Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Opt Lett ; 41(8): 1841-4, 2016 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-27082359

RESUMO

We show how the same setup and procedure, exploiting spatially multimode quantum correlations, allows the absolute calibration of an electron-multiplying charge-coupled (EMCCD) camera from the analog regime down to the single-photon-counting level, just by adjusting the brightness of the quantum source. At the single-photon level, an EMCCD can be operated as an on-off detector, where quantum efficiency depends on the discriminating threshold. We develop a simple model to explain the connection of the two different regimes demonstrating that the efficiency estimated in the analog (bright) regime allows us to accurately predict the detector behavior in the photocounting regime and vice versa. This work establishes a bridge between two regions of the optical measurements that up to now have been based on completely different standards, detectors, and measurement techniques.

2.
Phys Rev Lett ; 116(18): 180401, 2016 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-27203309

RESUMO

Weak value measurements have recently given rise to a great amount of interest in both the possibility of measurement amplification and the chance for further quantum mechanics foundations investigation. In particular, a question emerged about weak values being proof of the incompatibility between quantum mechanics and noncontextual hidden variables theories (NCHVTs). A test to provide a conclusive answer to this question was given by Pusey [Phys. Rev. Lett. 113, 200401 (2014)], where a theorem was derived showing the NCHVT incompatibility with the observation of anomalous weak values under specific conditions. In this Letter we realize this proposal, clearly pointing out the connection between weak values and the contextual nature of quantum mechanics.

3.
Phys Rev Lett ; 117(17): 170402, 2016 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-27824450

RESUMO

One of the most intriguing aspects of quantum mechanics is the impossibility of measuring at the same time observables corresponding to noncommuting operators, because of quantum uncertainty. This impossibility can be partially relaxed when considering joint or sequential weak value evaluation. Indeed, weak value measurements have been a real breakthrough in the quantum measurement framework that is of the utmost interest from both a fundamental and an applicative point of view. In this Letter, we show how we realized for the first time a sequential weak value evaluation of two incompatible observables using a genuine single-photon experiment. These (sometimes anomalous) sequential weak values revealed the single-operator weak values, as well as the local correlation between them.

4.
Opt Lett ; 40(7): 1548-51, 2015 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25831381

RESUMO

Here we present a reconstruction of the positive operator-value measurement of a photon-number-resolving detector comprised of three 50∶50 beam-splitters in a tree configuration, terminated with four single-photon avalanche detectors. The four detectors' outputs are processed by an electronic board that discriminates detected photon number states from 0 to 4 and implements a "smart counting" routine to compensate for dead time issues at high count rates.

5.
Phys Rev Lett ; 113(14): 143602, 2014 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-25325642

RESUMO

We experimentally demonstrate quantum enhanced resolution in confocal fluorescence microscopy exploiting the nonclassical photon statistics of single nitrogen-vacancy color centers in diamond. By developing a general model of superresolution based on the direct sampling of the kth-order autocorrelation function of the photoluminescence signal, we show the possibility to resolve, in principle, arbitrarily close emitting centers.

6.
Opt Lett ; 38(16): 3099-102, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-24104659

RESUMO

In general, a pair of uncorrelated Gaussian states mixed in a beam splitter (BS) produces a correlated state at the output. However, when the inputs are identical Gaussian states the output state is equal to the input, and no correlations appear, as the interference had not taken place. On the other hand, since physical phenomena do have observable effects, and the BS is there, a question arises on how to reveal the interference between the two beams. We prove theoretically and demonstrate experimentally that this is possible if at least one of the two beams is prepared in a discordant, i.e., Gaussian correlated, state with a third beam. We also apply the same technique to reveal the erasure of polarization information. Our experiment involves thermal states and the results show that Gaussian discordant states, even when they show a positive Glauber P-function, may be useful to achieve specific tasks.

7.
Phys Rev Lett ; 110(15): 153603, 2013 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-25167266

RESUMO

We present the first experimental realization of the quantum illumination protocol proposed by Lloyd [Science 321, 1463 (2008)] and S. Tan et al. [Phys. Rev. Lett. 101, 253601 (2008)], achieved in a simple feasible experimental scheme based on photon-number correlations. A main achievement of our result is the demonstration of a strong robustness of the quantum protocol to noise and losses that challenges some widespread wisdom about quantum technologies.

8.
Phys Rev Lett ; 108(25): 253601, 2012 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-23004600

RESUMO

A quantum measurement can be described by a set of matrices, one for each possible outcome, which represents the positive operator-valued measure (POVM) of the sensor. Efficient protocols of POVM extraction for arbitrary sensors are required. We present the first experimental POVM reconstruction that takes explicit advantage of a quantum resource, i.e., nonclassical correlations with an ancillary state. A POVM of a photon-number-resolving detector is reconstructed by using strong quantum correlations of twin beams generated by parametric down-conversion. Our reconstruction method is more statistically robust than POVM reconstruction methods that use classical input states.

9.
Opt Express ; 19(2): 1484-92, 2011 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-21263690

RESUMO

We present a heralded single-photon source with a much lower level of unwanted background photons in the output channel by using the herald photon to control a shutter in the heralded channel. The shutter is implemented using a simple field programable gate array controlled optical switch.


Assuntos
Iluminação/instrumentação , Dispositivos Ópticos , Processamento de Sinais Assistido por Computador/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Fótons
10.
Opt Express ; 19(23): 23249-57, 2011 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-22109203

RESUMO

Well characterized photon number resolving detectors are a requirement for many applications ranging from quantum information and quantum metrology to the foundations of quantum mechanics. This prompts the necessity for reliable calibration techniques at the single photon level. In this paper we propose an innovative absolute calibration technique for photon number resolving detectors, using a pulsed heralded photon source based on parametric down conversion. The technique, being absolute, does not require reference standards and is independent upon the performances of the heralding detector. The method provides the results of quantum efficiency for the heralded detector as a function of detected photon numbers. Furthermore, we prove its validity by performing the calibration of a Transition Edge Sensor based detector, a real photon number resolving detector that has recently demonstrated its effectiveness in various quantum information protocols.

11.
Opt Express ; 18(12): 12915-22, 2010 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-20588421

RESUMO

We test two-dimensional TPSA of biphoton light emitted via ultrafast spontaneous parametric down-conversion (SPDC) using the effect of group-velocity dispersion in optical fibres. Further, we apply this technique to demonstrate the engineering of biphoton spectral properties by acting on the pump pulse shape.

12.
Phys Rev Lett ; 105(1): 010404, 2010 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-20867427

RESUMO

A novel operational method for estimating the efficiency of quantum state tomography protocols is suggested. It is based on a priori estimation of the quality of an arbitrary protocol by means of universal asymptotic fidelity distribution and condition number, which takes minimal value for better protocol. We prove the adequacy of the method both with numerical modeling and through the experimental realization of several practically important protocols of quantum state tomography.

13.
Phys Rev Lett ; 103(19): 193602, 2009 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-20365922

RESUMO

We show that broadband biphoton wave packets produced via spontaneous parametric down-conversion in crystals with linearly aperiodic poling can be easily compressed in time using the effect of group-velocity dispersion in optical fibers. This result could foster important developments in quantum metrology and lithography.

14.
Opt Express ; 15(16): 10182-8, 2007 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-19547367

RESUMO

It is shown that for a phase-matched nonlinear process producing entangled states, different Bell states are generated for different mismatch values. In particular, generation of the singlet Bell state is demonstrated within the natural linewidth of collinear frequency-degenerate type-II spontaneous parametric down-conversion (SPDC) without the o-e delay compensation. The singlet state can be filtered out by spectral selection or by the time selection of the two-photon amplitude at the output of a dispersive fibre. The effect is of considerable importance for fibre quantum communication.

15.
Rev Sci Instrum ; 80(11): 116103, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19947767

RESUMO

We present an actively multiplexed photon-counting detection system at telecom wavelengths that overcomes the difficulties of photon-counting at high rates. We find that for gated detectors, the heretofore unconsidered deadtime associated with the detector gate is a critical parameter, that limits the overall scalability of the scheme to just a few detectors. We propose and implement a new scheme that overcomes this problem and restores full scalability that allows an order of magnitude improvement with systems with as few as 4 detectors. When using just two multiplexed detectors, our experimental results show a 5x improvement over a single detector and a greater than 2x improvement over multiplexed schemes that do not consider gate deadtime.

16.
Opt Lett ; 31(23): 3508-10, 2006 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-17099766

RESUMO

We demonstrate a method to reconstruct the joint photon statistics of two or more modes of radiation by using on/off photodetection performed at different quantum efficiencies. The two-mode case is discussed in detail, and experimental results are presented for the bipartite states obtained after a beam splitter fed by a single photon state or a thermal state.

17.
Phys Rev Lett ; 96(14): 143601, 2006 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-16712073

RESUMO

We present the first observation of two-photon polarization interference structure in the second-order Glauber correlation function of two-photon light generated via type-II spontaneous parametric down-conversion. In order to obtain this result, two-photon light is transmitted through an optical fiber and the coincidence distribution is analyzed by means of the start-stop method. Beyond the experimental demonstration of an interesting effect in quantum optics, these results also have considerable relevance for quantum communications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA