Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Europace ; 14(2): 230-7, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21933802

RESUMO

AIMS: Uncertainty exists over the importance of device-detected short-duration atrial arrhythmias. Continuous atrial diagnostics, through home monitoring (HM) technology (BIOTRONIK, Berlin, Germany), provides a unique opportunity to assess frequency and quantity of atrial fibrillation (AF) episodes defined as atrial high-rate events (AHRE). METHODS AND RESULTS: Prospective data from 560 heart failure (HF) patients (age 67 ± 10 years, median ejection fraction 27%) patients with a cardiac resynchronization therapy (CRT) device capable of HM from two multi-centre studies were analysed. Atrial high-rate events burden was defined as the duration of mode switch in a 24-h period with atrial rates of >180 beats for at least 1% or total of 14 min per day. The primary endpoint was incidence of a thromboembolic (TE) event. Secondary endpoints were cardiovascular death, hospitalization because of AF, or worsening HF. Over a median 370-day follow-up AHRE occurred in 40% of patients with 11 (2%) patients developing TE complications and mortality rate of 4.3% (24 deaths, 16 with cardiovascular aetiology). Compared with patients without detected AHRE, patients with detected AHRE>3.8 h over a day were nine times more likely to develop TE complications (P= 0.006). The majority of patients (73%) did not show a temporal association with the detected atrial episode and their adverse event, with a mean interval of 46.7 ± 71.9 days (range 0-194) before the TE complication. CONCLUSION: In a high-risk cohort of HF patients, device-detected atrial arrhythmias are associated with an increased incidence of TE events. A cut-off point of 3.8 h over 24 h was associated with significant increase in the event rate. Routine assessment of AHRE should be considered with other data when assessing stroke risk and considering anti-coagulation initiation and should also prompt the optimization of cardioprotective HF therapy in CRT patients.


Assuntos
Fibrilação Atrial/dietoterapia , Fibrilação Atrial/mortalidade , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Serviços de Assistência Domiciliar/estatística & dados numéricos , Idoso , Fibrilação Atrial/prevenção & controle , Terapia de Ressincronização Cardíaca , Estudos de Coortes , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Internacionalidade , Masculino , Prevalência , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Análise de Sobrevida , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA