSE: The management of cervical facet dislocation injuries remains controversial. The main purpose of this investigation was to identify whether a surgeon's geographic location or years in practice influences their preferred management of traumatic cervical facet dislocation injuries. METHODS: A survey was sent to 272 AO Spine members across all geographic regions and with a variety of practice experience. The survey included clinical case scenarios of cervical facet dislocation injuries and asked responders to select preferences among various diagnostic and management options. RESULTS: A total of 189 complete responses were received. Over 50% of responding surgeons in each region elected to initiate management of cervical facet dislocation injuries with an MRI, with 6 case exceptions. Overall, there was considerable agreement between American and European responders regarding management of these injuries, with only 3 cases exhibiting a significant difference. Additionally, results also exhibited considerable management agreement between those with ≤ 10 and > 10 years of practice experience, with only 2 case exceptions noted. CONCLUSION: More than half of responders, regardless of geographical location or practice experience, identified MRI as a screening imaging modality when managing cervical facet dislocation injuries, regardless of the status of the spinal cord and prior to any additional intervention. Additionally, a majority of surgeons would elect an anterior approach for the surgical management of these injuries. The study found overall agreement in management preferences of cervical facet dislocation injuries around the globe.


Assuntos
Luxações Articulares , Fusão Vertebral , Traumatismos da Coluna Vertebral , Cirurgiões , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/lesões , Vértebras Cervicais/cirurgia , Humanos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Traumatismos da Coluna Vertebral/diagnóstico por imagem , Traumatismos da Coluna Vertebral/cirurgia
11.
BMC Musculoskelet Disord ; 22(1): 579, 2021 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-34167510

RESUMO

BACKGROUND: The economic burden of vertebral compression fractures (VCF) caused by osteoporosis was estimated at 37 billion euros in the European Union in 2010. In addition, the incidence is expected to increase by 25% in 2025. The recommendations for the therapy of VCFs (conservative treatment versus cement augmentation procedures) are controversial, what could be partly explained by the lack of standardized outcomes for measuring the success of both treatments. Consensus on outcome parameters may improve the relevance of a study and for further comparisons in meta-analyses. The aim of this study was to analyze outcome measures from frequently cited randomized controlled trials (RCTs) about VCF treatments in order to provide guidance for future studies. MATERIAL AND METHODS: We carried out a systematic search of all implemented databases from 1973 to 2019 using the Web of Science database. The terms "spine" and "random" were used for the search. We included: Level I RCTs, conservative treatment or cement augmentation of osteoporotic vertebral fractures, cited ≥50 times. The outcome parameters of each study were extracted and sorted according to the frequency of use. RESULTS: Nine studies met the inclusion criteria. In total, 23 different outcome parameters were used in the nine analyzed studies. Overall, the five most frequently used outcome parameters (≥ 4 times used) were the visual analogue scale (VAS) for pain (n = 9), European Quality of Life-5 Dimensions (EQ-5D; n = 4) and Roland-Morris Disability Questionnaire (RMDQ, n = 4). CONCLUSION: With our study, we demonstrated that a large inconsistency exists between outcome measures in highly cited Level I studies of VCF treatment. Pain (VAS), followed by HrQoL (EQ-5D) and disability and function (RMDQ), opioid use, and radiological outcome (kyphotic angle, VBH, and new VCFs) were the most commonly used outcome parameters.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Fraturas por Compressão/epidemiologia , Fraturas por Compressão/cirurgia , Humanos , Fraturas por Osteoporose/epidemiologia , Fraturas por Osteoporose/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Fraturas da Coluna Vertebral/epidemiologia , Fraturas da Coluna Vertebral/cirurgia , Resultado do Tratamento , Vertebroplastia/efeitos adversos
12.
BMC Emerg Med ; 21(1): 27, 2021 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-33663394

RESUMO

BACKGROUND: Spinal injuries are present in 16-31% of polytraumatized patients. Rapid identification of spinal injuries requiring immobilization or operative treatment is essential. The Lodox-Statscan (LS) has evolved into a promising time-saving diagnostic tool to diagnose life-threatening injuries with an anterior-posterior (AP)-full-body digital X-ray. METHODS: We aimed to analyze the diagnostic accuracy and the interrater reliability of AP-LS to detect spinal injuries in polytraumatized patients. Therefore, within 3 years, AP-LS of polytraumatized patients (ISS ≥ 16) were retrospectively analyzed by three independent observers. The sensitivity and specificity of correct diagnosis with AP-LS compared to CT scan were calculated. The diagnostic accuracy was evaluated by using the area under the ROC (receiver operating characteristic curve) for sensitivity and specificity. Interrater reliability between the three observers was calculated using Fleiss' Kappa. The sensitivity of AP-LS was further analyzed by the severity of spinal injuries. RESULTS: The study group included 320 patients (48.5 years ±19.5, 89 women). On CT scan, 207 patients presented with a spinal injury (65%, total of 332 injuries). AP-LS had a low sensitivity of 9% (31 of 332, range 0-24%) and high specificity of 99% (range 98-100%). The sensitivity was highest for thoracic spinal injuries (14%). The interrater reliability was slight (κ = 0.02; 95% CI: 0.00, 0.03). Potentially unstable spinal injuries were more likely to be detected than stable injuries (sensitivity 18 and 6%, respectively). CONCLUSION: This study demonstrated high specificity with low sensitivity of AP-LS in detecting spinal injuries compared to CT scan. In polytraumatized patients, AP-LS, implemented in the Advanced Trauma Life Support-algorithm, is a helpful tool to diagnose life-threatening injuries. However, if spinal injuries are suspected, performing a full-body CT scan is necessary for correct diagnosis.


Assuntos
Traumatismos da Coluna Vertebral , Ferimentos e Lesões/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Traumatismos da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Raios X
13.
Eur Spine J ; 29(10): 2550-2559, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32632640

RESUMO

PURPOSE: To report on the development of AOSpine CROST (Clinician Reported Outcome Spine Trauma) and results of an initial reliability study. METHODS: The AOSpine CROST was developed using an iterative approach of multiple cycles of development, review, and revision including an expert clinician panel. Subsequently, a reliability study was performed among an expert panel who were provided with 20 spine trauma cases, administered twice with 4-week interval. The results of the developmental process were analyzed using descriptive statistics, the reliability per parameter using Kappa statistics, inter-rater rater agreement using intraclass correlation coefficient (ICC), and internal consistency using Cronbach's α. RESULTS: The AOSpine CROST was developed and consisted of 10 parameters, 2 of which are only applicable for surgically treated patents ('Wound healing' and 'Implants'). A dichotomous scoring system ('yes' or 'no' response) was incorporated to express expected problems for the short term and long term. In the reliability study, 16 (84.2%) participated in the first round and 14 (73.7%) in the second. Intra-rater reliability was fair to good for both time points (κ = 0.40-0.80 and κ = 0.31-0.67). Results of inter-rater reliability were lower (κ = 0.18-0.60 and κ = 0.16-0.46). Inter-rater agreement for total scores showed moderate results (ICC = 0.52-0.60), and the internal consistency was acceptable (α = 0.76-0.82). CONCLUSIONS: The AOSpine CROST, an outcome tool for the surgeons, was developed using an iterative process. An initial reliability analysis showed fair to moderate results and acceptable internal consistency. Further clinical validation studies will be performed to further validate the tool.


Assuntos
Traumatismos da Coluna Vertebral , Cirurgiões , Humanos , Variações Dependentes do Observador , Medidas de Resultados Relatados pelo Paciente , Reprodutibilidade dos Testes
14.
Arch Orthop Trauma Surg ; 140(3): 343-351, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31520112

RESUMO

PURPOSE: To describe a new surgical technique for neurolysis and decompression of L4 and L5 nerve root entrapment after vertical sacral fractures via the pararectus approach for acetabular fractures, and to present four case examples. PATIENTS AND METHODS: We retrospectively evaluated four patients suffering radiculopathy from entrapment of the L4 or L5 nerve root in vertical sacral fractures between January and December 2016. The mean follow-up period after surgery was 18 (range 7-27) months. All patients underwent direct decompression and neurolysis of the L4 and L5 nerve roots via the single-incision, intrapelvic, extraperitoneal pararectus approach. RESULTS: In all patients, the L4 and L5 nerve root was successfully visualized and decompressed, proving feasibility of the pararectus approach for this indication. No patient presented with a neural tear. Complete neurologic recovery was present in one patient at last follow-up; two patients had incomplete recovery of their radiculopathy; and one patient had no improvement after nerve root decompression. CONCLUSIONS: The pararectus approach allows for sufficient visualisation and direct decompression and neurolysis of the L4 and L5 nerve root entrapped in vertical sacral fractures. Although neurologic recovery was not achieved in all patients in this small case series, the approach may be a suitable alternative to posterior approaches and other anterior approaches such as the lateral window of the ilioinguinal approach.


Assuntos
Descompressão Cirúrgica/métodos , Vértebras Lombares , Sacro , Fraturas da Coluna Vertebral/cirurgia , Raízes Nervosas Espinhais/cirurgia , Humanos , Vértebras Lombares/inervação , Vértebras Lombares/cirurgia , Síndromes de Compressão Nervosa/cirurgia , Estudos Retrospectivos , Sacro/lesões , Sacro/cirurgia
15.
Int J Mol Sci ; 20(20)2019 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-31614494

RESUMO

We investigated the effects of a fibrin-hyaluronic acid hydrogel (FBG-HA) and fibroblast growth factor 18 (FGF-18) for nucleus pulposus (NP) regeneration. Healthy bovine (n = 4) and human degenerated NP cells (n = 4) were cultured for 14 days in FBG-HA hydrogel with FGF-18 (∆51-mutant or wild-type) in the culture medium. Gene expression, DNA content, and glycosaminoglycan (GAG) synthesis were evaluated on day 7 and 14. Additionally, histology was performed. Human NP cells cultured in FBG-HA hydrogel showed an increase in collagen type II (COL2) and carbonic anhydrase XII (CA12) gene expression after 14 or 7 days of culture, respectively. GAG release into the conditioned medium increased over 14 days. Healthy bovine NP cells showed increased gene expression of ACAN from day 7 to day 14. Wild type FGF-18 up-regulated CA12 gene expression of human NP cells. Histology revealed an increase of proteoglycan deposition upon FGF-18 stimulation in bovine but not in human NP cells. The FBG-HA hydrogel had a positive modulatory effect on human degenerated NP cells. Under the tested conditions, no significant effect of FGF-18 was observed on cell proliferation or GAG synthesis in human NP cells.


Assuntos
Técnicas de Cultura de Células/métodos , Fatores de Crescimento de Fibroblastos/farmacologia , Ácido Hialurônico/química , Núcleo Pulposo/citologia , Animais , Biomimética , Anidrases Carbônicas/genética , Bovinos , Células Cultivadas , Colágeno Tipo II/metabolismo , Fatores de Crescimento de Fibroblastos/química , Glicosaminoglicanos/metabolismo , Humanos , Ácido Hialurônico/farmacologia , Hidrogéis/química , Núcleo Pulposo/efeitos dos fármacos , Núcleo Pulposo/metabolismo , Fenótipo , Regeneração
16.
Eur Spine J ; 27(8): 1785-1797, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29789921

RESUMO

PURPOSE: Comparison of two annulus fibrosus injury models that mimic intervertebral disc (IVD) herniation, enabling the study of IVD behaviour under three loading regimes in a bovine organ culture model. METHODS: An injury was induced by custom-designed cross-incision tool or a 2-mm biopsy punch in IVDs. Discs were cultured for 14 days under (1) complex (compression and torsion), (2) static, and (3) no load. Disc height, mitochondrial activity, DNA and glycosaminoglycan (GAG) contents, and disc stiffness under complex load were determined. Further, gene expression and histology analysis were performed. RESULTS: While both injury models did not change the compressional stiffness of IVDs, cross-incision decreased disc height under complex load. Moreover, under complex load, the biopsy punch injury induced down-regulation of several anabolic, catabol ic, and inflammatory genes, whereas cross-incision did not significantly differ from control discs. However, DNA and GAG contents were in the range of the healthy control discs for both injury models but did show lower contents under no load and static load. Injury side and contralateral side of the IVD showed a similar behaviour on the biochemical assays tested. CONCLUSION: Compressional stiffness, GAG and DNA contents, did not differ between injury models under complex load. This behaviour was partially attributed to the positive influence of complex loading on matrix regeneration and cell viability. However, disc height was reduced for the cross-incision. Relative gene expression changes of the inflammatory and anabolic genes for the biopsy punch approach might indicate that induced damage was too intense to trigger any inflammatory or repair response. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Deslocamento do Disco Intervertebral/patologia , Disco Intervertebral/patologia , Técnicas de Cultura de Órgãos/métodos , Animais , Bovinos , Sobrevivência Celular/fisiologia , Citocinas/metabolismo , DNA/metabolismo , Modelos Animais de Doenças , Expressão Gênica/fisiologia , Glicosaminoglicanos/metabolismo , Disco Intervertebral/metabolismo , Deslocamento do Disco Intervertebral/metabolismo , Suporte de Carga/fisiologia
17.
Int J Mol Sci ; 19(4)2018 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-29652862

RESUMO

Spinal fusion is a common surgical procedure to address a range of spinal pathologies, like damaged or degenerated discs. After the removal of the intervertebral disc (IVD), a structural spacer is positioned followed by internal fixation, and fusion of the degenerated segment by natural bone growth. Due to their osteoinductive properties, bone morphogenetic proteins (BMP) are applied to promote spinal fusion. Although spinal fusion is successful in most patients, the rates of non-unions after lumbar spine fusion range from 5% to 35%. Clinical observations and recent studies indicate, that the incomplete removal of disc tissue might lead to failure of spinal fusion. Yet, it is still unknown if a secretion of BMP antagonists in intervertebral disc (IVD) cells could be the reason of inhibition in bone formation. In this study, we co-cultured human primary osteoblasts (OB) and IVD cells i.e., nucleus pulposus (NPC), annulus fibrosus (AFC) and cartilaginous endplate cells (CEPC), to test the possible inhibitory effect from IVD cells on OB. Although we could see a trend in lower matrix mineralization in OB co-cultured with IVD cells, results of alkaline phosphatase (ALP) activity and gene expression of major bone genes were inconclusive. However, in NPC, AFC and CEPC beads, an up-regulation of several BMP antagonist genes could be detected. Despite being able to show several indicators for an inhibition of osteoinductive effects due to IVD cells, the reasons for pseudarthrosis after spinal fusion remain unclear.


Assuntos
Fosfatase Alcalina/metabolismo , Técnicas de Cocultura/métodos , Disco Intervertebral/citologia , Osteoblastos/citologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anel Fibroso/citologia , Calcificação Fisiológica , Células Cultivadas , Feminino , Expressão Gênica , Humanos , Masculino , Metaloproteinases da Matriz Secretadas/metabolismo , Núcleo Pulposo/citologia , Osteoblastos/metabolismo
18.
Eur Spine J ; 25(11): 3450-3455, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-25841359

RESUMO

PURPOSE: Leakage is the most common complication of percutaneous cement augmentation of the spine. The viscosity of the polymethylmethacrylate (PMMA) cement is strongly correlated with the likelihood of cement leakage. We hypothesized that cement leakage can be reduced by sequential cement injection in a vertebroplasty model. METHODS: A standardized vertebral body substitute model, consisting of aluminum oxide foams coated by acrylic cement with a preformed leakage path, simulating a ventral vein, was developed. Three injection techniques of 6 ml PMMA were assessed: injection in one single step (all-in-one), injection of 1 ml at the first and 5 ml at the second step with 1 min latency in-between (two-step), and sequential injection of 0.5 ml with 1-min latency between the sequences (sequential). Standard PMMA vertebroplasty cement was used; each injection type was tested on ten vertebral body substitute models with two possible leakage paths per model. Leakage was assessed by radiographs using a zonal graduation: intraspongious = no leakage and extracortical = leakage. RESULTS: The leakage rate was significantly lower in the "sequential" technique (2/20 leakages) followed by "two-step" (15/20) and "all-in-one" (20/20) techniques (p < 0.001). The RR for a cement leakage was 10.0 times higher in the "all-in-one" compared to the "sequential" group (95 % confidence intervals 2.7-37.2; p < 0.001). CONCLUSIONS: The sequential cement injection is a simple approach to minimize the risk for leakage. Taking advantage of the temperature gradient between body and room temperature, it is possible to increase the cement viscosity inside the vertebra while keeping it low in the syringe. Using sequential injection of small cement volumes, further leakage paths are blocked before further injection of the low-viscosity cement.


Assuntos
Cimentos Ósseos/efeitos adversos , Modelos Biológicos , Polimetil Metacrilato/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Fraturas da Coluna Vertebral/cirurgia , Vertebroplastia , Humanos , Vertebroplastia/efeitos adversos , Vertebroplastia/métodos
19.
J Clin Densitom ; 18(1): 109-16, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25087043

RESUMO

Reduced bone stock can result in fractures that mostly occur in the spine, distal radius, and proximal femur. In case of operative treatment, osteoporosis is associated with an increased failure rate. To estimate implant anchorage, mechanical methods seem to be promising to measure bone strength intraoperatively. It has been shown that the mechanical peak torque correlates with the local bone mineral density and screw failure load in hip, hindfoot, humerus, and spine in vitro. One device to measure mechanical peak torque is the DensiProbe (AO Research Institute, Davos, Switzerland). The device has shown its effectiveness in mechanical peak torque measurement in mechanical testing setups for the use in hip, hindfoot, and spine. In all studies, the correlation of mechanical torque measurement and local bone mineral density and screw failure load could be shown. It allows the surgeon to judge local bone strength intraoperatively directly at the region of interest and gives valuable information if additional augmentation is needed. We summarize methods of this new technique, its advantages and limitations, and give an overview of actual and possible future applications.


Assuntos
Densidade Óssea , Densitometria , Fraturas Ósseas/cirurgia , Cuidados Intraoperatórios , Complicações Intraoperatórias/prevenção & controle , Osteoporose/diagnóstico , Complicações Pós-Operatórias/prevenção & controle , Pesquisa Comparativa da Efetividade , Densitometria/instrumentação , Densitometria/métodos , Equipamentos para Diagnóstico , Desenho de Equipamento , Fixação de Fratura/métodos , Fraturas Ósseas/complicações , Humanos , Cuidados Intraoperatórios/instrumentação , Cuidados Intraoperatórios/métodos , Teste de Materiais , Osteoporose/complicações
20.
Eur Spine J ; 23(3): 689-94, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24170238

RESUMO

PURPOSE: Currently, the diagnosis of pedicle screw (PS) loosening is based on a subjectively assessed halo sign, that is, a radiolucent line around the implant wider than 1 mm in plain radiographs. We aimed at development and validation of a quantitative method to diagnose PS loosening on radiographs. METHODS: Between 11/2004 and 1/2010 36 consecutive patients treated with thoraco-lumbar spine fusion with PS instrumentation without PS loosening were compared with 37 other patients who developed a clinically manifesting PS loosening. Three different angles were measured and compared regarding their capability to discriminate the loosened PS over the postoperative course. The inter-observer invariance was tested and a receiver operating characteristics curve analysis was performed. RESULTS: The angle measured between the PS axis and the cranial endplate was significantly different between the early and all later postoperative images. The Spearman correlation coefficient for the measurements of two observers at each postoperative time point ranged between 0.89 at 2 weeks to 0.94 at 2 months and 1 year postoperative. The angle change of 1.9° between immediate postoperative and 6-month postoperative was 75% sensitive and 89% specific for the identification of loosened screws (AUC = 0.82). DISCUSSION: The angle between the PS axis and the cranial endplate showed good ability to change in PS loosening. A change of this angle of at least 2° had a relatively high sensitivity and specificity to diagnose screw loosening.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Procedimentos Neurocirúrgicos/métodos , Fusão Vertebral/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Radiografia , Estudos Retrospectivos , Sensibilidade e Especificidade , Vértebras Torácicas/cirurgia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA