Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 59(3)2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36984470

RESUMO

Background and Objectives: This study aims to evaluate artificial intelligence-calculated hepatorenal index (AI-HRI) as a diagnostic method for hepatic steatosis. Materials and Methods: We prospectively enrolled 102 patients with clinically suspected non-alcoholic fatty liver disease (NAFLD). All patients had a quantitative ultrasound (QUS), including AI-HRI, ultrasound attenuation coefficient (AC,) and ultrasound backscatter-distribution coefficient (SC) measurements. The ultrasonographic fatty liver indicator (US-FLI) score was also calculated. The magnetic resonance imaging fat fraction (MRI-PDFF) was the reference to classify patients into four grades of steatosis: none < 5%, mild 5-10%, moderate 10-20%, and severe ≥ 20%. We compared AI-HRI between steatosis grades and calculated Spearman's correlation (rs) between the methods. We determined the agreement between AI-HRI by two examiners using the intraclass correlation coefficient (ICC) of 68 cases. We performed a receiver operating characteristics (ROC) analysis to estimate the area under the curve (AUC) for AI-HRI. Results: The mean AI-HRI was 2.27 (standard deviation, ±0.96) in the patient cohort. The AI-HRI was significantly different between groups without (1.480 ± 0.607, p < 0.003) and with mild steatosis (2.155 ± 0.776), as well as between mild and moderate steatosis (2.777 ± 0.923, p < 0.018). AI-HRI showed moderate correlation with AC (rs = 0.597), SC (rs = 0.473), US-FLI (rs = 0.5), and MRI-PDFF (rs = 0.528). The agreement in AI-HRI was good between the two examiners (ICC = 0.635, 95% confidence interval (CI) = 0.411-0.774, p < 0.001). The AI-HRI could detect mild steatosis (AUC = 0.758, 95% CI = 0.621-0.894) with fair and moderate/severe steatosis (AUC = 0.803, 95% CI = 0.721-0.885) with good accuracy. However, the performance of AI-HRI was not significantly different (p < 0.578) between the two diagnostic tasks. Conclusions: AI-HRI is an easy-to-use, reproducible, and accurate QUS method for diagnosing mild and moderate hepatic steatosis.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Inteligência Artificial , Fígado/patologia , Ultrassonografia/métodos , Curva ROC , Imageamento por Ressonância Magnética/métodos
2.
J Vasc Surg ; 73(2): 510-515.e2, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32447038

RESUMO

OBJECTIVE: The purpose of this study was to report our results of patients' characteristics, procedural complications, and long-term patency in treatment of isolated infrarenal aortic stenosis (IIAS). METHODS: Forty symptomatic patients (28 female, 12 male; median age, 60 years [54.8-68 years]) with IIAS who underwent endovascular intervention between 2001 and 2017 were retrospectively analyzed. Patient, lesion, procedure, and balloon/stent characteristics were assessed. Follow-up included clinical status evaluation and color Doppler ultrasound examination. RESULTS: The cause of IIAS was atherosclerosis in all patients. Twenty percent of the patients were younger than 50 years; 85% had hypertension, 80% were smokers, 38% had hyperlipidemia, 23% had diabetes mellitus, 15% were obese (body mass index ≥30 kg/m2), and 8% had chronic kidney disease. The median stenosis grade was 80% (70%-80%), and the median lesion length was 19.9 mm (13-29.4 mm). Severe calcification was present in 8% of the patients. Percutaneous transluminal angioplasty was performed in four cases (10%), whereas stenting was performed in 36 (90%). One complication, an aortic rupture requiring surgical repair, occurred. The median follow-up was 61 months (17-101 months). The primary patency rate was 100% at 6 months, 97% at 12 and 24 months, and 88% at 60 and 96 months. Restenosis developed in three patients (8%); reintervention was carried out in two cases (5%). CONCLUSIONS: Endovascular therapy for IIAS provides a safe and effective long-term treatment strategy.


Assuntos
Angioplastia com Balão , Doenças da Aorta/terapia , Aterosclerose/terapia , Idoso , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Aterosclerose/diagnóstico por imagem , Aterosclerose/fisiopatologia , Constrição Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Retratamento , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
3.
BMC Med Imaging ; 20(1): 108, 2020 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-32957949

RESUMO

BACKGROUND: CT texture analysis (CTTA) has been successfully used to assess tissue heterogeneity in multiple diseases. The purpose of this work is to demonstrate the value of three-dimensional CTTA in the evaluation of diffuse liver disease. We aimed to develop CTTA based prediction models, which can be used for staging of fibrosis in different anatomic liver segments irrespective of variations in scanning parameters. METHODS: We retrospectively collected CT scans of thirty-two chronic hepatitis patients with liver fibrosis. The CT examinations were performed on either a 16- or a 64-slice scanner. Altogether 354 anatomic liver segments were manually highlighted on portal venous phase images, and 1117 three-dimensional texture parameters were calculated from each segment. The segments were divided between groups of low-grade and high-grade fibrosis using shear-wave elastography. The highly-correlated features (Pearson r > 0.95) were filtered out, and the remaining 453 features were normalized and used in a classification with k-means and hierarchical cluster analysis. The segments were split between the train and test sets in equal proportion (analysis I) or based on the scanner type (analysis II) into 64-slice train 16-slice validation cohorts for machine learning classification, and a subset of highly prognostic features was selected with recursive feature elimination. RESULTS: A classification with k-means and hierarchical cluster analysis divided segments into four main clusters. The average CT density was significantly higher in cluster-4 (110 HU ± SD = 10.1HU) compared to the other clusters (c1: 96.1 HU ± SD = 11.3HU; p < 0.0001; c2: 90.8 HU ± SD = 16.8HU; p < 0.0001; c3: 93.1 HU ± SD = 17.5HU; p < 0.0001); but there was no difference in liver stiffness or scanner type among the clusters. The optimized random forest classifier was able to distinguish between low-grade and high-grade fibrosis with excellent cross-validated accuracy in both the first and second analysis (AUC = 0.90, CI = 0.85-0.95 vs. AUC = 0.88, CI = 0.84-0.91). The final support vector machine model achieved an excellent prediction rate in the second analysis (AUC = 0.91, CI = 0.88-0.94) and an acceptable prediction rate in the first analysis (AUC = 0.76, CI = 0.67-0.84). CONCLUSIONS: In conclusion, CTTA-based models can be successfully applied to differentiate high-grade from low-grade fibrosis irrespective of the imaging platform. Thus, CTTA may be useful in the non-invasive prognostication of patients with chronic liver disease.


Assuntos
Imageamento Tridimensional/métodos , Cirrose Hepática/diagnóstico por imagem , Fígado/patologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Diagnóstico Diferencial , Técnicas de Imagem por Elasticidade , Estudos de Viabilidade , Feminino , Humanos , Fígado/diagnóstico por imagem , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Máquina de Vetores de Suporte , Aprendizado de Máquina não Supervisionado , Adulto Jovem
4.
J Clin Ultrasound ; 48(2): 67-74, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31463955

RESUMO

PURPOSE: Our study aimed to evaluate the technical success rate, interobserver reproducibility, and accuracy of shearwave elastography (SWE) in the staging of hepatitis C virus (HCV)-associated liver fibrosis. METHODS: A total of 10 healthy controls and 49 patients with chronic liver disease were enrolled prospectively. Two examiners performed point shearwave elastography (pSWE) and two-dimensional shearwave elastography (2D-SWE) measurements with an RS85A ultrasound scanner using the S-Shearwave application (Samsung Medison, Hongcheon, Korea). The performance of S-Shearwave in the staging (METAVIR F0-F4) of liver fibrosis was compared with prior transient elastography (TE) with receiver operating characteristic (ROC) curve analysis. RESULTS: The interobserver reproducibility was excellent with pSWE (ICC = 0.92, 95% CI: 0.86-0.95, P < .001). A very good agreement was found between pSWE and TE measurements (ICC =0.85, 95% CI: 0.78-0.89, P < .001). The ROC analysis determined the optimal cut-off values of pSWE for the staging of chronic hepatitis C-associated fibrosis (F2, 1.46 m/s; F3, 1.63 m/s; F4, 1.95 m/s). Both observers achieved excellent diagnostic accuracy (AUROC: 94% vs 97%) in the detection of significant (≥F2) liver fibrosis. CONCLUSION: The interobserver agreement is excellent with S-Shearwave pSWE, and observers can diagnose significant liver fibrosis with a comparable accuracy to TE.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite C Crônica/complicações , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/etiologia , Adulto , Idoso , Técnicas de Imagem por Elasticidade/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
5.
Chin J Physiol ; 59(1): 33-8, 2016 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-26875560

RESUMO

Doppler interrogation studies of the liver blood flow indicate altered hepatic vein waveforms in association with impaired hepatocellular function. However, little is known about the mechanisms responsible for variations of these parameters in the absence of disease. We aimed to investigate the contribution of heritable and environmental factors to the physiological variability of hepatic vein flow in a twin cohort. Two hundred twenty-eight healthy adult Hungarian twins (69 monozygotic, 45 same-sex dizygotic pairs) underwent Doppler sonography of the hepatic vein. Age- and sex-adjusted heritability of the highest velocity (amplitude of S wave) of hepatic vein flow was negligible. Shared environment contributed to 33% (95% CI, 16%-51%), and unshared environment was responsible for the largest portion (67%; 95% CI, 49%-84%) of the variance. Duration of sports activities was significantly (P < 0.05) related to the magnitude of hepatic vein flow, while other risk factors and lifestyle characteristics had no significant influence. The data suggest that genetic factors have little impact on the parameters of hepatic venous blood flow. The variability observed in healthy twins by the Doppler interrogation can be explained by the effect of unshared environmental components primarily related to regular physical activity. These findings underscore the importance of unique environments in physiological variations of hepatic venous blood flow.


Assuntos
Veias Hepáticas/fisiologia , Adulto , Meio Ambiente , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Gêmeos Dizigóticos , Gêmeos Monozigóticos
6.
Croat Med J ; 56(2): 152-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25891875

RESUMO

AIM: To determine the reasons for large standard deviation of bronchodilator response (BDR) and establish whether there is a potential heritable component in healthy subjects. METHODS: 67 monozygotic and 42 dizygotic adult twin pairs were assessed for bronchodilator response (% change in FEV1 after inhaling 400 µg salbutamol). Univariate quantitative genetic modeling was performed. RESULTS: Multiple regression modeling showed a significant association between BDR and sex and baseline FEV1 (P<0.05), while no association was found with smoking habits, body mass index, or age. Within pair correlation in monozygotic twins was modest (0.332), but higher than in dizygotic twins (0.258). Age-, sex-, and baseline FEV1-adjusted genetic effect accounted for 14.9% (95% confidence interval, CI 0%-53.1%) of the variance of BDR, shared environmental effect for 18.4% (95% CI 0%-46.8%), and unshared environmental effect for 66.8% (95% CI 46.8%-88.7%). CONCLUSION: Our twin study showed that individual differences in BDR can be mostly explained by unshared environmental effects. In addition, it is the first study to show low, insignificant hereditary influences, independently from sex, age, and baseline FEV1.


Assuntos
Albuterol/administração & dosagem , Broncodilatadores/administração & dosagem , Volume Expiratório Forçado/genética , Interação Gene-Ambiente , Gêmeos Dizigóticos/genética , Gêmeos Monozigóticos/genética , Adulto , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Radiol Oncol ; 49(1): 10-6, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25810696

RESUMO

BACKGROUND: Whole-body magnetic resonance imaging (WB-MRI) and angiography (WB-MRA) has become increasingly popular in population-based research. We evaluated retrospectively the frequency of potentially relevant incidental findings throughout the body. MATERIALS AND METHODS: 22 highly health-conscious managers (18 men, mean age 47±9 years) underwent WB-MRI and WB-MRA between March 2012 and September 2013 on a Discovery MR750w wide bore 3 Tesla device (GE Healthcare) using T1 weighted, short tau inversion recovery (STIR) and diffusion weighted imaging (DWI) acquisitions according to a standardized protocol. RESULTS: A suspicious (pararectal) malignancy was detected in one patient which was confirmed by an endorectal sonography. Incidental findings were described in 20 subjects, including hydrocele (11 patients), benign bony lesion (7 patients) and non-specific lymph nodes (5 patients). Further investigations were recommended in 68% (ultrasound: 36%, computed tomography: 28%, mammography: 9%, additional MRI: 9%). WB-MRA were negative in 16 subjects. Vascular normal variations were reported in 23%, and a 40% left proximal common carotid artery stenosis were described in one subject. CONCLUSIONS: WB-MRI and MRA lead to the detection of clinically relevant diseases and unexpected findings in a cohort of healthy adults that require further imaging or surveillance in 68%. WB-MR imaging may play a paramount role in health screening, especially in the future generation of (epi)genetic based screening of malignant and atherosclerotic disorders. Our study is the first which involved a highly selected patient group using a high field 3-T wide bore magnet system with T1, STIR, MRA and whole-body DWI acquisitions as well.

8.
J Vasc Surg ; 59(5): 1418-21, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23768791

RESUMO

Absent common carotid artery with independent origin of internal and external carotid arteries from the subclavian artery is a rare but recognized phenomenon. We describe one such case with an associated symptomatic proximal high-grade stenosis of the right internal carotid artery. The abnormal carotid anatomy was not initially well appreciated, resulting in a failed surgical exploration and subsequent successful endovascular carotid stenting. To our knowledge, this is the first reported case of carotid stent in a right internal carotid artery originating from the subclavian artery.


Assuntos
Angioplastia com Balão/instrumentação , Artéria Carótida Primitiva/anormalidades , Artéria Carótida Interna , Estenose das Carótidas/terapia , Stents , Artéria Subclávia/anormalidades , Idoso , Angiografia Digital , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/diagnóstico , Humanos , Angiografia por Ressonância Magnética , Masculino , Artéria Subclávia/diagnóstico por imagem , Resultado do Tratamento
9.
J Vasc Surg ; 59(3): 781-5, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24246544

RESUMO

OBJECTIVE: Stenting is the preferred, minimally invasive treatment for innominate artery (IA) stenosis or occlusion. Stent fractures in the IA have not been assessed in larger cohorts. In this retrospective study, we examined the frequency and risk factors of IA stent fractures. METHODS: The final analysis included 32 patients (15 women; mean age, 59.4 ± 12.0 years) with 32 balloon-expandable stents (2000 to 2009). In 2010, the patients were asked to come back for a fluoroscopic examination of the implanted stents. Stent fractures and their relationship to atherosclerotic risk factors, lesion characteristics, postprocedural symptoms, and in-stent restenosis were analyzed. Fisher exact test and univariate Cox regression analysis were used in the statistical evaluation. RESULTS: Lesions were >20 mm in 14 patients (44%) or heavily calcified in 13 (41%). The mean follow-up time was 33.4 ± 21.0 months. Postprocedural symptoms were noted in nine patients (28%). Significant restenosis was detected in 22% of the implanted stents, and 11 stent fractures (34%) were found. The prevalence of heavily calcified lesions, postprocedural symptoms, and in-stent restenosis did not differ significantly between groups with and without fracture. Long lesions were associated with an increased incidence of stent fracture (hazard ratio, 5.09; 95% confidence interval, 1.33-19.48; P = .017). No correlation was observed between stent fractures and old age (≥70 years), female gender, smoking, hypertension, hyperlipidemia, or diabetes mellitus. CONCLUSIONS: IA stent fractures are common but seem to have no effect on symptoms and in-stent restenosis rates.


Assuntos
Angioplastia com Balão/instrumentação , Arteriopatias Oclusivas/terapia , Tronco Braquiocefálico , Falha de Prótese , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Arteriopatias Oclusivas/diagnóstico , Tronco Braquiocefálico/diagnóstico por imagem , Constrição Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Radiografia , Recidiva , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/terapia
10.
Arterioscler Thromb Vasc Biol ; 33(1): 152-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23117659

RESUMO

OBJECTIVE: Altered venous biomechanics may contribute to the pathogenesis of venous diseases, and their heritability is less known. METHODS AND RESULTS: Seventy-eight monozygotic twin pairs (aged 42.4 ± 16.8 years) and 24 same-sex dizygotic twin pairs (aged 50.5 ± 16.1 years) were examined. Anteroposterior and mediolateral diameters of the common femoral vein were measured by ultrasonography. Measurements were made both in supine and in standing body positions, with or without controlled forced expiration (Valsalva test). High correlation of diameter, capacity, and distensibility values was found between twin pairs. The univariate heritability (A), shared (C), and unshared (E) environmental effects model has shown 39.3% genetic component of the variance of low pressure, 37.9% of high-pressure venous capacity, and 36.4% of maximal capacity changes, even after elimination of sex, age, and body weight effects. Bivariate Cholesky analysis revealed substantial covariance of inherited body weight and venous capacity components (57.0%-81.4%). CONCLUSIONS: Femoral vein capacity and elasticity depend ≈30% to 40% on genetic factors, and this value in the standing body position can reach 50%. A relatively high genetic covariance was found between weight and femoral vein capacity and elasticity. Our work might yield some new insights into the inheritance of venous diseases that are associated with altered venous biomechanics and help elucidate the involved genes.


Assuntos
Doenças em Gêmeos/genética , Veia Femoral/fisiopatologia , Hemodinâmica/genética , Gêmeos Dizigóticos/genética , Gêmeos Monozigóticos/genética , Doenças Vasculares/genética , Adulto , Idoso , Fenômenos Biomecânicos , Doenças em Gêmeos/diagnóstico , Doenças em Gêmeos/fisiopatologia , Elasticidade , Meio Ambiente , Feminino , Veia Femoral/diagnóstico por imagem , Predisposição Genética para Doença , Hereditariedade , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo , Medição de Risco , Fatores de Risco , Decúbito Dorsal , Ultrassonografia , Doenças Vasculares/diagnóstico , Doenças Vasculares/fisiopatologia , Rigidez Vascular/genética , Pressão Venosa/genética
11.
Lung ; 192(3): 429-34, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24584632

RESUMO

BACKGROUND: While heritability has been shown for daytime sleepiness, the heritability of daytime capillary oxygen saturation (SpO(2)) has not been described in detail. Our aim was to estimate the role of genes and environmental factors--both shared and unshared--in the variation of daytime SpO(2). METHODS: A total of 193 adult healthy twin pairs (138 monozygotic, 55 dizygotic) were recruited in Hungary and in the United States [age = 43.6 ± 15.6 years (mean ± SD)]. SpO(2) was measured by pulse oximetry. Univariate quantitative genetic modeling was performed to decompose the phenotypic variance of the considered parameter into heritability (A), shared (C), and unshared (E) environmental effects. RESULTS: SpO(2) twin correlation in monozygotic twins was stronger than in dizygotic twins (0.30 and -0.15, respectively, p < 0.05). Age-, sex-, country-, and body mass index-adjusted genetic effects accounted for 26 % (95 % CI 10, 45 %) of the variance of SpO(2), and the unshared environmental component explained the remaining 74 % (95 % CI 59, 89 %). No shared environmental influence on SpO(2) was detected. The heritability of SpO(2) was not different between smokers and nonsmokers. CONCLUSION: In summary, individual differences in daytime SpO(2) are explained by genetic and unshared environmental effects. The strong unshared environmental influence highlights the role of prevention of known environmental risk factors.


Assuntos
Ritmo Circadiano/genética , Oxigênio/sangue , Gêmeos Dizigóticos/genética , Gêmeos Monozigóticos/genética , Adulto , Biomarcadores/sangue , Feminino , Interação Gene-Ambiente , Genótipo , Hereditariedade , Humanos , Hungria , Masculino , Pessoa de Meia-Idade , Oximetria , Fenótipo , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Estados Unidos
12.
Acta Radiol ; 55(9): 1112-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24243889

RESUMO

BACKGROUND: Transitional cell carcinoma (TCC) may mimic renal cell carcinoma (RCC) when it develops in a similar location, therefore, differentiation with imaging techniques might be challenging. Preoperative differentiation may have a significant role indicating the type of surgical treatment (nephrectomy vs. ureteronephrectomy). PURPOSE: To retrospectively analyze the differences in the contrast enhancement of TCC and RCC. MATERIAL AND METHODS: Images of 20 RCC and 12 TCC (mean ages, 62.3 ± 14.1 and 67.4 ± 12.0 years, respectively) were analyzed from patients who underwent multiphase computed tomography (CT) examinations following 1.5 mL/kg non-ionic contrast agent administration. Unenhanced corticomedullary (30-45 s), nephrographic (70-90 s), and excretory (300-480 s) phases were imaged. The attenuation characteristics of RCC and TCC were compared to the attenuation of the normal renal cortex. RESULTS: Significant differences were found in the attenuation ratios between RCC or TCC in the corticomedullary (P = 0.040) and nephrographic (P = 0.004) phases using three regions of interest (ROIs) of 10 mm(2) size. If measuring ROIs comprising the complete tumor lesion instead of three small ROIs, no significant difference was observed in the attenuation ratios between RCC in TCC in any phases. CONCLUSION: Our study reports significant attenuation differences between RCC and TCC in the corticomedullary and nephrographic phases by multiphase CT. The findings underscore the importance of multiphase CT in the differentiation of these two different entities. Using multiple small (three) ROIs is more accurate than measuring the whole tumor attenuation.


Assuntos
Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células de Transição/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Idoso , Carcinoma de Células Renais/patologia , Carcinoma de Células Renais/cirurgia , Carcinoma de Células de Transição/patologia , Carcinoma de Células de Transição/cirurgia , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Ácidos Tri-Iodobenzoicos
13.
World J Surg Oncol ; 12: 271, 2014 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-25146111

RESUMO

We report the palliative embolization and functional imaging follow-up of a recurrent shoulder plasmacytoma. The multiple myeloma patient complained of severe pain and discomfort, while he could not tolerate further chemotherapy. The left shoulder lesion had earlier received a high dose of irradiation. Thus, the well-vascularized lesion was embolized via feeding arteries branching off from the left subclavian artery in two sessions. The patient's symptoms rapidly improved post-embolization and the serum free light chain ratio stabilized at a lower level. The follow-up magnetic resonance image showed increased diffusivity in previously restricted tumor foci. This has negatively correlated with the decreased fludeoxyglucose uptake on PET, suggesting post-embolization necrosis.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Embolização Terapêutica , Recidiva Local de Neoplasia/diagnóstico , Plasmocitoma/patologia , Plasmocitoma/terapia , Ombro/patologia , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/tratamento farmacológico , Compostos Radiofarmacêuticos , Resultado do Tratamento , Carga Tumoral
14.
J Res Med Sci ; 19(7): 634-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25364363

RESUMO

BACKGROUND: Complex indeterminate Bosniak category III renal cystic masses are traditionally considered to be malignant in 50%. Our aim was to retrospectively evaluate the attenuation characteristics in multiphase computed tomography (CT) and to determinate the incidence of malignancy based on histological findings on all Bosniak category III renal cystic masses investigated in our department between April 3, 2007 and November 21, 2013. MATERIALS AND METHODS: QUADRIPHASIC MULTIDETECTOR CT IMAGES OF NINETEEN PATIENTS (MEAN AGE: 56.5 ± 16.5 years) with radiologically detected Bosniak category III lesions were reviewed retrospectively. All lesions were surgically removed, and the incidence of malignancy, based on pathological results was determined. RESULTS: Calcification was present in four lesions (21%). The mean largest diameter was 48.7 ± 28.8 mm. All lesions were multilobulated and septated. Of the 19 removed lesions, 16 (84%) were malignant, and 3 (16%) were benign (one inflammatory cyst including a nephrolith, one cystic nephroma and one atypical angiomyolipoma). CT and histological findings of 19 Bosniak III cysts were correlated. CONCLUSION: Our study demonstrated much higher prevalence of malignancy (84%) in radiologically detected Bosniak category III cysts than it has been described before. It may due to the era of modern multidetector CT technology and multiphase protocol.

15.
Cardiovasc Intervent Radiol ; 47(6): 822-828, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38691123

RESUMO

PURPOSE: The aim of this article is to present our experience with minimally-invasive treatment for nulliparous patients with pelvic venous congestion syndrome (PVCS) with special attention to anatomical considerations, procedural and clinical outcome. MATERIALS AND METHODS: In this retrospective, monocentric study, 21 patients with PVCS treated from January 2014 to June 2023 were included. The preprocedural imaging evaluation of PVCS was based on color Doppler ultrasound, contrast-enhanced CT and/or MRI. In all cases insufficient ovarian veins and/or internal iliac branches were occluded with coils and sclerosant. Procedural and clinical outcomes were measured 30 and 90 days after the procedure. RESULTS: Average duration of pelvic pain was 44.8 ± 54.2 months (from 6 to 200) with the mean VAS-recorded pain intensity of 8.5 ± 1.1 (range from 7 to 10 where 0 was "no pain" and 10 "worst pain possible"). Most common symptoms included dysmenorrhea, dyspareunia and dysuria. Complete embolization was observed in in all cases. Targeted vessels included left ovarian vein (13/21, 62%), both ovarian veins (7/21, 33%) and left pudendal with left ovarian (1/21, 5%). Residual PVCS was noted in 1 patient. Mean VAS at 90-days after the procedure was 2.4 ± 1.4 (range from 0 to 6, p < 0.001). Nineteen patients (90%) were satisfied with the clinical outcome (13 "very satisfied", 6 "satisfied") and reported improvement in quality of life. Two patients (9.5%) reported to be "neutral" as the VAS reduction was less than 50%. CONCLUSION: Our study confirms that endovascular coil embolization is safe and effective in treatment of nulliparous patients with PVCS that provides very high rate of clinical success and overall satisfaction.


Assuntos
Embolização Terapêutica , Dor Pélvica , Humanos , Feminino , Estudos Retrospectivos , Adulto , Dor Pélvica/terapia , Embolização Terapêutica/métodos , Resultado do Tratamento , Pelve/irrigação sanguínea , Procedimentos Endovasculares/métodos , Paridade , Adulto Jovem , Ultrassonografia Doppler em Cores , Síndrome
16.
Diagnostics (Basel) ; 14(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38893664

RESUMO

(1) Background: Open-source software tools are available to estimate proton density fat fraction (PDFF). (2) Methods: We compared four algorithms: complex-based with graph cut (GC), magnitude-based (MAG), magnitude-only estimation with Rician noise modeling (MAG-R), and multi-scale quadratic pseudo-Boolean optimization with graph cut (QPBO). The accuracy and reliability of the methods were evaluated in phantoms with known fat/water ratios and a patient cohort with various grades (S0-S3) of steatosis. Image acquisitions were performed at 1.5 Tesla (T). (3) Results: The PDFF estimates showed a nearly perfect correlation (Pearson r = 0.999, p < 0.001) and inter-rater agreement (ICC = from 0.995 to 0.999, p < 0.001) with true fat fractions. The absolute bias was low with all methods (0.001-1%), and an ANCOVA detected no significant difference between the algorithms in vitro. The agreement across the methods was very good in the patient cohort (ICC = 0.891, p < 0.001). However, MAG estimates (-2.30% ± 6.11%, p = 0.005) were lower than MAG-R. The field inhomogeneity artifacts were most frequent in MAG-R (70%) and GC (39%) and absent in QPBO images. (4) Conclusions: The tested algorithms all accurately estimate PDFF in vitro. Meanwhile, QPBO is the least affected by field inhomogeneity artifacts in vivo.

17.
World J Surg Oncol ; 11: 122, 2013 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-23721061

RESUMO

We report the first European case of cerebral iodized lipid embolism post transcatheter arterial embolization for hepatocellular carcinoma. Lipiodol emboli and corresponding multifocal brain ischemia were documented with computed tomography (CT) and magnetic resonance (MR) in the acutely symptomatic patient. Transcranial Doppler sonography with contrast indicated a right-to-left shunt, while on a follow-up CT scan lipiodol embolization was detected in both lungs. Dilated pulmonary vessels and thick vascular channels were seen in the vicinity of the right diaphragm suggestive of pulmonary arteriovenous shunt. The patient symptoms regressed with supportive care alone, but he died 5 months later due to hepatic failure unrelated to the procedure.


Assuntos
Derivação Arteriovenosa Cirúrgica , Carcinoma Hepatocelular/complicações , Embolização Terapêutica/efeitos adversos , Óleo Etiodado/administração & dosagem , Embolia Intracraniana/terapia , Artéria Pulmonar/anormalidades , Veias Pulmonares/anormalidades , Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/terapia , Evolução Fatal , Humanos , Embolia Intracraniana/etiologia , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade
18.
Croat Med J ; 54(6): 550-4, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24382849

RESUMO

AIM: To estimate heritability and environmental effects on renal parenchymal thickness. METHODS: In this twin study, renal parenchymal thickness of 98 Hungarian healthy adult twin pairs (68 monozygotic, 30 dizygotic) without kidney disease was measured bilaterally using renal ultrasound with Esaote MyLab 70X ultrasound machine with low-frequency curved transducers (1-8 MHz). RESULTS: In both monozygotic and dizygotic group there were more women (76.5%). Mean right and left renal parenchymal thickness was 1.32±0.33 cm and 1.62±0.31 cm, respectively. Age- and sex-adjusted heritability of renal parenchymal thickness was 0.0% (95% confidence interval, 0.0 to 50.2%), shared and unshared environmental factor was 30.2% (4.1 to 55.9%) and 69.8% (45.8 to 89.5%), respectively. CONCLUSION: This study shows a negligible role of heritability and an important role of environmental effects in developing renal parenchymal thickness, emphasizing the importance of lifestyle for primary prevention.


Assuntos
Interação Gene-Ambiente , Variação Genética , Córtex Renal/patologia , Nefropatias/genética , Nefropatias/patologia , Estilo de Vida , Doença Aguda , Adulto , Fatores Etários , Doença Crônica , Feminino , Predisposição Genética para Doença , Humanos , Hungria , Córtex Renal/diagnóstico por imagem , Nefropatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Fatores de Risco , Fatores Sexuais , Gêmeos Dizigóticos/genética , Gêmeos Monozigóticos/genética , Ultrassonografia
19.
Radiat Prot Dosimetry ; 199(8-9): 989-994, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37225209

RESUMO

The staff of the Radiation Protection Service of a European clinical center measured the radiation dose by type-tested thermoluminescent dosemeter systems to which the medical staff was exposed, to assess the effectiveness of current procedures and equipment for optimalisation prompted by the requirements EU Basic Safety Standard 2013. There were three participating sites, the Site 1 was an external hospital, whereas Sites 2 and 3 are part of the same clinical center, who provided data regarding their personnel, from technologists, nurses and medical doctors. In this preliminary study, only a low number of cases were available and used to establish a new, more realistic yearly dose constraint, namely 6 (from two) mSv for whole-body effective dose, 15 (from two) mSv for eye lens dose and 300 (from 50) mSv for extremity dose. Furthermore, the state of safety culture and protection equipment was assessed. Collection of the sufficient amount of data for statistical evaluation is ongoing.


Assuntos
Cristalino , Corpo Clínico , Humanos , Extremidades , Hospitais , Doses de Radiação
20.
Diagnostics (Basel) ; 13(21)2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37958249

RESUMO

We aimed to develop a non-linear regression model that could predict the fat fraction of the liver (UEFF), similar to magnetic resonance imaging proton density fat fraction (MRI-PDFF), based on quantitative ultrasound (QUS) parameters. We measured and retrospectively collected the ultrasound attenuation coefficient (AC), backscatter-distribution coefficient (BSC-D), and liver stiffness (LS) using shear wave elastography (SWE) in 90 patients with clinically suspected non-alcoholic fatty liver disease (NAFLD), and 51 patients with clinically suspected metabolic-associated fatty liver disease (MAFLD). The MRI-PDFF was also measured in all patients within a month of the ultrasound scan. In the linear regression analysis, only AC and BSC-D showed a significant association with MRI-PDFF. Therefore, we developed prediction models using non-linear least squares analysis to estimate MRI-PDFF based on the AC and BSC-D parameters. We fitted the models on the NAFLD dataset and evaluated their performance in three-fold cross-validation repeated five times. We decided to use the model based on both parameters to calculate UEFF. The correlation between UEFF and MRI-PDFF was strong in NAFLD and very strong in MAFLD. According to a receiver operating characteristics (ROC) analysis, UEFF could differentiate between <5% vs. ≥5% and <10% vs. ≥10% MRI-PDFF steatosis with excellent, 0.97 and 0.91 area under the curve (AUC), accuracy in the NAFLD and with AUCs of 0.99 and 0.96 in the MAFLD groups. In conclusion, UEFF calculated from QUS parameters is an accurate method to quantify liver fat fraction and to diagnose ≥5% and ≥10% steatosis in both NAFLD and MAFLD. Therefore, UEFF can be an ideal non-invasive screening tool for patients with NAFLD and MAFLD risk factors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA