RESUMO
Foreign body (FB) ingestion is a common clinical problem and most FBs pass through the gastrointestinal tract without the need for intervention. A wide spectrum of clinical presentations may be possible and these can be either acute or chronic. We present a case of an 83-year-old woman featuring insidious abdominal discomfort who was hospitalized in our institution due to worsening symptoms. She underwent contrast-enhanced computed tomography (CT) evaluation which showed the presence of a significant parietal thickening of the transverse and descending colon, a mesenteric loose tissue imbibition, venous engorgement, and no filling defect of visceral arteries, suggesting a condition of nonocclusive colon ischemia. A hyperdense FB was identified in the sigma and was associated with a small pseudotumoral mass. The patient underwent surgical exploration which confirmed the hypoperfusional state of the colon, showing the presence of a chicken bone perforating the sigma and lying in the context of a pseudotumoral mass. Our experience shows how contrast-enhanced CT is feasible and can be strongly recommended as a first-line imaging tool on suspicion of colon ischemia and also how it can easily identify the underlying cause, in our case a FB sealed perforation of the sigma with pseudotumoral mass formation.
RESUMO
The aim of our study was to compare the results of the TTE (transthoracic echocardiography) with the results obtained by the ECG-gated 64 slices CT during the followup of patients with bicuspid aortic valve (BAV), after aortic valve replacement; in particular we evaluated the aortic root and the ascending aorta looking for a new algorithm in the followup of these patients. From January 1999 to December 2009 our attention was focused on 67 patients with isolated surgical substitution of aortic valve; after dismissal they were strictly observed. During the period between May and September 2010, these patients underwent their last evaluation, and clinical exams, ECG, TTE, and an ECG-gated-MDCT were performed. At followup TTE results showed an aortic root of 36.7 ± 4 mm and an ascending aorta of 39.6 ± 4.8 mm. ECG- gated CT showed an aortic root of 37.9 ± 5.5 mm and an ascending aorta of 43.1 ± 5.2. The comparison between preoperative and postoperative TTE shows a significant long-term dilatation of the ascending aorta while the aortic root diameter seems to be stable. ECG-gated CT confirms the stability of the aortic root diameter (38.2 ± 5.3 mm versus 37.9 ± 5.5 mm; <0.0001) and the increasing diameter value of the ascending aorta (40.2 ± 3.9 mm versus 43.1 ± 5.2 mm; P = 0.0156). Due to the different findings between CT and TTE studies, ECG-gated CT should no longer be considered as a complementary exam in the followup of patients with BAV, but as a fundamental role since it is a real necessity.