Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Pacing Clin Electrophysiol ; 47(1): 113-116, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37310105

RESUMO

BACKGROUND: Power-on reset (PoR) is most commonly due to electromagnetic interference. Full PoR results in a switch to an inhibited mode (VVI) pacing and resets pacing outputs to maximal unipolar settings, leading to extracardiac stimulation. METHODS: We present a case of PoR occurrence in the absence of electromagnetic interference, resulting in pectoral stimulation triggered by violation of the atrial rate limit. CONCLUSIONS: It is useful for clinicians to recognizethe occurrence of PoR in the setting of atrial limit violation andthe appropriate management in such circumstances.


Assuntos
Marca-Passo Artificial , Humanos , Marca-Passo Artificial/efeitos adversos , Átrios do Coração , Estimulação Cardíaca Artificial/métodos
2.
J Cardiovasc Electrophysiol ; 31(5): 1213-1217, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32108404

RESUMO

A 25-year-old runner received a single-lead, VDD pacemaker after ablation of AV nodal reentrant tachycardia complicated by intermittent AV block. The rate-adaptive AV delay algorithm (RAAV), which shortens the sensed AV interval (SAV) at faster atrial rates, was programmed to provide a physiologic SAV with exercise. She developed repetitive, atypical, long-RP pacemaker-mediated tachycardia (PMT) because the RAAV shortened the antegrade SAV and retrograde conduction occurred over the slow AV nodal pathway. PMT was refractory to usual programming solutions. Using high-density electroanatomic mapping, we were able to ablate the retrograde limb of PMT without further damaging AV conduction.


Assuntos
Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Ablação por Cateter/efeitos adversos , Sistema de Condução Cardíaco/cirurgia , Marca-Passo Artificial , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Adulto , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Reoperação , Corrida , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 16(8): 811-7, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16101620

RESUMO

BACKGROUND: Ventricular desynchronization caused by right ventricular pacing may impair ventricular function and increase risk of heart failure (CHF), atrial fibrillation (AF), and death. Conventional DDD/R mode often results in high cumulative percentage ventricular pacing (Cum%VP). We hypothesized that a new managed ventricular pacing mode (MVP) would safely provide AAI/R pacing with ventricular monitoring and DDD/R during AV block (AVB) and reduce Cum%VP compared to DDD/R. METHODS: MVP RAMware was downloaded in 181 patients with Marquis DR ICDs. Patients were initially randomized to either MVP or DDD/R for 1 month, then crossed over to the opposite mode for 1 month. ICD diagnostics were analyzed for cumulative percentage atrial pacing (Cum%AP), Cum%VP, and duration of DDD/R pacing for spontaneous AVB. RESULTS: Baseline characteristics included age 66 +/- 12 years, EF 36 +/- 14%, and NYHA Class II-III 36%. Baseline PR interval was 190 +/- 53 msec and programmed AV intervals (DDD/R) were 216 +/- 50 (paced)/189 +/- 53 (sensed) msec. Mean Cum%VP was significantly lower in MVP versus DDD/R (4.1 +/- 16.3 vs 73.8 +/- 32.5, P < 0.0001). The median absolute and relative reductions in Cum%VP during MVP were 85.0 and 99.9, respectively. Mean Cum%AP was not different between MVP versus DDD/R (48.7 +/- 38.5 vs 47.3 +/- 38.4, P = 0.83). During MVP overall time spent in AAI/R was 89.6% (intrinsic conduction), DDD/R 6.7% (intermittent AVB), and DDI/R 3.7% (AF). No adverse events were attributed to MVP. CONCLUSIONS: MVP safely achieves functional atrial pacing by limiting ventricular pacing to periods of intermittent AVB and AF in ICD patients, significantly reducing Cum%VP compared to DDD/R. MVP is a universal pacing mode that adapts to AVB and AF, providing both atrial pacing and ventricular pacing support when needed.


Assuntos
Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Adulto , Idoso , Nó Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA