Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 389(15): 1380-1389, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37634135

RESUMO

BACKGROUND: The role of catheter ablation in patients with symptomatic atrial fibrillation and end-stage heart failure is unknown. METHODS: We conducted a single-center, open-label trial in Germany that involved patients with symptomatic atrial fibrillation and end-stage heart failure who were referred for heart transplantation evaluation. Patients were assigned to receive catheter ablation and guideline-directed medical therapy or medical therapy alone. The primary end point was a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation. RESULTS: A total of 97 patients were assigned to the ablation group and 97 to the medical-therapy group. The trial was stopped for efficacy by the data and safety monitoring board 1 year after randomization was completed. Catheter ablation was performed in 81 of 97 patients (84%) in the ablation group and in 16 of 97 patients (16%) in the medical-therapy group. After a median follow-up of 18.0 months (interquartile range, 14.6 to 22.6), a primary end-point event had occurred in 8 patients (8%) in the ablation group and in 29 patients (30%) in the medical-therapy group (hazard ratio, 0.24; 95% confidence interval [CI], 0.11 to 0.52; P<0.001). Death from any cause occurred in 6 patients (6%) in the ablation group and in 19 patients (20%) in the medical-therapy group (hazard ratio, 0.29; 95% CI, 0.12 to 0.72). Procedure-related complications occurred in 3 patients in the ablation group and in 1 patient in the medical-therapy group. CONCLUSIONS: Among patients with atrial fibrillation and end-stage heart failure, the combination of catheter ablation and guideline-directed medical therapy was associated with a lower likelihood of a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation than medical therapy alone. (Funded by Else Kröner-Fresenius-Stiftung; CASTLE-HTx ClinicalTrials.gov number, NCT04649801.).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Alemanha , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Encaminhamento e Consulta , Resultado do Tratamento
2.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38516791

RESUMO

AIMS: Pulmonary vein isolation (PVI) for catheter ablation of atrial fibrillation (AF) is a time-demanding procedure. High-power short-duration (HPSD) ablation protocols and high-density mapping catheters have recently been introduced to clinical practice. We investigated the impact of high-density mapping and HPSD ablation protocols on procedural timing, efficacy, and safety by comparing different standardized set-ups. METHODS AND RESULTS: Three electrophysiology (EP) laboratory set-ups were analysed: (i) circular catheter for mapping and HPSD ablation with 30/35 W guided by an ablation index (AI); (ii) pentaspline catheter for mapping an HPSD ablation with 50 W guided by an AI; and (iii) pentaspline catheter for mapping and HPSD ablation with 90 W over 4 s using a novel ablation catheter. All patients underwent PVI without additional left atrial ablation strategies. Procedural data and operating intervals in the EP laboratory were systematically analysed. Three hundred seven patients were analysed (30/35 W AI: n = 102, 50 W AI: n = 102, 90 W/4 s: n = 103). Skin-to-skin times [105.3 ± 22.7 (30/35 W AI) vs. 81.4 ± 21.3 (50 W AI) vs. 69.5 ± 12.2 (90 W/4 s) min, P ≤ 0.001] and total laboratory times (132.8 ± 42.1 vs. 107.4 ± 25.7 vs. 95.2 ± 14.0 min, P < 0.001) significantly differed among the study groups. Laboratory interval analysis revealed significant shortening of mapping and ablation times. Arrhythmia-free survival after 12 months was not different among the study groups (log-rank P = 0.96). CONCLUSION: The integration of high-density mapping and HPSD protocols into an institutional AF ablation process resulted in reduced procedure times without compromising safety or efficacy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fluxo de Trabalho , Átrios do Coração , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva
3.
Heart Vessels ; 39(5): 427-437, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38189924

RESUMO

BACKGROUND: Data comparing remote magnetic catheter navigation (RMN) with manual catheter navigation in combination with contact force sensing (MCN-CF) ablation of atrial fibrillation (AF) is lacking. The primary aim of the present retrospective comparative study was to compare the outcome of RMN versus (vs.) MCN-CF ablation of AF with regards to AF recurrence. Secondary aim was to analyze periprocedural risk, ablation characteristics and repeat procedures. METHODS: We retrospectively analyzed 452 patients undergoing a total of 605 ablations of AF: 180 patients were ablated using RMN, 272 using MCN-CF. RESULTS: Except body mass index there was no significant difference between groups at baseline. After a mean 1.6 ± 1.6 years of follow-up and 1.3 ± 0.4 procedures, 81% of the patients in the MCN-CF group remained free of AF recurrence compared to 53% in the RMN group (P < 0.001). After analysis of 153 repeat ablations (83 MCN-RF vs. 70 RMN; P = 0.18), there was a significantly higher reconnection rate of pulmonary veins after RMN ablation (P < 0.001). In multivariable Cox-regression analysis, RMN ablation (P < 0.001) and left atrial diameter (P = 0.013) was an independent risk factor for AF recurrence. Procedure time, radiofrequency application time and total fluoroscopy time and fluoroscopy dose were higher in the RMN group without difference in total number of ablation points. Complication rates did not differ significantly between groups (P = 0.722). CONCLUSIONS: In our retrospective comparative study, the AF recurrence rate and pulmonary vein reconnection rate is significantly lower with more favorable procedural characteristics and similar complication rate utilizing MCN-CF compared to RMN.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fenômenos Magnéticos , Veias Pulmonares/cirurgia
4.
Europace ; 25(4): 1392-1399, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36815300

RESUMO

AIMS: Atrial fibrillation (AF) ablation protocols using energy delivery with very high power and short duration (vHPSD) have been introduced to improve lesion formation. This study reports procedural data of vHPSD ablation in AF patients and analyses characteristics of ablation-induced left atrial (LA) scar formation from cardiac magnetic resonance imaging (MRI). METHODS AND RESULTS: Sixty consecutive patients undergoing index pulmonary vein isolation following our institutional Q4U-AF workflow were prospectively enrolled. Ablation was conducted using a contact force sensing catheter allowing for vHPSD ablation using a temperature-controlled ablation mode. Thirty patients underwent cardiac late gadolinium enhancement MRI of the LA 3 months after ablation to assess LA scar. Mean procedural duration was 66.5 ± 14.8 min. Mean ablation time was 4.7 ± 0.9 min with a mean number of 69.9 ± 14.2 applications. First-pass isolation was achieved in 51 patients (85%) for the right pulmonary veins (RPVs), in 37 patients (61.7%) for the left pulmonary veins (LPVs), and in 34 patients (56.7%) for both pulmonary veins (PVs). Magnetic resonance imaging at 3 months post-ablation demonstrated a mean scar width of 14.4 ± 2.6 mm around RPVs and 11.9 ± 1.9 mm at LPVs (P > 0.05). Complete PV encirclement was observed in 76.7% for RPVs, in 76.7% for LPVs, and in 66.7% for both PV pairs. During a mean follow-up of 4.7 ± 1.4 months, arrhythmia recurrence was observed in 3.3% of the patients. CONCLUSION: Pulmonary vein isolation following a novel vHPSD workflow resulted in short procedure duration and high acute and mid-term efficacy. Magnetic resonance imaging demonstrated durable and transmural PV lesions with homogeneous and contiguous scar formation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Meios de Contraste , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Cicatriz/patologia , Fluxo de Trabalho , Gadolínio , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Espectroscopia de Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Veias Pulmonares/patologia , Resultado do Tratamento , Recidiva
5.
Europace ; 25(2): 600-609, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36504238

RESUMO

AIMS: Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients' heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. METHODS AND RESULTS: Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (Ï°>0.8; P < 0.001*). CONCLUSION: The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Humanos , Adulto , Criança , Feminino , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Masculino , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirurgia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Ablação por Cateter/métodos , Feixe Acessório Atrioventricular/diagnóstico , Feixe Acessório Atrioventricular/cirurgia , Eletrocardiografia/métodos , Algoritmos
6.
Pacing Clin Electrophysiol ; 46(12): 1553-1564, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37885302

RESUMO

BACKGROUND: Targeting individual sources identified during atrial fibrillation (AF) has been used as an ablation strategy with varying results. OBJECTIVE: Aim of this study was to evaluate the relationship between regions of interest (ROIs) from CARTOFINDER (CF) mapping and atrial cardiomyopathy from late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR). METHODS: Twenty consecutive patients underwent index catheter ablation for persistent AF (PERS AF). Pre-processed LGE CMR images were merged with the results from CF mapping to visualize harboring regions for focal and rotational activities. Atrial cardiomyopathy was classified based on the four Utah stages. RESULTS: Procedural success was achieved in all patients (n = 20, 100%). LGE CMR revealed an intermediate amount of 21.41% ± 6.32% for LA fibrosis. ROIs were identified in all patients (mean no ROIs per patient n = 416.45 ± 204.57). A tendency towards a positive correlation between the total amount of atrial cardiomyopathy and the total number of ROIs per patient (regression coefficient, ß = 10.86, p = .15) was observed. The degree of fibrosis and the presence of ROIs per segment showed no consistent spatial correlation (posterior: ß = 0.36, p-value (p) = .24; anterior: ß = -0.08, p = .54; lateral: ß = 0.31, p = 39; septal: ß = -0.12; p = .66; right PVs: ß = 0.34, p = .27; left PVs: ß = 0.07, p = .79; LAA: ß = -0.91, p = .12). 12 months AF-free survival was 70% (n = 14) after ablation. CONCLUSION: The presence of ROIs from CF mapping was not directly associated with the extent and location of fibrosis. Further studies evaluating the relationship between focal and rotational activity and atrial cardiomyopathy are mandatory.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Humanos , Ablação por Cateter/métodos , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração , Imageamento por Ressonância Magnética/métodos
7.
J Cardiovasc Electrophysiol ; 33(12): 2517-2527, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36104929

RESUMO

INTRODUCTION: Approaches applying higher energy levels for shorter periods (high power short duration, HPSD) to improve lesion formation for atrial fibrillation (AF) ablation have been introduced. This single-center study aimed to compare the efficacy, safety, and lesion formation using the novel DiamondTemp (DT) catheter or an ablation index (AI)-guided HPSD ablation protocol using a force-sensing catheter with surround-flow irrigation. METHODS: One hundred thirteen consecutive patients undergoing radiofrequency-guided catheter ablation (RFCA) for AF were included. Forty-five patients treated with the DT catheter (50 W, 9 s), were compared to 68 consecutive patients undergoing AI-guided ablation (AI anterior 550; AI posterior 400) adherent to a 50 W HPSD protocol. Procedural data and AF recurrence were evaluated. RESULTS: Acute procedural success was achieved in all patients (n = 113, 100%). DT-guided AF ablation was associated with a longer mean procedure duration (99.10 ± 28.30 min vs. 78.24 ± 25.55, p < .001) and more RF applications (75.24 ± 30.76 min vs. 61.27 ± 14.06, p = .019). RF duration (792.13 ± 311.23 s vs. 1035.54 ± 287.24 s, p < .001) and fluoroscopy dose (183.81 ± 178.13 vs. 295.80 ± 247.54 yGym2 , p = .013) were lower in the DT group. AI-guided HPSD was associated with a higher AF-free survival rate without reaching statistical significance (p = .088). Especially patients with PERS AF (p = .009) as well as patients with additional atrial arrhythmia substrate (p = .002) benefited from an AI-guided ablation strategy. CONCLUSION: Temperature- and AI- controlled HPSD RFCA using 50 W was safe and effective. AI-guided HPSD ablation seems to be associated with shorter procedure durations and fewer RF applications. Particularly in advanced AF, freedom from AF-recurrence may be improved using an AI-guided HPSD approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Veias Pulmonares/cirurgia , Temperatura , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
8.
J Cardiovasc Electrophysiol ; 33(7): 1383-1390, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35502754

RESUMO

AIMS: Cryoballoon-guided pulmonary vein isolation (CB-PVI) for symptomatic atrial fibrillation (AF) has become an established treatment option with encouraging results in terms of safety and efficacy. Data reporting on long-term data beyond a follow-up (FU) period of 5 years is scarce. This prospective study aimed to evaluate very long-term outcome after CB-PVI for AF. METHODS: Data from consecutive patients treated with CB-PVI for symptomatic and drug refractory AF between 2005 and 2012 were analyzed. Patients with a FU of ≥9 years after index CB-PVI were included. All patients were continuously followed-up in our outpatient clinic. Arrhythmia recurrence was defined as AF or atrial tachycardia (AT) lasting >30 s beyond a 3-month blanking period. RESULTS: A total of 385 patients (71% male) were included. Mean age was 58 ± 10 years and paroxysmal AF was present in 93% of patients. Mean FU duration was 124 ± 24 months. At the end of the observational period, 73% of all patients were in stable sinus rhythm after a mean of 2 ± 0.8 ablation procedures. Patients with AF/AT recurrence were older (60 ± 8 vs. 57 ± 10 years; p = .019), had a higher CHA2 DS2 -Vasc Score (2.47 ± 1.46 vs. 1.98 ± 1.50; p = .01) and presented with a larger left atrium (LA)-diameter (43 ± 5.6 vs. 40 ± 5.1 mm; p = .002). The LA-diameter was also a significant predictor for AF/AT recurrence after CB-PVI (odds ratio: 0.939, 95% confidence interval: [0.886, 0.992], p = .03). CONCLUSIONS: CB-PVI as index procedure for AF ablation resulted in favorable long-term outcome in symptomatic AF. CB-PVI might be recommended as interventional therapy in patients with lower LA remodeling.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
9.
Rev Cardiovasc Med ; 23(4): 118, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-39076243

RESUMO

Following its introduction into clinical practice, the cryoballoon (CB) has proved to be an alternative for pulmonary vein isolation (PVI) in patients with paroxysmal and persistent atrial fibrillation (AF). In comparison with the standard radiofrequency procedure, the CB method results in a shorter procedure time and learning curve as well as a higher degree of reproducibility. A new cryoballoon (NCB) was recently introduced on the market. In this review, we addressed the following questions: Is the new system technically similar to the previous one? Is there a difference in terms of periprocedural parameters? Are acute success and complication rates similar? Is the learning curve different?

10.
Pacing Clin Electrophysiol ; 45(1): 149-153, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34564879

RESUMO

Limited data exists about the effectiveness of the coronary sinus reducer (CSR) device in patients with angina pectoris and atrial fibrillation (AF). This case demonstrates beneficial effects of AF ablation in a patient with CSR. We report four major findings: Rhythm control has a relevant effect on angina pectoris symptoms in patients with coronary artery disease and AF. In these patients, AF ablation should be considered at an early stage. Patients with persistent angina pectoris and CSR may require sinus rhythm for an optimal effect of the device. Selected coronary sinus (CS) interventions can still be performed through the mesh of the CSR device.


Assuntos
Angina Pectoris/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Seio Coronário/cirurgia , Stents , Idoso , Eletrocardiografia , Humanos , Masculino
11.
Pacing Clin Electrophysiol ; 45(1): 14-22, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34687054

RESUMO

BACKGROUND: Data comparing remote magnetic catheter navigation (RMN) with manual catheter navigation (MCN) ablation of atrial fibrillation (AF) is lacking. The aim of the present prospective observational study was to compare the outcome of RMN versus (vs.) MCN ablation of AF with regards to AF recurrence. METHODS: The study comprised 667 consecutive patients with a total of 939 procedures: 287 patients were ablated using RMN, 380 using MCN. RESULTS: There was no significant difference between the groups at baseline. After 2.3 ± 2.3 years of follow-up, 23% of the patients in the MCN group remained free of AF recurrence compared to 13% in the RMN group (p < .001). After analysis of 299 repeat ablations (133 MCN, 166 RMN) there was a significantly higher reconnection rate of pulmonary veins after RMN ablation p < .001). In multivariable Cox-regression analysis, RMN ablation was an independent risk factor for AF recurrence besides age, persistent AF, number of isolated pulmonary veins, and left atrial diameter. Procedure time, radiofrequency application time and total number of ablation points were higher in the RMN group. Total fluoroscopy time and total fluoroscopy dose were significantly lower for RMN. Complication rates did not differ between groups (p = .842), although the incidence of significant pericardial effusion was higher in the MCN group (seven cases vs. three in RMN group). CONCLUSIONS: In our study the AF recurrence rate and pulmonary vein reconnection rate is higher after RMN ablation with a similar complication rate but reduced probability of pericardial effusion when compared to MCN.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Magnetismo/instrumentação , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Recidiva , Reoperação/estatística & dados numéricos , Fatores de Risco
12.
Pacing Clin Electrophysiol ; 45(8): 922-929, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35716400

RESUMO

INTRODUCTION: Recently, a novel steerable sheath allowing its real-time visualization within a 3D-mapping system was introduced to facilitate atrial fibrillation (AF) ablation. AIM: This study aimed to assess safety and efficacy of AF ablation using the visualized sheath and to compare its performance with a matched control group of patients who received ablation with conventional and non-visualized sheaths. METHODS: The study included consecutive patients between 09/2019 and 02/2021 who underwent routine AF ablation using the visualized sheath. Patients were regularly followed-up in our outpatient's clinic. Arrhythmia recurrence was defined as any atrial fibrillation (AF)/ atrial tachycardia (AT) episode lasting > 30 s after a blanking period of 3 months. RESULTS: A total number of 100 patients undergoing ablation using the visualized sheath were compared to a group of 99 matched patients. No major complications were observed. Total procedure duration (108 ± 22 min vs. 112 ± 12 min; p = 0.045), fluoroscopy time (7 ± 3 min vs. 10 ± 5 min; p < 0.001) and -dose (507 ± 501 cGy*cm2 vs. 783 ± 433 cGy*cm2 ; p < 0.001) were significantly lower using the visualized sheath. The benefit in terms of procedure duration was mainly driven by a shortened left atrial dwell time (73 ± 13 min vs. 79 ± 12 min; p = 0.001). During a mean follow-up of 12 months, the overall procedural success was 85% in the visualized sheath group versus 83% in the control group (p = 0.948). CONCLUSION: AF ablation using the novel visualized sheath is safe and effective and leads to a measurable decrease of procedure duration and radiation exposure. The integration of the novel sheath might help to further improve safety and efficacy of AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Cateter/métodos , Fluoroscopia/métodos , Átrios do Coração , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
Hum Mutat ; 41(11): 1931-1943, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32840935

RESUMO

Mutations in RBM20 encoding the RNA-binding motif protein 20 (RBM20) are associated with an early onset and clinically severe forms of cardiomyopathies. Transcriptome analyses revealed RBM20 as an important regulator of cardiac alternative splicing. RBM20 mutations are especially localized in exons 9 and 11 including the highly conserved arginine and serine-rich domain (RS domain). Here, we investigated in several cardiomyopathy patients, the previously described RBM20-mutation p.Pro638Leu localized within the RS domain. In addition, we identified in a patient the novel mutation p.Val914Ala localized in the (glutamate-rich) Glu-rich domain of RBM20 encoded by exon 11. Its impact on the disease was investigated with a novel TTN- and RYR2-splicing assay based on the patients' cardiac messenger RNA. Furthermore, we showed in cell culture and in human cardiac tissue that mutant RBM20-p.Pro638Leu is not localized in the nuclei but causes an abnormal cytoplasmic localization of the protein. In contrast the splicing deficient RBM20-p.Val914Ala has no influence on the intracellular localization. These results indicate that disease-associated variants in RBM20 lead to aberrant splicing through different pathomechanisms dependent on the localization of the mutation. This might have an impact on the future development of therapeutic strategies for the treatment of RBM20-induced cardiomyopathies.


Assuntos
Cardiomiopatias/genética , Mutação , Proteínas de Ligação a RNA/genética , Adulto , Processamento Alternativo , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Linhagem
15.
J Cardiovasc Electrophysiol ; 31(11): 2857-2864, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33345455

RESUMO

INTRODUCTION: Cryoballoon (CB)-guided ablation of atrial fibrillation (AF) is established in symptomatic AF patients. This study sought to determine the safety and efficacy of CB pulmonary vein isolation (PVI) in young adults. METHODS AND RESULTS: A total of 93 consecutive patients aged <45 years referred to our center for AF ablation were included in this observational study. All patients received CB-guided PVI according to a standardized institutional protocol. Follow-up was performed in our outpatient clinic using 72-h Holter monitoring and periodic telephone interview. Recurrence was defined as any AF/atrial tachycardia (AT) episode >30 s following a 3-month blanking period. A propensity matched control group consisting of patients older than 45 years were used for further evaluation. Mean age was 35 ± 7 years, 22% suffered from persistent AF, 85% were male. Mean follow-up was 2.6 ± 2 years. At the end of the observational period, 83% of patients were free of any AF/AT episodes. There was an excellent overall 12-month success rate of 92%. In comparison to a matched group the overall recurrence rate was noticeably lower in the young group (15% vs. 27%). Increasing age was associated with a hazard ratio of 1.16 for recurrence. In a multivariate analysis model, left atrial diameter remained as significant predictor of AF/AT recurrence. The complication rate was low, no permanent phrenic nerve palsy was observed. CONCLUSION: CB-guided PVI in young adults is safe and effective with favorable long-term results. It may be considered as first-line therapy in this relatively healthy population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criança , Criocirurgia/efeitos adversos , Humanos , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento , Adulto Jovem
16.
Europace ; 22(11): 1697-1702, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32778877

RESUMO

AIMS: Pacing the specific conduction system like the Bundle of His (HB) can lead to more physiologic activation patterns compared to traditional right ventricular apical pacing. The aim of this study was to estimate the feasibility and value of electroanatomical mapping (EAM) for HB pacing during the learning curve and its impact on procedural outcome. METHODS AND RESULTS: Fifteen consecutive patients were treated using EAM of the His bundle region before implantation. Voltage and activation maps of HB potentials were performed. The activation time from His potential to R wave (ECG-reference) was measured and correlated to the HV interval. The atrial and ventricular potentials were blended so the active window could only see the His potential. After completing the activation map, it was transformed into a peak-to-peak voltage map of the HB. With reversed black and white colour scale, the exact point of the maximal His signal amplitude was visualized. Procedural data for the implantation were analysed using this innovative approach. The average total procedural time and fluoroscopy time was 88.2 ± 19.1 min and 10.9 ± 4.5 min, respectively. The 3D mapping time was 18.4 ± 5.1 min. The 13.9 ± 5.1 His potential points were needed in average to complete the map. No periprocedural complications were seen in this cohort. In 86.7% of cases, His bundle pacing was successful. The average threshold for the His bundle stimulation and the R-wave amplitude was 1.62 ± 1 V (@1.0 ms) and 4.8 ± 3.2 mV, respectively. The pacing impedance was 513.5 ± 102.8 Ω. Average paced QRS complex width was 116.9 ± 20.3ms. On average 2.6 ± 1.6 lead positions were targeted to find the optimal pacing site. CONCLUSION: Electroanatomical mapping-guided implantation of His-bundle leads can facilitate the identification of optimal pacing sites and allow to minimize procedure and fluoroscopy times even during the phase of the learning curve.


Assuntos
Fascículo Atrioventricular , Curva de Aprendizado , Estimulação Cardíaca Artificial , Eletrocardiografia , Fluoroscopia , Humanos , Resultado do Tratamento
17.
Europace ; 20(6): 963-970, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016784

RESUMO

Aims: Therapy with an implantable cardioverter defibrillator (ICD) is established for the prevention of sudden cardiac death (SCD) in high risk patients. We aimed to determine the effectiveness of primary prevention ICD therapy by analysing registry data from 14 centres in 11 European countries compiled between 2002 and 2014, with emphasis on outcomes in women who have been underrepresented in all trials. Methods and results: Retrospective data of 14 local registries of primary prevention ICD implantations between 2002 and 2014 were compiled in a central database. Predefined primary outcome measures were overall mortality and first appropriate and first inappropriate shocks. A multivariable model enforcing a common hazard ratio for sex category across the centres, but allowing for centre-specific baseline hazards and centre specific effects of other covariates, was adjusted for age, the presence of ischaemic cardiomyopathy or a CRT-D, and left ventricular ejection fraction ≤25%. Of the 5033 patients, 957 (19%) were women. During a median follow-up of 33 months (IQR 16-55 months) 129 women (13%) and 807 men (20%) died (HR 0.65; 95% CI: [0.53, 0.79], P-value < 0.0001). An appropriate ICD shock occurred in 66 women (8%) and 514 men (14%; HR 0.61; 95% CI: 0.47-0.79; P = 0.0002). Conclusion: Our retrospective analysis of 14 local registries in 11 European countries demonstrates that fewer women than men undergo ICD implantation for primary prevention. After multivariate adjustment, women have a significantly lower mortality and receive fewer appropriate ICD shocks.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica , Fatores Sexuais , Idoso , Arritmias Cardíacas/complicações , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Falha de Equipamento/estatística & dados numéricos , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Prevenção Primária/métodos , Sistema de Registros/estatística & dados numéricos , Estudos Retrospectivos
19.
Vascular ; 26(1): 99-110, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28820357

RESUMO

Objectives The aim of this study was to investigate the possible benefits from computed tomography scans of patients with a suspected pulmonary artery embolism with a focus on relevant extravascular findings. Methods A total of 400 consecutive computed tomography pulmonary angiographies were evaluated. Computed tomography scans were analyzed in detail for the presence of pulmonary artery embolisms, as well as any other findings. Extra-artery discoveries were classified into none-relevant (Group A), intermediate (Group B), or relevant (Group C) findings. Results Aggregated computed tomography pulmonary angiographies detected other diagnosis than pulmonary artery embolism in 236 patients (59%). There were 1950 non-pulmonary artery embolism findings (4.9 per patient; n = 397). In the pulmonary artery embolism group, there were 447 extra-pulmonary artery embolism findings (5.2 per patient; n = 86) and in the non-pulmonary artery embolism group, 1503 findings (4.8 per patient; n = 311). Patients with pulmonary artery embolism had a significantly higher rate of pro-coagulate risk factors ( p < 0.001). Conclusions Computed tomography pulmonary angiographies may help to identify further diagnoses. This study represents a retrospective review of a single center experience for incidental computed tomography findings during pulmonary artery embolism work-up and emphasizes the importance of analyzing the whole field-of-view.


Assuntos
Angiografia por Tomografia Computadorizada , Achados Incidentais , Tomografia Computadorizada Multidetectores , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Embolia Pulmonar/sangue , Estudos Retrospectivos
20.
Vascular ; 26(1): 27-38, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28587578

RESUMO

Background The aim of this study was to assess the prevalence and clinical significance of extra-vascular findings in patients undergoing magnetic resonance angiography of the abdomen, pelvis and lower extremities. Materials and methods Three hundred fifty-two patients underwent abdominal, pelvic and lower extremity 1.5 T magnetic resonance angiography. Clinically relevant vascular and extra-vascular findings were identified. Relevant vascular findings were classified as stenosis, occlusion, aneurysm, sclerosis, dissection or vasculitis. Relevant extra-vascular findings were categorized as 'safe' (Group A), intermediate - requiring additional investigation - (Group B) and malignant/endangering - requiring change of therapy (Group C). Results A total of 2152 clinically relevant vascular findings was identified (6.1/patient). The most frequent vascular finding was femoral artery stenosis (10.6%). Four hundred fifty-one extra-vascular findings were observed (1.3/patient) and classified into Group A (78%), Group B (19.5%) and Group C findings (2.4%). The most frequent malignant findings were lung cancer, lymphoma, osteosarcoma, hepatocellular carcinoma and renal cell carcinoma (7/352 patients). Conclusions Extravascular findings are frequently encountered in magnetic resonance angiography performed for vascular indications. Clinically relevant findings are seen in a substantial part of patients and should prompt further diagnostic work-up.


Assuntos
Abdome/irrigação sanguínea , Achados Incidentais , Extremidade Inferior/irrigação sanguínea , Angiografia por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Pelve/irrigação sanguínea , Doenças Vasculares/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA