1.
J Orthop Traumatol ; 19(1): 14, 2018 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-30120638

RESUMO

BACKGROUND: The purpose of this study was to examine the gait pattern of total hip arthroplasty (THA) patients with a new short femoral stem at different speeds and inclinations. MATERIALS AND METHODS: A total of 40 unilateral THA patients were tested on an instrumented treadmill. They comprised two groups (shorter stemmed THA n = 20, longer stemmed THA n = 20), both which had the same surgical posterior approach. The shorter femoral stemmed patients were taken from an ongoing hip trial with minimum 12 months postop. The comparative longer THR group with similar disease and severity were taken from a gait database along with a demographically similar group of healthy controls (n = 35). All subjects were tested through their entire range of gait speeds and inclines with ground reaction forces collected. Body weight scaling was applied and a symmetry index to compare the implanted hip to the contralateral normal hip. An analysis of variance with significance set at α = 0.05 was used. RESULTS: The experimental groups were matched demographically and implant groups for patient reported outcome measures and radiological disease. Both THA groups walked slower than controls, but symmetry at all intervals for all groups were not significantly different. Push-off loading was less favourable for both the shorter and longer stemmed THR groups (p < 0.05) depending on speed. CONCLUSIONS: Irrespective of femoral stem length, symmetry for ground reaction forces for both THA groups were returned to a normal range when compared to controls. However individual implant performance showed inferior (p < 0.05) push-off forces and normalised step length in both THR groups when compared to controls. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Marcha/fisiologia , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Velocidade de Caminhada/fisiologia , Suporte de Carga/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Teste de Esforço , Feminino , Fêmur/diagnóstico por imagem , Análise da Marcha , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico , Osteoartrite do Quadril/fisiopatologia , Período Pós-Operatório , Radiografia
2.
Clin Rev Bone Miner Metab ; 14(3): 150-160, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27683260

RESUMO

Bone is a complex hierarchical structure, and its principal function is to resist mechanical forces and fracture. Bone strength depends not only on the quantity of bone tissue but also on the shape and hierarchical structure. The hierarchical levels are interrelated, especially the micro-architecture, collagen and mineral components; hence, analysis of their specific roles in bone strength and stiffness is difficult. Synchrotron imaging technologies including micro-CT and small/wide angle X-ray scattering/diffraction are becoming increasingly popular for studying bone because the images can resolve deformations in the micro-architecture and collagen-mineral matrix under in situ mechanical loading. Synchrotron cannot be directly applied in vivo due to the high radiation dose but will allow researchers to carry out systematic multifaceted studies of bone ex vivo. Identifying characteristics of aging and disease will underpin future efforts to generate novel devices and interventional therapies for assessing and promoting healthy aging. With our own research work as examples, this paper introduces how synchrotron imaging technology can be used with in situ testing in bone research.

3.
Ann Plast Surg ; 75(2): 208-12, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24691342

RESUMO

INTRODUCTION: Plastic surgery teaching has a limited role in the undergraduate curriculum. We held a 1-day national course in plastic surgery for undergraduates. Our aim was to introduce delegates to plastic surgery and teach basic plastic surgical skills. We assessed change in perceptions of plastic surgery and change in confidence in basic plastic surgical skills. METHOD: The day consisted of consultant-led lectures followed by workshops in aesthetic suturing, local flap design, and tendon repair. A questionnaire divided into 3 sections, namely, (1) career plans, (2) perceptions of plastic surgery, and (3) surgical skills and knowledge, was completed by 39 delegates before and after the course. Results were presented as mean scores and the standard error of the mean used to calculate data spread. Data were analyzed using the Mann-Whitney U test for nonparametric data. RESULTS: Career plans: Interest in pursuing a plastic surgery career significantly increased over the course of the day by 12.5% (P < 0.0005).Perceptions: Statistically significant changes were observed in many categories of plastic surgery, including the perception of the role of plastic surgeons in improving patient quality of life, increased by 18.31% (P = 0.063). Before the course 10% of delegates perceived plastic surgery to be a superficial discipline and 20% perceived that plastic surgeons did not save lives. After completing the course, no delegates held those views.Surgical skills: Confidence to perform subcuticular and deep dermal sutures improved by 53% (P < 0.0001) and 57% (P < 0.0001), respectively. Delegates' subjective understanding of the basic geometry of local flaps improved by 94% (P < 0.0001). Interestingly, before the course, 2.5% of delegates drew an accurate modified Kessler suture compared with 87% of on completion of the course. CONCLUSIONS: A 1-day intensive undergraduate plastic surgery course can significantly increase delegates' desire to pursue a career in plastic surgery, dispel common misconceptions about this field, and increase their confidence in performing the taught skills. The results of this course demonstrate that a 1-day course is an effective means of teaching basic plastic surgery skills to undergraduates and highlights the potential role for local plastic surgery departments in advancing plastic surgery education.


Assuntos
Escolha da Profissão , Competência Clínica , Educação de Graduação em Medicina/métodos , Estudantes de Medicina/psicologia , Cirurgia Plástica/educação , Feminino , Humanos , Londres , Masculino , Avaliação de Programas e Projetos de Saúde , Procedimentos de Cirurgia Plástica/educação , Inquéritos e Questionários
4.
SICOT J ; 10: 25, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38847649

RESUMO

BACKGROUND: Joint-preserving hip operations can help relieve pain and delay the need for long-term joint arthroplasty. Previous research has not identified procedures that can compromise outcomes following total hip arthroplasty (THA). This meta-analysis aims to evaluate the effect of joint-preserving hip operations on outcomes following subsequent THA. METHODS: MEDLINE, EMBASE and Scopus databases were searched from the date of inception until February 2024. All studies comparing outcomes following THA in individuals with (PS) and without prior surgery (NPS) of the femur or pelvis were included. Data on operative time, blood loss, intra- and post-operative complications, functional outcomes, and implant survivorship were extracted. RESULTS: 16 studies, comprising 2576 patients were included (PS = 939, NPS = 1637). The PS group was associated with significantly longer operative time [MD: 8.1, 95% CI: 4.6-11.6], significantly greater blood loss [MD: 167.8, 95% CI: 135.6-200.0], and a higher risk of intra-operative peri-prosthetic fracture [RR: 1.9, 95% CI: 1.2-3.0], specifically, with prior femoral osteotomy. There were no differences in terms of risks of dislocation [RR: 1.8, 95% CI: 1.0-3.2], implant loosening [RR: 1.0, 95% CI: 0.7-1.5], or revision surgery [RR: 1.3, 95% CI: 1.0-1.7] between the two groups. The PS group was associated with significantly poorer improvements in functional outcome [MD: -5.6, 95% CI: -7.6-(-3.5)], specifically, with prior acetabular osteotomy. Implant survivorship in the two groups was comparable after one year [HR: 1.9, 95% CI: 0.6-6.2] but significantly inferior in the PS group after five years [HR: 2.5, 95% CI: 1.4-4.7], specifically, with prior femoral osteotomy. CONCLUSION: Joint-preserving hip operations are associated with greater intra-operative challenges and complications. In subsequent joint arthroplasty, prior acetabular procedures affect functional outcomes while prior femoral procedures influence implant survivorship. Hip pain due to the morphological sequelae of pediatric hip pathology can be debilitating at a young age. Surgical decision-making at that time needs to consider the survivorship of a THA implanted at that young age against the consequences of hip preservation surgery on further THA.

5.
Bone Joint Res ; 13(4): 193-200, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38649151

RESUMO

Aims: Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies. Methods: Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment. Results: The force vector of the mallet strike, relative to the introducer axis, was misaligned by an average of 18.1°, resulting in an average wasted strike energy of 6.1%. Furthermore, the mean strike offset was 19.8 mm from the centre of the introducer axis and the mallet face, relative to the introducer strike face, was misaligned by a mean angle of 15.2° from the introducer strike face. Conclusion: The direction of the impact vector in manual impaction lacks both accuracy and precision. There is an opportunity to improve this through more advanced impaction instruments or surgical training.

6.
Br J Clin Pharmacol ; 76(3): 425-31, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23305195

RESUMO

AIMS: An algorithm based on the CYP3A5 genotype to predict tacrolimus clearance to inform the optimal initial dose was derived using data from the DeKAF study (Passey et al. Br J Clin Pharmacol 2011; 72: 948-57) but was not tested in an independent cohort of patients. Our aim was to test whether the DeKAF dosing algorithm could predict estimated tacrolimus clearance in renal transplant recipients at our centre. METHODS: Predicted tacrolimus clearance based on the DeKAF algorithm was compared with dose-normalized trough whole-blood concentrations (estimated clearance) on day 7 after transplantation in a single-centre cohort of 255 renal transplant recipients. RESULTS: There was a weak correlation (r = 0.431) between clearance based on dose-normalized trough whole-blood concentrations and DeKAF algorithm-predicted clearance. The means of the tacrolimus clearance predicted by the DeKAF algorithm and the estimated tacrolimus clearance based on the dose-normalized trough blood concentrations were plotted against the differences in the clearance as a Bland-Altman plot. Logarithmic transformation was performed owing to the increased difference in tacrolimus clearance as the mean clearance increased. There was a highly significant systematic error (P < 0.0005) characterized by a sloped regression line [gradient, 0.88 (95% confidence interval, 0.75-1.01)] on the Bland-Altman plot. CONCLUSIONS: The DeKAF algorithm was unable to predict the estimated tacrolimus clearance accurately based on real tacrolimus doses and blood concentrations in our cohort of patients. Other genes are known to influence the clearance of tacrolimus, and a polygenic algorithm may be more predictive than those based on a single genotype.


Assuntos
Algoritmos , Citocromo P-450 CYP3A/genética , Imunossupressores/farmacocinética , Transplante de Rim , Tacrolimo/farmacocinética , Adolescente , Adulto , Idoso , Estudos de Coortes , Relação Dose-Resposta a Droga , Feminino , Genótipo , Humanos , Imunossupressores/sangue , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Farmacogenética , Valor Preditivo dos Testes , Tacrolimo/sangue , Adulto Jovem
7.
SICOT J ; 9: 25, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37560993

RESUMO

INTRODUCTION: Developmental dysplasia of the hip (DDH) refers to congenital and/or developmental hip instability that can result in hip joint subluxation or dislocation. When detected neonatally, conservative treatment with hip bracing can restore normal hip anatomy. Missed detection of DDH in the neonatal period or late development of DDH often requires surgical intervention to correct the abnormal anatomy. Furthermore, despite surgical intervention, residual sequelae may persist leading to early osteoarthritis of the hip joint requiring joint replacement surgery. AIM: This study investigates the prevalence of hip dysplasia in patients undergoing total hip arthroplasty (THA) under 50 years of age. METHODS: The hip arthroplasty database at a national referral centre was investigated from January 2014 to December 2020. In patients under 50 years of age, those with an adequate pre-operative anteroposterior pelvic radiograph without previous hip arthroplasty were included, while those with inadequate radiographs were excluded. The following measurements were made on the contralateral non-operated hip: (1) lateral centre-edge angle (LCEA), (2) Tönnis angle, (3) acetabular version, (4) acetabular depth, (5) femoral head lateralisation, (6) femoral head extrusion index, and (7) acetabular depth-to-width ratio. RESULTS: In total, 451 patients were included in this study. Twenty two percent of the patients had hip dysplasia, based on a LCEA of <25° and 42.6% of patients had hip dysplasia, based on a Tönnis angle of > 10°. The mean LCEA and Tönnis angle were 31.47 ± 9.64 and 9.82 ± 6.79°, respectively. CONCLUSION: Hip dysplasia is common in patients undergoing THA under the age of 50 years with over 40% having dysplasia according to the Tönnis angle. Classification of primary and secondary osteoarthritis in the joint registries will benefit our knowledge on the prevalence of DDH in the adult population.

8.
J Orthop Surg Res ; 18(1): 583, 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37553588

RESUMO

INTRODUCTION: Successful press-fit implantation relies on an accurately reamed bone cavity. Inaccurate reaming can lead to a suboptimal press-fit risking fracture and cup deformation or excessive micromotion and loosening. Several factors may impact reaming accuracy including the reamer design, the surgeon's technique and the bone quality. The aim of this study is to investigate the accuracy of reaming techniques and the accuracy of a novel reamer design. METHODS: Eighty composite bone models, half high density and half low density, were reamed with either a conventional or an additively manufactured reamer with a novel design employing either a straight or 'whirlwind' reaming technique. Reamed cavities were scanned using a 3D laser scanner and the median difference between achieved and expected diameters compared. RESULTS: The novel reamer design was more accurate than the unused conventional reamer, using both whirlwind (0.1 mm (IQR 0-0.2) vs. 0.3 mm (IQR 0.3-0.4); p < 0.001) and straight techniques (0.3 mm (IQR 0.1-1.0) vs. 1.2 mm (IQR 1-1.6); p = 0.001). Whirlwind reaming was more accurate than straight reaming using both conventional (0.3 mm (IQR 0.3-0.4) vs. 1.2 mm (IQR 1-1.6); p < 0.0001) and single use reamers (0.1 mm (IQR 0-0.2) vs. 0.3 mm (IQR 0.1-1.0); p = 0.007). Reaming errors were higher in low-density bone compared to high-density bone, for both reamer types and reaming techniques tested (0.6 mm (IQR 0.3-1.5) vs. 0.3 mm (IQR 0.1-0.8); p = 0.005). CONCLUSION: We present a novel reamer design that demonstrates superior accuracy to conventional reamers in achieving the desired reaming diameter. Improved reaming accuracy was also demonstrated using both devices and in both bone models, using a 'whirlwind' technique. We recommend the use of this novel reamer design employing a 'whirlwind' technique to optimize reaming accuracy. Particular attention should be paid toward patients with lower bone quality which may be more susceptible to higher inaccuracies.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Humanos , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Instrumentos Cirúrgicos
9.
J Mech Behav Biomed Mater ; 138: 105573, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36525874

RESUMO

Measurement of the properties of bone as a material can happen in various length scales in its hierarchical and composite structure. The aim of this study was to test the tissue level properties of clinically-relevant human bone samples which were collected from donors belonging to three groups: ageing donors who suffered no fractures (Control); untreated fracture patients (Fx-Untreated) and patient who experienced hip fracture despite being treated with bisphosphonates (Fx-BisTreated). Tissue level properties were assessed by (a) nanoindentation and (b) synchrotron tensile tests (STT) where strains were measured at the 'tissue', 'fibril' and 'mineral' levels by using simultaneous Wide-angle - (WAXD) and Small angle- X-ray diffraction (SAXD). The composition was analysed by thermogravimetric analysis and material level endo- and exo-thermic reactions by differential scanning calorimetry (TGA/DSC3+). Irrespective of treatment fracture donors exhibited significantly lower tissue, fibril and mineral strain at the micro and nanoscale respectively and had a higher mineral content than controls. In nanoindentation only nanohardness was significantly greater for Controls and Fx-BisTreated versus Fx-Untreated. The other nanoindentation parameters did not vary significantly across the three groups. There was a highly significant positive correlation (p < 0.001) between organic content and tissue level strain behaviour. Overall hip-fractures were associated with lower STT nanostrains and it was behaviour measured by STT which proved to be a more effective approach for predicting fracture risk because evidently it was able to demonstrate the mechanical deficit for the bone tissue of the donors who had experienced fractures.


Assuntos
Osso e Ossos , Fraturas do Quadril , Humanos , Envelhecimento , Difração de Raios X , Minerais , Densidade Óssea
10.
Life (Basel) ; 13(6)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37374160

RESUMO

Bone mechanics is well understood at every length scale except the nano-level. We aimed to investigate the relationship between bone nanoscale and tissue-level mechanics experimentally. We tested two hypotheses: (1) nanoscale strains were lower in hip fracture patients versus controls, and (2) nanoscale mineral and fibril strains were inversely correlated with aging and fracture. A cross-sectional sample of trabecular bone sections was prepared from the proximal femora of two human donor groups (aged 44-94 years): an aging non-fracture control group (n = 17) and a hip-fracture group (n = 20). Tissue, fibril, and mineral strain were measured simultaneously using synchrotron X-ray diffraction during tensile load to failure, then compared between groups using unpaired t-tests and correlated with age using Pearson's correlation. Controls exhibited significantly greater peak tissue, mineral, and fibril strains than the hip fracture (all p < 0.05). Age was associated with a decrease in peak tissue (p = 0.099) and mineral (p = 0.004) strain, but not fibril strain (p = 0.260). Overall, hip fracture and aging were associated with changes in the nanoscale strain that are reflected at the tissue level. Data must be interpreted within the limitations of the observational cross-sectional study design, so we propose two new hypotheses on the importance of nanomechanics. (1) Hip fracture risk is increased by low tissue strain, which can be caused by low collagen or mineral strain. (2) Age-related loss of tissue strain is dependent on the loss of mineral but not fibril strain. Novel insights into bone nano- and tissue-level mechanics could provide a platform for the development of bone health diagnostics and interventions based on failure mechanisms from the nanoscale up.

11.
J Mech Behav Biomed Mater ; 136: 105468, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36244325

RESUMO

The bone quality of patients undergoing hip replacement surgery is poorly predicted by radiographs alone. With better bone quality information available to a surgeon, the operation can be performed more safely. The aim of this study was to investigate whether ultrasound signals of cortical bone at peripheral sites such as the tibia and radius can be used to predict the compressive mechanical properties of cortical bone at the femoral neck. We recruited 19 patients undergoing elective hip arthroplasty and assessed the radius and tibia of these patients with the Azalée guided wave ultrasound to estimate the porosity and thickness of the cortex. Excess bone tissues were collected from the femoral neck and the compressive mechanical properties of the cortex were characterised under a mechanical loading rig to determine stiffness, ultimate strength, and density. The correlations between the ultrasound measurements and mechanical properties were analysed using linear regression, Pearson correlation statistics, and multiple regression analysis. Cortical mechanical properties were weakly to moderately correlated with the ultrasound measurements at various sites (R2 = 0.00-0.36). The significant correlations found were not consistent across all 4 peripheral measurement sites. Additionally, weak to moderate ability of the ultrasound to predict mechanical properties at the neck of femur with multiple regression analysis was found (R2 = 0.00-0.48). Again, this was inconsistent across the different anatomical sites. Overall, the results demonstrate the need for ultrasound scans to be collected directly from clinically relevant sites such as the femoral neck due to the inconsistency of mechanical properties across various sites.


Assuntos
Artroplastia de Quadril , Colo do Fêmur , Humanos , Colo do Fêmur/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Osso Cortical , Radiografia , Densidade Óssea
12.
SICOT J ; 7: 15, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33749585

RESUMO

INTRODUCTION: Not using a tourniquet could improve early postoperative pain, range of motion (ROM), length of stay (LOS), and thromboembolic risk in patients undergoing total knee arthroplasty (TKA). Our aim was to compare these factors, intraoperative blood loss, and gender-related outcomes in patients undergoing primary TKA with or without a tourniquet. METHODS: We performed a retrospective cohort study of 97 patients undergoing TKA with or without tourniquet from 2018 to 2020. Revisions and bilateral TKAs were excluded. Blood loss was estimated using a validated formula. Postoperative pain was tested using the visual analogue scale (VAS). ROM and quadriceps lag were assessed by a physiotherapist on a postoperative day 2 and discharge. The index of suspicion for a thromboembolic event was defined as the number of embolic-related investigations ordered in the first 6 months post-surgery. The Shapiro-Wilk test was used to assess the distribution of the data, Mann-Whitney for the continuous variables, and Fischer's test for the categorical ones. RESULTS AND DISCUSSION: There was a significant difference in blood loss. The non-tourniquet group lost on average 32% more blood (1291 mL vs. 878 mL, p<0.001 two-tailed). We found no difference in pain, ROM, LOS, and quadriceps lag on day 2 and at discharge. There was one thromboembolic event in the tourniquet group, but the thromboembolic index of suspicion did not differ (p=0.53). With tourniquet use, women had a significantly lower day 2 maximum flexion than men (71.56° vs. 84.67°, p=0.02). In this retrospective cohort study, the results suggest that tourniquet use is associated with lower blood loss and similar postoperative pain, range of motion, quadriceps lag, length of stay, and thromboembolic risk. There might be some differences between how men and women tolerate a tourniquet, with women having worse short-term outcomes compared to men.

13.
J Bone Joint Surg Am ; 103(13): e51, 2021 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-34228669

RESUMO

BACKGROUND: We performed a systematic review of patient and public involvement in randomized controlled trials (RCTs) in the field of orthopaedic surgery. We assessed the prevalence, extent, and quality of patient and public involvement (PPI) in current academic orthopaedic practice. METHODS: A literature search of the Cochrane, MEDLINE, and Embase databases was performed; we identified RCTs that were published between 2013 and 2020 in the 10 orthopaedic surgery journals with the highest impact factors. Inclusion of studies was based on set criteria, and they were analyzed for their validity. The results were assessed for the rate and the quality of PPI reporting. The Wright and Foster guidelines and the GRIPP2-SF (Guidance for Reporting Involvement of Patients and the Public-2 short form) checklist were used to assess PPI reporting. This review was reported in line with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines. RESULTS: An initial 2,107 results were identified. After the screening process, 475 full-text articles were identified and reviewed. Two papers that described PPI were included in this review. One paper used PPI to inform the research question, the choice of primary outcome, the oversight of the study schedule, and the dissemination of the results. The second article used PPI to design the study protocol. Both articles poorly reported the impact of PPI on the research. CONCLUSIONS: To our knowledge, this systematic review is the first to describe the prevalence, extent, and quality of PPI reporting in orthopaedic RCTs. Barriers to adequate PPI reporting are multifactorial and stem from a lack of systematic uptake of PPI guidelines and a lack of compulsory PPI reporting from publishing bodies. CLINICAL RELEVANCE: PPI can improve the quality of clinical trials by focusing on the clinical questions and outcomes that are most important to patients. This article assesses the prevalence of PPI reporting in orthopaedic RCTs.


Assuntos
Pesquisa Biomédica/estatística & dados numéricos , Participação da Comunidade/estatística & dados numéricos , Procedimentos Ortopédicos/estatística & dados numéricos , Participação do Paciente/estatística & dados numéricos , Lista de Checagem , Guias como Assunto , Humanos , Publicações Periódicas como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
14.
Artigo em Inglês | MEDLINE | ID: mdl-34841185

RESUMO

BACKGROUND: Power tools are an integral part of orthopaedic surgery but have the capacity to cause iatrogenic injury. With this systematic review, we aimed to investigate the prevalence of iatrogenic injury due to the use of power tools in orthopaedic surgery and to discuss the current methods that can be used to reduce injury. METHODS: We performed a systematic review of English-language studies related to power tools and iatrogenic injuries using a keyword search in MEDLINE, Embase, PubMed, and Scopus databases. Exclusion criteria included injuries related to cast-saw use, temperature-induced damage, and complications not clearly related to power-tool use. RESULTS: A total of 3,694 abstracts were retrieved, and 88 studies were included in the final analysis. Few studies and individual case reports looked directly at the prevalence of injury due to power tools. These included 2 studies looking at the frequency of vascular injury during femoral fracture fixation (0.49% and 0.2%), 2 studies investigating the frequency of vertebral artery injury during spinal surgery (0.5% and 0.08%), and 4 studies investigating vascular injury during total joint arthroplasty (1 study involving 138 vascular injuries in 124 patients, 2 studies noting 0.13% and 0.1% incidence, and 1 questionnaire sent electronically to surgeons). There are multiple methods for preventing damage during power-tool use. These include the use of robotics and simulation, specific drill settings, and real-time feedback techniques such as spectroscopy and electromyography. CONCLUSIONS: Power tools have the potential to cause iatrogenic injury to surrounding structures during orthopaedic surgery. Fortunately, the published literature suggests that the frequency of iatrogenic injury using orthopaedic power tools is low. There are multiple technologies available to reduce damage using power tools. In high-risk operations, the use of advanced technologies to reduce the chance of iatrogenic injury should be considered. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

15.
Hip Int ; 30(1): 71-77, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30947562

RESUMO

INTRODUCTION: In arthroplasty surgery, positioning of the components must be accurate and reproducible to avoid complications. Conventional guides are often used to align a component, but they require surgical skill and experience, and are prone to error. To this end, a single-use, size-specific, nylon guide (single-use nylon guide) has been developed for the purpose of increasing the accuracy without adding extra cost to the operation. The effectiveness of this type of guide was evaluated in using a synthetic bone study. METHODS: A total of 66 synthetic femurs with the same osteoarthritic morphology were prepared. 3 surgeons participated in the experiments, and each surgeon created a drill hole for the femoral component by using the single-use nylon guide or a commercially-available, conventional, metal, neck-based guide (conventional guide). Anteversion, inclination, and insertion point acquired by the guide were compared between the guides, between surgeons, and to the computer-based plan. RESULTS: Anteversion acquired by the single-use nylon guide (6.7° [4.9-11.5°]) was significantly closer to the plan (14.6°) than that acquired by the conventional guide (4.3° [2.4-8.6°]) (p = 0.03). The insertion point was also significantly closer to the plan for the single-use nylon guide (3.8 mm ± 1.6 mm) than the conventional guide (5.7 mm ± 2.4 mm) (p < 0.001). No significant difference was found for the inclination (p = 0.76). CONCLUSION: A single-use, size-specific nylon guide was effective in acquiring a higher accuracy and precision in anteversion and insertion point than a conventional guide in this synthetic bone, hip resurfacing arthroplasty study. The use of single-use guides in other orthopaedic procedures should be explored.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Prótese de Quadril , Nylons , Cirurgia Assistida por Computador/métodos , Adulto , Feminino , Humanos , Masculino , Desenho de Prótese
16.
Sci Rep ; 10(1): 14208, 2020 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-32848149

RESUMO

Nanoscale mineralized collagen fibrils may be important determinants of whole-bone mechanical properties and contribute to the risk of age-related fractures. In a cross-sectional study nano- and tissue-level mechanics were compared across trabecular sections from the proximal femora of three groups (n = 10 each): ageing non-fractured donors (Controls); untreated fracture patients (Fx-Untreated); bisphosphonate-treated fracture patients (Fx-BisTreated). Collagen fibril, mineral and tissue mechanics were measured using synchrotron X-Ray diffraction of bone sections under load. Mechanical data were compared across groups, and tissue-level data were regressed against nano. Compared to controls fracture patients exhibited significantly lower critical tissue strain, max strain and normalized strength, with lower peak fibril and mineral strain. Bisphosphonate-treated exhibited the lowest properties. In all three groups, peak mineral strain coincided with maximum tissue strength (i.e. ultimate stress), whilst peak fibril strain occurred afterwards (i.e. higher tissue strain). Tissue strain and strength were positively and strongly correlated with peak fibril and mineral strains. Age-related fractures were associated with lower peak fibril and mineral strain irrespective of treatment. Indicating earlier mineral disengagement and the subsequent onset of fibril sliding is one of the key mechanisms leading to fracture. Treatments for fragility should target collagen-mineral interactions to restore nano-scale strain to that of healthy bone.


Assuntos
Envelhecimento/fisiologia , Osso e Ossos/fisiologia , Colágenos Fibrilares/fisiologia , Fraturas do Quadril/etiologia , Osteoporose/complicações , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Masculino , Nanoestruturas , Osteoporose/fisiopatologia
17.
J Orthop Res ; 37(5): 1123-1132, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30839114

RESUMO

In this computed tomography (CT) morphological study we describe the way the proximal femoral morphology differs with worsening degrees of developmental dysplasia of the hip (DDH) and describe gender differences in patients with DDH. Forty-nine male patients with DDH were matched with 49 females with DDH, using age and the Crowe classification of DDH severity. The femoral length, anteversion, neck-shaft angle, offset, neck length, canal-calcar ratio, canal flare index, lateral center-edge angle, alpha angle, pelvic tilt, and pelvic incidence were measured for each patient on their pre-operative CT scans, prior to total hip arthroplasty surgery. Femoral anteversion and neck length were 16° and 47 mm, 25°and 36 mm, 26° and 43 mm, and 44° and 36 mm, for Crowe I and III males and Crowe I and III females, respectively. The mean male anteversion was 22° (±14), compared to 30° (±15.5) in females (p = 0.02, Confidence Interval: 1.6-14.9). Gender differences in femoral length, neck length and offset lost significance when height-normalized and no other significant gender differences were found. In conclusion, femoral neck length reduces with increasing DDH severity, whilst anteversion tends to increase. Male patients with DDH have significantly less femoral anteversion, which has important implications for osteotomy and arthroplasty surgery in DDH. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.


Assuntos
Fêmur/patologia , Luxação Congênita de Quadril/patologia , Caracteres Sexuais , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
J Biomech ; 82: 220-227, 2019 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-30420174

RESUMO

Impaction is required to properly seat press-fit implants and ensure initial implant stability and long term bone ingrowth, however excessive impaction or press-fit presents a high fracture risk in the acetabulum and femur. Current in-vitro impaction testing methods do not replicate the compliance of the soft tissues surrounding the hip, a factor that may be important in fracture and force prediction. This study presents the measurement of compliance of the soft tissues supporting the hip during impaction in operative conditions, and replicates these in vitro. Hip replacements were carried out on 4 full body cadavers while impact force traces and acetabular/femoral displacement were measured. Compliance was then simulated computationally using a Voigt model. These data were subsequently used to inform the design of a representative in-vitro drop rig. Effective masses of 19.7 kg and 12.7 kg, spring stiffnesses of 8.0 kN/m and 4.1 kN/m and dashpot coefficients of 595 N s/m and 322 N s/m were calculated for the acetabular and femoral soft tissues respectively. A good agreement between cadaveric and in-vitro peak displacement and rise time during impact is found. Such an in-vitro setup is of use during laboratory testing, simulation or even surgical training.


Assuntos
Artroplastia de Quadril , Fenômenos Mecânicos , Acetábulo/citologia , Acetábulo/cirurgia , Idoso de 80 Anos ou mais , Feminino , Fêmur/citologia , Fêmur/cirurgia , Prótese de Quadril , Humanos , Masculino
19.
Appl Mater Today ; 15: 377-388, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31281871

RESUMO

An increasing volume of work supports utilising the mechanobiology of bone for bone ingrowth into a porous scaffold. However, typically during in vivo testing of implants, the mechanical properties of the bone being replaced are not quantified. Consequently there remains inconsistencies in the literature regarding 'optimum' pore size and porosity for bone ingrowth. It is also difficult to compare ingrowth results between studies and to translate in vivo animal testing to human subjects without understanding the mechanical environment. This study presents a clinically applicable approach to determining local bone mechanical properties and design of a scaffold with similar properties. The performance of the scaffold was investigated in vivo in an ovine model. The density, modulus and strength of trabecular bone from the medial femoral condyle from ovine bones was characterised and power-law relationships were established. A porous titanium scaffold, intended to maintain bone mechanical homeostasis, was additively manufactured and implanted into the medial femoral condyle of 6 ewes. The stiffness of the scaffold varied throughout the heterogeneous structure and matched the stiffness variation of bone at the surgical site. Bone ingrowth into the scaffold was 10.73±2.97% after 6 weeks. Fine woven bone, in the interior of the scaffold, and intense formations of more developed woven bone overlaid with lamellar bone at the implant periphery were observed. The workflow presented will allow future in vivo testing to test specific bone strains on bone ingrowth in response to a scaffold and allow for better translation from in vivo testing to commercial implants.

20.
Biomaterials ; 194: 183-194, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30611115

RESUMO

This study explored the regenerative osteogenic response in the distal femur of sheep using scaffolds having stiffness values within, and above and below, the range of trabecular bone apparent modulus. Scaffolds 3D-printed from stiff titanium and compliant polyamide were implanted into a cylindrical metaphyseal defect 15 × 15 mm. After six weeks, bone ingrowth varied between 7 and 21% of the scaffold pore volume and this was generally inversely proportional to scaffold stiffness. The individual reparative response considerably varied among the animals, which could be divided into weak and strong responders. Notably, bone regeneration specifically within the interior of the scaffold was inversely proportional to scaffold stiffness and was strain-driven in strongly-responding animals. Conversely, bone regeneration at the periphery of the defect was injury-driven and equal in all scaffolds and in all strongly- and weakly-responding animals. The observation of the strain-driven response in some, but not all, animals highlights that scaffold compliance is desirable for triggering host bone regeneration, but scaffold permanence is important for the load-bearing, structural role of the bone-replacing device. Indeed, scaffolds may benefit from being nonresorbable and mechanically reliable for those unforeseeable cases of weakly responding recipients.


Assuntos
Regeneração Óssea , Substitutos Ósseos/química , Fêmur/lesões , Alicerces Teciduais/química , Titânio/química , Animais , Feminino , Fêmur/fisiologia , Fêmur/ultraestrutura , Dureza , Nylons/química , Porosidade , Impressão Tridimensional , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA