Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38736246

RESUMO

BACKGROUND: Stent implantation has become standard of care in older children and adults for treatment of branch pulmonary artery stenosis (BPAS) and coarctation aorta (CoAo). There are no stents approved or available for infants that have the potential to be dilated to adult diameters. The Minima stent was designed to fulfill this unmet need. METHODS: Multicenter, prospective, nonrandomized early feasibility study evaluating safety and effectiveness of the Minima stent for treatment of BPAS and CoAo. Primary endpoints included: (1) successful deployment across lesion, (2) stenosis relief defined by an increase in angiographic diameter of >50% and (3) freedom from stent explant, embolization or migration at 30 days and 6 months. RESULTS: Between 2/2022 and 5/2022, 10 pts underwent Minima stent implantation with a median age and weight of 9 months (4-43 months) and 7.6 kg (5.1-16.9 kg). Procedural success and predefined stenosis relief was achieved in all cases (CoAo [n = 4], BPAS [n = 6]). Adverse events occurred in 3 pts: transient diminished lower extremity pulse (n = 2), distal stent on-balloon displacement successfully managed in the catheterization suite (n = 1). There were no deaths or major adverse events. All patients were free from stent explant and migration at 30 days and 6 months with no evidence for significant restenosis at latest follow-up. CONCLUSIONS: Implantation of the Renata Minima stent was safe and effective for the treatment of BPAS and CoAo in this small cohort of infants and young children during early follow-up. Based on these early results, an expanded study with longer follow-up is warranted.

2.
J Pediatr ; 263: 113712, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37659587

RESUMO

OBJECTIVE: To describe the current practices in invasive patent ductus arteriosus (PDA) closure (surgical ligation or transcatheter occlusion) in very low birth weight (VLBW) infants and changes in patient characteristics and outcomes from 2016 to 2021 among US children's hospitals. STUDY DESIGN: We evaluated a retrospective cohort of VLBW infants (birth weight 400-1499 g and gestational age 22-31 weeks) who had invasive PDA closure within 6 months of age from 2016 to 2021 in children's hospitals in the Pediatric Health Information System. Changes in patient characteristics and outcomes over time were evaluated using generalized linear models and generalized linear mixed models. RESULTS: 2418 VLBW infants (1182 surgical ligation; 1236 transcatheter occlusion) from 42 hospitals were included. The proportion of infants receiving transcatheter occlusion increased from 17.2% in 2016 to 84.4% in 2021 (P < .001). In 2021, 28/42 (67%) hospitals had performed transcatheter occlusion in > 80% of their VLBW infants needing invasive PDA closure, compared with only 2/42 (5%) in 2016. Although median postmenstrual age (PMA) at PDA closure did not change for the overall cohort, PMA at transcatheter occlusion decreased from 38 weeks in 2016 to 31 weeks by 2020, P < .001. Among those infants not intubated prior to PDA closure, extubation within 3 days postprocedure increased over time (yearly adjusted odds ratios of 1.26 [1.08-1.48]). Length of stay and mortality did not change over time. CONCLUSION: We report rapid adoption of transcatheter occlusion for PDA among VLBW infants in US children's hospitals over time. Transcatheter occlusions were performed at younger PMA over time.


Assuntos
Permeabilidade do Canal Arterial , Recém-Nascido , Lactente , Humanos , Criança , Estados Unidos , Permeabilidade do Canal Arterial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Recém-Nascido de muito Baixo Peso , Peso ao Nascer
3.
Pediatr Cardiol ; 44(1): 132-140, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36029321

RESUMO

The aim of the study was to determine the variables associated with high-quality (HQ) versus low-quality (LQ) three-dimensional rotational angiography (3DRA) and create guides for optimization of approach to 3DRA in congenital cardiac catheterization (CCC). CCC has adopted 3DRA as a mainstay, but there has not been systematic analysis of approach to and factors associated with HQ 3DRA. This was a single-center, retrospective study of 3DRAs using Canon Infinix-I platform. Reconstructions were graded by 3 interventionalists. Quality was dichotomized into HQ and LQ. Univariable analyses and multivariable logistic regression models were performed. From 8/2016 to 12/2018, 208 3DRAs were performed in 195 CCCs; median age 7 years (2, 16), weight 23 kg (12, 57). The majority of 3DRAs were performed in patients with biventricular physiology (N = 137, 66%) and in pulsatile sites (N = 144, 69%). HQ 3DRA (N = 182, 88%) was associated with greater total injection volume [2.20 mL/kg (1.44, 3.29) vs. 1.62 mL/kg (1.10, 1.98), p = 0.005] and more dilute contrast solution [60% (50, 100) vs. 100% (60, 100), p = 0.007], but not with contrast volume administered (p = 0.2) on univariable analysis. On multivariable logistic regression, HQ 3DRA was significantly associated with patient weight [OR 0.97 (95% CI (0.94, 0.99), p = 0.018], total injection volume [OR 1.04 (95% CI 1.01, 1.07) p = 0.011], and percent contrast solution [OR 0.97 (95% CI 0.95, 1.00), p = 0.022]. These data resulted in creation of scatter plots and a novel 3DRA Nomogram for estimating the probability of HQ 3DRA. This is the first study to create evidence-based contrast dose guides and nomogram for 3DRA in CCC. HQ 3DRA was associated with lower weight, higher total injection volumes, and more dilute contrast solution.


Assuntos
Imageamento Tridimensional , Procedimentos de Cirurgia Plástica , Humanos , Criança , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Angiografia/métodos , Cateterismo Cardíaco/métodos
4.
Pediatr Cardiol ; 43(5): 986-994, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34981140

RESUMO

To date, there has been limited investigation of bioabsorbable atrial septal defect (ASD) or patent foramen ovale (PFO) closure devices using clinically relevant large animal models. The purpose of this study is to explore the function and safety of a bioabsorbable ASD occluder (BAO) system for PFO and/or secundum ASD transcatheter closure. Using a sheep model, the intra-atrial septum was evaluated by intracardiac echo (ICE). If a PFO was not present, atrial communication was created via transseptal puncture. Device implantation across the intra-atrial communication was performed with fluoroscopic and ICE guidance. Our 1st generation device consisted of a main structure of thin Poly(L-lactide-co-epsilon-caprolactone) (PLCL) fibers, and an internal Poly glycolic acid (PGA) fabric. Four procedures validated procedure feasibility. Subsequently, device design was modified for improved transcatheter delivery. The 2nd generation device has a two-layered structure and was implanted in six sheep. Results showed procedural success in 9/10 (90%) animals. With deployment, the 1st generation device did not reform into its original disk shape and did not conform nicely along the atrial septum. The 2nd generation device was implanted in six animals, 3 out of 6 survived out to 1 year. At 1 year post implantation, ICE confirmed no residual shunting. By necropsy, biomaterials had partially degraded, and histology of explanted samples revealed significant device endothelialization and biomaterial replacement with a collagen layer. Our results demonstrate that our modified 2nd generation BAO can be deployed via minimally invasive percutaneous transcatheter techniques. The BAO partially degrades over 1 year and is replaced by host native tissues. Future studies are needed prior to clinical trials.


Assuntos
Forame Oval Patente , Comunicação Interatrial , Dispositivo para Oclusão Septal , Implantes Absorvíveis , Animais , Cateterismo Cardíaco/métodos , Seguimentos , Forame Oval Patente/cirurgia , Átrios do Coração , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Humanos , Ovinos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 98(1): 128-136, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33909945

RESUMO

BACKGROUND: Covered stent correction of sinus venosus ASDs (SVASD) is a relatively new technique. Challenges include anchoring a sufficiently long stent in a nonstenotic superior vena cava (SVC) and expanding the stent at the wider SVC-RA junction without obstructing the anomalous right upper pulmonary vein (RUPV). The 10-zig covered Cheatham-platinum (CCP) stent has the advantage of being available in lengths of 5-11 cm and dilatable to 34 mm in diameter. METHODS: An international registry reviewed the outcomes of 10-zig CCP stents in 75 patients aged 11.4-75.9 years (median 45.4) from March 2016. Additional stents were used to anchor the stent in the SVC or close residual shunts in 33/75. An additional stent was placed in 4/5 (80%) with 5/5.5 cm CCPs, 18/29 (62%) with 6 cm CCPs, 5/18 (28%) with 7 cm CCPs, 5/22 (23%) with 7.5/8 cm CCPs and 0/1 with an 11 cm CCP. A "protective" balloon catheter was inflated in the RUPV in 17. RESULTS: Early stent embolization in two patients required surgical removal and defect repair and tamponade was drained in one patient. The CT at 3 months showed occlusion of the RUPV in one patient. Follow up is from 2 months to 5.1 years (median 1.8 years). QP:QS has reduced from 2.5 ± 0.5 to 1.2 ± 0.36 (p < .001) and RVEDVi from 149.1 ± 35.4 to 95.6 ± 21.43 ml/m2 (p < .001). CONCLUSIONS: Ten-zig CCPs of 7-8 cm appear to provide reliable SVASD closure with a low requirement for additional stents. Careful selection of patients and meticulous attention to detail is required to avoid complications.


Assuntos
Comunicação Interatrial , Platina , Humanos , Sistema de Registros , Stents , Resultado do Tratamento , Veia Cava Superior
6.
Pediatr Cardiol ; 42(6): 1258-1274, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34195869

RESUMO

Transcatheter closure of patent ductus arteriosus (PDA) in premature infants is a feasible, safe, and an effective alternative to surgical ligation and may be performed with an implant success rate of 97%. Major procedural complications related to transcatheter PDA closure in extremely low birth weight (ELBW) infants are relatively infrequent (< 3%) ,but may be associated with a fatality if not optimally managed. Operators performing transcatheter PDA closures should be knowledgeable about these potential complications and management options. Prompt recognition and treatment are often necessary to avoid serious consequences. With strict guidelines on operator training, proctoring requirements, and technical refinements, transcatheter PDA closure in ELBW infants can be performed safely with low complication rates. This article summarizes the consensus guidelines put forward by a panel of physicians for the prevention and management of periprocedural complications of transcatheter PDA closure with the Amplatzer Piccolo Occluder in ELBW infants.


Assuntos
Consenso , Permeabilidade do Canal Arterial/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Guias de Prática Clínica como Assunto , Dispositivo para Oclusão Septal/efeitos adversos , Humanos , Lactente , Recém-Nascido de Peso Extremamente Baixo ao Nascer
7.
Cardiol Young ; 31(9): 1407-1411, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33597057

RESUMO

BACKGROUND: Three-dimensional printing is increasingly utilised for congenital heart defect procedural planning. CT or MR datasets are typically used for printing, but similar datasets can be obtained from three-dimensional rotational angiography. We sought to assess the feasibility and accuracy of printing three-dimensional models of CHD from rotational angiography datasets. METHODS: Retrospective review of CHD catheterisations using rotational angiography was performed, and patient and procedural details were collected. Imaging data from rotational angiography were segmented, cleaned, and printed with polylactic acid on a Dremel® 3D Idea Builder (Dremel, Mount Prospect, IL, USA). Printing time and materials' costs were captured. CT scans of printed models were compared objectively to the original virtual models. Two independent, non-interventional paediatric cardiologists provided subjective ratings of the quality and accuracy of the printed models. RESULTS: Rotational angiography data from 15 catheterisations on vascular structures were printed. Median print time was 3.83 hours, and material costs were $2.84. The CT scans of the printed models highly matched with the original digital models (root mean square for Hausdorff distance 0.013 ± 0.003 mesh units). Independent reviewers correctly described 80 and 87% of the models (p = 0.334) and reported high quality and accuracy (5 versus 5, p = NS; κ = 0.615). CONCLUSION: Imaging data from rotational angiography can be converted into accurate three-dimensional-printed models of CHD. The cost of printing the models was negligible, but the print time was prohibitive for real-time use. As the speed of three-dimensional printing technology increases, novel future applications may allow for printing patient-specific devices based on rotational angiography datasets.


Assuntos
Cardiopatias Congênitas , Impressão Tridimensional , Angiografia , Cateterismo Cardíaco , Criança , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Modelos Anatômicos , Estudos Retrospectivos
8.
Catheter Cardiovasc Interv ; 95(2): 270-279, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31609082

RESUMO

OBJECTIVE: We describe the technical considerations of transcatheter implantation of the CardioMEMS™ HF System (Abbott, Abbott Park, IL) in adult patients with complex palliated congenital heart disease (CHD) and advanced heart failure (HF). BACKGROUND: Ambulatory pulmonary artery (PA) pressure monitoring with implantable hemodynamic monitors (IHMs) has been shown to reduce HF-related hospital admissions in non-CHD populations. HF is a common late cardiovascular complication in adult CHD necessitating better understanding of IHM application in this population. METHODS: We analyzed adults with complex CHD and advanced HF who were referred for CardioMEMS™ device implantation (2015-2018). Feasibility of device implantation, defined by successful device implantation and calibration, and procedural outcomes were evaluated. RESULTS: CardioMEMS™ was successfully implanted in all 14 adults (35.5 ± 9.2 years old, 72 ± 12 kg) with complex CHD (single ventricle/Fontan, n = 8 [57%]; d-transposition of the great arteries/atrial switch, n = 6 [43%]). The device was delivered via femoral venous access in 13 (93%) patients and implanted in the left PA in 12 (86%). A long sheath was used in 8 (57%) patients, including 5/6 with an atrial switch operation. There was one device migration that did not require retrieval. CONCLUSIONS: Transcatheter implantation of an IHM is feasible in select complex adult CHD patients with advanced HF. Further studies evaluating integration of ambulatory hemodynamics and the impact on clinical care are needed. This technology has the potential to improve medical management of advanced HF in patients with Fontan and atrial switch physiologies and provide new insights into their ambulatory hemodynamics.


Assuntos
Pressão Arterial , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Cardiopatias Congênitas/terapia , Insuficiência Cardíaca/diagnóstico , Cuidados Paliativos , Artéria Pulmonar/fisiopatologia , Tecnologia de Sensoriamento Remoto/instrumentação , Adulto , Feminino , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
9.
Catheter Cardiovasc Interv ; 96(6): 1266-1276, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32433821

RESUMO

OBJECTIVES: Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure. BACKGROUND: The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature. METHODS: This was a single arm, prospective, multicenter, non-randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g. From June 2017 to February 2019, 200 patients were enrolled at nine centers, with 100 patients weighing ≤2 kg. Primary effectiveness endpoint was the rate of PDA closure at 6-month follow-up. Primary safety endpoint was the rate of major complications through 6 months. Secondary endpoint was rate of significant pulmonary or aortic obstruction through 6 months' follow-up. RESULTS: The implant success rate was 95.5% (191/200) overall and 99% in patients ≤2 kg (99/100). The primary effectiveness endpoint was achieved in 99.4% of implanted patients. Four patients experienced a primary safety endpoint event (2 transfusions, 1 hemolysis, and 1 aortic obstruction). There were no branch pulmonary artery obstructions. Five patients, all ≤2 kg, were noted to have worsening of tricuspid regurgitation (TR) after the procedure. None of the TR incidences manifested clinically. The Amplatzer Piccolo Occluder received FDA approval in January 2019 and became the first device approved for PDA closure in patients ≥700 g. CONCLUSIONS: This study supports the safety and effectiveness of the Amplatzer Piccolo Occluder, particularly in patients between 700 g and 2 kg where there is currently a significant unmet need in the United States. ClinicalTrials.gov identifier: NCT03055858.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Lactente Extremamente Prematuro , Recém-Nascido de muito Baixo Peso , Dispositivo para Oclusão Septal , Peso ao Nascer , Cateterismo Cardíaco/efeitos adversos , Circulação Coronária , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Idade Gestacional , Hemodinâmica , Humanos , Recém-Nascido , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
10.
Echocardiography ; 37(11): 1869-1872, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33011997

RESUMO

A fetal echocardiogram noted valvar pulmonary atresia vs critical pulmonary valve stenosis, confluent pulmonary arteries, patent ductus arteriosus, and an apical muscular ventricular septal defect vs coronary sinusoid. Postnatal echocardiogram documented an absent pulmonary valve, coronary artery fistula to the right ventricle, confluent pulmonary arteries, and a patent ductus arteriosus. Catheterization confirmed the postnatal echocardiographic findings except there was no antegrade flow from the right ventricle to the pulmonary arteries. Close evaluation of all imaging modalities revealed the final diagnosis of absent pulmonary valve with a double-chambered right ventricle with no egress from the right ventricle to pulmonary artery.


Assuntos
Cardiopatias Congênitas , Atresia Pulmonar , Valva Pulmonar , Septo Interventricular , Humanos , Atresia Pulmonar/diagnóstico por imagem , Valva Pulmonar/diagnóstico por imagem , Septo Interventricular/diagnóstico por imagem
11.
J Pediatr ; 212: 144-150.e3, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31262530

RESUMO

OBJECTIVES: To describe longer term outcomes for infants <6 kg undergoing percutaneous occlusion of the patent ductus arteriosus (PDA). STUDY DESIGN: This was a retrospective cohort study of infants <6 kg who underwent isolated percutaneous closure of the PDA at a single, tertiary center (2003-2017). Cardiopulmonary outcomes and device-related complications (eg, left pulmonary artery obstruction) were examined for differences across weight thresholds (very low weight, <3 kg; low weight, 3-<6 kg). We assessed composite measures of respiratory status during and beyond the initial hospitalization using linear mixed effects models. RESULTS: In this cohort of lower weight infants, 92 of 106 percutaneous occlusion procedures were successful. Median age and weight at procedure were 3.0 months (range, 0.5-11.1 months) and 3.7 kg (range, 1.4-5.9 kg), respectively. Among infants with pulmonary artery obstruction on initial postprocedural echocardiograms (n = 20 [22%]), obstruction persisted through hospital discharge in 3 infants. No measured variables were associated with device-related complications. Rates of oxygenation failure (28% vs 8%; P < .01) and decreased left ventricular systolic function (29% vs 5%; P < .01) were higher among very low weight than low weight infants. Pulmonary scores decreased (indicating improved respiratory status) following percutaneous PDA closure. CONCLUSIONS: Percutaneous PDA occlusion among lower weight infants is associated with potential longer term improvements in respiratory health. Risks of device-related complications and adverse cardiopulmonary outcomes, particularly among very low weight infants, underscore the need for continued device modification. Before widespread use, clinical trials comparing percutaneous occlusion vs alternative treatments are needed.


Assuntos
Permeabilidade do Canal Arterial/terapia , Oclusão Terapêutica , Estudos de Coortes , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido de Baixo Peso , Recém-Nascido , Masculino , Estudos Retrospectivos , Oclusão Terapêutica/métodos , Fatores de Tempo , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 94(3): 416-421, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31276274

RESUMO

The Gore Viabahn VBX balloon-expandable endoprosthesis (W. L. Gore & Associates, Flagstaff, AZ) is a flexible covered stent that is FDA-approved for the treatment of iliac artery stenosis, including lesions at the aortic bifurcation. In this case series, we report the first use of the VBX covered stent in congenital heart disease, highlighting several of its unique advantages.


Assuntos
Angioplastia com Balão/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cardiopatias Congênitas/cirurgia , Cuidados Paliativos , Doenças Vasculares Periféricas/cirurgia , Stents , Adulto , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Humanos , Recém-Nascido , Masculino , Doenças Vasculares Periféricas/diagnóstico por imagem , Doenças Vasculares Periféricas/fisiopatologia , Desenho de Prótese , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 93(3): 474-480, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30419603

RESUMO

OBJECTIVES: This study describes procedural and 1-year outcomes of the 16 mm Melody PB1016 valve in patients with dysfunctional RVOT conduits. BACKGROUND: The Melody PB1016 is a standard Melody valve produced from a 16 mm bovine jugular vein and is intended for deployment up to 20 mm. METHODS: This is a prospective, non-randomized, multicenter study of the procedural and short-term outcomes of Melody PB1016 TPV replacement within dysfunctional RVOT conduits. Data from eight centers were included in the analysis. RESULTS: During the study period, 39 patients underwent attempted Melody TPVR. Of the 39 patients, 30 underwent successful Melody TPVR. The majority of patients underwent placement of one or more stents prior to TPVR. There was a significant reduction in peak conduit pressure gradient following TPVR (38 mmHg vs. 11 mmHg, P < 0.001). There were three cases of confined conduit tears successfully treated with covered stents or the valve itself. Repeat catheterization was performed in one patient for early re-obstruction that was successfully treated with balloon valvuloplasty. At recent follow-up, there were no cases of more than mild valve regurgitation and the mean pulmonary valve gradient by echocardiogram remained reduced relative to pre-TPVR implant measurements (33.5 mmHg vs. 15.2 mmHg). There were no cases of valve stent fracture or endocarditis reported at the 1-year follow-up. CONCLUSIONS: Our analysis of TPVR with the PB1016 valve in RVOT conduits showed it to be safe and effective and can be performed in a wide range of conduit sizes with preserved valve function. ClinicalTrials.gov Identifier: NCT02347189.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Veias Jugulares/transplante , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Stents , Adolescente , Adulto , Animais , Canadá , Cateterismo Cardíaco/efeitos adversos , Bovinos , Criança , Europa (Continente) , Feminino , Cardiopatias Congênitas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Xenoenxertos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Resultado do Tratamento , Estados Unidos , Adulto Jovem
14.
Catheter Cardiovasc Interv ; 93(4): 645-651, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30511498

RESUMO

OBJECTIVES: To report the results of the Nit-Occlud PDA prospective postapproval study (PAS) along with a comparison to the results of the pivotal and continued access trials. BACKGROUND: The Nit-Occlud PDA (PFM Medical, Cologne, Germany), a nitinol coil patent ductus arteriosus (PDA) occluder, was approved by the Food and Drug Administration in 2013. METHODS: The PAS enrolled a total of 184 subjects greater than 6 months of age, weighing at least 5 kg, with PDAs less than 4 mm by angiography at 11 centers. Patients were followed prospectively at 2 months, 12 months, and 24 months postprocedure. These outcomes were compared to the 357 subjects enrolled in the pivotal and continued access protocols. Efficacy and safety data were reported. RESULTS: Among 184 subjects enrolled for the PAS between 2014 and 2017, 180 (97.8%) had successful device implantation. After 12 months, 98.7% (150/152) had trivial or no residual shunt by echocardiography and two subjects had only small residual shunts. There were three device embolizations that were all retrieved by snare without clinical consequence. Together with the pivotal and continued access study, 97.4% (449/461) had complete echocardiographic closure at 12 months in 541 enrolled subjects. The composite success was 94.4%. There were no mortalities and no serious device-related adverse events. CONCLUSIONS: The Nit-Occlud PDA is a safe and effective device for closure of a small to moderate sized PDA. There were no serious device-related adverse events in a large cohort of three clinical trials.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Adolescente , Ligas , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Aprovação de Equipamentos , Permeabilidade do Canal Arterial/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Lactente , Masculino , Ensaios Clínicos Controlados não Aleatórios como Assunto , Vigilância de Produtos Comercializados , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
15.
Echocardiography ; 36(7): 1434-1436, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31215683

RESUMO

An 8-year-old boy with tetralogy of Fallot, pulmonary atresia, and major aortopulmonary collaterals status post complete repair including a fenestrated ventricular septal defect patch presented to the catheterization laboratory for fenestration closure. During the procedure, the catheterization wire was found to have an unusual intracardiac loop and was unable to be straightened within the heart. Three-dimensional transesophageal echocardiography revealed the wire was looped around a right ventricular papillary muscle. The wire was readjusted, and the fenestration was successfully closed. Three-dimensional imaging was essential in unambiguously defining the catheter course and assisting in fenestration closure.


Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Músculos Papilares/diagnóstico por imagem , Criança , Humanos , Masculino , Músculos Papilares/cirurgia , Atresia Pulmonar/complicações , Tetralogia de Fallot/complicações
16.
Pediatr Cardiol ; 39(6): 1236-1241, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29744656

RESUMO

Recent advances in the field of pediatric interventional cardiology have resulted in therapies for patients in need of augmented pulmonary artery (PA) flow. Catheter-based PA rehabilitation can be performed safely but not without the potential risk of pulmonary hemorrhage. When severe, this bleeding has the ability to contaminate the bronchi and trachea, and possibly occlude the endotracheal tube. This can result in a critical inability to ventilate and oxygenate these patients. Herein, we review our institutional experience with pulmonary hemorrhage associated with these procedures and the feasibility of predicting this outcome. The secondary aim was to discuss our novel anesthetic approach to a select group of these patients, involving the use of bronchial blockers to preemptively prevent contamination of bilateral bronchi and occlusion of the endotracheal tube.


Assuntos
Cateterismo de Swan-Ganz/efeitos adversos , Cardiopatias Congênitas/cirurgia , Intubação Intratraqueal/efeitos adversos , Artéria Pulmonar/lesões , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Criança , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos
17.
Echocardiography ; 34(12): 1967-1968, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28898459

RESUMO

Percutaneous closure of an atrial septal defect in the cardiac catheterization laboratory requires noninvasive imaging to assist in characterization of the atrial septal defect and deployment of the device. Transesophageal echocardiography is the modality most often used in these circumstances. Transesophageal echocardiographic guidelines exist for the assessment and guidance for atrial septal defect closures, but these guidelines do not mention transgastric views. In this case, we demonstrate that transgastric views are helpful in describing the atrial septal defect, especially as it concerns the inferior vena cava rim.


Assuntos
Ecocardiografia Transesofagiana/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Ultrassonografia de Intervenção/métodos , Humanos
18.
Circulation ; 131(22): 1960-70, 2015 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-25944758

RESUMO

BACKGROUND: Studies of transcatheter pulmonary valve (TPV) replacement with the Melody valve have demonstrated good short-term outcomes, but there are no published long-term follow-up data. METHODS AND RESULTS: The US Investigational Device Exemption trial prospectively enrolled 171 pediatric and adult patients (median age, 19 years) with right ventricular outflow tract conduit obstruction or regurgitation. The 148 patients who received and were discharged with a TPV were followed up annually according to a standardized protocol. During a median follow-up of 4.5 years (range, 0.4-7 years), 32 patients underwent right ventricular outflow tract reintervention for obstruction (n=27, with stent fracture in 22), endocarditis (n=3, 2 with stenosis and 1 with pulmonary regurgitation), or right ventricular dysfunction (n=2). Eleven patients had the TPV explanted as an initial or second reintervention. Five-year freedom from reintervention and explantation was 76±4% and 92±3%, respectively. A conduit prestent and lower discharge right ventricular outflow tract gradient were associated with longer freedom from reintervention. In the 113 patients who were alive and reintervention free, the follow-up gradient (median, 4.5 years after implantation) was unchanged from early post-TPV replacement, and all but 1 patient had mild or less pulmonary regurgitation. Almost all patients were in New York Heart Association class I or II. More severely impaired baseline spirometry was associated with a lower likelihood of improvement in exercise function after TPV replacement. CONCLUSIONS: TPV replacement with the Melody valve provided good hemodynamic and clinical outcomes up to 7 years after implantation. Primary valve failure was rare. The main cause of TPV dysfunction was stenosis related to stent fracture, which was uncommon once prestenting became more widely adopted. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870.


Assuntos
Cateterismo Cardíaco/tendências , Implante de Prótese de Valva Cardíaca/tendências , Hemodinâmica , Insuficiência da Valva Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Adulto , Criança , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/epidemiologia , Resultado do Tratamento , Estados Unidos/epidemiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico , Obstrução do Fluxo Ventricular Externo/epidemiologia , Adulto Jovem
19.
Catheter Cardiovasc Interv ; 88(2): 248-52, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27014843

RESUMO

The Fontan anatomy leads to elevated central venous pressure along with chronic venous congestion and low cardiac output; this is felt to be responsible for deterioration of exercise tolerance and functional capacity over time. Real-time hemodynamic evaluation of the Fontan anatomy has not been evaluated until now. Here, we report the technical aspects of the first two adult Fontan patients to undergo placement of an invasive hemodynamic monitor (IHM). We validate IHM readings with invasive pulmonary artery catheter derived hemodynamics in the Fontan and show successful home transmission of pulmonary artery hemodynamic tracings. This technology has the capacity to change current understanding of Fontan hemodynamics and treatment in patients with complex single-ventricle anatomy. © 2016 Wiley Periodicals, Inc.


Assuntos
Pressão Arterial , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Técnica de Fontan , Cardiopatias Congênitas/cirurgia , Artéria Pulmonar/fisiopatologia , Tecnologia de Sensoriamento Remoto , Adulto , Angiografia , Débito Cardíaco , Cateterismo de Swan-Ganz , Desenho de Equipamento , Feminino , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Valor Preditivo dos Testes , Artéria Pulmonar/diagnóstico por imagem , Fatores de Tempo , Transdutores de Pressão , Resultado do Tratamento
20.
Cardiol Young ; 26(5): 948-56, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26521753

RESUMO

BACKGROUND: Transcatheter pulmonary valve implantation is usually performed from a femoral venous - transfemoral - approach, but this may not be the optimal vascular access option in some patients. This study aimed to determine which group of patients might benefit from an internal jugular - transjugular - approach for transcatheter pulmonary valve implantation. METHODS: This multicentre retrospective study included all patients who underwent attempted transcatheter pulmonary valve placement in the right ventricular outflow tract between April 2010 and June 2012 at two large congenital heart centres. Patients were divided into two groups based on venous access site - transfemoral or transjugular. Patient characteristics, procedural outcomes, and complications were compared between groups. RESULTS: Of 81 patients meeting the inclusion criteria (median age 16.4 years), the transjugular approach was used in 14 patients (17%). The transjugular group was younger (median age 11.9 versus 17.3 years), had lower body surface area (mean 1.33 versus 1.61 m2), more often had moderate or greater tricuspid regurgitation (29% versus 7%), and had a higher ratio of right ventricle-to-systemic systolic pressure (mean 82.4 versus 64.7). Patients requiring a transjugular approach after an unsuccessful transfemoral approach had longer fluoroscopic times and procedure duration. CONCLUSIONS: The transjugular approach for transcatheter pulmonary valve implantation is used infrequently but is more often used in younger and smaller patients. Technical limitations from a transfemoral approach may be anticipated if there is moderate or greater tricuspid regurgitation or higher right ventricular pressures. In these patients, a transjugular approach should be considered early.


Assuntos
Cardiopatias Congênitas/complicações , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Veias Jugulares/cirurgia , Valva Pulmonar/anormalidades , Valva Pulmonar/cirurgia , Adolescente , Criança , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/epidemiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA