Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 596(7871): 221-226, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34381232

RESUMO

Research on magnetic confinement of high-temperature plasmas has the ultimate goal of harnessing nuclear fusion for the production of electricity. Although the tokamak1 is the leading toroidal magnetic-confinement concept, it is not without shortcomings and the fusion community has therefore also pursued alternative concepts such as the stellarator. Unlike axisymmetric tokamaks, stellarators possess a three-dimensional (3D) magnetic field geometry. The availability of this additional dimension opens up an extensive configuration space for computational optimization of both the field geometry itself and the current-carrying coils that produce it. Such an optimization was undertaken in designing Wendelstein 7-X (W7-X)2, a large helical-axis advanced stellarator (HELIAS), which began operation in 2015 at Greifswald, Germany. A major drawback of 3D magnetic field geometry, however, is that it introduces a strong temperature dependence into the stellarator's non-turbulent 'neoclassical' energy transport. Indeed, such energy losses will become prohibitive in high-temperature reactor plasmas unless a strong reduction of the geometrical factor associated with this transport can be achieved; such a reduction was therefore a principal goal of the design of W7-X. In spite of the modest heating power currently available, W7-X has already been able to achieve high-temperature plasma conditions during its 2017 and 2018 experimental campaigns, producing record values of the fusion triple product for such stellarator plasmas3,4. The triple product of plasma density, ion temperature and energy confinement time is used in fusion research as a figure of merit, as it must attain a certain threshold value before net-energy-producing operation of a reactor becomes possible1,5. Here we demonstrate that such record values provide evidence for reduced neoclassical energy transport in W7-X, as the plasma profiles that produced these results could not have been obtained in stellarators lacking a comparably high level of neoclassical optimization.

3.
Phys Rev Lett ; 127(22): 225001, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34889640

RESUMO

We assess the magnetic field configuration in modern fusion devices by comparing experiments with the same heating power, between a stellarator and a heliotron. The key role of turbulence is evident in the optimized stellarator, while neoclassical processes largely determine the transport in the heliotron device. Gyrokinetic simulations elucidate the underlying mechanisms promoting stronger ion scale turbulence in the stellarator. Similar plasma performances in these experiments suggests that neoclassical and turbulent transport should both be optimized in next step reactor designs.

4.
Phys Rev Lett ; 123(2): 025002, 2019 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-31386539

RESUMO

For the first time, the optimized stellarator Wendelstein 7-X has operated with an island divertor. An operation regime in hydrogen was found in which the total plasma radiation approached the absorbed heating power without noticeable loss of stored energy. The divertor thermography recorded simultaneously a strong reduction of the heat load on all divertor targets, indicating almost complete power detachment. This operation regime was stably sustained over several energy confinement times until the preprogrammed end of the discharge. The plasma radiation is mainly due to oxygen and is located at the plasma edge. This plasma scenario is reproducible and robust at various heating powers, plasma densities, and gas fueling locations. These experimental results show that the island divertor concept actually works and displays good power dissipation potential, producing a promising exhaust concept for the stellarator reactor line.

5.
Rev Sci Instrum ; 95(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38391285

RESUMO

A synthetic Mirnov diagnostic has been developed to investigate the capabilities and limitations of an arrangement of Mirnov coils in terms of a mode analysis. Eight test cases have been developed, with different coil arrangements and magnetic field configurations. Three of those cases are experimental configurations of the stellarator Wendelstein 7-X. It is observed that, for a high triangularity of the flux surfaces, the arrangement of the coils plays a significant role in the exact determination of the poloidal mode number. For the mode analysis, torus and magnetic coordinates have been used. In most cases, the reconstruction of the poloidal mode number of a prescribed mode was found to be more accurate in magnetic coordinates. As an application, the signal of an Alfvén eigenmode, which has been calculated with a three-dimensional magnetohydrodynamics code, is compared to experimental observations at Wendelstein 7-X. For the chosen example, the calculated and measured mode spectra agree very well and additional information on the toroidal mode number and localization of the mode has been inferred.

6.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39150550

RESUMO

Larger fusion experiments require long beam paths for laser diagnostics, which requires mechanical stability and measures to deal with remaining alignment variations. At the same time, due to technical and organizational boundary conditions, calibrations become challenging. The current mid-sized experiments face the same issues, yet on a smaller scale, which makes them ideal testing environments for novel calibration methods, since a comparison with the established best practices is still possible. At the stellarator Wendelstein 7-X, the calibration and operation of the Thomson scattering diagnostic is hampered by beam displacements, coating of windows during operation, and access restrictions while the superconducting coils are active. New calibration techniques were developed to improve the profile quality and reduce calibration time. While positional variations of the laser beam have to be minimized, the remaining displacements can be accounted for during the absolute calibration. An in situ spectral calibration has been developed based on Rayleigh scattering, which calibrates the whole diagnostic, including observation windows. In addition, a less accurate but faster method has been developed, which utilizes stray-light of a tunable OPO to perform spectral calibration within minutes and does not require torus hall access. Finally, a workflow has been established to consider finite linewidths of the calibration source in the spectral calibration. While these methods will be used at W7-X to complement existing calibration techniques, they may also solve some of the aforementioned issues expected for even larger and nuclear experiments, where access restrictions are stringent and calibration becomes even more demanding.

7.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39254433

RESUMO

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the "Gas-Puff Imaging" (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system's plasma-facing components. The system features a pair of "converging-diverging" nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

8.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39292159

RESUMO

Two novel web apps for W7-X are introduced: Profile Cooker and Power House. They are designed to streamline the workflow of profile fitting and power balance analysis while offering a graphical user interface that works in any common browser. This allows us to compile a comprehensive database of experimental power balance results. All fitting functions available in Profile Cooker are presented and compared on the basis of example profiles. The power balance equation assumed in Power House is established and its individual terms are discussed. The main focus of the power balance analysis is on the turbulent transport coefficients. A model for quick calculation of neutral beam power deposition based on experimental profiles is presented. Neoclassical root transition poses an issue for power balance analysis due to the uncertainty of the radial electric field. A global, neoclassical simulation with the code EUTERPE is performed for a set of experimental profiles to gain an understanding of the neoclassical root transition.

9.
Rev Sci Instrum ; 93(2): 023506, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35232171

RESUMO

Dispersion interferometry (DI) is being employed on an increasing number of fusion experiments to measure the plasma density with a minimal sensitivity to vibrations. DIs employed in high-density experiments use phase modulation techniques up to several hundred kilohertz to enable quadrature detection and to be unaffected by variations of the signal amplitude. However, the evaluation of the temporal interferogram can be a significant source for phase errors and does not have an established processing method. There are two non-approximation-based methods currently in use: one using the ratio of amplitudes in the signal's Fourier spectrum and the other using its sectioned integration. Previously, the methods could not be used simultaneously since they differ in their respective calibration point. In this paper, we present a technique to use both phase evaluation methods simultaneously using quadrature correction methods. A comparison of their strengths and weaknesses is presented based on identical measurements indicating one to be more reliable in a more static measurement scenario, while the other excels in highly dynamic ones. Several comparative experiments are presented, which identify a significant error source in the phase measurement induced by polarization rotation. Since the same effect may be induced by Faraday rotation, the results may have direct consequence on the design of the ITER dispersion interferometer/polarimeter as well as the European DEMO's interferometer concept.

10.
Rev Sci Instrum ; 92(4): 043505, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243367

RESUMO

In nuclear fusion research, the effective ion charge Zeff, which characterizes the overall content of impurities, can be experimentally derived from the plasma electron-ion bremsstrahlung, given the electron density ne and temperature Te. At Wendelstein 7-X, a multichannel near-infrared spectrometer is installed to collect the plasma bremsstrahlung along 27 lines of sight covering more than half the plasma cross section, which provides information on Zeff over the entire plasma radius. To infer spatially resolved Zeff profiles, a Bayesian model is developed in the Minerva framework. Zeff, ne, and Te profiles are modeled as Gaussian processes, whose smoothness is determined by hyperparameters. These profiles are transformed to fields in Cartesian coordinates, given the poloidal magnetic flux surfaces calculated by the variational moments equilibrium code. Given all these physical quantities, the model predicts line-of-sight integrals of near-infrared bremsstrahlung spectra. The model includes the predictive (forward) models of the interferometer, Thomson scattering system, and visible and near-infrared spectrometers. Given the observations of all these diagnostics, the posterior probability distribution of Zeff profiles is calculated and shown as an inference solution. The smoothness (gradient) of the profiles is optimally chosen by Bayesian Occam's razor. Furthermore, wall reflections can significantly pollute the measurements of the plasma bremsstrahlung, which leads to over-estimation of Zeff values in the edge region. In the first results presented in this work, this problem does not appear, and the posterior samples of Zeff profiles are overall plausible and consistent with Zeff values inferred, given the data from the single-channel visible spectrometer.

11.
Rev Sci Instrum ; 87(11): 11D902, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910558

RESUMO

The Synthetic Aperture Microwave Imaging (SAMI) system is a novel diagnostic consisting of an array of 8 independently phased antennas. At any one time, SAMI operates at one of the 16 frequencies in the range 10-34.5 GHz. The imaging beam is steered in software post-shot to create a picture of the entire emission surface. In SAMI's active probing mode of operation, the plasma edge is illuminated with a monochromatic source and SAMI reconstructs an image of the Doppler back-scattered (DBS) signal. By assuming that density fluctuations are extended along magnetic field lines, and knowing that the strongest back-scattered signals are directed perpendicular to the density fluctuations, SAMI's 2-D DBS imaging capability can be used to measure the pitch of the edge magnetic field. In this paper, we present preliminary pitch angle measurements obtained by SAMI on the Mega Amp Spherical Tokamak (MAST) at Culham Centre for Fusion Energy and on the National Spherical Torus Experiment Upgrade at Princeton Plasma Physics Laboratory. The results demonstrate encouraging agreement between SAMI and other independent measurements.

12.
Rev Sci Instrum ; 87(11): 11E129, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910342

RESUMO

The synthetic aperture microwave imaging diagnostic has been operating on the MAST experiment since 2011. It has provided the first 2D images of B-X-O mode conversion windows and showed the feasibility of conducting 2D Doppler back-scattering experiments. The diagnostic heavily relies on field programmable gate arrays to conduct its work. Recent successes and newly gained experience with the diagnostic have led us to modify it. The enhancements will enable pitch angle profile measurements, O and X mode separation, and the continuous acquisition of 2D DBS data. The diagnostic has also been installed on the NSTX-U and is acquiring data since May 2016.

13.
Rev Sci Instrum ; 85(11): 11D861, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430274

RESUMO

A single chord two-color CO2/HeNe (10.6/0.633 µm) heterodyne laser interferometer has been designed to measure the line integral electron density along the mid-plane of the MAST Upgrade tokamak, with a typical error of 1 × 10(18) m(-3) (∼2° phase error) at 4 MHz temporal resolution. To ensure this diagnostic system can be restored from any failures without stopping MAST Upgrade operations, it has been located outside of the machine area. The final design and initial testing of this system, including details of the optics, vibration isolation, and a novel phase detection scheme are discussed in this paper.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA