Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 35(1): 81-7, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22077194

RESUMO

BACKGROUND: Infection following cardiovascular implantable electronic device (CIED) replacement is a serious complication, and rates of infection have increased. Analysis of procedural and clinical data from device replacement procedures collected by the REPLACE Registry may provide insights into infection prevention strategies and outcomes. METHODS: We prospectively evaluated procedural complications in patients undergoing CIED replacement over 6 months from 72 U.S. sites. Major and minor infections were predefined and adjudicated by an independent blinded clinical events committee. Data regarding infection prevention strategies and infectious outcomes were analyzed for their potential relationships. RESULTS: A total of 1,744 patients were included in REPLACE. All patients received preoperative intravenous antibiotics and 68.7% received postoperative systemic antibiotic therapy. CIED infection developed in 22 patients (1.3%), of which 14 cases were major (0.8%, 95% confidence interval [CI] 0.4%-1.3%) and eight were minor (0.5%, 95% CI 0.2%-0.9%). Patients with infections were more likely to have had postoperative hematomas (five of 22 [22.7%] vs 17 of 1,722 [0.98%], P = 0.002). Participating sites experiencing infection rates >5% were more likely to use povidone-iodine for topical antisepsis, had lower implantation volume, and had patients with higher Charlson Comorbidity Index (2.79 vs 2.32, 95% CI for difference 0.08-0.86, P = 0.019). CONCLUSIONS: In this multicenter prospective study with 6 months of follow-up, infections associated with CIED replacements were surprisingly infrequent, possibly due to the use of preoperative antibiotics. Patients with infections were more likely to have had a postoperative hematoma, and sites with higher infection rates had sicker patients and lower overall procedural volume.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Miocardite/epidemiologia , Miocardite/prevenção & controle , Marca-Passo Artificial/estatística & dados numéricos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Idoso , Feminino , Humanos , Masculino , Prevalência , Medição de Risco , Estados Unidos/epidemiologia
2.
Circulation ; 122(16): 1553-61, 2010 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-20921437

RESUMO

BACKGROUND: Prospective studies defining the risk associated with pacemaker or implantable cardioverter-defibrillator replacement surgeries do not exist. These procedures are generally considered low risk despite results from recent retrospective series reporting higher rates. METHODS AND RESULTS: We prospectively assessed predefined procedure-related complication rates associated with elective pacemaker or implantable cardioverter-defibrillator generator replacements over 6 months of follow-up. Two groups were studied: those without (cohort 1) and those with (cohort 2) a planned transvenous lead addition for replacement or upgrade to a device capable of additional therapies. Complications were adjudicated by an independent events committee. Seventy-two US academic and private practice centers participated. Major complications occurred in 4.0% (95% confidence interval, 2.9 to 5.4) of 1031 cohort 1 patients and 15.3% (95% confidence interval, 12.7 to 18.1) of 713 cohort 2 patients. In both cohorts, major complications were higher with implantable cardioverter-defibrillator compared with pacemaker generator replacements. Complications were highest in patients who had an upgrade to or a revised cardiac resynchronization therapy device (18.7%; 95% confidence interval, 15.1 to 22.6). No periprocedural deaths occurred in either cohort, although 8 later procedure-related deaths occurred in cohort 2. The 6-month infection rates were 1.4% (95% confidence interval, 0.7 to 2.3) and 1.1% (95% confidence interval, 0.5 to 2.2) for cohorts 1 and 2, respectively. CONCLUSIONS: Pacemaker and implantable cardioverter-defibrillator generator replacements are associated with a notable complication risk, particularly those with lead additions. These data support careful decision making before device replacement, when managing device advisories, and when considering upgrades to more complex systems.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos , Estudos de Coortes , Falha de Equipamento , Feminino , Seguimentos , Parada Cardíaca/epidemiologia , Hematoma/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Trombose Venosa/epidemiologia
SELEÇÃO DE REFERÊNCIAS