RESUMO
BACKGROUND: Hemoglobin C, D Punjab, E or S trait can interfere with hemoglobin A1c (HbA1c) results. We assessed whether they affect results obtained with 15 current assay methods. METHODS: Hemoglobin AA (HbAA), HbAC, HbAD Punjab, HbAE and HbAS samples were analyzed on 2 enzymatic, 4 ion-exchange HPLC and 9 immunoassay methods. Trinity Premier Hb9210 boronate affinity HPLC was the comparative method. An overall test of coincidence of least-squared linear regression lines was performed to determine if HbA1c results were statistically significantly different from those of HbAA samples. Clinically significant interference was defined as >6% difference from HbAA at 6 or 9% HbA1c compared to Premier Hb9210 using Deming regression. RESULTS: All methods showed statistically significant effects for one or more variants. Clinically significant effects were observed for the Tosoh G11 variant mode (HbAD), Roche b 101 (HbAC and HbAE) and Siemens DCA Vantage (HbAE and HbAS). All other methods (Beckman Coulter B93009 and B00389 on DxC700AU, and Unicel DxC, Ortho Clinical Vitros 5.1, Roche cobas c 513, Siemens Dimension RxL and Vista, and Enzymatic on Advia and Atellica, Tosoh G8 5.24 and 5.28, and GX) showed no clinically significant differences. CONCLUSIONS: A few methods showed interference from one or more variants. Laboratories need to be aware of potential HbA1c assay interferences.
Assuntos
Testes Hematológicos , Hemoglobina C , Cromatografia Líquida de Alta Pressão , Hemoglobinas Glicadas/análise , Humanos , ImunoensaioRESUMO
OBJECTIVES: To report the finding of a novel double heterozygous hemoglobinopathy, the coinheritance of Hb Fontainebleau (α-chain variant) with HbD-Punjab (ß-chain variant) discovered upon investigation of unexplained microcytosis in an infant. DESIGN AND METHODS: Hemoglobinopathy investigation was performed by high performance liquid chromatography (HPLC) using the ß-thalassemia Short Program on the Bio-Rad Variant II(TM) followed by gel electrophoresis at alkaline and acid pH (Sebia Hydrasys 2 Electrophoresis System) and molecular diagnostic testing. This study complied with our institutional board ethics requirements. RESULTS: HPLC and electrophoresis suggested a complex α- and ß-chain hemoglobinopathy with presumptive identification of the beta Hb variant as Hb D-Punjab. DNA sequencing analysis revealed the presence of a double heterozygous status for Hb Fontainebleau/Hb D-Punjab. CONCLUSIONS: In this paper we report the coinheritance of Hb Fontainebleau with Hb D-Punjab.