Anesth Analg ; 138(3): 552-561, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38109495

RESUMO

BACKGROUND: Retrospective clinical trials of pulse oximeter accuracy report more frequent missed diagnoses of hypoxemia in hospitalized Black patients than White patients, differences that may contribute to racial disparities in health and health care. Retrospective studies have limitations including mistiming of blood samples and oximeter readings, inconsistent use of functional versus fractional saturation, and self-reported race used as a surrogate for skin color. Our objective was to prospectively measure the contributions of skin pigmentation, perfusion index (PI), sex, and age on pulse oximeter errors in a laboratory setting. METHODS: We enrolled 146 healthy subjects, including 25 with light skin (Fitzpatrick class I and II), 78 with medium (class III and IV), and 43 with dark (class V and VI) skin. We studied 2 pulse oximeters (Nellcor N-595 and Masimo Radical 7) in prevalent clinical use. We analyzed 9763 matched pulse oximeter readings (pulse oximeter measured functional saturation [Sp o2 ]) and arterial oxygen saturation (hemoximetry arterial functional oxygen saturation [Sa o2 ]) during stable hypoxemia (Sa o2 68%-100%). PI was measured as percent infrared light modulation by the pulse detected by the pulse oximeter probe, with low perfusion categorized as PI < 1%. The primary analysis was to assess the relationship between pulse oximeter bias (difference between Sa o2 and Sp o2 ) by skin pigment category in a multivariable mixed-effects model incorporating repeated-measures and different levels of Sa o2 and perfusion. RESULTS: Skin pigment, PI, and degree of hypoxemia significantly contributed to errors (bias) in both pulse oximeters. For PI values of 1.0% to 1.5%, 0.5% to 1.0%, and <0.5%, the P value of the relationship to mean bias or median absolute bias was <.00001. In lightly pigmented subjects, only PI was associated with positive bias, whereas in medium and dark subjects bias increased with both low perfusion and degree of hypoxemia. Sex and age was not related to pulse oximeter bias. The combined frequency of missed diagnosis of hypoxemia (pulse oximeter readings 92%-96% when arterial oxygen saturation was <88%) in low perfusion conditions was 1.1% for light, 8.2% for medium, and 21.1% for dark skin. CONCLUSIONS: Low peripheral perfusion combined with darker skin pigmentation leads to clinically significant high-reading pulse oximeter errors and missed diagnoses of hypoxemia. Darkly pigmented skin and low perfusion states are likely the cause of racial differences in pulse oximeter performance in retrospective studies.


Assuntos
Diagnóstico Ausente , Oximetria , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Hipóxia/diagnóstico , Oxigênio , Perfusão
2.
Proc Natl Acad Sci U S A ; 115(45): E10740-E10747, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30348769

RESUMO

Orexin (also known as hypocretin) neurons in the hypothalamus play an essential role in sleep-wake control, feeding, reward, and energy homeostasis. The likelihood of anesthesia and sleep sharing common pathways notwithstanding, it is important to understand the processes underlying emergence from anesthesia. In this study, we investigated the role of the orexin system in anesthesia emergence, by specifically activating orexin neurons utilizing the designer receptors exclusively activated by designer drugs (DREADD) chemogenetic approach. With injection of adeno-associated virus into the orexin-Cre transgenic mouse brain, we expressed the DREADD receptor hM3Dq specifically in orexin neurons and applied the hM3Dq ligand clozapine to activate orexin neurons. We monitored orexin neuronal activities by c-Fos staining and whole-cell patch-clamp recording and examined the consequence of orexin neuronal activation via EEG recording. Our results revealed that the orexin-DREADD mice with activated orexin neurons emerged from anesthesia with significantly shorter latency than the control mice. As an indication of reduced pain sensitivity, these orexin-DREADD mice took longer to respond to the 55 °C thermal stimuli in the hot plate test and exhibited significantly less frequent licking of the formalin-injected paw in the formalin test. Our study suggests that approaches to activate the orexin system can be beneficial in postoperative recovery.


Assuntos
Período de Recuperação da Anestesia , Hipotálamo/metabolismo , Neurônios/metabolismo , Receptores de Orexina/genética , Orexinas/genética , Dor/genética , Anestésicos Inalatórios , Animais , Clozapina/farmacologia , Dependovirus/genética , Dependovirus/metabolismo , Eletroencefalografia , Regulação da Expressão Gênica , Vetores Genéticos/química , Vetores Genéticos/metabolismo , Temperatura Alta , Hipotálamo/efeitos dos fármacos , Hipotálamo/fisiopatologia , Isoflurano , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Neurônios/efeitos dos fármacos , Neurônios/patologia , Receptores de Orexina/metabolismo , Orexinas/metabolismo , Dor/fisiopatologia , Dor/prevenção & controle , Medição da Dor , Técnicas de Patch-Clamp , Proteínas Proto-Oncogênicas c-fos/genética , Proteínas Proto-Oncogênicas c-fos/metabolismo , Antagonistas da Serotonina/farmacologia , Técnicas Estereotáxicas
3.
JAMA ; 331(24): 2075-2076, 2024 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-38809524

RESUMO

This Viewpoint discusses the recent use of forced nitrogen inhalation as capital punishment in Alabama and describes the body of evidence indicating that forced nitrogen inhalation is an inhumane practice.


Assuntos
Pena de Morte , Nitrogênio , Humanos , Pena de Morte/legislação & jurisprudência , Estados Unidos
4.
Anesthesiology ; 128(1): 97-108, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29084012

RESUMO

BACKGROUND: Cerebral oximetry (cerebral oxygen saturation; ScO2) is used to noninvasively monitor cerebral oxygenation. ScO2 readings are based on the fraction of reduced and oxidized hemoglobin as an indirect estimate of brain tissue oxygenation and assume a static ratio of arterial to venous intracranial blood. Conditions that alter cerebral blood flow, such as acute changes in PaCO2, may decrease accuracy. We assessed the performance of two commercial cerebral oximeters across a range of oxygen concentrations during normocapnia and hypocapnia. METHODS: Casmed FORE-SIGHT Elite (CAS Medical Systems, Inc., USA) and Covidien INVOS 5100C (Covidien, USA) oximeter sensors were placed on 12 healthy volunteers. The fractional inspired oxygen tension was varied to achieve seven steady-state levels including hypoxic and hyperoxic PaO2 values. ScO2 and simultaneous arterial and jugular venous blood gas measurements were obtained with both normocapnia and hypocapnia. Oximeter bias was calculated as the difference between the ScO2 and reference saturation using manufacturer-specified weighting ratios from the arterial and venous samples. RESULTS: FORE-SIGHT Elite bias was greater during hypocapnia as compared with normocapnia (4 ± 9% vs. 0 ± 6%; P < 0.001). The INVOS 5100C bias was also lower during normocapnia (5 ± 15% vs. 3 ± 12%; P = 0.01). Hypocapnia resulted in a significant decrease in mixed venous oxygen saturation and mixed venous oxygen tension, as well as increased oxygen extraction across fractional inspired oxygen tension levels (P < 0.0001). Bias increased significantly with increasing oxygen extraction (P < 0.0001). CONCLUSIONS: Changes in PaCO2 affect cerebral oximeter accuracy, and increased bias occurs with hypocapnia. Decreased accuracy may represent an incorrect assumption of a static arterial-venous blood fraction. Understanding cerebral oximetry limitations is especially important in patients at risk for hypoxia-induced brain injury, where PaCO2 may be purposefully altered.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/metabolismo , Dióxido de Carbono/sangue , Circulação Cerebrovascular/fisiologia , Oximetria/métodos , Oxigênio/sangue , Adulto , Feminino , Humanos , Masculino , Pressão Parcial , Artéria Radial/metabolismo , Adulto Jovem
5.
Anesthesiology ; 128(3): 520-530, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29200008

RESUMO

BACKGROUND: Pulse oximeter performance is degraded by motion artifacts and low perfusion. Manufacturers developed algorithms to improve instrument performance during these challenges. There have been no independent comparisons of these devices. METHODS: We evaluated the performance of four pulse oximeters (Masimo Radical-7, USA; Nihon Kohden OxyPal Neo, Japan; Nellcor N-600, USA; and Philips Intellivue MP5, USA) in 10 healthy adult volunteers. Three motions were evaluated: tapping, pseudorandom, and volunteer-generated rubbing, adjusted to produce photoplethsmogram disturbance similar to arterial pulsation amplitude. During motion, inspired gases were adjusted to achieve stable target plateaus of arterial oxygen saturation (SaO2) at 75%, 88%, and 100%. Pulse oximeter readings were compared with simultaneous arterial blood samples to calculate bias (oxygen saturation measured by pulse oximetry [SpO2] - SaO2), mean, SD, 95% limits of agreement, and root mean square error. Receiver operating characteristic curves were determined to detect mild (SaO2 < 90%) and severe (SaO2 < 80%) hypoxemia. RESULTS: Pulse oximeter readings corresponding to 190 blood samples were analyzed. All oximeters detected hypoxia but motion and low perfusion degraded performance. Three of four oximeters (Masimo, Nellcor, and Philips) had root mean square error greater than 3% for SaO2 70 to 100% during any motion, compared to a root mean square error of 1.8% for the stationary control. A low perfusion index increased error. CONCLUSIONS: All oximeters detected hypoxemia during motion and low-perfusion conditions, but motion impaired performance at all ranges, with less accuracy at lower SaO2. Lower perfusion degraded performance in all but the Nihon Kohden instrument. We conclude that different types of pulse oximeters can be similarly effective in preserving sensitivity to clinically relevant hypoxia.


Assuntos
Hipóxia/diagnóstico , Oximetria/instrumentação , Adulto , Algoritmos , Artefatos , Feminino , Humanos , Masculino , Movimento (Física) , Oxigênio , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
6.
Anesth Analg ; 126(2): 579-587, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29189269

RESUMO

BACKGROUND: Currently, no reliable method exists for continuous, noninvasive measurements of absolute cerebral blood flow (CBF). We sought to determine how changes measured by ultrasound-tagged near-infrared spectroscopy (UT-NIRS) compare with changes in CBF as measured by transcranial Doppler (TCD) in healthy volunteers during profound hypocapnia and hypercapnia. METHODS: Ten healthy volunteers were monitored with a combination of TCD, UT-NIRS (c-FLOW, Ornim Medical), as well as heart rate, blood pressure, end-tidal PCO2 (PEtCO2), end-tidal O2, and inspired O2. Inspired CO2 and minute ventilation were controlled to achieve 5 stable plateau goals of EtCO2 at 15-20, 25-30, 35-40, 45-50, and 55-60 mm Hg, for a total of 7 measurements per subject. CBF was assessed at a steady state, with the TCD designated as the reference standard. The primary analysis was a linear mixed-effect model of TCD and UT-NIRS flow with PEtCO2, which accounts for repeated measures. Receiver operating characteristic curves were determined for detection of changes in CBF. RESULTS: Hyperventilation (nadir PEtCO2 17.1 ± 2.4) resulted in significantly decreased mean flow velocity of the middle cerebral artery from baseline (to 79% ± 22%), but not a consistent decrease in UT-NIRS cerebral flow velocity index (n = 10; 101% ± 6% of baseline). Hypercapnia (peak PEtCO2 59.3 ± 3.3) resulted in a significant increase from baseline in both mean flow velocity of the middle cerebral artery (153% ± 25%) and UT-NIRS (119% ± 11%). Comparing slopes versus PEtCO2 as a percent of baseline for the TCD (1.7% [1.5%-2%]) and UT-NIRS (0.4% [0.3%-0.5%]) shows that the UT-NIRS slope is significantly flatter, P < .0001. Area under the receiver operating characteristic curve was significantly higher for the TCD than for UT-NIRS, 0.97 (95% confidence interval, 0.92-0.99) versus 0.75 (95% confidence interval, 0.66-0.82). CONCLUSIONS: Our data indicate that UT-NIRS cerebral flow velocity index detects changes in CBF only during hypercarbia but not hypocarbia in healthy subjects and with much less sensitivity than TCD. Additional refinement and validation are needed before widespread clinical utilization of UT-NIRS.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ultrassonografia Doppler Transcraniana/métodos , Adulto , Feminino , Humanos , Masculino , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/normas , Espectroscopia de Luz Próxima ao Infravermelho/normas , Ultrassonografia Doppler Transcraniana/normas
7.
Anesth Analg ; 125(1): 124-138, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28489640

RESUMO

Implanted electronic medical devices. or stimulators such as pacemakers and nerve stimulators have grown enormously in diversity and complexity over recent decades. The function and potential interaction of these devices with the perioperative environment is of increasing concern for anesthesiologists and surgeons. Because of the innate electromagnetic environment of the hospital (operating room, gastrointestinal procedure suite, and imaging suite), implanted device malfunction, reprogramming, or destruction may occur and cause physical harm (including nerve injury, blindness, deafness, burn, stroke, paralysis, or coma) to the patient. It is critical for the anesthesiologist and surgeon to be aware of the function and interaction of implanted devices, both with other implanted devices and procedures (such as magnetic resonance imaging and cardioversion) in the hospital environment. Because of these interactions, it is imperative that proper device function is assessed when the surgical procedure is complete. This review article will discuss these important issues for 12 different types of "little black boxes," or noncardiac implantable electronic medical devices.


Assuntos
Anestesiologia/métodos , Cardioversão Elétrica/instrumentação , Eletrodos Implantados , Próteses Neurais , Assistência Perioperatória/instrumentação , Anestésicos , Desfibriladores Implantáveis , Campos Eletromagnéticos , Eletrônica , Endoscopia , Gânglios Espinais , Humanos , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Segurança do Paciente , Nervo Frênico , Período Pós-Operatório , Retina , Sacro/inervação , Medula Espinal , Estimulação Elétrica Nervosa Transcutânea , Nervo Vago
8.
Anesth Analg ; 124(1): 146-153, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27529318

RESUMO

Extended periods of oxygen deprivation can produce acidosis, inflammation, energy failure, cell stress, or cell death. However, brief profound hypoxia (here defined as SaO2 50%-70% for approximately 10 minutes) is not associated with cardiovascular compromise and is tolerated by healthy humans without apparent ill effects. In contrast, chronic hypoxia induces a suite of adaptations and stresses that can result in either increased tolerance of hypoxia or disease, as in adaptation to altitude or in the syndrome of chronic mountain sickness. In healthy humans, brief profound hypoxia produces increased minute ventilation and increased cardiac output, but little or no alteration in blood chemistry. Central nervous system effects of acute profound hypoxia include transiently decreased cognitive performance, based on alterations in attention brought about by interruptions of frontal/central cerebral connectivity. However, provided there is no decrease in cardiac output or ischemia, brief profound hypoxemia in healthy humans is well tolerated without evidence of acidosis or lasting cognitive impairment.


Assuntos
Hipóxia/diagnóstico , Oximetria , Oxigênio/sangue , Acidose/etiologia , Acidose/fisiopatologia , Doença Aguda , Adaptação Fisiológica , Animais , Atenção , Biomarcadores/sangue , Encéfalo/fisiopatologia , Débito Cardíaco , Cognição , Transtornos Cognitivos/etiologia , Transtornos Cognitivos/fisiopatologia , Transtornos Cognitivos/psicologia , Modelos Animais de Doenças , Humanos , Hipóxia/sangue , Hipóxia/complicações , Hipóxia/fisiopatologia , Valor Preditivo dos Testes , Ventilação Pulmonar , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo
11.
Anesth Analg ; 123(2): 338-45, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27089002

RESUMO

BACKGROUND: Universal access to pulse oximetry worldwide is often limited by cost and has substantial public health consequences. Low-cost pulse oximeters have become increasingly available with limited regulatory agency oversight. The accuracy of these devices often has not been validated, raising questions about performance. METHODS: The accuracy of 6 low-cost finger pulse oximeters during stable arterial oxygen saturations (SaO2) between 70% and 100% was evaluated in 22 healthy subjects. Oximeters tested were the Contec CMS50DL, Beijing Choice C20, Beijing Choice MD300C23, Starhealth SH-A3, Jumper FPD-500A, and Atlantean SB100 II. Inspired oxygen, nitrogen, and carbon dioxide partial pressures were monitored and adjusted via a partial rebreathing circuit to achieve 10 to 12 stable target SaO2 plateaus between 70% and 100% and PaCO2 values of 35 to 45 mm Hg. Comparisons of pulse oximeter readings (SpO2) with arterial SaO2 (by Radiometer ABL90 and OSM3) were used to calculate bias (SpO2 - SaO2) mean, precision (SD of the bias), and root mean square error (ARMS). RESULTS: Pulse oximeter readings corresponding to 536 blood samples were analyzed. Four of the 6 oximeters tested showed large errors (up to -6.30% mean bias, precision 4.30%, 7.53 ARMS) in estimating saturation when SaO2 was reduced <80%, and half of the oximeters demonstrated large errors when estimating saturations between 80% and 90%. Two of the pulse oximeters tested (Contec CMS50DL and Beijing Choice C20) demonstrated ARMS of <3% at SaO2 between 70% and 100%, thereby meeting International Organization for Standardization (ISO) criteria for accuracy. CONCLUSIONS: Many low-cost pulse oximeters sold to consumers demonstrate highly inaccurate readings. Unexpectedly, the accuracy of some low-cost pulse oximeters tested here performed similarly to more expensive, ISO-cleared units when measuring hypoxia in healthy subjects. None of those tested here met World Federation of Societies of Anaesthesiologists standards, and the ideal testing conditions do not necessarily translate these findings to the clinical setting. Nonetheless, further development of accurate, low-cost oximeters for use in clinical practice is feasible and, if pursued, could improve access to safe care, especially in low-income countries.


Assuntos
Aprovação de Equipamentos , Saúde Global , Oximetria/instrumentação , Oxigênio/sangue , United States Food and Drug Administration , Adulto , Biomarcadores/sangue , Desenho de Equipamento , Feminino , Saúde Global/economia , Custos de Cuidados de Saúde , Voluntários Saudáveis , Humanos , Masculino , Teste de Materiais , Oximetria/economia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estados Unidos
12.
Anesthesiology ; 119(2): 335-44, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23591069

RESUMO

BACKGROUND: Anesthetic neurotoxicity in the developing brain of rodents and primates has raised concern. Xenon may be a nonneurotoxic alternative to halogenated anesthetics, but its toxicity has only been studied at low concentrations, where neuroprotective effects predominate in animal models. An equipotent comparison of xenon and halogenated anesthetics with respect to neurotoxicity in developing neurons has not been made. METHODS: Organotypic hippocampal cultures from 7-day-old rats were exposed to 0.75, 1, and 2 minimum alveolar concentrations (MAC) partial pressures (60% xenon at 1.2, 2.67, and 3.67 atm; isoflurane at 1.4, 1.9, and 3.8%; and sevoflurane at 3.4 and 6.8%) for 6 h, at atmospheric pressure or in a pressure chamber. Cell death was assessed 24 h later with fluorojade and fluorescent dye exclusion techniques. RESULTS: Xenon caused death of hippocampal neurons in CA1, CA3, and dentate regions after 1 and 2 MAC exposures, but not at 0.75 MAC. At 1 MAC, xenon increased cell death 40% above baseline (P < 0.01; ANOVA with Dunnett test). Both isoflurane and sevoflurane increased neuron death at 1 but not 2 MAC. At 1 MAC, the increase in cell death compared with controls was 63% with isoflurane and 90% with sevoflurane (both P < 0.001). Pretreatment of cultures with isoflurane (0.75 MAC) reduced neuron death after 1 MAC xenon, isoflurane, and sevoflurane. CONCLUSION: Xenon causes neuronal cell death in an in vitro model of the developing rodent brain at 1 MAC, as does isoflurane and sevoflurane at similarly potent concentrations. Preconditioning with a subtoxic dose of isoflurane eliminates this toxicity.


Assuntos
Anestésicos Inalatórios/toxicidade , Hipocampo/efeitos dos fármacos , Isoflurano/toxicidade , Éteres Metílicos/toxicidade , Xenônio/toxicidade , Animais , Animais Recém-Nascidos , Morte Celular/efeitos dos fármacos , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Feminino , Masculino , Neurônios/efeitos dos fármacos , Técnicas de Cultura de Órgãos , Ratos , Ratos Sprague-Dawley , Sevoflurano
13.
Anesth Analg ; 117(4): 813-823, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24023027

RESUMO

BACKGROUND: Cerebral oximetry is a noninvasive optical technology that measures frontal cortex blood hemoglobin-oxygen saturation. Commercially available cerebral oximeters have not been evaluated independently. Unlike pulse oximeters, there are currently no Food and Drug Administration standards for performance or accuracy. We tested the hypothesis that cerebral oximeters accurately measure a fixed ratio of the oxygen saturation in cerebral mixed venous and arterial blood. METHODS: We evaluated the performance of 5 commercially available cerebral oximeters: the EQUANOX® 7600 in 3- and 4-wavelength versions (Nonin Medical, Plymouth, MN), FORE-SIGHT® (Casmed, Branford, CT), INVOS® 5100C (Covidien, Boulder, CO), and the NIRO-200NX® (Hamamatsu Photonics, Hamamatsu City, Japan) during stable isocapnic hypoxia in volunteers. Twenty-three healthy adults (14 men, 9 women) had sensors placed on each side of the forehead. The subject's inspired oxygen (FIO2) was then changed to produce 6 steady-state arterial oxygen saturation (SaO2) levels between 100% and 70%, while end-tidal CO2 was maintained constant. At each plateau, simultaneous blood samples from the jugular bulb and radial artery were analyzed with a hemoximeter (OSM-3, Radiometer Medical A/S, Copenhagen, Denmark). Each cerebral oximeter's bias was calculated as the difference between the instrument's reading (cerebral saturation, ScO2) with the weighted saturation of venous and arterial blood (Sa/vO2), as specified by each manufacturer (INVOS: 25% arterial/75% venous; FORE-SIGHT, EQUANOX, and NIRO: 30% arterial/70% venous). RESULTS: Five hundred forty-two comparisons between paired blood samples and oximeter readings were analyzed. The pooled root mean square error was 8.06%, a value higher than for pulse oximeters, which is ±3% by Food and Drug Administration standards. The mean % bias ± SD (precision) and root mean square errors were: FORE-SIGHT 1.76 ± 3.92 and 4.28; INVOS 0.05 ± 9.72 and 9.69; NIRO-200NX -1.13 ± 9.64 and 9.68; EQUANOX-3 λ 2.48 ± 8.12 and 8.47; EQUANOX-4 λ 2.84 ± 6.27 and 6.86. The FORE-SIGHT, NIRO-200NX, and EQUANOX-3 λ had significantly more positive bias at lower SaO2. The amount of bias during hypoxia was reduced when the bias was calculated on the basis of difference between oximeter reading and the arterial and mixed venous saturation difference rather than the weighted average of blood saturation, indicating that differences in the ratio between arterial and venous blood volumes account for some of the positive bias at low saturation. Dark skin pigment tended to produce more negative bias in all instruments but bias was significantly larger than zero only for the FORE-SIGHT oximeter. Bias was significantly more negative in women for INVOS and EQUANOX devices but not for the FORE-SIGHT device. CONCLUSIONS: While responsive to desaturation, cerebral oximeters exhibited large variation in reading errors between subjects, with mean bias possibly related to variations in the ratio of arterial and venous blood in the sampling area of the brain. This ratio is probably not fixed, as assumed by the manufacturers, but dynamically changes with hypoxia. Better understanding these factors could improve the performance of cerebral oximeters and help establish saturation or blood flow thresholds for brain well-being.


Assuntos
Hipóxia/sangue , Oximetria/instrumentação , Oximetria/métodos , Adulto , Encéfalo/metabolismo , Feminino , Humanos , Hipóxia/diagnóstico , Masculino , Pessoa de Meia-Idade , Oximetria/normas , Consumo de Oxigênio , Fatores Sexuais , Pigmentação da Pele/fisiologia , Adulto Jovem
14.
Anesth Analg ; 117(4): 847-858, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23477959

RESUMO

BACKGROUND: Carbon monoxide poisoning is a significant problem in most countries, and a reliable method of quick diagnosis would greatly improve patient care. Until the recent introduction of a multiwavelength "pulse CO-oximeter" (Masimo Rainbow SET(®) Radical-7), obtaining carboxyhemoglobin (COHb) levels in blood required blood sampling and laboratory analysis. In this study, we sought to determine whether hypoxemia, which can accompany carbon monoxide poisoning, interferes with the accurate detection of COHb. METHODS: Twelve healthy, nonsmoking, adult volunteers were fitted with 2 standard pulse-oximeter finger probes and 2 Rainbow probes for COHb detection. A radial arterial catheter was placed for blood sampling during 3 interventions: (1) increasing hypoxemia in incremental steps with arterial oxygen saturations (SaO2) of 100% to 80%; (2) normoxia with incremental increases in %COHb to 12%; and (3) elevated COHb combined with hypoxemia with SaO2 of 100% to 80%. Pulse-oximeter (SpCO) readings were compared with simultaneous arterial blood values at the various increments of hypoxemia and carboxyhemoglobinemia (≈25 samples per subject). Pulse CO-oximeter performance was analyzed by calculating the mean bias (SpCO - %COHb), standard deviation of the bias (precision), and the root-mean-square error (A(rms)). RESULTS: The Radical-7 accurately detected hypoxemia with both normal and elevated levels of COHb (bias mean ± SD: 0.44% ± 1.69% at %COHb <4%, and -0.29% ± 1.64% at %COHb ≥4%, P < 0.0001, and A(rms) 1.74% vs 1.67%). COHb was accurately detected during normoxia and moderate hypoxia (bias mean ± SD: -0.98 ± 2.6 at SaO2 ≥95%, and -0.7 ± 4.0 at SaO2 <95%, P = 0.60, and A(rms) 2.8% vs 4.0%), but when SaO2 decreased below approximately 85%, the pulse CO-oximeter always gave low signal quality errors and did not report SpCO values. CONCLUSIONS: In healthy volunteers, the Radical-7 pulse CO-oximeter accurately detects hypoxemia with both low and elevated COHb levels, and accurately detects COHb, but only reads SpCO when SaO2 is more than approximately 85%.


Assuntos
Carboxihemoglobina/metabolismo , Hipóxia/sangue , Oximetria/métodos , Oximetria/normas , Adolescente , Adulto , Intoxicação por Monóxido de Carbono/diagnóstico , Feminino , Humanos , Hipóxia/diagnóstico , Masculino , Pessoa de Meia-Idade , Adulto Jovem
15.
Toxins (Basel) ; 15(1)2023 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-36668869

RESUMO

Respiratory and airway-protective muscle weakness caused by the blockade of neuromuscular transmission is a major cause of early mortality from snakebite envenoming (SBE). Once weakness is manifest, antivenom appears to be of limited effectiveness in improving neuromuscular function. Herein, we review the topic of venom-induced neuromuscular blockade and consider the utility of adopting clinical management methods originally developed for the safe use of neuromuscular blocking agents by anesthesiologists in operating rooms and critical care units. Failure to quantify neuromuscular weakness in SBE is predicted to cause the same significant morbidity that is associated with failure to do so in the context of using a clinical neuromuscular block in surgery and critical care. The quantitative monitoring of a neuromuscular block, and an understanding of its neurophysiological characteristics, enables an objective measurement of weakness that may otherwise be overlooked by traditional clinical examination at the bedside. This is important for the initial assessment and the monitoring of recovery from neurotoxic envenoming. Adopting these methods will also be critical to the conduct of future clinical trials of toxin-inhibiting drugs and antivenoms being tested for the reversal of venom-induced neuromuscular block.


Assuntos
Bloqueio Neuromuscular , Bloqueadores Neuromusculares , Mordeduras de Serpentes , Humanos , Mordeduras de Serpentes/terapia , Mordeduras de Serpentes/tratamento farmacológico , Paralisia/tratamento farmacológico , Bloqueio Neuromuscular/métodos , Bloqueadores Neuromusculares/uso terapêutico , Antivenenos/uso terapêutico
16.
J Am Geriatr Soc ; 71(1): 227-234, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36125032

RESUMO

BACKGROUND: Postoperative delirium is a common postsurgical complication in older patients and is associated with high morbidity and mortality. The objective of this study was to determine whether a digital cognitive assessment and patient characteristics could identify those at-risk. METHODS: Patients 65 years and older undergoing spine surgeries ≥3 h were evaluated as part of a single-center prospective observational cohort study at an academic medical center, from January 1, 2019, to December 31, 2020. Of 220 eligible patients, 161 were enrolled and 152 completed the study. The primary outcome of postoperative delirium was measured by the Confusion Assessment Method for the Intensive Care Unit or the Nursing Delirium Screening Scale, administered by trained nursing staff independent from the study protocol. Baseline cognitive impairment was identified using the tablet-based TabCAT Brain Health Assessment. RESULTS: Of the 152 patients included in this study, 46% were women. The mean [SD] age was 72 [5.4] years. Baseline cognitive impairment was identified in 38% of participants, and 26% had postoperative delirium. In multivariable analysis, impaired Brain Health Assessment Cognitive Score (OR 2.45; 95% CI, 1.05-5.67; p = 0.037), depression (OR 4.54; 95% CI, 1.73-11.89; p = 0.002), and higher surgical complexity Tier 4 (OR 5.88; 95% CI, 1.55-22.26; p = 0.009) were associated with postoperative delirium. The multivariate model was 72% accurate for predicting postoperative delirium, compared to 45% for the electronic medical record-based risk stratification model currently in use. CONCLUSION: In this prospective cohort study of spine surgery patients, age, cognitive impairment, depression, and surgical complexity identified patients at high risk for postoperative delirium. Integration of scalable digital assessments into preoperative workflows could identify high-risk patients, automate decision support for timely interventions that can improve patient outcomes and lower hospital costs, and provide a baseline cognitive assessment to monitor for postoperative cognitive change.


Assuntos
Disfunção Cognitiva , Delírio , Delírio do Despertar , Humanos , Feminino , Idoso , Masculino , Estudos Prospectivos , Delírio do Despertar/complicações , Delírio/diagnóstico , Delírio/etiologia , Delírio/psicologia , Fatores de Risco , Disfunção Cognitiva/psicologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/psicologia
17.
Anesthesiology ; 117(5): 1080-90, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23001052

RESUMO

BACKGROUND: Propofol in the early postnatal period has been shown to cause brain cell death. One proposed mechanism for cognitive dysfunction after anesthesia is alteration of neural stem cell function and neurogenesis. We examined the effect of propofol on neural precursor or stem cells (NPCs) grown in vitro. METHODS: Hippocampal-derived NPCs from postnatal day 2 rats were exposed to propofol or Diprivan. NPCs were then analyzed for bromodeoxyuridine incorporation to measure proliferation. Cell death was measured by lactate dehydrogenase release. Immunocytochemistry was used to evaluate the expression of neuronal and glial markers in differentiating NPCs exposed to propofol. RESULTS: Propofol dose dependently increases the release of lactate dehydrogenase from NPCs under both proliferating and differentiating conditions at supraclinical concentrations (more than 7.1 µM). Both Diprivan and propofol had the same effect on NPCs. Propofol-mediated release of lactate dehydrogenase is not inhibited by blocking the γ-aminobutyric acid type A receptor or extracellular calcium influx and is not mediated by caspase-3/7. Direct γ-aminobutyric acid type A receptor activation did not have the same effect. In differentiating NPCs, 6 h of propofol at 2.1 µM increased the number neurons but not glial cells 4 days later. Increased neuronal differentiation was not blocked by bicuculline. CONCLUSIONS: Only supraclinical concentrations of propofol or Diprivan kill NPCs in culture by a non-γ-aminobutyric acid type A, noncaspase-3 mechanism. Clinically relevant doses of propofol increase neuronal fate choice by a non-γ-aminobutyric acid type A mechanism.


Assuntos
Diferenciação Celular/efeitos dos fármacos , Hipocampo/citologia , Hipocampo/efeitos dos fármacos , Células-Tronco Neurais/efeitos dos fármacos , Neurônios/citologia , Propofol/farmacologia , Animais , Animais Recém-Nascidos , Diferenciação Celular/fisiologia , Células Cultivadas , Relação Dose-Resposta a Droga , Hipocampo/crescimento & desenvolvimento , Células-Tronco Neurais/fisiologia , Neurogênese/efeitos dos fármacos , Neurogênese/fisiologia , Neurônios/efeitos dos fármacos , Neurônios/fisiologia , Propofol/toxicidade , Ratos , Ratos Sprague-Dawley
18.
Anesthesiology ; 117(2): 280-92, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22728782

RESUMO

BACKGROUND: Mild hypothermia is neuroprotective after cerebral ischemia but surgery involving profound hypothermia (PH, temperature less than 18°C) is associated with neurologic complications. Rewarming (RW) from PH injures hippocampal neurons by glutamate excitotoxicity, N-methyl-D-aspartate receptors, and intracellular calcium. Because neurons are protected from hypoxia-ischemia by anesthetic agents that inhibit N-methyl-D-aspartic acid receptors, we tested whether anesthetics protect neurons from damage caused by PH/RW. METHODS: Organotypic cultures of rat hippocampus were used to model PH/RW injury, with hypothermia at 4°C followed by RW to 37°C and assessment of cell death 1 or 24 h later. Cell death and intracellular Ca were assessed with fluorescent dye imaging and histology. Anesthetic agents were present in the culture media during PH and RW or only RW. RESULTS: Injury to hippocampal CA1, CA3, and dentate neurons after PH and RW involved cell swelling, cell rupture, and adenosine triphosphate (ATP) loss; this injury was similar for 4 through 10 h of PH. Isoflurane (1% and 2%), sevoflurane (3%) and xenon (60%) reduced cell loss but propofol (3 µM) and pentobarbital (100 µM) did not. Isoflurane protection involved reduction in N-methyl-D-aspartate receptor-mediated Ca influx during RW but did not involve γ-amino butyric acid receptors or KATP channels. However, cell death increased over the next day. CONCLUSION: Anesthetic protection of neurons rewarmed from 4°C involves suppression of N-methyl-D-aspartate receptor-mediated Ca overload in neurons undergoing ATP loss and excitotoxicity. Unlike during hypoxia/ischemia, anesthetic agents acting predominantly on γ-aminobutyric acid receptors do not protect against PH/RW. The durability of anesthetic protection against cold injury may be limited.


Assuntos
Anestésicos/farmacologia , Cálcio/metabolismo , Hipotermia/metabolismo , Neurônios/efeitos dos fármacos , Neurônios/metabolismo , Reaquecimento , Análise de Variância , Animais , Morte Celular/efeitos dos fármacos , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática , Ácido Glutâmico/efeitos dos fármacos , Ácido Glutâmico/metabolismo , Hipocampo/efeitos dos fármacos , Hipocampo/metabolismo , Hipocampo/patologia , Hipotermia/patologia , Hipóxia/patologia , Neurônios/patologia , Fármacos Neuroprotetores/farmacologia , Ratos , Ratos Endogâmicos SHR , Receptores de N-Metil-D-Aspartato/efeitos dos fármacos , Receptores de N-Metil-D-Aspartato/metabolismo
19.
Anesthesiology ; 116(3): 586-602, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22354242

RESUMO

BACKGROUND: Anesthesia given to immature rodents causes cognitive decline, raising the possibility that the same might be true for millions of children undergoing surgical procedures under general anesthesia each year. We tested the hypothesis that anesthesia-induced cognitive decline in rats is treatable. We also tested if anesthesia-induced cognitive decline is aggravated by tissue injury. METHODS: Seven-day old rats underwent sevoflurane anesthesia (1 minimum alveolar concentration, 4 h) with or without tail clamping. At 4 weeks, rats were randomized to environmental enrichment or normal housing. At 8 weeks rats underwent neurocognitive testing, which consisted of fear conditioning, spatial reference memory, and water maze-based memory consolidation tests, and interrogated working memory, short-term memory, and early long-term memory. RESULTS: Sevoflurane-treated rats had a greater escape latency when the delay between memory acquisition and memory retrieval was increased from 1 min to 1 h, indicating that short-term memory was impaired. Delayed environmental enrichment reversed the effects of sevoflurane on short-term memory and generally improved many tested aspects of cognitive function, both in sevoflurane-treated and control animals. The performance of tail-clamped rats did not differ from those rats receiving anesthesia alone. CONCLUSION: Sevoflurane-induced cognitive decline in rats is treatable. Delayed environmental enrichment rescued the sevoflurane-induced impairment in short-term memory. Tissue injury did not worsen the anesthesia-induced memory impairment. These findings may have relevance to neonatal and pediatric anesthesia.


Assuntos
Abrigo para Animais , Transtornos da Memória/induzido quimicamente , Transtornos da Memória/terapia , Éteres Metílicos/toxicidade , Fatores Etários , Animais , Animais Recém-Nascidos , Masculino , Aprendizagem em Labirinto/efeitos dos fármacos , Aprendizagem em Labirinto/fisiologia , Transtornos da Memória/fisiopatologia , Distribuição Aleatória , Ratos , Ratos Sprague-Dawley , Sevoflurano , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA