Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Card Fail ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851449

RESUMO

BACKGROUND: Prediction of outcomes remains an unmet need in candidates for LVADs. The development of right-heart failure portends an excess in mortality rates, but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling as a surrogate parameter at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular-plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (P = 0.89), nor was the pulmonary artery pulsatility index (PAPi) (P = 0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (P < 0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen levels, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65]; P < 0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.

2.
Crit Care Med ; 50(5): e426-e433, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-34974497

RESUMO

OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Resultado do Tratamento
3.
Ann Vasc Surg ; 86: 373-379, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35395379

RESUMO

BACKGROUND: Thoracic endovascular aortic repair (TEVAR) is the standard treatment for acute complicated type B aortic dissection (TBAD). However, long-term results reveal that TEVAR does not achieve a complete aortic remodeling and poses a risk of aneurysmal aortic degeneration. Distal re-entry treatment at the abdominal level seems to be necessary to obtain a complete remodeling in TBAD. Moreover, it is necessary to treat the aortoiliac bifurcation in patients with persistent true lumen collapse or limb ischemia. METHODS: Between January 2018 and October 2019, 11 patients with acute or sub-acute complicated TBAD or non-A non-B aortic dissection were treated in our institution in an endovascular fashion. We performed the stent-assisted, balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) technique in all cases, but 2 cases required complementary treatment of the aortoiliac bifurcation with a bifurcated AFX endograft system for limb ischemia due to true lumen collapse. RESULTS: Technical success was obtained in all patients. No procedural complications occurred. No postoperative deaths, stroke, paraplegia, mesenteric, or renal ischemia were observed, and no secondary intervention was necessary. Satisfactory aortic re-modeling was obtained after the follow-up periods with a 57.5% mean true lumen expansion. CONCLUSIONS: Our initial experience using the extended STABILISE (e-STABILISE) technique using a bifurcated AFX endograft did not result in any postoperative mortality or complications. Without additional data, this technique should be reserved for specific patients who require revascularization of the aortoiliac bifurcation.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Stents , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Estudos Retrospectivos , Prótese Vascular
4.
Circulation ; 141(4): 260-268, 2020 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-31736332

RESUMO

BACKGROUND: Two competing transcatheter aortic valve replacement (TAVR) technologies are currently available. Head-to-head comparisons of the relative performances of these 2 devices have been published. However, long-term clinical outcome evaluation remains limited by the number of patients analyzed, in particular, for recent-generation devices. METHODS: Based on the French administrative hospital-discharge database, the study collected information for all consecutive patients treated with a TAVR device commercialized in France between 2014 and 2018. Propensity score matching was used for the analysis of outcomes during follow-up. The objective of this study was to analyze the outcomes of TAVR according to Sapien 3 balloon-expandable (BE) versus Evolut R self-expanding TAVR technology at a nationwide level in France. RESULTS: A total of 31 113 patients treated with either Sapien 3 BE or Evolut R self-expanding TAVR were found in the database. After matching on baseline characteristics, 20 918 patients were analyzed (10 459 in each group with BE or self-expanding valves). During follow-up (mean [SD], 358 [384]; median [interquartile range], 232 [10-599] days), BE TAVR was associated with a lower yearly incidence of all-cause death (relative risk, 0.88; corrected P=0.005), cardiovascular death (relative risk, 0.82; corrected P=0.002), and rehospitalization for heart failure (relative risk, 0.84; corrected P<0.0001). BE TAVR was also associated with lower rates of pacemaker implantation after the procedure (relative risk, 0.72; corrected P<0.0001). CONCLUSIONS: On the basis of the largest cohort available, we observed that Sapien 3 BE valves were associated with lower rates of all-cause death, cardiovascular death, rehospitalization for heart failure, and pacemaker implantation after a TAVR procedure.


Assuntos
Estenose da Valva Aórtica , Bases de Dados Factuais , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Intervalo Livre de Doença , Feminino , Seguimentos , França , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Humanos , Estudos Longitudinais , Masculino , Readmissão do Paciente , Estudos Retrospectivos , Taxa de Sobrevida
5.
J Vasc Surg ; 72(6): 2120-2129.e2, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32276023

RESUMO

OBJECTIVE: Vascular complications (VCs) occurring in transcatheter aortic valve implantation (TAVI) procedures have frequently been reported in the past. Considering significant technical improvements in delivery systems and vascular closure devices, the goal of this study was to determine the incidence, impact, and prognostic factors of VCs in a recent real-world cohort. METHODS: We report a bicentric prospective analysis of 479 consecutive patients who underwent TAVI between January 2017 and December 2017. VCs were defined according to criteria set out by the Valve Academic Research Consortium (VARC)-2. RESULTS: The incidence of VCs was 26.1% (n = 125 patients), of which 2.9% were major (n = 14) and 23.2% were minor (n = 111). VCs were related to the primary puncture point in 69% of cases compared with 31% at the secondary puncture site. Treatments implemented were medical in 76% of cases and surgical in 24% of cases. The risk factors for VCs were as follows: iliac morphology score, sheath to iliofemoral artery ratio (SIFAR), and moderate-severe iliofemoral calcifications or tortuosity. In the case of major VCs, only sheath to iliofemoral artery ratio was a risk factor. Major VCs significantly increased intrahospital mortality (30.7% vs 1.1% for minor VCs and 1.3% for no VCs; log-rank, P < .0001) and 1-year mortality (40.6% vs 5.6% for minor VCs and 5.6% for no VCs; log-rank, P < .0001). CONCLUSIONS: Using strictly VARC-2 end point definitions, more than one-quarter of TAVI procedures were associated with VCs, primarily minor ones. Secondary puncture points were responsible for one-third of VCs and should therefore also be actively monitored. Major VCs have a significant impact on short-term and midterm survival.


Assuntos
Cateterismo Periférico/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doenças Vasculares/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/mortalidade , Feminino , França/epidemiologia , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Prognóstico , Estudos Prospectivos , Punções/efeitos adversos , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/mortalidade , Doenças Vasculares/diagnóstico , Doenças Vasculares/mortalidade , Doenças Vasculares/terapia
6.
Pacing Clin Electrophysiol ; 43(11): 1309-1317, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32627211

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead dysfunction has been reported after left ventricular assist device (LVAD) implantation in limited single-center studies. We aimed at describing and characterizing the incidence of ICD lead parameters dysfunction after LVAD implantation. METHODS: Among the 652 patients enrolled in the ASSIST-ICD study, only patients with an ICD prior to LVAD were included (n = 401). ICD lead parameters dysfunction following LVAD implantation is defined as follows: (a) >50% decrease in sensing threshold, (b) pacing lead impedance increase/decrease by >100Ω, and (c) >50% increase in pacing threshold. RESULTS: One hundred twenty-two patients with an ICD prior to LVAD had available ICD interrogation reports prior and after LVAD. A total of 67 (55%) patients exhibited at least one significant lead dysfunction: 17 (15%) exhibited >50% decrease in right ventricular (RV) sensing, 51 (42%) had >100 Ω increase/decrease in RV pacing impedance, and 24 (20%) experienced >50% increase in RV pacing threshold. A total of 52 patients experienced ventricular arrhythmia during follow-up and all were successfully detected and treated by the device. All lead dysfunction could be managed conservatively. CONCLUSION: More than 50% of LVAD-recipients may experience >1 significant change in lead parameters but none had severe clinical consequences.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Coração Auxiliar , Idoso , França , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
7.
Circulation ; 137(4): 388-399, 2018 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29358344

RESUMO

Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.


Assuntos
Bioprótese/classificação , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/classificação , Valvas Cardíacas/cirurgia , Falha de Prótese , Terminologia como Assunto , Substituição da Valva Aórtica Transcateter/instrumentação , Remoção de Dispositivo , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/fisiopatologia , Humanos , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Am Heart J ; 214: 69-76, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31174053

RESUMO

BACKGROUND: Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections. METHODS: Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up. RESULTS: Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5 months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7 years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (n = 113' 45.4%), Enterobacteriaceae (n = 61; 24.6%), Pseudomonas aeruginosa (n = 34; 13.7%), coagulase-negative staphylococci (n = 13; 5.2%), and Candida species (n = 13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; P = .031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; P = .031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival. CONCLUSIONS: Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.


Assuntos
Infecções Relacionadas a Cateter/etiologia , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/mortalidade , Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Feminino , França/epidemiologia , Ventrículos do Coração , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Estudos Retrospectivos , Fatores de Risco
9.
J Cardiovasc Magn Reson ; 20(1): 59, 2018 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-30153847

RESUMO

BACKGROUND: The diagnosis of acute rejection in cardiac transplant recipients requires invasive technique with endomyocardial biopsy (EMB) which has risks and limitations. Cardiovascular magnetic resonance imaging (CMR) with T2 and T1 mapping is a promising technique for characterizing myocardial tissue. The purpose of the study was to evaluate T2, T1 and extracellular volume fraction (ECV) quantification as novel tissue markers to diagnose acute rejection. METHODS: CMR was prospectively performed in 20 heart transplant patients providing 31 comparisons EMB-CMR. CMR was performed close to EMB. Images were acquired on a 1.5 Tesla scanner including T2 mapping (T2 prepared balanced steady state free precession) and T1 mapping (modified Look-Locker inversion recovery sequences: MOLLI) at basal, mid and apical level in short axis view. Global and segmental T2 and T1 values were measured before and 15 min (for T1 mapping) after contrast administration. RESULTS: Acute rejection was diagnosed in seven patients: six cellular rejections (4 grade IR, 2 grade 2R) and one antibody mediated rejection. Patients with acute rejection had significantly higher global T2 values at 3 levels: 58.5 ms [55.0-60.3] vs 51.3 ms [49.5-55.2] (p = 0.007) at basal; 55.7 ms [54.0-59.7] vs 51.8 ms [50.1-53.6] (p = 0.002) at median and 58.2 ms [54.0-63.7] vs 53.6 ms [50.8-57.4] (p = 0.026) at apical level. The area under the curve (AUC) for each level was 0.83, 0.79 and 0.78 respectively. Patients with acute rejection had significantly higher ECV at basal level: 34.2% [32.8-37.4] vs 27.4% [24.6-30.6] (p = 0.006). The AUC for basal level was 0.84. The sensitivity, specificity and diagnosis accuracy for basal T2 (cut off: 57.7 ms) were 71, 96 and 90% respectively; and for basal ECV: (cut off 32%) were 86, 85 and 85% respectively. Combining basal T2 and basal ECV allowed diagnosing all acute rejection and avoiding 63% of EMB. CONCLUSIONS: In heart transplant patients, a combined CMR approach using T2 mapping and ECV quantification provides a high diagnostic accuracy for acute rejection diagnosis and could potentially decrease the number of routine EMB.


Assuntos
Rejeição de Enxerto/diagnóstico por imagem , Transplante de Coração/efeitos adversos , Imageamento por Ressonância Magnética , Miocárdio/patologia , Doença Aguda , Adulto , Biópsia , Estudos de Casos e Controles , Feminino , Rejeição de Enxerto/imunologia , Rejeição de Enxerto/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco , Resultado do Tratamento
12.
J Heart Valve Dis ; 25(2): 187-194, 2016 03.
Artigo em Inglês | MEDLINE | ID: mdl-27989065

RESUMO

BACKGROUND: The repair of anterior mitral leaflet prolapse is known to be challenging. Hence, the study aim was to compare the mid-term results of anterior leaflet prolapse (ALP) using chordal transposition with results obtained using chordal replacement with expanded polytetrafluoroethylene (ePTFE) sutures. METHODS: Between 1999 and 2012, a total of 96 consecutive patients (mean age 62 years) with ALP underwent mitral valve repair at the authors' institution. Surgery involved either chordal transposition from the posterior to the anterior leaflet (n = 67), or chordal replacement using ePTFE sutures (n = 29). Clinical, operative and follow up data were recorded prospectively for each patient. The follow up was 100% complete (mean 3.4 years; range 0 to 12.9 years). RESULTS: Mitral valve repair was accomplished in all patients, with no operative mortality. The durations of cardiopulmonary bypass and aortic cross-clamp were significantly longer in the chordal replacement group. Actuarial overall survival at one, five and 10 years was 95 ± 3%, 87 ± 5% and 82 ± 7% versus 89 ± 6%, 89 ± 6% and 89 ± 6% in the chordal transposition and chordal replacement groups, respectively (p = 0.84). Freedom from reoperation in the two groups at five years was 95 ± 3% and 91 ± 7%, respectively (p = 0.24). The recurrence of moderate or severe mitral regurgitation (MR) (grade ≤2+) and of severe (grade ≤3+) MR was significantly higher in patients who underwent chordal replacement compared to chordal transposition (p = 0.04 and p = 0.01, respectively). CONCLUSIONS: Provided that chordal quality is preserved, chordal transposition is easier and quicker to achieve for ALP repair, and is also durable in the mid term. Chordal replacement offers a satisfying durability even if the recurrence of severe MR appears to be higher. Preferably, both surgical techniques should be mastered to allow valve repair when anatomic conditions prevent chordal transposition.


Assuntos
Cordas Tendinosas/cirurgia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Técnicas de Sutura , Adulto , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/mortalidade , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/fisiopatologia , Intervalo Livre de Doença , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/mortalidade , Prolapso da Valva Mitral/fisiopatologia , Duração da Cirurgia , Politetrafluoretileno , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Quebeque , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Técnicas de Sutura/efeitos adversos , Técnicas de Sutura/instrumentação , Técnicas de Sutura/mortalidade , Suturas , Fatores de Tempo , Resultado do Tratamento
13.
Eur Heart J ; 36(28): 1822-30, 2015 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-25994754

RESUMO

AIMS: The CHA2DS2VASc score is a clinical risk stratification tool which estimates the risk of stroke and thromboembolism in non-valvular atrial fibrillation (AF). We aimed to establish the value of this score for risk evaluation in patients with non-valvular AF and valvular heart disease. METHODS AND RESULTS: Among 8053 patients with non-valvular AF (ESC guidelines definition), patients were categorized into Group 1 (no valve disease, n = 6851; 85%) and Group 2 (valve disease with neither rheumatic mitral stenosis nor valve prothesis, n = 1202; 15%). After follow-up of 868 ± 1043 days, 627 stroke/ thromboembolic (TE) events were recorded. Group 2 was significantly older, had a higher CHA2DS2VASc score and had a higher risk of thromboembolic events [hazard ratio (HR) 1.39; 95% CI 1.14-1.69, P = 0.001] compared with Group 1. Severe valve disease was not associated with worse prognosis for stroke/TE events. In the two groups, stroke/TE risk increased with a higher CHA2DS2VASc score. Factors independently associated with increased risk of stroke/TE events were older age (HR 1.25, 95% CI 1.14-1.36 per 10-year increase, P < 0.0001) and higher CHA2DS2VASc score (HR 1.33, 95% CI 1.23-1.45, P < 0.0001). The predictive value (c-statistic) of the CHA2DS2VASc score was similar in the two groups. CONCLUSION: In patients with non-valvular AF, left-sided valvular heart disease (excluding mitral stenosis and protheses) was associated with an increased risk of stroke/TE events. A higher CHA2DS2VASc score in these patients is likely to explain these results.


Assuntos
Fibrilação Atrial/mortalidade , Doenças das Valvas Cardíacas/mortalidade , Índice de Gravidade de Doença , Idoso , Fibrilação Atrial/complicações , Feminino , Doenças das Valvas Cardíacas/complicações , Humanos , Estimativa de Kaplan-Meier , Masculino , Prognóstico , Medição de Risco/métodos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Tromboembolia/etiologia , Tromboembolia/mortalidade
14.
ESC Heart Fail ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38581135

RESUMO

AIMS: Right ventricular failure after left ventricular assist device (LVAD) implantation is a major concern that remains challenging to predict. We sought to investigate the relationship between preoperative pulmonary artery pulsatility index (PAPi) and mortality after LVAD implantation. METHODS AND RESULTS: A retrospective analysis of the ASSIST-ICD multicentre registry allowed the assessment of PAPi before LVAD according to the formula [(systolic pulmonary artery pressure - diastolic pulmonary artery pressure)/central venous pressure]. The primary endpoint was survival at 3 months, according to the threshold value of PAPi determined by the receiver operating characteristic (ROC) curve. A multivariate analysis including demographic, echographic, haemodynamic, and biological variables was performed to identify predictive factors for 2 year mortality. One hundred seventeen patients were included from 2007 to 2021. The mean age was 58.45 years (±13.16), with 15.4% of women (sex ratio 5.5). A total of 53.4% were implanted as bridge to transplant and 43.1% as destination therapy. Post-operative right ventricular failure was observed in 57 patients (48.7%), with no significant difference between survivors and non-survivors at 1 month (odds ratio 1.59, P = 0.30). The median PAPi for the whole study population was 2.83 [interquartile range 1.63-4.69]. The threshold value of PAPi determined by the ROC curve was 2.84. Patients with PAPi ≥ 2.84 had a higher survival rate at 3 months [PAPi < 2.84: 58.1% [46.3-72.8%] vs. PAPi ≥ 2.84: 89.1% [81.1-97.7%], hazard ratio (HR) 0.08 [0.02-0.28], P < 0.01], with no significant difference after 3 months (HR 0.67 [0.17-2.67], P = 0.57). Other predictors of 2 year mortality were systemic hypertension (HR 4.22 [1.49-11.97], P < 0.01) and diabetes mellitus (HR 4.90 [1.83-13.14], P < 0.01). LVAD implantation as bridge to transplant (HR 0.18 [0.04-0.74], P = 0.02) and heart transplantation (HR 0.02 [0.00-0.18], P < 0.01) were associated with a higher survival rate at 2 years. CONCLUSIONS: Preoperative PAPi < 2.84 was associated with a higher risk of early mortality after LVAD implantation without impacting 2 year outcomes among survivors.

15.
Artigo em Inglês | MEDLINE | ID: mdl-37981099

RESUMO

OBJECTIVE: This study evaluated the very long-term results of the Carpentier-Edwards pericardial bioprosthesis in the mitral position, with particular attention to structural valve deterioration based on echocardiographic criteria. METHODS: From 1984 to 2016, 648 patients (mean age 68.8 years; 53.9% female) underwent mitral valve replacement using the Carpentier-Edwards PERIMOUNT pericardial bioprosthesis. Multiple valve replacements were excluded. Clinical, operative, and follow-up data were prospectively recorded. The mean follow-up was 7.8 ± 5.4 years, for a total of 5043 valve-years. The follow-up data were 98.3% complete (11 patients lost). Structural valve deterioration was determined by strict echocardiographic assessment based on Heart Valve Collaboratory criteria. RESULTS: Operative mortality was 4%. A total of 322 late deaths occurred, for a linearized rate of 6.4%/valve-year. The actuarial survival rate at 15 years was 31.4 ± 2.6%. Age at implantation, male sex, and preoperative New York Heart Association class III or IV were significant risk factors affecting late survival. Actuarial freedoms from complications at 15 years were thromboembolism, 92.5 ± 1.9%; major bleeding, 93.8 ± 1.7%; endocarditis, 93.2 ± 1.3%; and explantation due to structural valve deterioration, 69.3 ± 3.5%. The median survival time for explantation due to structural valve deterioration was 21.7 years for the entire cohort (16.1 years for patients <65 years old). Based on echocardiographic data, actuarial freedom from severe and moderate/severe structural valve deterioration at 15 years were 64.0 ± 3.6% and 52.1 ± 3.6%, respectively. CONCLUSIONS: With low 15-year rates of valve-related events and structural valve deterioration based on Heart Valve Collaboratory echocardiographic criteria, the Carpentier-Edwards PERIMOUNT pericardial bioprosthesis remains a reliable choice for a mitral tissue valve.

16.
Artigo em Inglês | MEDLINE | ID: mdl-37462612

RESUMO

OBJECTIVES: We report 1-year safety and clinical outcomes in patients <60 years undergoing bioprosthetic surgical aortic valve intervention. METHODS: The INSPIRIS RESILIA Durability Registry is a prospective, multicentre registry to assess clinical outcomes of patients <60 years. Patients with planned SAVR with or without concomitant replacement of the ascending aorta and/or coronary bypass surgery were included. Time-related valve safety, haemodynamic performance and quality of life (QoL) at 1 year were assessed. RESULTS: A total of 421 patients were documented with a mean age of 53.5 years, 76.5% being male and 27.2% in NYHA class III/IV. Outcomes within 30 days included cardiovascular-related mortality (0.7%), time-related valve safety (VARC-2; 5.8%), thromboembolic events (1.7%), valve-related life-threatening bleeding (VARC-2; 4.3%) and permanent pacemaker implantation (3.8%). QoL was significantly increased at 6 months and sustained at 1 year. Freedom from all-cause mortality at 1 year was 98.3% (95% confidence interval 97.1; 99.6) and 81.8% were NYHA I versus 21.9% at baseline. No patient developed structural valve deterioration stage 3 (VARC-3). The mean aortic pressure gradient was 12.6 mmHg at 1 year and the effective orifice area was 1.9 cm2. CONCLUSIONS: The 1-year data from the INSPIRIS RESILIA valve demonstrate good safety and excellent haemodynamic performance as well as an early QoL improvement. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov: NCT03666741.

17.
JTCVS Open ; 11: 72-80, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36172410

RESUMO

Objectives: The Carpentier-Edwards Perimount Magna Ease (Edwards Lifesciences) pericardial bioprosthesis has demonstrated satisfying hemodynamics at midterm follow-up, but its durability remains unclear. We report our 10-year experience with this third-generation valve implanted in the aortic position, with particular attention to structural valve deterioration. Methods: From 2007 to 2016 at our center, 338 patients underwent aortic valve replacement using the Perimount Magna Ease pericardial bioprosthesis. Patients were prospectively followed (mean 6.6 ± 2.6 years) with clinical evaluation and yearly echocardiography. Follow-up was 98% complete (7 patients lost) for a total of 2238 valve-years. Bioprosthesis structural valve deterioration was determined by strict echocardiographic assessment based on the Valve Academic Research Consortium 3 criteria. Results: Overall operative mortality was 1.2%. Actuarial survival including early deaths averaged 80.9% ± 2.2% and 66.7% ± 4.4% after 5 and 10 years of follow-up, respectively. Actuarial freedom from explantation due to structural valve deterioration at 5 and 10 years was 99.6% ± 0.4% and 88.8% ± 5.0%, respectively, and actuarial freedom of structural valve deterioration at 5 and 10 years was 98.5% ± 0.7% and 44.0% ± 6.4%, respectively. More precisely, actuarial freedom of structural valve deterioration stage 3 was 99.6% ± 0.4% at 5 years and 88.3% ± 5.0% at 10 years, whereas freedom of structural valve deterioration stage 2/3 was 98.5% ± 0.7% and 60.9% ± 7.0%, respectively. Conclusions: With a low rate of explantation due to structural valve deterioration events at 10 years, and particularly a low rate of moderate or severe structural valve deterioration based on echocardiographic Valve Academic Research Consortium 3 criteria, the Carpentier-Edwards Perimount Magna Ease pericardial bioprosthesis remains a reliable choice for a tissue valve in the aortic position.

18.
Mayo Clin Proc ; 97(5): 905-918, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35184879

RESUMO

OBJECTIVE: To analyze the outcomes of patients presenting with ST-segment elevation myocardial infarction (STEMI) without early (<48 hours) revascularization, according to percutaneous versus surgical revascularization. PATIENTS AND METHODS: Based on the French administrative hospital discharge database, the study collected information for all consecutive patients seen for a STEMI in France between January 1, 2010, to June 31, 2019, who underwent either a first percutaneous coronary intervention (PCI) or a first coronary artery bypass graft between 48 hours and 90 days after the index hospitalization. Propensity score matching was used for the analysis of outcomes. RESULTS: Of 71,365 patients with STEMI in the analysis, 59,340 patients underwent PCI and 12,025 patients underwent coronary artery bypass graft. In a matched analysis of 12,012 patients by arm, surgical revascularization was associated with lower rates of all cause (5.1% vs 7.1%; hazard ratio [HR], 0.70; 95% CI, 0.66 to 0.75) and cardiovascular (2.6% vs 3.1%; HR, 0.83; 95% CI, 0.76 to 0.91) death. Rehospitalization for heart failure was less often reported after surgery (5.5% vs 7.5%; HR, 0.76; 95% CI, 0.71 to 0.81) whereas stroke incidence was not statistically different between the two arms (2.1% vs 2.3%; HR, 0.90; 95% CI, 0.80 to 1.00). Major bleeding was less often reported in the PCI arm (4.6% vs 6.1%; HR, 1.31; 95% CI, 1.22 to 1.41). CONCLUSION: In patients with STEMI who did not undergo urgent revascularization (ie, within 48 hours after presentation), surgical revascularization was associated with better outcomes and should be individually considered as an alternative to PCI.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Acidente Vascular Cerebral , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/epidemiologia , Humanos , Revascularização Miocárdica , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
19.
J Heart Valve Dis ; 20(6): 673-80, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22655498

RESUMO

BACKGROUND AND AIM OF THE STUDY: Currently, valve thrombosis, thromboembolic events and bleeding events account for 75% of all complications that occur after mechanical heart valve replacement. The study aim was to determine the main risk factors for valve-related complications in patients undergoing mechanical heart valve replacement. METHODS: Data were available from the systematic follow up of patients who had received a CarboMedics bileaflet mechanical heart valve replacement at the authors' institution. Follow up examinations were conducted prospectively at two-year intervals, via questionnaires sent to the patients' general practitioners, or by telephone calls. RESULTS: Between January 1988 and December 2005, a total of 505 consecutive patients (300 males, 205 females; mean age 52 years; range: 5 to 77 years) underwent heart valve replacement using a CarboMedics mechanical prosthesis. Aortic valve replacement (AVR) was performed in 308 patients, mitral valve replacement (MVR) in 134 patients, and double-valve replacement (DVR) in 62 patients. The follow up was 95.4% complete; the mean follow up was 7.5 years, and the total follow up 3,718 patient-years. Thromboembolic and bleeding complications represented the leading cause of valve-related events (104/195), of valve-related mortality (15/25), and of the need for repeat surgery (9/16). Valve thrombosis occurred in 12 patients. Implantation in the mitral position was identified as a risk factor (HR = 15.07; CI: 8.41-23.07; p 0.0001). Thromboembolism occurred in 32 patients; the use of antiplatelet agents was found to be a protective factor (HR = 0.23; CI: 0.08-0.70; p = 0.01). Bleeding events occurred in 52 patients; risk factors for bleeding events included a history of thromboembolic or bleeding complications (HR = 2.70; CI: 1.33-5.26; p = 0.006) and an unstable International Normalized Ratio (INR) (HR = 2.86; CI: 1.01-8.08; p = 0.05). CONCLUSION: After mechanical heart valve replacement, the only risk factors for bleeding complications were an unstable INR and a history of thromboembolic or bleeding events. The use of antiplatelet agents proved to be a protective factor against thromboembolic events.


Assuntos
Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias/mortalidade , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Seguimentos , França/epidemiologia , Hemorragia/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Fatores de Risco , Trombose/epidemiologia , Adulto Jovem
20.
Arch Cardiovasc Dis ; 114(1): 41-50, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32532695

RESUMO

BACKGROUND: Valve-in-valve transcatheter aortic valve implantation (TAVI) has emerged as a treatment for aortic bioprosthesis failure in case of prohibitive risk for redo surgery. However, clinical evaluation of valve-in-valve TAVI remains limited by the number of patients analysed. AIM: To evaluate outcomes of valve-in-valve TAVI compared with native aortic valve TAVI at a nationwide level in France. METHODS: Based on the French administrative hospital discharge database, the study collected information for all consecutive patients treated with TAVI for aortic stenosis or with isolated valve-in-valve TAVI for aortic bioprosthesis failure between 2010 and 2019. Propensity score matching was used for the analysis of outcomes. RESULTS: A total of 44,218 patients were found in the database. After matching on baseline characteristics, 2749 patients were analysed in each arm. At 30 days, no significant differences were observed regarding the occurrence of major clinical events (composite of cardiovascular mortality, all-cause stroke, myocardial infarction, major or life-threatening bleeding and conversion to open heart surgery) (odds ratio [OR] 0.83, 95% confidence interval [CI] 0.68-1.01; P=0.32). During follow-up (mean 516 days), the combined endpoint of cardiovascular death, all-cause stroke or rehospitalization for heart failure was not different between the valve-in-valve TAVI and native TAVI groups (RR 1.03, 95% CI 0.94-1.13; P=1.00). CONCLUSION: We observed that valve-in-valve TAVI was associated with good short- and long-term outcomes. No significant differences were observed compared with native valve TAVI regarding clinical follow-up.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bases de Dados Factuais , Feminino , França , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estudos Longitudinais , Masculino , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA