Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artif Organs ; 48(10): 1168-1179, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38803239

RESUMO

BACKGROUND: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. METHODS: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. RESULTS: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. CONCLUSIONS: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.


Assuntos
Coração Auxiliar , Sistema de Registros , Humanos , Coração Auxiliar/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Incidência , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Insuficiência Cardíaca/terapia , AVC Isquêmico/etiologia , AVC Isquêmico/epidemiologia , Resultado do Tratamento , Acidente Vascular Cerebral Hemorrágico/etiologia , Acidente Vascular Cerebral Hemorrágico/epidemiologia
2.
Thorac Cardiovasc Surg ; 70(6): 458-466, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35817063

RESUMO

OBJECTIVES: Cardiac support systems are being used increasingly more due to the growing prevalence of heart failure and cardiogenic shock. Reducing cardiac afterload, intracardiac pressure, and flow support are important factors. Extracorporeal membrane oxygenation (ECMO) and intracardiac microaxial pump systems (Impella) as non-permanent MCS (mechanical circulatory support) are being used increasingly. METHODS: We reviewed the recent literature and developed an international European registry for non-permanent MCS. RESULTS: Life-threatening conditions that are observed preoperatively often include reduced left ventricular function, systemic hypoperfusion, myocardial infarction, acute and chronic heart failure, myocarditis, and valve vitia. Postoperative complications that are commonly observed include severe systemic inflammatory response, ischemia-reperfusion injury, trauma-related disorders, which ultimately may lead to low cardiac output (CO) syndrome and organ dysfunctions, which necessitates a prolonged ICU stay. Choosing the appropriate device for support is critical. The management strategies and complications differ by system. The "heart-team" approach is inevitably needed.However despite previous efforts to elucidate these topics, it remains largely unclear which patients benefit from certain systems, when is the right time to initiate (MCS), which support system is appropriate, what is the optimal level and type of support, which therapeutic additive and supportive strategies should be considered and ultimately, what are the future prospects and therapeutic developments. CONCLUSION: The European cardiac surgical register ImCarS has been established as an IIT with the overall aim to evaluate data received from the daily clinical practice in cardiac surgery. Interested colleagues are cordially invited to join the register. CLINICAL REGISTRATION NUMBER: DRKS00024560. POSITIVE ETHICS VOTE: AZ 246/20 Faculty of Medicine, Justus-Liebig-University-Gießen.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Coração Auxiliar , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
5.
Thorac Cardiovasc Surg ; 63(6): 487-92, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26005908

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a recognized therapeutic option for high-risk and inoperable patients with aortic valve stenosis. The choice of access route is a matter of debate. We are presenting our 5-year experience of transapical TAVI dominance. PATIENTS: This single-center study includes 575 patients. Two groups were compared: transapical (TA) and transfemoral (TF) with 454 and 121 patients, respectively. Individual access route decision was made by our heart team following a clinical and computed tomography (CT) data based nonbiased strategy. The same team performed all procedures. The mean logistic EuroSCORE was significantly higher in the TA group, however, without difference in STS score. The number of patients with coronary artery disease, previous cardiac surgery, and low left ventricular ejection fraction was higher in the TA group. There were no significant differences in age and presence of other comorbidities. RESULTS: Procedural success in both TA and TF groups was high (97.9% and 97.6%). No patient died during the procedure. Patient survival (30 days: TF, 97.5% vs. TA, 95.7%; 1 year: TF, 94.6% vs. TA, 81.8%; 2 years: TF, 84.7% vs. TA, 76.7%; 3 years: TF, 59.9% vs. TA, 67.8%) and a low TF vascular complication rate (1.6%) are encouraging compared with other registry data. CONCLUSION: A "no competition" team approach strategy along with an experienced hybrid team leads to fewer vascular complications and better outcomes for both TA and TF TAVI patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Complicações Pós-Operatórias/epidemiologia , Guias de Prática Clínica como Assunto , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/normas , Feminino , Seguimentos , Alemanha/epidemiologia , Virilha , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/prevenção & controle , Radiografia , Sistema de Registros , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/normas , Resultado do Tratamento
6.
J Phys Chem A ; 116(30): 8015-22, 2012 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-22780095

RESUMO

Modulation of organic semiconductor band gap, electron affinities (EA), ionization potentials (IP), and reorganization energies (λ) associated with charge transfer is critical for its applications. We report here that trifluoromethylation not only increases both IP and EA significantly as expected but also narrows the HOMO-LUMO band gaps and increases considerably the air-stability of arene-based n-type organic semiconductors. The increased air-stability results from relatively high EA energies and a change in oxidation mechanism. Calculated EAs and IPs show that trifluoromethylated arenes are excellent candidates for n-type semiconductor materials; though a moderate increase of inner-sphere reorganization energy (λi) associated with charge transfer is the penalty for the improved performance of the trifluoromethylated compounds. However, since λi decreases as the π conjugation increases, a rational design to produce air-stable n-type semiconductor materials with reasonably small λi is simply to prepare trifluoromethylated arenes with extended π conjugation. Furthermore, we found that structural isomerization can fine-tune the optoelectronic and electronic transfer properties of the corresponding aromatics.

7.
Open Heart ; 7(1): e001194, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32153791

RESUMO

Background: A logistic European System for Cardiac Operative Risk Evaluation (logEuroSCORE) ≥20% is frequently recognised as a finite criteria for transcatheter aortic valve implantation (TAVI) reimbursement, despite guideline modifications to reflect the appropriacy of TAVI in selected lower-risk patients. The aim was to evaluate the clinical value of this threshold cut-off in TAVI patients and to identify factors associated with mortality in those below this threshold. Methods: We analysed data from a single-centre, German, observational, TAVI-patient registry, gathered between 2008 and 2016. Patients were stratified by logEuroSCORE (≥ or <20%) for comparisons. Logistic regression was performed to identify predictors of mortality at 1 year, with this analysis used to generate a calculated ('real') risk value for each patient. Results: 1679 patients (logEuroSCORE <20%: n=789; logEuroSCORE ≥20%: n=890) were included. LogEuroSCORE <20% patients were significantly younger (80.1 vs 81.6 years; p<0.001) and less comorbid than logEuroSCORE ≥20% patients, with a higher rate of transfemoral TAVI (35.6% vs 26.1%; p<0.001) and predilation (70.0% vs 63.3%; p=0.004). Patients with a logEuroSCORE <20% experienced more vascular complications (3.4% vs 1.5%; p=0.010). One-year survival was 88.3% in the logEuroSCORE <20% and 81.8% in the logEuroSCORE ≥20% group (p=0.005), with the calculated mortality risk falling within 2% of the logEuroSCORE in just 12.9% of patients. In the logEuroSCORE <20% group, only coronary artery disease was significantly predictive of 1-year mortality (OR 2.408; 95% CI 1.361 to 4.262; p=0.003). Conclusions: At our institution, patients with a logEuroSCORE <20% selected for TAVI have excellent outcomes. The decision not to reimburse TAVI in such patients may be viewed as inappropriate.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Tomada de Decisão Clínica , Técnicas de Apoio para a Decisão , Definição da Elegibilidade , Seleção de Pacientes , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Definição da Elegibilidade/economia , Planos de Pagamento por Serviço Prestado , Feminino , Alemanha , Humanos , Masculino , Valor Preditivo dos Testes , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/economia , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
8.
J Heart Valve Dis ; 18(6): 713-6, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20099722

RESUMO

Catheter-based transapical aortic valve implantation (TA-AVI) in patients with severe stenosis of the aortic valve and with a high operative risk is a new procedure which is becoming established in clinical practice. Aortic regurgitation is not yet a recognized indication for TA-AVI, and to date valve-in-valve (V-in-V) implantation in patients with incompetent stentless bioprostheses has not been attempted. The case is reported of a successful TA-AVI in a regurgitant, uncalcified stentless Medtronic Freestyle bioprosthesis. The position and hemodynamic function of the apically implanted valve were excellent, and the patient's current state of health is good.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Falha de Prótese , Idoso , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos
9.
Interact Cardiovasc Thorac Surg ; 26(2): 224-229, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29049741

RESUMO

OBJECTIVES: It may be expected that patients with left ventricular dysfunction may be at greater risk of complications after transcatheter aortic valve implantation (TAVI) via transapical (TA) access compared with via transfemoral (TF) access. There is a lack of data comparing the outcomes of TAVI using TA and TF access in patients with a reduced left ventricular ejection fraction (EF). METHODS: This is a retrospective analysis of data from a high-volume heart centre in Germany. TAVI access route assignment was based on a 'best for TF' approach, where only patients who met a strict set of criteria underwent TF-TAVI, with the remainder receiving TA-TAVI. For this analysis, patients were included if they had a pre-TAVI EF of ≤ 40%. Early mortality and late (1-year) mortality were compared through multivariate logistic regression. RESULTS: A total of 342 patients in the registry had an EF of ≤ 40%, of which 74.9% underwent TA-TAVI and 25.1% underwent TF-TAVI. Higher proportions of the TA group presented with certain comorbidities, and their logistic EuroSCORE and Society of Thoracic Surgeons (STS) risk scores were higher than in the TF group. At 1 year, TA access was associated with greater mortality in the univariate analysis (odd ratio 2.43; 95% confidence interval 1.04-5.69). However, after multivariate adjustment, no significant differences were found in either 30-day or 1-year mortality rates. CONCLUSIONS: The data suggest that, for patients with a reduced EF, TA-TAVI is not associated with a poorer outcome compared with TF-TAVI. Therefore, TA access should not be discounted based on the presence of left ventricular dysfunction alone.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Razão de Chances , Estudos Retrospectivos , Volume Sistólico
10.
Kardiochir Torakochirurgia Pol ; 14(4): 215-224, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29354172

RESUMO

INTRODUCTION: The "transfemoral (TF) first" approach to access route selection in transcatheter aortic valve implantation (TAVI) is popular; however, the risk of major vascular complications is substantial. The "best for TF" approach identifies only the patients with ideal anatomy for TF-TAVI, potentially minimizing complications. AIM: To characterize the outcomes of patients undergoing TAVI at a large-volume site that employs this approach. MATERIAL AND METHODS: Patients who underwent TAVI at the Bad Rothenfelde Heart Centre between 2008 and 2016 were consecutively enrolled. Findings were compared to those from large, multicenter registries. RESULTS: Of the 1,644 patients enrolled, 1,140 underwent TA- and 504 TF-TAVI. Comorbidities were more frequent in TA patients, who also had higher risk scores (EuroSCORE: 25.5% vs. 21.2%; STS score: 11.0% vs. 7.5%; p < 0.001 for both). Rates of conversion to open surgery, major vascular complications and intra-procedural mortality did not differ between groups. At 30 days, mortality rates were higher in the TA group (3.9% vs. 1.9%, p = 0.036). Stroke/transient ischemic attack and permanent pacemaker implantation rates did not differ significantly between groups (2.0% and 9.1% overall, respectively). Compared to multicenter registries, trends in mortality and complication rates were similar, though magnitudes were lower in the present study. In contrast with the present study, major vascular complication rates in multicenter registries are significantly higher for TF compared to TA patients. CONCLUSIONS: At this high-volume center, the use of a "best for TF" approach to TAVI resulted in low mortality and complication rates.

11.
Ann Thorac Surg ; 96(6): e151-3, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24296227

RESUMO

Transapical transcatheter aortic valve implantation (TA-TAVI) is the method of choice in patients with severe stenosis of the aortic valve, high operative risk, and an adverse peripheral vasculature. The procedure is generally guided by peripheral arterial access angiography. We report on a 71-year-old patient in whom, because of the absence of an alternative peripheral arterial access route, TA-TAVI was supported by the apical insertion of the angiography catheter. This approach was effective and safe, and proper valve deployment was feasible without unexpected procedural complications.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Angiografia , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Humanos , Masculino , Desenho de Prótese , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA