Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiol Med ; 128(2): 234-241, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36637741

RESUMO

PURPOSE: To evaluate the added value of ultra-short echo time (UTE) and fast field echo resembling a CT using restricted echo-spacing (FRACTURE) MR sequences in the assessment of the osseous cervical spine using CT as reference. MATERIALS AND METHODS: Twenty-seven subjects underwent postmortem CT and MRI within 48 h. Datasets were anonymized and analyzed retrospectively by two radiologists. Morphological cervical spine alterations were rated on CT, UTE and FRACTURE images. Afterward, neural foraminal stenosis was graded on standard MR and again after viewing additional UTE/FRACTURE sequences. To evaluate interreader and intermodality reliability, intra-class correlation coefficients (ICC) and for stenosis grading Wilcoxon-matched-pairs testing with multiple comparison correction were calculated. RESULTS: Moderate interreader reliability (ICC = 0.48-0.71) was observed concerning morphological findings on all modalities. Intermodality reliability was good between modalities regarding degenerative vertebral and joint alterations (ICC = 0.69-0.91). Compared to CT neural stenosis grades were more often considered as nonsignificant on all analyzed MR sequences. Neural stenosis grading scores differed also significantly between specific bone imaging sequences, UTE and FRACTURE, to standard MR sequences. However, no significant difference was observed between UTE and FRACTURE sequences. CONCLUSION: Compared to CT as reference, UTE or FRACTURE sequence added to standard MR sequences can deliver comparable information on osseous cervical spine status. Both led to changes in clinically significant stenosis gradings when added to standard MR, mainly reducing the severity of neural foramina stenosis.


Assuntos
Vértebras Cervicais , Imageamento por Ressonância Magnética , Humanos , Constrição Patológica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos
2.
Eur Respir J ; 59(5)2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34649979

RESUMO

BACKGROUND: Radiomic features calculated from routine medical images show great potential for personalised medicine in cancer. Patients with systemic sclerosis (SSc), a rare, multiorgan autoimmune disorder, have a similarly poor prognosis due to interstitial lung disease (ILD). Here, our objectives were to explore computed tomography (CT)-based high-dimensional image analysis ("radiomics") for disease characterisation, risk stratification and relaying information on lung pathophysiology in SSc-ILD. METHODS: We investigated two independent, prospectively followed SSc-ILD cohorts (Zurich, derivation cohort, n=90; Oslo, validation cohort, n=66). For every subject, we defined 1355 robust radiomic features from standard-of-care CT images. We performed unsupervised clustering to identify and characterise imaging-based patient clusters. A clinically applicable prognostic quantitative radiomic risk score (qRISSc) for progression-free survival (PFS) was derived from radiomic profiles using supervised analysis. The biological basis of qRISSc was assessed in a cross-species approach by correlation with lung proteomic, histological and gene expression data derived from mice with bleomycin-induced lung fibrosis. RESULTS: Radiomic profiling identified two clinically and prognostically distinct SSc-ILD patient clusters. To evaluate the clinical applicability, we derived and externally validated a binary, quantitative radiomic risk score (qRISSc) composed of 26 features that accurately predicted PFS and significantly improved upon clinical risk stratification parameters in multivariable Cox regression analyses in the pooled cohorts. A high qRISSc score, which identifies patients at risk for progression, was reverse translatable from human to experimental ILD and correlated with fibrotic pathway activation. CONCLUSIONS: Radiomics-based risk stratification using routine CT images provides complementary phenotypic, clinical and prognostic information significantly impacting clinical decision making in SSc-ILD.


Assuntos
Doenças Pulmonares Intersticiais , Escleroderma Sistêmico , Animais , Humanos , Pulmão/patologia , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Doenças Pulmonares Intersticiais/etiologia , Camundongos , Prognóstico , Proteômica , Escleroderma Sistêmico/complicações , Escleroderma Sistêmico/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
3.
Eur Radiol ; 32(6): 3903-3911, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35020010

RESUMO

OBJECTIVES: To compare the accuracy of lesion detection of trauma-related injuries using combined "all-in-one" fused (AIO) and conventionally reconstructed images (CR) in acute trauma CT. METHODS: In this retrospective study, trauma CT of 66 patients (median age 47 years, range 18-96 years; 20 female (30.3%)) were read using AIO and CR. Images were independently reviewed by 4 blinded radiologists (two residents and two consultants) for trauma-related injuries in 22 regions. Sub-analyses were performed to analyze the influence of experience (residents vs. consultants) and body region (chest, abdomen, skeletal structures) on lesion detection. Paired t-test was used to compare the accuracy of lesion detection. The effect size was calculated (Cohen's d). Linear mixed-effects model with patients as the fixed effect and random forest models were used to investigate the effect of experience, reconstruction/image processing, and body region on lesion detection. RESULTS: Reading time of residents was significantly faster using AIO (AIO: 266 ± 72 s, CR: 318 ± 113 s; p < 0.001; d = 0.46) while no significant difference was observed in the accuracy of lesion detection (AIO: 93.5 ± 6.0%, CR: 94.6 ± 6.0% p = 0.092; d = - 0.21). Reading time of consultants showed no significant difference (AIO: 283 ± 82 s, CR: 274 ± 95 s; p = 0.067; d = 0.16). Accuracy was significantly higher using CR; however, the difference and effect size were very small (AIO 95.1 ± 4.9%, CR: 97.3 ± 3.7%, p = 0.002; d = - 0.39). The linear mixed-effects model showed only minor effect of image processing/reconstruction for lesion detection. CONCLUSIONS: Residents at the emergency department might benefit from faster reading time without sacrificing lesion detection rate using AIO for trauma CT. KEY POINTS: • Image fusion techniques decrease the reading time of acute trauma CT without sacrificing diagnostic accuracy.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Abdome , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Tórax , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
4.
J Magn Reson Imaging ; 51(1): 108-116, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31150142

RESUMO

BACKGROUND: Differentiation of early postoperative complications affects treatment options after lung transplantation. PURPOSE: To assess if texture analysis in ultrashort echo-time (UTE) MRI allows distinction of primary graft dysfunction (PGD) from acute transplant rejection (ATR) in a mouse lung transplant model. STUDY TYPE: Longitudinal. ANIMAL MODEL: Single left lung transplantation was performed in two cohorts of six mice (strain C57BL/6) receiving six syngeneic (strain C57BL/6) and six allogeneic lung transplants (strain BALB/c (H-2Kd )). FIELD STRENGTH/SEQUENCE: 4.7T small-animal MRI/eight different UTE sequences (echo times: 50-5000 µs) at three different postoperative timepoints (1, 3, and 7 days after transplantation). ASSESSMENT: Nineteen different first- and higher-order texture features were computed on multiple axial slices for each combination of UTE and timepoint (24 setups) in each mouse. Texture features were compared for transplanted (graft) and contralateral native lungs between and within syngeneic and allogeneic cohorts. Histopathology served as a reference. STATISTICAL TESTS: Nonparametric tests and correlation matrix analysis were used. RESULTS: Pathology revealed PGD in the syngeneic and ATR in the allogeneic cohort. Skewness and low-gray-level run-length features were significantly different between PGD and ATR for all investigated setups (P < 0.03). These features were significantly different between graft and native lung in ATR for most setups (minimum of 20/24 setups; all P < 0.05). The number of significantly different features between PGD and ATR increased with elapsing postoperative time. Differences in significant features were highest for an echo-time of 1500 µs. DATA CONCLUSION: Our findings suggest that texture analysis in UTE-MRI might be a tool for the differentiation of PGD and ATR in the early postoperative phase after lung transplantation. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2020;51:108-116.


Assuntos
Rejeição de Enxerto/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Transplante de Pulmão , Imageamento por Ressonância Magnética/métodos , Disfunção Primária do Enxerto/diagnóstico por imagem , Doença Aguda , Animais , Diagnóstico Diferencial , Modelos Animais de Doenças , Rejeição de Enxerto/fisiopatologia , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Disfunção Primária do Enxerto/fisiopatologia
5.
Eur Radiol ; 33(10): 6756-6758, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37099177
6.
J Ultrasound Med ; 36(10): 2133-2142, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28626903

RESUMO

This project evaluated a low-cost sponge phantom setup for its capability to teach and study A- and B-line reverberation artifacts known from lung ultrasound and to numerically simulate sound wave interaction with the phantom using a finite-difference time-domain (FDTD) model. Both A- and B-line artifacts were reproducible on B-mode ultrasound imaging as well as in the FDTD-based simulation. The phantom was found to be an easy-to-set up and economical tool for understanding, teaching, and researching A- and B-line artifacts occurring in lung ultrasound. The FDTD method-based simulation was able to reproduce the artifacts and provides intuitive insight into the underlying physics.


