Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pediatr Nephrol ; 38(8): 2827-2837, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36625933

RESUMO

BACKGROUND: The Cardio-Renal Pediatric Dialysis Emergency Machine (CA.R.P.E.D.I.E.M.®) device is a continuous kidney replacement therapy (CKRT) equipment dedicated to neonates and small infants. This study aimed to assess the effectiveness, feasibility, outcomes, and technical considerations relating to CARPEDIEM® use. METHODS: This retrospective multicenter study included 19 newborns and six infants receiving CARPEDIEM® in five French pediatric and neonatal intensive care units. Laboratory parameters were collected at the initiation and end of the first CARPEDIEM® session. Results are presented as median [IQR] (range). RESULTS: At initiation, age was 4 days [2-13] (1-1134) with a body weight of 3.3 kg [2.5-4] (1.3-11.1). Overall, 131 sessions and 2125 h of treatment were performed. Treatment duration per patient was 42 h [24-91] (8-557). Continuous veno-venous hemofiltration (CVVH) was performed in 20 children. Blood flow rate was 8 mL/kg/min [6-9] (3-16). The effluent flow rate for CVVH was 74 mL/kg/h [43-99] (28-125) and net ultrafiltration (UF) 6 mL/kg/h [2-8] (1-12). In the five children treated by hemodialysis, the blood and dialysate flow rates were 6 mL/kg/min [5-7] (4-7) and 600 mL/h [300-600] (120-600), respectively, while session duration was 8 h [6-12] (2-24). Most infants required a catheter between 4.5 and 6.5 French. Hemodynamic instability with a need for volume replacement occurred in 31 sessions (23%). Thrombocytopenia was observed in 29 sessions (22%). No hemorrhage occurred; all the patients survived the sessions, but only eight patients (32%) were alive at hospital discharge. CONCLUSIONS: These data confirm that the use of CARPEDIEM® is safe and effective in critically ill neonates and infants. A higher resolution version of the Graphical abstract is available as Supplementary information.


Assuntos
Injúria Renal Aguda , Terapia de Substituição Renal Contínua , Hemofiltração , Lactente , Humanos , Criança , Recém-Nascido , Estudos Retrospectivos , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Ultrafiltração , Injúria Renal Aguda/terapia
2.
Crit Care ; 23(1): 281, 2019 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-31420052

RESUMO

BACKGROUND: A peripheral perfusion-targeted resuscitation during early septic shock has shown encouraging results. Capillary refill time, which has a prognostic value, was used. Adding accuracy and predictability on capillary refill time (CRT) measurement, if feasible, would benefit to peripheral perfusion-targeted resuscitation. We assessed whether a reduction of capillary refill time during passive leg raising (ΔCRT-PLR) predicted volume-induced peripheral perfusion improvement defined as a significant decrease of capillary refill time following volume expansion. METHODS: Thirty-four patients with acute circulatory failure were selected. Haemodynamic variables, metabolic variables (PCO2gap), and four capillary refill time measurements were recorded before and during a passive leg raising test and after a 500-mL volume expansion over 20 min. Receiver operating characteristic curves were built, and areas under the curves were calculated (ROCAUC). Confidence intervals (CI) were performed using a bootstrap analysis. We recorded mortality at day 90. RESULTS: The least significant change in the capillary refill time was 25% [95% CI, 18-30]. We defined CRT responders as patients showing a reduction of at least 25% of capillary refill time after volume expansion. A decrease of 27% in ΔCRT-PLR predicted peripheral perfusion improvement with a sensitivity of 87% [95% CI, 73-100] and a specificity of 100% [95% CI, 74-100]. The ROCAUC of ΔCRT-PLR was 0.94 [95% CI, 0.87-1.0]. The ROCAUC of baseline capillary refill time was 0.73 [95% CI, 0.54-0.90] and of baseline PCO2gap was 0.79 [0.61-0.93]. Capillary refill time was significantly longer in non-survivors than in survivors at day 90. CONCLUSION: ΔCRT-PLR predicted peripheral perfusion response following volume expansion. This simple low-cost and non-invasive diagnostic method could be used in peripheral perfusion-targeted resuscitation protocols. TRIAL REGISTRATION: CPP Lyon Sud-Est II ANSM: 2014-A01034-43 Clinicaltrial.gov, NCT02248025 , registered 13th of September 2014.


Assuntos
Capilares/fisiologia , Débito Cardíaco/fisiologia , Substitutos do Plasma/normas , Choque/sangue , Idoso , Área Sob a Curva , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Substitutos do Plasma/uso terapêutico , Estudos Prospectivos , Curva ROC , Choque/fisiopatologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA