RESUMO
OBJECTIVE: In cardiac surgery, colloid oncotic pressure (COP) is affected by haemodilution that results from composition and volume of prime fluid of cardiopulmonary bypass (CPB). However, the extent to which different priming strategies alter COP is largely unknown. Therefore, we investigated the effect of different priming strategies on COP in on-pump cardiac surgery. METHODS: Patients (n = 60) were divided into 3 groups (n = 20 each), based on the center in which they were operated and the specific prime fluid strategy used in that center during the inclusion period. CPB prime fluids were either gelofusine-, albumin-, or crystalloid based, the latter two with or without retrograde autologous priming. RESULTS: In all groups, COP was lowest after weaning from CPB and one hour after CPB. Between groups, COP was lowest with gelofusine prime fluid (16.4, 16.8 mmHg, respectively) compared with crystalloids (MD: -1.9; 95% CI:-3.6, -0.2; p = .02 and MD: -2.4, 95% CI: -4.2, -0.7; p = .002) and albumin (MD: -1.8, 95% CI: -3.5, -0.50; p = .041 and MD: -2.4, 95% CI: -4.1, -0.7; p = .002). In all groups, the decrease in COP one hour after bypass compared to baseline correlated positively with fluid balance at the end of surgery (p < .001). CONCLUSIONS: COP significantly decrease during CPB surgery with the largest decrease in COP at the end of surgery, while at the same time fluid balance increases. We suggest that prime fluid strategy should be carefully selected when maintenance of COP during cardiac surgery is desirable.
RESUMO
OBJECTIVES: Colloid oncotic pressure (COP) is an important factor in cardiac surgery, owing to its role in haemodilution. The effect of cardiopulmonary bypass prime fluids on the COP is unknown. In this study, the effect of crystalloid and colloid prime fluids, with or without retrograde autologous priming (RAP), on the COP during elective cardiac surgery was evaluated. METHODS: Randomized controlled trials and prospective clinical trials comparing crystalloid and colloid priming fluids or with RAP were selected. The primary outcome was the COP; secondary outcomes were fluid balance, fluid requirements, weight gain, blood loss, platelet count and transfusion requirements. RESULTS: From 1582 records, 29 eligible studies were identified. COPs were comparable between gelofusine and hydroxyethyl starch (HES) during bypass [mean difference (MD): 0.69; 95% confidence interval (CI): -2.05, 3.43; P = 0.621], after bypass (MD: -0.11; 95% CI: -2.54, 2.32; P = 0.930) and postoperative (MD: -0.61; 95% CI: -1.60, 0.38; P = 0.228). Fluid balance was lower with HES than with crystalloids. RAP reduced transfusion requirements compared with crystalloids. Blood loss was comparable between groups. CONCLUSIONS: COPs did not differ between crystalloids and colloids. As a result of increased transcapillary fluid movement, fluid balance was lower with HES than with crystalloids. Haematocrit and transfusion requirements were comparable between groups. However, the latter was lower when RAP was applied to crystalloid priming compared with crystalloids alone. Finally, no differences in blood loss were observed between the groups.