Assuntos
Artefatos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Ultrassom/educação , Ultrassonografia/métodos , Animais , Poríferos
7.
AIDS Res Ther ; 10(1): 26, 2013 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-24245779

RESUMO

BACKGROUND: CCR5-delta32 heterozygous individuals are susceptible to HIV-1. However, it is not clear if there is a relevant protective effect against transmission and a beneficial effect in terms of HIV progression which cannot be attributed to CCR5 surface density alone. Therefore we investigated HIV-1 dependency factors (HDF) which might be differently regulated in CCR5 wild type (WT) and CCR5-delta32 heterozygous individuals. METHODS: We examined CD34+ hematopoietic progenitor cells derived from bone marrow samples from 19 healthy volunteers, 12 individuals with CCR5 WT and 7 with heterozygous CCR5-delta32 deletion. Samples were analyzed using a global gene expression oligonucleotide microarray (HG-U133plus 2.0, Affymetrix Inc.). RESULTS: A total of 205 genes were found with altered expression (3fold difference, present call rate of 75%, p < 0.05) and 7 of these had a connection to HIV-1 pathogenesis. In 4 genes: TOP1, CXCR2, SREBF2, and TAP we found a different regulation which was consistent with a supposed beneficial effect for CCR5-delta32 heterozygotes. CONCLUSION: The CCR5-delta32 deletion is associated with other HDFs in HIV-1 pathogenesis as a possible explanation for beneficial effects regarding the deletion leading to a variant expression profile in heterozygous carriers of this mutation.

8.
Diagnostics (Basel) ; 12(1)2022 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-35054268

RESUMO

BACKGROUND: We evaluated the prognostic value of Sarcopenia, low precardial adipose-tissue (PAT), and high tumor-volume in the outcome of surgically-treated pleural mesothelioma (PM). METHODS: From 2005 to 2020, consecutive surgically-treated PM-patients having a pre-operative computed tomography (CT) scan were retrospectively included. Sarcopenia was assessed by CT-based parameters measured at the level of the fifth thoracic vertebra (TH5) by excluding fatty-infiltration based on CT-attenuation. The findings were stratified for gender, and a threshold of the 33rd percentile was set to define sarcopenia. Additionally, tumor volume as well as PAT were measured. The findings were correlated with progression-free survival and long-term mortality. RESULTS: Two-hundred-seventy-eight PM-patients (252 male; 70.2 ± 9 years) were included. The mean progression-free survival was 18.6 ± 12.2 months, and the mean survival time was 23.3 ± 24 months. Progression was associated with chronic obstructive pulmonary disease (COPD) (p = <0.001), tumor-stage (p = 0.001), and type of surgery (p = 0.026). Three-year mortality was associated with higher patient age (p = 0.005), presence of COPD (p < 0.001), higher tumor-stage (p = 0.015), and higher tumor-volume (p < 0.001). Kaplan-Meier statistics showed that sarcopenic patients have a higher three-year mortality (p = 0.002). While there was a negative correlation of progression-free survival and mortality with tumor volume (r = 0.281, p = 0.001 and r = -0.240, p < 0.001; respectively), a correlation with PAT could only be shown for epithelioid PM (p = 0.040). CONCLUSIONS: Sarcopenia as well as tumor volume are associated with long-term mortality in surgically treated PM-patients. Further, while there was a negative correlation of progression-free survival and mortality with tumor volume, a correlation with PAT could only be shown for epithelioid PM.

9.
Br J Radiol ; 95(1133): 20210966, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35195448

RESUMO

OBJECTIVES: Late gadolinium enhancement with fixed short inversion time (LGEshort) provides excellent tissue contrast with dark scar and bright blood pool and does not need prior myocardial nulling. We hypothesize better visibility of ischemic scars and equal visibility of non-ischemic LGE in LGEshort compared to clinically established LGE (LGEstandard). METHODS: LGEshort and LGEstandard were retrospectively evaluated in 179 patients (3043 segments) with suspected or known coronary artery disease by four blinded readers (reader A: most experienced - D: least experienced). The amount of ischemic and non-ischemic LGE as well as visibility (4: very good - 1: poor) of ischemic LGE was visually assessed. RESULTS: All readers detected more infarcted segments in LGEshort compared to LGEstandard (378 segments reported as infarcted; A:p = 0.5, B:p = 0.8, C,D:p = 0.03). Scar visibility was scored higher in LGEshort by all readers (A,B:p = 0.03; C,D:p = 0.02), especially for subendocardial infarcts (A,B:p = 0.04, C,D:p = 0.02). Less experienced readers detected significantly more infarcted papillary muscles (C:p = 0.02, D:p = 0.03) in a shorter reading time in LGEshort (C:p = 0.04, D:p = 0.02). Non-ischemic LGE was equally visible in both sequences (A:p = 0.9, B:p = 0.8, C,D:p = 0.6). CONCLUSIONS: LGEshort detects more ischemic LGE with improved scar visibility compared to LGEstandard, independent of experience level. The visibility of non-ischemic LGE is equivalent to LGEstandard. Less experienced readers can diagnose ischemic and non-ischemic LGE faster in LGEshort. ADVANCES IN KNOWLEDGE: LGEshort with its maximal operational simplicity can be used for visualization of all types of fibrosis - ischemic and non-ischemic - instead of LGEstandard, independent of experience level.


Assuntos
Cardiomiopatias , Gadolínio , Cicatriz/diagnóstico por imagem , Meios de Contraste , Fibrose , Humanos , Aumento da Imagem , Isquemia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Miocárdio/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos
10.
Diagnostics (Basel) ; 12(7)2022 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-35885565

RESUMO

Background: Interstitial lung disease (ILD) is a frequent complication of systemic sclerosis (SSc), and its early detection and treatment may prevent deterioration of lung function. Different vendors have recently made larger image matrices available as a post-processing option for computed tomography (CT), which could facilitate the diagnosis of SSc-ILD. Therefore, the objective of this study was to assess the effect of matrix size on lung image quality in patients with SSc by comparing a 1024-pixel matrix to a standard 512-pixel matrix and applying different reconstruction kernels. Methods: Lung scans of 50 patients (mean age 54 years, range 23−85 years) with SSc were reconstructed with these two different matrix sizes, after determining the most appropriate kernel in a first step. Four observers scored the images on a five-point Likert scale regarding image quality and detectability of clinically relevant findings. Results: Among the eight tested kernels, the Br59-kernel (sharp) reached the highest score (19.48 ± 3.99), although differences did not reach statistical significance. The 1024-pixel matrix scored higher than the 512-pixel matrix HRCT overall (p = 0.01) and in the subcategories sharpness (p < 0.01), depiction of bronchiole (p < 0.01) and overall image impression (p < 0.01), and lower for the detection of ground-glass opacities (GGO) (p = 0.04). No significant differences were found for detection of extent of reticulations/bronchiectasis/fibrosis (p = 0.50) and image noise (p = 0.09). Conclusions: Our results show that with the use of a sharp kernel, the 1024-pixel matrix HRCT, provides a slightly better subjective image quality in terms of assessing interstitial lung changes, whereby GGO are more visible on the 512-pixel matrix. However, it remains to be answered to what extent this is related to the improved representation of the smallest structures.

11.
Front Med (Lausanne) ; 9: 988927, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36465941

RESUMO

Background: Interstitial lung disease (ILD) defines a group of parenchymal lung disorders, characterized by fibrosis as their common final pathophysiological stage. To improve diagnosis and treatment of ILD, there is a need for repetitive non-invasive characterization of lung tissue by quantitative parameters. In this study, we investigated whether CT image patterns found in mice with bleomycin induced lung fibrosis can be translated as prognostic factors to human patients diagnosed with ILD. Methods: Bleomycin was used to induce lung fibrosis in mice (n_control = 36, n_experimental = 55). The patient cohort consisted of 98 systemic sclerosis (SSc) patients (n_ILD = 65). Radiomic features (n_histogram = 17, n_texture = 137) were extracted from microCT (mice) and HRCT (patients) images. Predictive performance of the models was evaluated with the area under the receiver-operating characteristic curve (AUC). First, predictive performance of individual features was examined and compared between murine and patient data sets. Second, multivariate models predicting ILD were trained on murine data and tested on patient data. Additionally, the models were reoptimized on patient data to reduce the influence of the domain shift on the performance scores. Results: Predictive power of individual features in terms of AUC was highly correlated between mice and patients (r = 0.86). A model based only on mean image intensity in the lung scored AUC = 0.921 ± 0.048 in mice and AUC = 0.774 (CI95% 0.677-0.859) in patients. The best radiomic model based on three radiomic features scored AUC = 0.994 ± 0.013 in mice and validated with AUC = 0.832 (CI95% 0.745-0.907) in patients. However, reoptimization of the model weights in the patient cohort allowed to increase the model's performance to AUC = 0.912 ± 0.058. Conclusion: Radiomic signatures of experimental ILD derived from microCT scans translated to HRCT of humans with SSc-ILD. We showed that the experimental model of BLM-induced ILD is a promising system to test radiomic models for later application and validation in human cohorts.

12.
Invest Radiol ; 57(2): 108-114, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34324462

RESUMO

OBJECTIVE: The aim of this study was to evaluate the image quality (IQ) and performance of an artificial intelligence (AI)-based computer-aided detection (CAD) system in photon-counting detector computed tomography (PCD-CT) for pulmonary nodule evaluation at different low-dose levels. MATERIALS AND METHODS: An anthropomorphic chest-phantom containing 14 pulmonary nodules of different sizes (range, 3-12 mm) was imaged on a PCD-CT and on a conventional energy-integrating detector CT (EID-CT). Scans were performed with each of the 3 vendor-specific scanning modes (QuantumPlus [Q+], Quantum [Q], and High Resolution [HR]) at decreasing matched radiation dose levels (volume computed tomography dose index ranging from 1.79 to 0.31 mGy) by adapting IQ levels from 30 to 5. Image noise was measured manually in the chest wall at 8 different locations. Subjective IQ was evaluated by 2 readers in consensus. Nodule detection and volumetry were performed using a commercially available AI-CAD system. RESULTS: Subjective IQ was superior in PCD-CT compared with EID-CT (P < 0.001), and objective image noise was similar in the Q+ and Q-mode (P > 0.05) and superior in the HR-mode (PCD 55.8 ± 11.7 HU vs EID 74.8 ± 5.4 HU; P = 0.01). High resolution showed the lowest image noise values among PCD modes (P = 0.01). Overall, the AI-CAD system delivered comparable results for lung nodule detection and volumetry between PCD- and dose-matched EID-CT (P = 0.08-1.00), with a mean sensitivity of 95% for PCD-CT and of 86% for dose-matched EID-CT in the lowest evaluated dose level (IQ5). Q+ and Q-mode showed higher false-positive rates than EID-CT at lower-dose levels (IQ10 and IQ5). The HR-mode showed a sensitivity of 100% with a false-positive rate of 1 even at the lowest evaluated dose level (IQ5; CDTIvol, 0.41 mGy). CONCLUSIONS: Photon-counting detector CT was superior to dose-matched EID-CT in subjective IQ while showing comparable to lower objective image noise. Fully automatized AI-aided nodule detection and volumetry are feasible in PCD-CT, but attention has to be paid to false-positive findings.


Assuntos
Inteligência Artificial , Fótons , Computadores , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos
13.
Diagnostics (Basel) ; 11(5)2021 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-34066913

RESUMO

Lung nodules are frequent findings in chest computed tomography (CT) in patients with metastatic melanoma. In this study, we assessed the frequency and compared morphologic differences of metastases and benign nodules. We retrospectively evaluated 85 patients with melanoma (AJCC stage III or IV). Inclusion criteria were ≤20 lung nodules and follow-up using CT ≥183 days after baseline. Lung nodules were evaluated for size and morphology. Nodules with significant growth, nodule regression in line with RECIST assessment or histologic confirmation were judged to be metastases. A total of 438 lung nodules were evaluated, of which 68% were metastases. At least one metastasis was found in 78% of patients. A 10 mm diameter cut-off (used for RECIST) showed a specificity of 95% and a sensitivity of 20% for diagnosing metastases. Central location (n = 122) was more common in metastatic nodules (p = 0.009). Subsolid morphology (n = 53) was more frequent (p < 0.001), and calcifications (n = 13) were solely found in non-metastatic lung nodules (p < 0.001). Our data show that lung nodules are prevalent in about two-thirds of melanoma patients (AJCC stage III/IV) and the majority are metastases. Even though we found a few morphologic indicators for metastatic or non-metastatic lung nodules, morphology has limited value to predict the presence of lung metastases.

14.
PLoS One ; 16(12): e0261401, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34928978

RESUMO

OBJECTIVES: To evaluate CT-derived radiomics for machine learning-based classification of thymic epithelial tumor (TET) stage (TNM classification), histology (WHO classification) and the presence of myasthenia gravis (MG). METHODS: Patients with histologically confirmed TET in the years 2000-2018 were retrospectively included, excluding patients with incompatible imaging or other tumors. CT scans were reformatted uniformly, gray values were normalized and discretized. Tumors were segmented manually; 15 scans were re-segmented after 2 weeks by two readers. 1316 radiomic features were calculated (pyRadiomics). Features with low intra-/inter-reader agreement (ICC<0.75) were excluded. Repeated nested cross-validation was used for feature selection (Boruta algorithm), model training, and evaluation (out-of-fold predictions). Shapley additive explanation (SHAP) values were calculated to assess feature importance. RESULTS: 105 patients undergoing surgery for TET were identified. After applying exclusion criteria, 62 patients (28 female; mean age, 57±14 years; range, 22-82 years) with 34 low-risk TET (LRT; WHO types A/AB/B1), 28 high-risk TET (HRT; WHO B2/B3/C) in early stage (49, TNM stage I-II) or advanced stage (13, TNM III-IV) were included. 14(23%) of the patients had MG. 334(25%) features were excluded after intra-/inter-reader analysis. Discriminatory performance of the random forest classifiers was good for histology(AUC, 87.6%; 95% confidence interval, 76.3-94.3) and TNM stage(AUC, 83.8%; 95%CI, 66.9-93.4) but poor for the prediction of MG (AUC, 63.9%; 95%CI, 44.8-79.5). CONCLUSIONS: CT-derived radiomic features may be a useful imaging biomarker for TET histology and TNM stage.


Assuntos
Algoritmos , Técnicas Histológicas/métodos , Aprendizado de Máquina , Miastenia Gravis/fisiopatologia , Neoplasias Epiteliais e Glandulares/patologia , Neoplasias do Timo/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miastenia Gravis/diagnóstico por imagem , Estadiamento de Neoplasias , Neoplasias Epiteliais e Glandulares/diagnóstico por imagem , Neoplasias Epiteliais e Glandulares/cirurgia , Estudos Retrospectivos , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/cirurgia , Adulto Jovem
15.
Acad Radiol ; 27(4): 508-517, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31358357

RESUMO

OBJECTIVES: To assess the effect of vertical off-centering in tube current modulation (TCM) on effective-dose and image-noise in reduced-dose (RD) chest-CT. METHODS: One-hundred consecutive patients (36 female; mean age 56 years) were scanned on a 192-slice CT scanner with a standard-dose (ND) and a RD chest-CT protocol using tube current modulation. Image-noise was evaluated by placing circular regions of interest in the apical, middle, and lower lung regions. Two independent readers evaluated image quality. Study population was stratified according to patient position in the gantry: positioned in the gantry isocenter (i), higher than the gantry isocenter (ii), and lower than the gantry isocenter, (iii). Pearson correlation was used to determine the correlation between effective radiation dose and vertical off-centering. Student's t test was used to evaluate for differences in image-noise between groups (i-iii). RESULTS: Mean vertical off-centering was of 10.6 mm below the gantry-isocenter (range -45.0-27.9 mm). Effective radiation dose varied in a linear trend, with the highest doses noted below gantry isocenter, and the lowest doses noted above gantry isocenter (ND: r = -0.296; p = 0.003 - RD: r = -0.258; p = 0.010). Lowest image-noise was observed where patients were positioned below the gantry isocenter, and highest in patients positioned above (ND: 79.35 HU vs. 94.86 HU - RD: 143.44 HU vs. 160.13 HU). Subjective image quality was not significantly affected by patient-position (p > 0.05). Overall, there was no over-proportional noise-increase from the ND to the RD protocol in patients which were positioned off-center. CONCLUSION: Vertical off-centering influences effective radiation dose and image-noise on ND and RD protocols. ADVANCES IN KNOWLEDGE: There is no over-proportional noise increase in RD compared to ND protocols when patients are positioned off-center.


Assuntos
Posicionamento do Paciente , Tórax , Tomografia Computadorizada por Raios X , Feminino , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Tórax/diagnóstico por imagem , Tomógrafos Computadorizados
16.
PLoS One ; 15(10): e0239975, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33017413

RESUMO

PURPOSE: To assess the value of the PI-RADS 2.1 scoring system in the detection of prostate cancer on multiparametric MRI in comparison to the standard PI-RADS 2.0 system and to assess its inter-reader variability. MATERIALS AND METHODS: This IRB-approved study included 229 patients undergoing multiparametric prostate MRI prior to MRI-guided TRUS-based biopsy, which were retrospectively recruited from our prospectively maintained institutional database. Two readers with high (reader 1, 6 years) and low (reader 2, 2 years) level of expertise identified the lesion with the highest PI-RADS score for both version 2.0 and 2.1 for each patient. Inter-reader agreement was estimated, and diagnostic accuracy analysis was performed. RESULTS: Inter-reader agreement on PI-RADS scores was fair for both version 2.0 (kappa: 0.57) and 2.1 (kappa: 0.51). Detection rates for prostate cancer (PCa) and clinically significant prostate cancer (csPCa) were almost identical for both PI-RADS versions and higher for the more experienced reader (AUC, Reader 1: PCa, 0.881-0.887, csPCa, 0.874-0.879; Reader 2: PCa, 0.765, csPCa, 0.746-0.747; both p > 0.05), both when using a PI-RADS score of ≥ 4 and ≥3 as indicators for positivity for cancer. CONCLUSIONS: The new PI-RADS 2.1 scoring system showed comparable diagnostic performance and inter-reader variability compared to version 2.0. The introduced changes in the version 2.1 seem only to take effect in a very small number of patients.


Assuntos
Próstata/patologia , Neoplasias da Próstata/diagnóstico , Área Sob a Curva , Bases de Dados Factuais , Humanos , Interpretação de Imagem Assistida por Computador , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Masculino , Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Curva ROC , Estudos Retrospectivos
17.
PLoS One ; 15(10): e0240078, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33017451

RESUMO

BACKGROUND: To evaluate chest-computed-tomography (CT) scans in coronavirus-disease-2019 (COVID-19) patients for signs of organizing pneumonia (OP) and microinfarction as surrogate for microscopic thromboembolic events. METHODS: Real-time polymerase-chain-reaction (RT-PCR)-confirmed COVID-19 patients undergoing chest-CT (non-enhanced, enhanced, pulmonary-angiography [CT-PA]) from March-April 2020 were retrospectively included (COVID-19-cohort). As control-groups served 175 patients from 2020 (cohort-2020) and 157 patients from 2019 (cohort-2019) undergoing CT-PA for pulmonary embolism (PE) during the respective time frame at our institution. Two independent readers assessed for presence and location of PE in all three cohorts. In COVID-19 patients additionally parenchymal changes typical of COVID-19 pneumonia, infarct pneumonia and OP were assessed. Inter-reader agreement and prevalence of PE in different cohorts were calculated. RESULTS: From 68 COVID-19 patients (42 female [61.8%], median age 59 years [range 32-89]) undergoing chest-CT 38 obtained CT-PA. Inter-reader-agreement was good (k = 0.781). On CT-PA, 13.2% of COVID-19 patients presented with PE whereas in the control-groups prevalence of PE was 9.1% and 8.9%, respectively (p = 0.452). Up to 50% of COVID-19 patients showed changes typical for OP. 21.1% of COVID-19 patients suspected with PE showed subpleural wedge-shaped consolidation resembling infarct pneumonia, while only 13.2% showed visible filling defects of the pulmonary artery branches on CT-PA. CONCLUSION: Despite the reported hypercoagulability in critically ill patients with COVID-19, we did not encounter higher prevalence of PE in our patient cohort compared to the control cohorts. However, patients with suspected PE showed a higher prevalence of lung changes, resembling patterns of infarct pneumonia or OP and CT-signs of pulmonary-artery hypertension.


Assuntos
Infecções por Coronavirus/patologia , Pneumonia Viral/patologia , Artéria Pulmonar/patologia , Infarto Pulmonar/diagnóstico por imagem , Tromboembolia/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19 , Infecções por Coronavirus/diagnóstico por imagem , Feminino , Humanos , Pulmão/irrigação sanguínea , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
18.
J Clin Med ; 9(11)2020 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-33171999

RESUMO

PURPOSE: To evaluate diagnostic accuracy of conventional radiography (CXR) and machine learning enhanced CXR (mlCXR) for the detection and quantification of disease-extent in COVID-19 patients compared to chest-CT. METHODS: Real-time polymerase chain reaction (rt-PCR)-confirmed COVID-19-patients undergoing CXR from March to April 2020 together with COVID-19 negative patients as control group were retrospectively included. Two independent readers assessed CXR and mlCXR images for presence, disease extent and type (consolidation vs. ground-glass opacities (GGOs) of COVID-19-pneumonia. Further, readers had to assign confidence levels to their diagnosis. CT obtained ≤ 36 h from acquisition of CXR served as standard of reference. Inter-reader agreement, sensitivity for detection and disease extent of COVID-19-pneumonia compared to CT was calculated. McNemar test was used to test for significant differences. RESULTS: Sixty patients (21 females; median age 61 years, range 38-81 years) were included. Inter-reader agreement improved from good to excellent when mlCXR instead of CXR was used (k = 0.831 vs. k = 0.742). Sensitivity for pneumonia detection improved from 79.5% to 92.3%, however, on the cost of specificity 100% vs. 71.4% (p = 0.031). Overall, sensitivity for the detection of consolidation was higher than for GGO (37.5% vs. 70.4%; respectively). No differences could be found in disease extent estimation between mlCXR and CXR, even though the detection of GGO could be improved. Diagnostic confidence was better on mlCXR compared to CXR (p = 0.013). CONCLUSION: In line with the current literature, the sensitivity for detection and quantification of COVID-19-pneumonia was moderate with CXR and could be improved when mlCXR was used for image interpretation.

19.
Eur J Radiol Open ; 7: 100272, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33043101

RESUMO

RATIONALE AND OBJECTIVES: To demonstrate the first experience of a deep learning-based algorithm for automatic quantification of lung parenchymal abnormalities in chest CT of COVID-19 patients and to correlate quantitative results with clinical and laboratory parameters. MATERIALS AND METHODS: We retrospectively included 60 consecutive patients (mean age, 61 ± 12 years; 18 females) with proven COVID-19 infection undergoing chest CT between March and May 2020. Clinical and laboratory data (within 24 h before/after chest CT) were recorded. Prototype software using a deep learning algorithm was applied for automatic segmentation and quantification of lung opacities. Percentage of opacity (PO, ground-glass and consolidations) and percentage of high opacity (PHO, consolidations), were defined as 100 times the volume of segmented abnormalities divided by the volume of the lung mask. RESULTS: Automatic CT analysis of the lung was feasible in all patients (n = 60). The median time to accomplish automatic evaluation was 120 s (IQR: 118-128 s). In four cases (7 %), manual corrections were necessary. Patients with need for mechanical ventilation had a significantly higher PO (median 44 %, IQR: 23-58 % versus 13 %, IQR: 10-24 %; p = 0.001) and PHO (median: 11 %, IQR: 6-21 % versus 3%, IQR: 2-7 %, p = 0.002) compared to those without. The PO and PHO moderately correlated with c-reactive protein (r = 0.49-0.60, both p < 0.001) and leucocyte count (r = 0.30-0.40, both p = 0.05). PO had a negative correlation with SO2 (r=-0.50, p = 0.001). CONCLUSION: Preliminary experience indicates the feasibility of a rapid, automatic quantification tool of lung parenchymal abnormalities in COVID-19 patients using deep learning, with results correlating with laboratory and clinical parameters.

20.
Eur J Radiol ; 126: 108925, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32193036

RESUMO

PURPOSE: To evaluate a deep learning based image analysis software for the detection and localization of distal radius fractures. METHOD: A deep learning system (DLS) was trained on 524 wrist radiographs (166 showing fractures). Performance was tested on internal (100 radiographs, 42 showing fractures) and external test sets (200 radiographs, 100 showing fractures). Single and combined views of the radiographs were shown to DLS and three readers. Readers were asked to indicate fracture location with regions of interest (ROI). The DLS yielded scores (range 0-1) and a heatmap. Detection performance was expressed as AUC, sensitivity and specificity at the optimal threshold and compared to radiologists' performance. Heatmaps were compared to radiologists' ROIs. RESULTS: The DLS showed excellent performance on the internal test set (AUC 0.93 (95% confidence interval (CI) 0.82-0.98) - 0.96 (0.87-1.00), sensitivity 0.81 (0.58-0.95) - 0.90 (0.70-0.99), specificity 0.86 (0.68-0.96) - 1.0 (0.88-1.0)). DLS performance decreased on the external test set (AUC 0.80 (0.71-0.88) - 0.89 (0.81-0.94), sensitivity 0.64 (0.49-0.77) - 0.92 (0.81-0.98), specificity 0.60 (0.45-0.74) - 0.90 (0.78-0.97)). Radiologists' performance was comparable on internal data (sensitivity 0.71 (0.48-0.89) - 0.95 (0.76-1.0), specificity 0.52 (0.32-0.71) - 0.97 (0.82-1.0)) and better on external data (sensitivity 0.88 (0.76-0.96) - 0.98 (0.89-1.0), specificities 0.66 (0.51-0.79) - 1.0 (0.93-1.0), p < 0.05). In over 90%, the areas of peak activation aligned with radiologists' annotations. CONCLUSIONS: The DLS was able to detect and localize wrist fractures with a performance comparable to radiologists, using only a small dataset for training.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Fraturas do Rádio/diagnóstico por imagem , Estudos de Coortes , Aprendizado Profundo , Feminino , Humanos , Radiologistas , Rádio (Anatomia)/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA