Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 26(6): 1064-1072, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28131679

RESUMO

BACKGROUND: The incidence of asymptomatic rotator cuff tears has been reported to range from 15% to 39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. This study assessed the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. METHODS: A clinical ultrasound examination was performed in 46 asymptomatic volunteers (age: 60.3 ± 7.5 years) with normal shoulder function to document the condition of their rotator cuff. The ultrasound imaging identified the participants as healthy (n = 14) or pathologic (n = 32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex (Biodex Medical Systems, Inc., Shirley, NY, USA), and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale pain scores. RESULTS: Compared with healthy volunteers, those with rotator cuff pathology had significantly less abduction (P = .050) and elevation (P = .041) strength, their humerus was positioned more inferiorly on the glenoid (P = .018), and the glenohumeral contact path length was longer (P = .007). No significant differences were detected in the Western Ontario Rotator Cuff Index, visual analog scale, range of motion, or acromiohumeral distance. CONCLUSIONS: The differences observed between the healthy volunteers and those with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology.


Assuntos
Doenças Assintomáticas , Força Muscular/fisiologia , Amplitude de Movimento Articular/fisiologia , Lesões do Manguito Rotador/diagnóstico , Manguito Rotador/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Imageamento Tridimensional , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Manguito Rotador/fisiopatologia , Lesões do Manguito Rotador/epidemiologia , Lesões do Manguito Rotador/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ultrassonografia , Estados Unidos/epidemiologia
2.
Surg Radiol Anat ; 39(10): 1069-1078, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28343254

RESUMO

PURPOSE: Neural foraminal dimensions are considered important in nerve root compression and development of cervical radiculopathy, but baseline data regarding their range during normal motion are not available. An in vivo study of cervical foraminal motion was conducted to characterize normal 3D dynamic foraminal dimensions during physiological neck motion and compare between different tasks and intervertebral segments. METHODS: Biplane X-ray imaging and computed tomography-based markerless tracking were used to measure foraminal height (FH) and width (FW) from five asymptomatic subjects during neck axial rotation and extension. FH and FW were quantified as the minimum (SI.Min and AP.Min), range (SI.Range and AP.Range), and median (SI.Med and AP.Med) of superoinferior (SI) and anteroposterior (AP) dimensions for each trial and as the coefficient of variation of these variables from three trials (SI.Med.CV and AP.Med.CV, SI.Range.CV and AP.Range.CV) at C3-4 through C6-7 levels for each subject. Differences were analyzed using mixed model ANOVA. RESULTS: AP.Range and AP.Med.CV were greater (P < 0.0001) while AP.Min and AP.Range.CV were smaller (P < 0.0006 and P < 0.0005) during neck extension than rotation. SI.Range and SI.Med.CV were greater for extension than rotation at C5-6 (P < 0.002 and P < 0.03), whereas SI.Med.CV was greater for rotation than extension at C3-4 (P < 0.03). AP.Range (P < 0.02), AP.Med.CV (P < 0.05), SI.Range (P < 0.0004), and SI.Med.CV (P < 0.02) were different between cervical levels, the latter two being during extension only. CONCLUSIONS: Patterns of FH and FW during normal motion are different between tasks and cervical levels. These findings are expected to provide a basis for future studies of spinal degeneration and surgical efficacy.


Assuntos
Vértebras Cervicais/fisiologia , Amplitude de Movimento Articular/fisiologia , Adulto , Vértebras Cervicais/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Masculino , Movimento/fisiologia , Interpretação de Imagem Radiográfica Assistida por Computador , Rotação , Tomografia Computadorizada por Raios X , Articulação Zigapofisária/diagnóstico por imagem , Articulação Zigapofisária/fisiologia
3.
J Biomech Eng ; 138(1)2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26592901

RESUMO

Measures of scapulothoracic motion are dependent on accurate imaging of the scapula and thorax. Advanced radiographic techniques can provide accurate measures of scapular motion, but the limited 3D imaging volume of these techniques often precludes measurement of thorax motion. To overcome this, a thorax coordinate system was defined based on the position of rib pairs and then compared to a conventional sternum/spine-based thorax coordinate system. Alignment of the rib-based coordinate system was dependent on the rib pairs used, with the rib3:rib4 pairing aligned to within 4.4 ± 2.1 deg of the conventional thorax coordinate system.


Assuntos
Imageamento Tridimensional/métodos , Movimento , Radiografia Torácica/métodos , Tórax/fisiologia , Humanos , Pessoa de Meia-Idade , Escápula/diagnóstico por imagem , Escápula/fisiologia , Tomografia Computadorizada por Raios X
4.
Arthroscopy ; 31(9): 1708-15, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26354194

RESUMO

PURPOSE: To use ultrasound imaging to document changes over time (i.e., preseason v postseason) in the pitching elbow of high school baseball pitchers. METHODS: Twenty-two high school pitchers were prospectively followed. Pitchers were evaluated after a 2-month period of relative arm rest via preseason physical exams, dynamic ultrasound imaging of their throwing elbow, and the Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) assessment. Players were reevaluated within 1 week of their last game. Dynamic ultrasound images were then randomized, blinded to testing time point, and evaluated by 2 fellowship-trained musculoskeletal radiologists. RESULTS: Average pitcher age was 16.9 years. Average pitches thrown was 456.5, maximum velocity 77.7 mph, games pitched 7.3, and days off between starts 6.6. From preseason to postseason, there were significant increases in ulnar collateral ligament (UCL) thickness (P = .02), ulnar nerve cross-sectional area (P = .001), UCL substance heterogeneity (P = .001), and QuickDASH scores (P = .03). In addition, there was a nonsignificant increase in loaded ulnohumeral joint space (P = .10). No pitchers had loose bodies on preseason exam, while 3 demonstrated loose bodies postseason. The increase in UCL thickness was significantly associated with the number of bullpen sessions per week (P = .01). The increase in ulnar nerve cross-sectional area was significantly associated with the number of pitches (P = .04), innings pitched (P = .01), and games pitched (P = .04). CONCLUSIONS: The stresses placed on the elbow during only one season of pitching create adaptive changes to multiple structures about the elbow including UCL heterogeneity and thickening, increased ulnohumeral joint space laxity, and enlarged ulnar nerve cross-sectional area. LEVEL OF EVIDENCE: Level II prospective observational study.


Assuntos
Beisebol/fisiologia , Articulação do Cotovelo/diagnóstico por imagem , Cotovelo/diagnóstico por imagem , Adolescente , Anatomia Transversal , Ligamentos Colaterais/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Distribuição Aleatória , Nervo Ulnar/diagnóstico por imagem , Ultrassonografia
5.
J Shoulder Elbow Surg ; 24(7): 1014-20, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25958216

RESUMO

BACKGROUND: Traumatic glenohumeral joint (GHJ) dislocations are common, resulting in significant shoulder disability and pain. Previous research indicates that bony morphology is associated with an increased risk of injury in other joints (eg, the knee), but the extent to which bony morphology is associated with traumatic GHJ dislocation is unknown. This study assessed GHJ morphology in patients with anterior GHJ instability and in a control population of healthy volunteers. METHODS: Bilateral computed tomography scans were used to measure GHJ morphology in both shoulders of 11 patients with instability and 11 control subjects. Specific outcome measures included the glenoid radius of curvature (ROC) in the anterior/posterior (A/P) and superior/inferior (S/I) directions, humeral head ROC, A/P and S/I conformity index, and A/P and S/I stability angle. RESULTS: Compared with the control subjects, the glenoid of the instability the injured shoulder in patients with instability was flatter (ie, higher ROC) in the A/P (P = .001) and S/I (P = .01) directions and this finding was also true for uninjured, contralateral shoulder (A/P: P = .01, S/I: P = .03). No differences in GHJ morphology were detected between the instability patients' injured and contralateral shoulders (P > .07). Similarly, no differences in GHJ morphology were detected between the control subjects' dominant and nondominant shoulders (P > .51). CONCLUSIONS: There are significant differences in GHJ morphology between healthy control subjects and both shoulders (injured and uninjured, contralateral) of patients diagnosed with anterior instability after GHJ dislocation. These findings are important clinically because they suggest that glenoid morphology may influence the risk of GHJ dislocation.


Assuntos
Instabilidade Articular/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Instabilidade Articular/fisiopatologia , Masculino , Estudos Retrospectivos , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/fisiopatologia , Lesões do Ombro , Articulação do Ombro/fisiologia , Tomografia Computadorizada por Raios X , Adulto Jovem
6.
Knee Surg Sports Traumatol Arthrosc ; 22(11): 2715-20, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23846505

RESUMO

PURPOSE: Osteoarthritis (OA) of the knee is commonly treated through the use of medial compartment unloading braces which have been shown to improve clinical symptoms. The objective of this study was to assess the effects of a medial compartment unloading brace on biomechanical measurements and clinical outcomes. We hypothesized that brace usage would lead to increased medial joint space and improved clinical outcomes. METHODS: Ten patients with medial compartment OA were prescribed a medial compartment unloading brace and underwent dynamic biplane radiograph imaging while walking with and without the brace. The Western Ontario and McMaster University Osteoarthritis (WOMAC) Index was used to assess pain before brace wear and at the time of testing. The 3D position and orientation of the femur and tibia were determined using a model-based tracking technique. RESULTS: Patients saw an average improvement of 33 % in their WOMAC scores (p = 0.01). This study failed to detect any statistically significant changes in the functional joint space, knee kinematics, or contact centre location between the braced and unbraced condition (n.s.). CONCLUSION: The data from this study, using a highly accurate (±0.6 mm and ±0.6°) 3D radiograph analysis of dynamic tibiofemoral motion, suggest that the brace is ineffective at increasing joint space. However, it was shown to be effective in improving clinical outcome and therefore should continue to be prescribed to patients even though the mechanism of its effectiveness remains unknown. LEVEL OF EVIDENCE: IV.


Assuntos
Braquetes , Marcha/fisiologia , Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/fisiopatologia , Idoso , Fenômenos Biomecânicos , Simulação por Computador , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/terapia , Radiografia , Caminhada/fisiologia
7.
J Shoulder Elbow Surg ; 23(11): 1591-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25183663

RESUMO

BACKGROUND: Medial ulnar collateral ligament (MUCL) reconstruction is commonly performed on Major League Baseball (MLB) pitchers. Previous studies have reported that most pitchers return to presurgical statistical performance levels after MUCL reconstruction. METHODS: Pitching performance data--specifically, earned run average (ERA), walks and hits per inning pitched (WHIP), winning percentage, and innings pitched--were acquired for 168 MLB pitchers who had undergone MUCL reconstruction. These data were averaged over the 3 years before surgery and the 3 years after surgery and also acquired from 178 age-matched, uninjured MLB pitchers. RESULTS: Of the pitchers who had MUCL reconstruction surgery, 87% returned to MLB pitching. However, compared with presurgical data, pitching performance declined in terms of ERA (P = .001), WHIP (P = .011), and innings pitched (P = .026). Pitching performance also declined in the season before the surgery compared with previous years (ERA, P = .014; WHIP, P = .036; innings pitched, P < .001; winning percentage, P = .004). Compared with age-matched control pitchers, the MUCL reconstruction pitchers had significantly more major league experience at the same age (P < .001). CONCLUSION: MUCL reconstruction allows most players to return to pitching at the major league level. However, after MUCL reconstruction, there is a statistically significant decline in pitching performance. There appears to be a statistically significant decline in pitching performance the year before reconstructive surgery, and this decline is also a risk factor for requiring surgery. In addition, there is an increased risk of MUCL reconstruction for pitchers who enter the major leagues at a younger age.


Assuntos
Beisebol/lesões , Ligamentos Colaterais/cirurgia , Articulação do Cotovelo/cirurgia , Procedimentos de Cirurgia Plástica/reabilitação , Adolescente , Adulto , Beisebol/fisiologia , Ligamentos Colaterais/lesões , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição Aleatória , Estudos Retrospectivos , Fatores de Risco , Método Simples-Cego , Adulto Jovem , Lesões no Cotovelo
8.
J Appl Biomech ; 30(3): 461-70, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24584728

RESUMO

Accurate measurements of in-vivo hip kinematics may elucidate the mechanisms responsible for impaired function and chondrolabral damage in hips with femoroacetabular impingement (FAI). The objectives of this study were to quantify the accuracy and demonstrate the feasibility of using dual fluoroscopy to measure in-vivo hip kinematics during clinical exams used in the assessment of FAI. Steel beads were implanted into the pelvis and femur of two cadavers. Specimens were imaged under dual fluoroscopy during the impingement exam, FABER test, and rotational profile. Bead locations measured with model-based tracking were compared with those measured using dynamic radiostereometric analysis. Error was quantified by bias and precision, defined as the average and standard deviation of the differences between tracking methods, respectively. A normal male volunteer was also imaged during clinical exams. Bias and precision along a single axis did not exceed 0.17 and 0.21 mm, respectively. Comparing kinematics, positional error was less than 0.48 mm and rotational error was less than 0.58°. For the volunteer, kinematics were reported as joint angles and bone-bone distance. These results demonstrate that dual fluoroscopy and model-based tracking can accurately measure hip kinematics in living subjects during clinical exams of the hip.


Assuntos
Articulação do Quadril/fisiologia , Imageamento Tridimensional/instrumentação , Modelos Biológicos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Amplitude de Movimento Articular/fisiologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Cadáver , Simulação por Computador , Articulação do Quadril/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
9.
J Orthop Res ; 42(3): 578-587, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37814893

RESUMO

The purpose of this study was to develop a multivariable model to determine the extent to which a combination of etiological factors is associated with supraspinatus tendon tears. Fifty-four asymptomatic individuals (55 ± 4 years) underwent testing of their dominant shoulder. Diagnostic ultrasound was used to assess for a supraspinatus tendon tear. The etiological factors investigated included demographics (age and sex), tendon impingement during shoulder motion (via biplane videoradiography), glenohumeral morphology (via computed tomography imaging), family history of a tear (via self-report), occupational shoulder exposure (via shoulder job exposure matrix), and athletic exposure (via self-report). Univariate relationships between etiological predictors and supraspinatus tears were assessed using logistic regression and odds ratios (ORs), while multivariable relationships were assessed using classification and regression tree analysis. Thirteen participants (24.1%) had evidence of a supraspinatus tear. Individuals with a tear had a higher critical shoulder angle (OR 1.2, p = 0.028) and acromial index (OR 1.2, p = 0.016) than individuals without a tear. The multivariable model suggested that a tear in this cohort can be explained with acceptable accuracy (AUROC = 0.731) by the interaction between acromial index and shoulder occupational exposure: a tear is more likely in individuals with a high acromial index (p < 0.001), and in individuals with a low acromial index and high occupational exposure (p < 0.001). The combination of an individual's glenohumeral morphology (acromial index) and occupational shoulder exposure may be important in the development of supraspinatus tears.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/etiologia , Ombro , Ruptura
10.
J Biomech ; 168: 112110, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38677025

RESUMO

Rotator cuff (RC) tears are a common source of pain and decreased shoulder strength. Muscle length is known to affect muscle strength, and therefore evaluating changes in supraspinatus muscle length associated with RC pathology, surgical repair, and post-operative recovery may provide insights into functional deficits. Our objective was to develop a reliable MRI-based approach for assessing supraspinatus muscle length. Using a new semi-automated approach for identifying 3D location of the muscle-tendon junction (MTJ), supraspinatus muscle length was calculated as the sum of MTJ distance (distance between 3D MTJ position and glenoid plane) and supraspinatus fossa length (distance between root of the scapular spine and glenoid plane). Inter- and intra-operator reliability of this technique were assessed with intraclass correlation coefficient (ICC) and found to be excellent (ICCs > 0.96). Muscle lengths of 6 patients were determined before RC repair surgery and at 3- and 12-months post-surgery. Changes in normalized muscle length (muscle length as a percentage of pre-surgical muscle length) at 3 months post-surgery varied considerably across patients (16.1 % increase to 7.0 % decrease) but decreased in all patients from 3- to 12-months post-surgery (0.3 % to 17.2 %). This study developed a novel and reliable approach for quantifying supraspinatus muscle length and provided preliminary demonstration of its utility by assessing muscle length changes associated with RC pathology and surgical repair. Future studies can use this technique to evaluate changes over time in supraspinatus muscle length in response to clinical intervention, and associations between muscle length and shoulder function.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Lesões do Manguito Rotador , Manguito Rotador , Humanos , Imageamento por Ressonância Magnética/métodos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Manguito Rotador/fisiologia , Masculino , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/fisiopatologia , Pessoa de Meia-Idade , Feminino , Imageamento Tridimensional/métodos , Idoso , Adulto , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Reprodutibilidade dos Testes
11.
J Orthop Res ; 41(4): 718-726, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35880416

RESUMO

Internal impingement-or entrapment of the undersurface of the rotator cuff tendon against the glenoid during overhead activities-is believed to contribute to articular-sided tears. However, little is known about internal impingement outside athletic populations. Therefore, the objectives of this study were to (1) describe glenoid-to-footprint distances and proximity centers during dynamic, in vivo motion in asymptomatic individuals, and (2) determine the extent to which these measures differed between individuals with and without a rotator cuff tear. Shoulder kinematics were assessed in 37 asymptomatic individuals during scapular plane abduction using a high-speed biplane radiographic system. Glenoid-to-footprint distances and proximity center locations were calculated by combining the kinematics with computerized tomography-derived bone models. Glenoid-to-footprint contact was presumed to occur when the minimum distance was less than the estimated labral thickness. The condition of the supraspinatus tendon (intact, torn) was assessed using ultrasound. Minimum distances and proximity centers were compared over humerothoracic elevation angles (90°, 110°, 130°, 150°) and between supraspinatus pathology groups using two-factor mixed model analysis of variances. Glenoid-to-footprint minimum distances decreased consistently across elevation angles (p < 0.01) without a significant difference between groups. Contact was estimated to occur in all participants. Proximity centers were generally located on the anterior half of the rotator cuff footprint and on the posterosuperior glenoid. Statement of Clinical Significance: Internal impingement during overhead motions may be a prevalent mechanism of rotator cuff pathology as contact appears to be common and involves the region of the rotator cuff footprint where degenerative rotator cuff tears are thought to originate.


Assuntos
Lesões do Manguito Rotador , Síndrome de Colisão do Ombro , Articulação do Ombro , Humanos , Manguito Rotador , Escápula , Rotação , Fenômenos Biomecânicos , Amplitude de Movimento Articular
12.
J Biomech Eng ; 134(12): 124502, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23363209

RESUMO

BACKGROUND: The objectives of this study were to characterize the translational and rotational accuracy of a model-based tracking technique for quantifying elbow kinematics and to demonstrate its in vivo application. METHOD OF APPROACH: The accuracy of a model-based tracking technique for quantifying elbow kinematics was determined in an in vitro experiment. Biplane X-ray images of a cadaveric elbow were acquired as it was manually moved through flexion-extension. The 3D position and orientation of each bone was determined using model-based tracking. For comparison, the position and orientation of each bone was also determined by tracking the position of implanted beads with dynamic radiostereometric analysis. Translations and rotations were calculated for both the ulnohumeral and radiohumeral joints, and compared between measurement techniques. To demonstrate the in vivo application of this technique, biplane X-ray images were acquired as a human subject extended their elbow from full flexion to full extension. RESULTS: The in vitro validation demonstrated that the model-based tracking technique is capable of accurately measuring elbow motion, with reported errors averaging less than ±1.0 mm and ±1.0 deg. For the in vivo application, the carrying angle changed from an 8.3 ± 0.5 deg varus position in full flexion to an 8.4 ± 0.5 deg valgus position in full extension. CONCLUSIONS: Model-based tracking is an accurate technique for measuring in vivo, 3D, dynamic elbow motion. It is anticipated that this experimental approach will enhance our understanding of elbow motion under normal and pathologic conditions.


Assuntos
Cotovelo/fisiologia , Fenômenos Mecânicos , Fenômenos Biomecânicos , Humanos , Movimento , Rotação
13.
J Shoulder Elbow Surg ; 21(2): 149-57, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22244057

RESUMO

Chronic tendon pathologies (eg, rotator cuff tears, Achilles tendon ruptures) are common, painful, debilitating, and a significant source of medical expense. Treatment strategies for managing tendon pathologies vary widely in invasiveness and cost, with little scientific basis on which to base treatment selection. Conventional techniques for assessing the outcomes of physical therapy or surgical repair typically rely on patient-based assessments of pain and function, physical measures (eg, strength, range of motion, or stability), and qualitative assessments using magnetic resonance imaging or ultrasound. Unfortunately, these conventional techniques provide only an indirect assessment of tendon function. The inability to make a direct quantitative assessment of the tendon's mechanical capabilities may help to explain the relatively high rate of failed tendon repairs and has led to an interest in the development of tools for directly assessing in vivo tendon function. The purpose of this article is to review methods for assessing tendon function (ie, mechanical properties and capabilities) during in vivo activities. This review will describe the general principles behind the experimental techniques and provide examples of previous applications of these techniques. In addition, this review will characterize the advantages and limitations of each technique, along with its potential clinical utility. Future efforts should focus on developing broadly translatable technologies for quantitatively assessing in vivo tendon function. The ability to accurately characterize the in vivo mechanical properties of tendons would improve patient care by allowing for the systematic development and assessment of new techniques for treating tendon pathologies.


Assuntos
Estresse Mecânico , Traumatismos dos Tendões/diagnóstico , Tendões/fisiopatologia , Tendão do Calcâneo/lesões , Tendão do Calcâneo/cirurgia , Animais , Fenômenos Biomecânicos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Ligamento Patelar/diagnóstico por imagem , Ligamento Patelar/fisiologia , Coelhos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador , Traumatismos dos Tendões/cirurgia , Resistência à Tração , Transdutores/estatística & dados numéricos , Ultrassonografia Doppler
14.
J Biomech ; 145: 111385, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36403529

RESUMO

Several scapular anatomical coordinate systems have been reported in the literature to describe shoulder kinematics. Unfortunately, the use of different conventions hinders comparison across studies. Further, inconsistencies between a coordinate system and the scapula's 3D axis of motion means that scapular motion will be incorrectly attributed to axes about which it did not rotate. The objectives of this study were to: 1) determine the extent to which the axes of four common scapular coordinate system conventions correspond to the 3D axis of scapular motion (i.e., instantaneous helical axis, IHA), and 2) report the prevalence of scapulothoracic gimbal lock for each convention. Shoulder kinematics were tracked during scapular plane abduction in 45 participants using biplane videoradiography. Scapulothoracic kinematics were described using the original convention proposed by van der Helm, the convention recommended by the International Society of Biomechanics (ISB), a glenoid-based coordinate system, and a glenoid-oriented coordinate system. The 3D angle was calculated between the IHA and each axis of the four conventions (IHA-axis angular deviations). A repeated measures ANOVA was used to compare IHA-axis angular deviations between conventions. The glenoid-oriented and ISB conventions resulted in the smallest and largest IHA-axis angular deviations, respectively (21.7°±3.6° vs. 30.5°±5.2°, p < 0.01). Gimbal lock was approached in 17.8% of participants when using the original convention, 2.2% when using the ISB convention, and 0% when using the glenoid-based or -oriented conventions. These findings suggest the glenoid-oriented coordinate system may be worthy of further consideration when investigating shoulder kinematics during scapular plane abduction.

15.
J Orthop Res ; 40(4): 917-924, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34191325

RESUMO

Repair tissue healing after rotator cuff repair remains a significant clinical problem, and excessive shoulder activity after surgical repair is believed to contribute to re-tears. In contrast, small animal studies have demonstrated that complete removal of activity impairs tendon healing and have advocated for an "appropriate" level of activity, but in humans the appropriate amount of shoulder activity to enhance healing is not known. As an initial step toward understanding the relationship between postoperative shoulder activity and repair tissue healing, the objectives of this study were to assess the precision, accuracy, and feasibility of a wrist-worn triaxial accelerometer for measuring shoulder activity. Following assessments of precision (±0.002 g) and accuracy (±0.006 g), feasibility was assessed by measuring 1 week of shoulder activity in 14 rotator cuff repair patients and 8 control subjects. Shoulder activity was reported in terms of volume (mean acceleration, activity count, mean activity index, active time) and intensity (intensity gradient). Patients had significantly less volume (p ≤ .03) and intensity (p = .01) than controls. Time post-surgery was significantly associated with the volume (p ≤ .05 for mean acceleration, activity count, and mean activity index) and intensity (p = .03) of shoulder activity, but not active time (p = .08). These findings indicate this approach has the accuracy and precision necessary to continuously monitor shoulder activity with a wrist-worn sensor. The preliminary data demonstrate the ability to discriminate between healthy control subjects and patients recovering from rotator cuff repair and provide support for using a wearable sensor to monitor changes over time in shoulder activity.


Assuntos
Lesões do Manguito Rotador , Ombro , Animais , Artroscopia/métodos , Humanos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Ombro/cirurgia , Resultado do Tratamento
16.
JSES Int ; 6(1): 62-69, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35141678

RESUMO

BACKGROUND: Rotator cuff repair provides pain relief for many patients; however, retears are relatively common and affect approximately 20%-70% of patients after repair. Although magnetic resonance imaging (MRI) offers the ability to assess tissue characteristics such as tear size, retraction, and fatty infiltration, it provides little insight into the quality of the musculotendinous tissues the surgeon will encounter during surgery. However, shear wave elastography (SWE) could provide an indirect assessment of quality (ie, stiffness) by measuring the speed of shear waves propagating through tissue. The objective of this study was to determine the extent to which estimated shear modulus predicts repair integrity and functional outcomes 1 year after rotator cuff repair. METHODS: Thirty-three individuals scheduled to undergo arthroscopic rotator cuff repair were enrolled in this study. Before surgery, shear modulus of the supraspinatus tendon and muscle was estimated using ultrasound SWE. MRIs were obtained before and 1 year after surgery to assess tear characteristics and repair integrity, respectively. Shoulder strength, range of motion, and patient-reported pain and function were assessed before and after surgery. Functional outcomes were compared between groups and across time using a two-factor mixed model analysis of variance. Stepwise regression with model comparison was used to investigate the extent to which MRI and shear modulus predicted repair integrity and function at 1 year after surgery. RESULTS: At 1 year after surgery, 56.5% of patients had an intact repair. No significant differences were found in any demographic variable, presurgical tear characteristic, or shear modulus between patients with an intact repair and those with a recurrent tear. Compared with presurgical measures, patients in both groups demonstrated significant improvements at 1 year after surgery in pain (P < .01), self-reported function (P < .01), range of motion (P < .01), and shoulder strength (P < .01). In addition, neither presurgical MRI variables (P > .16) nor shear modulus (P > .52) was significantly different between groups at 1 year after surgery. Finally, presurgical shear modulus generally did not improve the prediction of functional outcomes above and beyond that provided by MRI variables alone (P > .22). CONCLUSION: Although SWE remains a promising modality for many clinical applications, this study found that SWE-estimated shear modulus did not predict repair integrity or functional outcomes at 1 year after surgery, nor did it add to the prediction of outcomes above and beyond that provided by traditional presurgical MRI measures of tear characteristics. Therefore, it appears that further research is needed to fully understand the clinical utility of SWE for musculoskeletal tissue and its potential use for predicting outcomes after surgical rotator cuff repair.

17.
J Orthop Res ; 40(6): 1270-1280, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34436796

RESUMO

Glenoid component loosening remains a common complication following anatomic total shoulder arthroplasty (TSA); however, plain radiographs are unable to accurately detect early implant migration. The purpose of this study was to validate the accuracy of a method of postoperative, three-dimensional (3D) computed tomography (CT) imaging with metal artifact reduction (MAR) to detect glenoid component migration following anatomic TSA. Tantalum bead markers were inserted into polyethylene glenoid components for implant detection on 3D CT. In-vitro validation was performed using a glenoid component placed into a scapula sawbone and incrementally translated and rotated, with MAR 3D CT acquired at each test position. Accuracy was evaluated by root mean square error (RMSE). In-vivo validation was performed on six patients who underwent anatomic TSA, with two postoperative CT scans acquired in each patient and marker-based radiostereometric analysis (RSA) performed on the same days. Glenoid component migration was calculated relative to a scapular coordinate system for both MAR 3D CT and RSA. Accuracy was evaluated by RMSE and paired Student's t-tests. The largest RMSE on in-vitro testing was 0.24 mm in translation and 0.11° in rotation, and on in-vivo testing was 0.47 mm in translation and 1.04° in rotation. There were no significant differences between MAR 3D CT and RSA measurement methods. MAR 3D CT imaging is capable of quantifying glenoid component migration with a high level of accuracy. MAR 3D CT imaging is advantageous over RSA because it is readily available clinically and can also be used to evaluate the implant-bone interface.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Articulação do Ombro , Prótese de Ombro , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Cavidade Glenoide/cirurgia , Humanos , Imageamento Tridimensional , Escápula/diagnóstico por imagem , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Tomografia Computadorizada por Raios X/métodos
18.
Clin Biomech (Bristol, Avon) ; 99: 105756, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36063742

RESUMO

BACKGROUND: Arthroplasty with artificial disc replacement for surgical treatment of cervical spine degeneration was introduced with the notion that motion-preserving approaches would prevent development of adjacent segment disease. Though clinical outcomes favor arthroplasty over the commonly used anterior cervical discectomy with fusion approach, clinical studies confirming the biomechanical basis of these results are lacking. The aim of this study was to compare intervertebral kinematics between arthroplasty and fusion patients 6.5 years post-surgery during physiological motion of the neck. METHODS: Using a biplane dynamic X-ray system, computed tomography imaging and model based tracking algorithms, three dimensional intervertebral kinematics were measured during neck axial rotation and extension in 14 patients treated for cervical radiculopathy with fusion (n = 8) or arthroplasty (n = 6). The measurements were performed at 2-year (baseline) and 6.5 year post-surgical time points, with the main interest being in the interaction between surgery types and time points. 3 translations and 3 rotations were investigated for the index (C5C6), and upper- (C4C5) and lower adjacent levels (C6C7). FINDINGS: Surgery-time interaction was significant for axial rotation (P < 0.04) and flexion-extension rotation (P < 0.005) in C4C5 during neck axial rotation, left-right translation (P < 0.04) in C5C6 and anterior-posterior translation in C6C7 (P < 0.04) during neck extension. In contrast with the expectations, axial rotation and flexion-extension decreased in C4C5 during neck rotation and anterior-posterior translation decreased in C6C7 during neck extension for fusion. INTERPRETATION: The findings do not support the notion that adjacent segment motion increases after fusion.


Assuntos
Degeneração do Disco Intervertebral , Disco Intervertebral , Fusão Vertebral , Substituição Total de Disco , Fenômenos Biomecânicos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/fisiologia , Vértebras Cervicais/cirurgia , Discotomia/métodos , Humanos , Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/cirurgia , Degeneração do Disco Intervertebral/cirurgia , Amplitude de Movimento Articular/fisiologia , Fusão Vertebral/métodos , Substituição Total de Disco/métodos , Resultado do Tratamento
19.
Orthop J Sports Med ; 10(3): 23259671221084294, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35387360

RESUMO

Background: Rotator cuff repair is a common orthopaedic procedure that provides pain relief for many patients, but unfortunately, an estimated 20% to 70% of repair procedures will fail. Previous research has shown that elongation (ie, retraction) of a repaired tendon is common even in patients with a repair construct that appears intact on magnetic resonance imaging. However, it is unknown how this repair tissue functions under dynamic conditions. Purpose: To quantify static retraction and maximum dynamic elongation of repair tissue after rotator cuff repair. Study Design: Case series; Level of evidence, 4. Methods: Data from 9 patients were analyzed for this study. During surgery, a 3.1-mm tantalum bead was sutured to the supraspinatus tendon, medial to the repair site. Glenohumeral kinematics were assessed at 1 week (static) and 3 months (static and during scapular-plane abduction) after surgery using a biplanar videoradiographic system. The 3-dimensional position of the bead was calculated relative to the tendon's insertion on the humerus (ie, bead-to-insertion distance). Static retraction was calculated as the change in the bead-to-insertion distance under static conditions between 1 week and 3 months after surgery, and maximum dynamic elongation was calculated as the maximal positive change in the bead-to-insertion distance during dynamic motion relative to the start of motion. The magnitudes of static retraction and maximum dynamic elongation were assessed with 1-sample t tests. Results: At 3 months after surgery, static retraction occurred in all patients by a mean of 10.0 ± 9.1 mm (P = .01 compared with no elongation). During scapular-plane abduction, maximum dynamic elongation averaged 1.4 ± 1.0 mm (P < .01 compared with no elongation). Descriptively, dynamic elongation consistently took 1 of 2 forms: an initial increase in the bead-to-insertion distance (mean, 2.0 ± 0.6 mm) before decreasing until the end of motion or an immediate and substantial decrease in the bead-to-insertion distance at the onset of motion. Conclusion: Repair tissue elongation (static retraction and maximum dynamic elongation) appeared to be a common and significant finding at 3 months after arthroscopic rotator cuff repair. Dynamic elongation of repair tissue during scapular-plane abduction exhibited 1 of 2 distinct patterns, which may suggest different patterns of supraspinatus mechanical and neuromuscular function.

20.
J Vis Exp ; (169)2021 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-33779606

RESUMO

The shoulder is one of the human body's most complex joint systems, with motion occurring through the coordinated actions of four individual joints, multiple ligaments, and approximately 20 muscles. Unfortunately, shoulder pathologies (e.g., rotator cuff tears, joint dislocations, arthritis) are common, resulting in substantial pain, disability, and decreased quality of life. The specific etiology for many of these pathologic conditions is not fully understood, but it is generally accepted that shoulder pathology is often associated with altered joint motion. Unfortunately, measuring shoulder motion with the necessary level of accuracy to investigate motion-based hypotheses is not trivial. However, radiographic-based motion measurement techniques have provided the advancement necessary to investigate motion-based hypotheses and provide a mechanistic understanding of shoulder function. Thus, the purpose of this article is to describe the approaches for measuring shoulder motion using a custom biplanar videoradiography system. The specific objectives of this article are to describe the protocols to acquire biplanar videoradiographic images of the shoulder complex, acquire CT scans, develop 3D bone models, locate anatomical landmarks, track the position and orientation of the humerus, scapula, and torso from the biplanar radiographic images, and calculate the kinematic outcome measures. In addition, the article will describe special considerations unique to the shoulder when measuring joint kinematics using this approach.


Assuntos
Movimento , Manguito Rotador/fisiologia , Articulação do Ombro/fisiologia , Ombro/fisiologia , Tomografia Computadorizada por Raios X/métodos , Gravação de Videoteipe , Fenômenos Biomecânicos , Feminino , Humanos , Pessoa de Meia-Idade , Ombro/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA