Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Environ Res ; 216(Pt 1): 114458, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36181895

RESUMO

The composition and concentration of airborne microorganisms in hospital indoor air has been reported to contain airborne bacteria and fungi concentrations ranged 101-103 CFU/m3 in inpatients facilities which mostly exceed recommendations from the World Health Organization (WHO). In this work, a deeper knowledge of the performance of airborne microorganisms would allow improving the designs of the air-conditioning installations to restrict hospital-acquired infections (HAIs). A solution containing Escherichia coli (E. coli) as a model of airborne bacteria was nebulized using the Collison nebulizer to simulate bioaerosols in various hospital areas such as patients' rooms or bathrooms. Results showed that the bioaerosol source had a significant influence on the airborne bacteria concentrations since 4.00 102, 6.84 103 and 1.39 104 CFU mL-1 were monitored during the aerosolization for 10 min of urine, saliva and urban wastewater, respectively. These results may be explained considering the quite narrow distribution profile of drop sizes around 1.10-1.29 µm obtained for urban wastewater, with much vaster distribution profiles during the aerosolization of urine or saliva. The airborne bacteria concentration may increase up to 107 CFU mL-1 for longer sampling times and higher aerosolization pressures, causing several cell damages. The cell membrane damage index (ID) can vary from 0 to 1, depending on the genomic DNA releases from bacteria. In fact, the ID of E. coli was more than two times higher (0.33 vs. 0.72) when increasing the pressure of air flow was applied from 1 to 2 bar. Finally, the ventilation air flow also affected the distribution of bioaerosols due to its direct relationship with the relative humidity of indoor air. Specifically, the airborne bacteria concentration diminished almost below 3-logs by applying more than 10 L min-1 during the aerosolization of urine due to their inactivation by an increase in their osmotic pressure.


Assuntos
Microbiologia do Ar , Poluição do Ar em Ambientes Fechados , Humanos , Poluição do Ar em Ambientes Fechados/análise , Águas Residuárias , Escherichia coli , Bactérias/genética , Fungos , Aerossóis/análise , Hospitais , Monitoramento Ambiental
2.
J Environ Manage ; 345: 118798, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37591101

RESUMO

Pathogenic microorganisms are a major concern in indoor environments, particularly in sensitive facilities such as hospitals, due to their potential to cause nosocomial infections. This study evaluates the concentration of airborne bacteria and fungi in the University Hospital Complex of Albacete (Spain), comparing the results with recent literature. Staphylococcus is identified as the most prevalent bacterial genus with a percentage distribution of 35%, while Aspergillus represents the dominant fungal genus at 34%. The lack of high Technology Readiness Levels (TRL 6, TRL 7) for effective indoor air purification requires research efforts to bridge this knowledge gap. A screening of disinfection technologies for pathogenic airborne microorganisms such as bacteria and fungi is conducted. The integration of filtration, irradiation or and (electro)chemical gas treatment systems in duct flows is discussed to enhance the design of the air-conditioning systems for indoor air purification. Concerns over microbial growth have led to recent studies on coating commercial fibrous air filters with antimicrobial particles (silver nanoparticles, iron oxide nanowires) and polymeric materials (polyaniline, polyvinylidene fluoride). Promising alternatives to traditional short-wave UV-C energy for disinfection include LED and Far-UVC irradiation systems. Additionally, research explores the use of TiO2 and TiO2 doped with metals (Ag, Cu, Pt) in filters with photocatalytic properties, enabling the utilization of visible or solar light. Hybrid photocatalysis, combining TiO2 with polymers, carbon nanomaterials, or MXene nanomaterials, enhances the photocatalytic process. Chemical treatment systems such as aerosolization of biocidal agents (benzalkonium chloride, hydrogen peroxide, chlorine dioxide or ozone) with their possible combination with other technologies such as adsorption, filtration or photocatalysis, are also tested for gas disinfection. However, the limited number of studies on the use of electrochemical technology poses a challenge for further investigation into gas-phase oxidant generation, without the formation of harmful by-products, to raise its TRL for effectively inactivating airborne microorganisms in indoor environments.


Assuntos
Poluição do Ar em Ambientes Fechados , Nanopartículas Metálicas , Humanos , Prata , Raios Ultravioleta , Desinfecção/métodos , Poluição do Ar em Ambientes Fechados/prevenção & controle
3.
J Environ Manage ; 277: 111424, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33038673

RESUMO

The aim of this work is to compare three biological strategies for the in situ remediation of a 2,4-dichlorophenoxyacetic acid (2,4-D) polluted clayey soil by coupling electrokinetics (EK) and bioremediation (technology named as electrobioremediation, EBR). The first option (i) is EK-biostimulation, in which the activity of microorganisms already present in soil is enhanced by EK phenomena. The second and third options are EK-bioaugmentation, which consist of addition of microorganisms to soil through the inclusion of permeable biological barriers: (ii) using a microbial fixed biofilm reactor as biobarrier (BB1), and (iii) using a mixture of clean soil and a microbial suspension as biobarrier (BB2). Thus, three batch experiments at bench scale were conducted under a constant electric field of 1 V cm-1, and electrode polarity was periodically reversed every 12 h (2 d-1). The duration of each test was 10 days. Two additional tests using only biodegradation or only EK were performed as auxiliary reference tests. A microbial consortium acclimated to 2,4-D biodegradation was employed. Results showed that EK-biostimulation strategy offered the best pollutant removal efficiency (reaching up almost 100%) while biobarriers offered pollutant removal rates between 75 and 85%. Permeable biobarriers allowed the introduction of microorganism but caused a decrease in the electro-osmotic flow which, in turn, reduced the mobilization and contact between microorganisms and pollutants. These results can contribute to the knowledge and understanding of electrobioremediation of polluted soil and to the feasibility of delivering microorganism to the soil by using biobarriers. Despite biostimulation was found to be the best option, results show that permeable reactive biobarriers may result in a successful alternative for in-situ EK-bioaugmentation when acclimated microbial population is not already present in soil.


Assuntos
Herbicidas , Poluentes do Solo , Ácido 2,4-Diclorofenoxiacético , Biodegradação Ambiental , Solo , Microbiologia do Solo , Poluentes do Solo/análise
4.
Molecules ; 26(22)2021 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-34833906

RESUMO

The inefficiency of conventional biological processes to remove pharmaceutical compounds (PhCs) in wastewater is leading to their accumulation in aquatic environments. These compounds are characterized by high toxicity, high antibiotic activity and low biodegradability, and their presence is causing serious environmental risks. Because much of the PhCs consumed by humans are excreted in the urine, hospital effluents have been considered one of the main routes of entry of PhCs into the environment. In this work, a critical review of the technologies employed for the removal of PhCs in hospital wastewater was carried out. This review provides an overview of the current state of the developed technologies for decreasing the chemical risks associated with the presence of PhCs in hospital wastewater or urine in the last years, including conventional treatments (filtration, adsorption, or biological processes), advanced oxidation processes (AOPs) and electrochemical advanced oxidation processes (EAOPs).


Assuntos
Técnicas Eletroquímicas/métodos , Resíduos de Serviços de Saúde/prevenção & controle , Águas Residuárias/análise , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/métodos , Antibacterianos/isolamento & purificação , Antibacterianos/urina , Biodegradação Ambiental , Resíduos de Drogas/isolamento & purificação , Hospitais , Humanos , Resíduos de Serviços de Saúde/análise , Eliminação de Resíduos de Serviços de Saúde/métodos , Consórcios Microbianos/fisiologia , Oxirredução , Urina/química , Eliminação de Resíduos Líquidos/métodos
5.
J Environ Manage ; 255: 109806, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-31759201

RESUMO

Electrokinetic-assisted phytoremediation (EKPR) has been recently proposed for the removal of pesticides from polluted soils. In this work, we report the results from an EKPR experiment that was carried out in a mesocosm mock-up of 0.386 m3 using ryegrass (Lolium perenne L.) and a low permeability soil spiked with atrazine. Plants were initially grown for 35 days; then, the soil was spiked with atrazine at a dose of 2 mg kg-1 soil. A DC electrical field of 0.6 V cm-1 was applied 24 h every day, switching polarity daily. Another identical mock-up with the same experimental conditions but without plants was used for comparison purposes. The duration of the EKPR test was 19 days during which some operational parameters were registered (electric current intensity, soil pH and temperature) and soil porewater samples were taken and analysed. Plant tissues and soil samples from the different sections in which the mock-ups were divided, were also collected and analysed at the end of the experiment. 3-D profiles of soil pH, water content and atrazine residues concentration in plants and soil were obtained and discussed. The results of this experiment were compared with others previously reported by us from a similar EKPR pot test. In spite of the difficulties to get an adequate geometric and operational similarity between setups of different scale, the main output parameters of the EKPR process (electric current, specific current charge, overall atrazine removal, specific atrazine removal efficiency, root biomass:soil weight ratio) were discussed. It was shown that, although the processes carried out are essentially the same in both scales, their extent may be quite different; it highlights the limitations of small-scale experiments to predict the results at field conditions.


Assuntos
Atrazina , Poluentes do Solo , Biodegradação Ambiental , Eletrodos , Solo
6.
J Environ Manage ; 258: 110015, 2020 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-31929057

RESUMO

This work focuses on the evaluation of the electrochemical dewatering of sludge obtained in the coagulation of wastes polluted with oxyfluorfen. To do this, sludge samples were treated, aiming not only to reduce the sludge volume, but also to facilitate the degradation of oxyfluorfen contained in the cake via electrolysis with a boron-doped diamond anode. Results show that water can be effectively recovered through three sequential stages. First, a gravity-driven stage, that can recover around 60% of initial volume and where no oxyfluorfen is dragged. Then, a second stage that involves the application of pressure and which accounts for the recuperation of an additional 25% of the total volume of the water removed and in which oxyfluorfen also remained in the cake. Finally, an electrochemical stage, which involves the application of electricity with increasing electric fields (1.0, 2.0, 4.0, and 16.0 V cm-1), accounting for the recovery of the rest of water released and where an electrolytic degradation of oxyfluorfen is obtained, whose extension depends on the electrode configuration used in the electro-dewatering cell. This electrode configuration also influences the retention or loss of oxyfluorfen from the cake, being the optimum choice the placement of the cathode downstream, next to the outlet of the dewatering cell.


Assuntos
Esgotos , Eliminação de Resíduos Líquidos , Floculação , Éteres Difenil Halogenados , Água
7.
J Environ Manage ; 255: 109895, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-31770704

RESUMO

This work focuses on the partial anodic electro-oxidation of atrazine-polluted soil washing effluents (SWE) in order to reduce its toxicity and to improve its biodegradability. Concretely it has been evaluated the influence of the anodic material used. It is hypothesized that such partial oxidation step could be considered as a pre-treatment for a subsequent biological treatment. At first, atrazine was extracted from a polluted soil by means of a surfactant-aided soil-washing process. Then, four different anodic materials were studied in partial electro-oxidation pre-treatment batch experiments at different electric charges applied: Boron Doped Diamond (BDD), Carbon Felt (CF), and Mixed Metal Oxides Anodes with Iridium and Ruthenium. Atrazine, TOC, surfactant and sulphate species concentrations, as well as changes in toxicity and biodegradability, were monitored during electrochemical experiments, showing important differences in their evolution during the treatment. It was observed that BDD was the most powerful anodic material to completely degrade atrazine. The other materials achieve an atrazine degradation rate about 75%. Regarding mineralization of the organics in SWE, BDD overtakes clearly the rest of anodes tested. CF obtains good atrazine removal but low mineralization results. All the anodes tested slightly reduced the ecotoxicity of the water effluents. About the biodegradability, only the effluent obtained after the pre-treatment with BDD presented a high biodegradability. In this sense, it must be highlighted the mineralization obtained during the BDD pre-treatment was very strong. These results globally indicate that it is necessary to find a compromise between reaching efficient atrazine removal and biodegradability improvement, while also simultaneously avoiding strong mineralization. Additional efforts should be made to find the most adequate working conditions.


Assuntos
Atrazina , Poluentes Químicos da Água , Diamante , Eletrodos , Oxirredução , Solo
8.
J Environ Manage ; 225: 280-287, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30098494

RESUMO

An electrokinetic-assisted phytoremediation test using maize (Zea mays L.) was conducted in order to assess the role of the electric field on the enhancement of plant uptake and degradation of the moderate polar pesticide atrazine in spiked soils. Twelve different treatments, including two different initial atrazine soil doses (5 and 10 mg kg-1) and two different values of the electric field applied (2 and 4 V cm-1), together with the corresponding control treatments without plants and/or without electric current, were tested. The application of an electric field during a period of 4 h a day and with periodical polarity inversion (each 2 h) did not caused significant changes in soil pH; moreover, maize plants increased the buffering capacity of the soil. The application of an electric field of 2 V cm-1 led to a slight decrease on maize biomass while the accumulation of atrazine and its main metabolites in plant tissues was significantly enhanced. On the overall, the yield of atrazine removal by electrokinetic-assisted phytoremediation with maize was increased up to 36.5% with respect to the phytoremediation process without electricity. On our knowledge, this work is the first one specifically focused on the removal of organic pollutants from soils by using the combination of phytoremediation and electrokinetic remediation.


Assuntos
Biodegradação Ambiental , Eletroquímica , Poluentes do Solo , Atrazina , Solo , Zea mays
9.
J Environ Manage ; 171: 260-266, 2016 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-26846982

RESUMO

In this research, firstly, the treatment of soil spiked with oxyfluorfen was studied using a surfactant-aided soil-washing (SASW) process. After that, the electrochemical treatment of the washing liquid using boron doped diamond (BDD) anodes was performed. Results clearly demonstrate that SASW is a very efficient approach in the treatment of soil, removing the pesticide completely by using dosages below 5 g of sodium dodecyl sulfate (SDS) per Kg of soil. After that, complete mineralization of organic matter (oxyflourfen, SDS and by-products) was attained (100% of total organic carbon and chemical oxygen demand removals) when the washing liquids were electrolyzed using BDD anodes, but the removal rate depends on the size of the particles in solution. Electrolysis of soil washing fluids occurs via the reduction in size of micelles until their complete depletion. Lower concentrations of intermediates are produced (sulfate, chlorine, 4-(trifluoromethyl)-phenol and ortho-nitrophenol) during BDD-electrolyzes. Finally, it is important to indicate that, sulfate (coming from SDS) and chlorine (coming from oxyfluorfen) ions play an important role during the electrochemical organic matter removal.


Assuntos
Eletrólise/métodos , Éteres Difenil Halogenados/isolamento & purificação , Poluentes do Solo/isolamento & purificação , Solo/química , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/métodos , Análise da Demanda Biológica de Oxigênio , Boro/química , Diamante/química , Eletrodos , Oxirredução , Dodecilsulfato de Sódio/química , Tensoativos/química
10.
Artigo em Inglês | MEDLINE | ID: mdl-26488188

RESUMO

Electrokinetic processes provide the basis of a range of very interesting techniques for the remediation of polluted soils. These techniques consist of the application of a current field in the soil that develops different transport mechanisms capable of mobilizing several types of pollutants. However, the use of these techniques could generate nondesirable effects related to the geomechanical behavior of the soil, reducing the effectiveness of the processes. In the case of the remediation of polluted soils with plasticity index higher than 35, an excessive shrinkage can be observed in remediation test. For this reason, the continued evaporation that takes place in the sample top can lead to the development of cracks, distorting the electrokinetic transport regime, and consequently, the development of the operation. On the other hand, when analyzing silty soils, in the surroundings of injection surfactant wells, high seepages can be generated that give rise to the development of piping processes. In this article methods are described to allow a reduction, or to even eliminate, both problems.


Assuntos
Recuperação e Remediação Ambiental/métodos , Substâncias Perigosas/química , Substâncias Perigosas/metabolismo , Poluentes do Solo/análise , Poluentes do Solo/metabolismo , Solo/química , Tensoativos/química , Monitoramento Ambiental , Cinética , Permeabilidade , Espanha
11.
Ind Eng Chem Res ; 63(13): 5488-5498, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38586214

RESUMO

Boron-doped diamond (BDD) electrodes are the most effective and resistant electrodic materials to perform advanced oxidation processes. Having a reactor that can provide adequate hydrodynamic conditions is mandatory to use these electrodes effectively. In this work, the diamond anode electrochemical reactor (E3L-DAER) is designed to fulfill this necessity. Several features are included to improve its efficiency, like conic inlet/outlet, flow enhancers, and a reduced interelectrode gap. The fluid dynamic validation has been performed using computer fluid dynamics (CFD) calculations, residence time distribution (RDT) curves, and mass transfer analysis. The reactor has been made using a three-dimensional (3D) printing stereolithography (SLA) technique, which allows us to build chemical-resistant reactors with nonstandard and tailored features in a cheap and fast way. The obtained results demonstrate that the designed reactor has the required fluid dynamics properties to perform reliable BDD electrode studies and applications. Finally, a BDD electrode was used to test the production of different oxidants such as persulfate, peroxophosphate, and chlorine-derived species.

12.
J Environ Manage ; 116: 181-5, 2013 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23313862

RESUMO

This work is focused on the study of the electrodeposition stage of a combined polymer-supported ultrafiltration (PSU)-electrodeposition process for the recovery and selective separation of Cu/Zn mixtures. With this aim, the electrodeposition of Cu/Zn mixtures was evaluated in the presence of ethoxylated polyethylenimine, a polymer that has exhibited good performance in PSU processes in previous studies and whose performance has been fully characterised in the literature. It was determined that at pH values equal to or less than 4, macromolecular complexes formed with both Cu and Zn are weak and electrodeposition can take place very efficiently, with the deposition of copper being strongly favoured. For values of the applied electrical charge equal or greater than 0.1 A h dm(-3), the purity of the copper deposit is greater than 99% for the range of Cu/Zn molar ratios between 1 and infinity. Next, long-term experiments in continuous mode showed that the average deposition rate was close to the maximum rate achieved when operating in discontinuous mode and that the electrodeposition process does not negatively affect the performance of the polymer in the PSU processes.


Assuntos
Cobre/química , Galvanoplastia/métodos , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/química , Zinco/química , Ultrafiltração/métodos
13.
Chemosphere ; 333: 138847, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37187374

RESUMO

In this work, it is studied the photolysis, electrolysis, and photo-electrolysis of a mixture of pharmaceutics (sulfadiazine, naproxen, diclofenac, ketoprofen and ibuprofen) contained in two very different types of real water matrices (obtained from surface and porewater reservoirs), trying to clarify the role of the matrix on the degradation of the pollutants. To do this, a new metrological approach was also developed for screening of pharmaceuticals in waters by capillary liquid chromatography mass spectrometry (CLC-MS). This allows the detection at concentrations lower than 10 ng mL-1. Results obtained in the degradation tests demonstrate that inorganic composition of the water matrix directly influences on the efficiency of the drugs removal by the different EAOPs and better degradation results were obtained for experiments carried out with surface water. The most recalcitrant drug studied was ibuprofen for all processes evaluated, while diclofenac and ketoprofen were found to be the easiest drugs for being degraded. Photo-electrolysis was found to be more efficient than photolysis and electrolysis, and the increase in the current density was found to attain a slight improvement in the removal although with an associated huge increase in the energy consumption. The main reaction pathways for each drug and technology were also proposed.


Assuntos
Cetoprofeno , Poluentes Químicos da Água , Diclofenaco/química , Cetoprofeno/análise , Ibuprofeno/análise , Água/química , Poluentes Químicos da Água/análise , Preparações Farmacêuticas
14.
Artigo em Inglês | MEDLINE | ID: mdl-22242880

RESUMO

The mobilisation of diesel-degrading microorganisms in soils of three different textures (sandy, clay and silty) using electrokinetic techniques was studied. The mobilisation tests were performed using a laboratory-scale electrokinetic cell in which a synthetic soil column was inserted between the cathode and anode compartments. Microorganisms were located at the anode compartment at the beginning of each assay. A constant cell voltage was applied, and samples were taken from the cathode and anode compartments. Microbial transport through the soil strongly depended on soil particle size. Small particle sizes (silty and clay soil) travelled at low velocities (microbial transport rates of approximately 0.06 and 0.17 cm/min, respectively), while large particle sizes (sandy soil) led to high numbers of microorganisms passing through the soil column. In sandy soil, an increase in the voltage gradient did not increase the quantity of mobilised microorganisms (approximately 10(7) CFU/mL for every voltage gradient applied). For clay and silty soils, a higher voltage gradient led to a higher quantity of microorganisms mobilised to the cathodic compartment and a lower delay time for detecting the presence of microorganisms in the same compartment.


Assuntos
Gasolina/microbiologia , Microbiologia do Solo , Poluentes do Solo/metabolismo , Biodegradação Ambiental , Eletricidade , Eletroquímica/instrumentação , Eletroquímica/métodos , Eletrodos , Concentração de Íons de Hidrogênio , Tamanho da Partícula
15.
J Hazard Mater ; 426: 128028, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-34923384

RESUMO

In this work, data obtained from the University Hospital Complex of Albacete (Spain) were selected as a case study to carry out the disinfection experiments. To do this, different configurations of electrochemical reactors were tested for the disinfection of complex urines. Results showed that 4-6 logs bacterial removal were achieved for every bacterium tested when working with a microfluidic flow-through reactor after 180 min (0.423 Ah dm-3). The MIKROZON® cell reached a total disinfection after 60 min (1.212 Ah dm-3), causing severe damages induced in the cell walls observed in SEM images. The concentration profiles of the electrogenerated disinfectants in solution could explain the differences observed. Additionally, a mean decrease in the ARGs concentration ranked as follows: blaKPC (4.18-logs) > blaTEM (3.96-logs) > ermB (3.23-logs) using the MIKROZON® cell. This electro-ozonizer could be considered as a suitable alternative to reduce the risk of antibiotic resistance spread. Hence, this study provides an insight into different electrochemical reactors for the disinfection of complex hospital urine matrices and contributes to reduce the spread of antibiotic resistance through the elimination of ARGs. A topic of great importance nowadays that needs to be further studied.


Assuntos
Antibacterianos , Desinfecção , Antibacterianos/farmacologia , Bactérias/genética , Resistência Microbiana a Medicamentos/genética , Genes Bacterianos , Humanos , Águas Residuárias
16.
Artigo em Inglês | MEDLINE | ID: mdl-21714632

RESUMO

This work studied the mobilisation of diesel-degrading microorganisms in soils of different textures using electrokinetic techniques. The mobilisation tests were performed using a laboratory-scale electrokinetic cell in which a synthetic soil column was inserted between the cathode and anode compartments. Model soils of different textures were prepared by mixing silica and kaolin at different weight ratios. Microorganisms were obtained from an undefined diesel-degrading microbial culture and located at the anode compartment. In each four hours experiment, constant cell voltage was applied, and samples were taken from the cathode compartment. Changes in the pH due to water electrolysis were found to significantly influence the process performance, and the effect of the carbonate concentration (buffer) was studied to clarify this effect. With respect to soil texture, it was observed that large particle size led to high numbers of microorganisms passing through the soil column, and the presence of small particles, which give rise to small pores, was required to improve the retention of microorganisms. Finally, current-intensity measurements with different soil textures revealed that it was favourable to use only large or small particles, whereas a sandy clay soil (50% silica/50% clay) did not favour any of the fundamental electrokinetic processes.


Assuntos
Gasolina/microbiologia , Microbiologia do Solo , Solo/química , Biodegradação Ambiental , Contagem de Colônia Microbiana , Concentração de Íons de Hidrogênio , Cinética , Tamanho da Partícula , Espanha
17.
Artigo em Inglês | MEDLINE | ID: mdl-22029697

RESUMO

In recent years, electrokinetic techniques on a laboratory scale have been studied but few applications have been assessed at full-scale. In this work, a mock-up plant with two rows of three electrodes positioned in semipermeable electrolyte wells has been used to study the electro-osmotic flux distribution. Water accumulated in the cathodic wells when an electric voltage gradient was applied between the two electrode-well rows. Likewise, slight differences in the water flux were observed depending on the position and number of electrodes used and on the voltage gradient applied. Results show that the electro-osmotic flow did not increase proportionally with the number of electrodes used. During the start-up of the study, there was an abrupt change in the current density, pH and conductivity of the soil portions closest to electrodic wells due to electrokinetic processes. These differences can be explained in terms of the complex current distributions from anode and cathode rows.


Assuntos
Técnicas Eletroquímicas/métodos , Recuperação e Remediação Ambiental/métodos , Água Subterrânea/química , Osmose , Poluentes do Solo/química , Poluentes Químicos da Água/química , Condutividade Elétrica , Eletrodos , Eletrólitos/química , Concentração de Íons de Hidrogênio , Caulim , Cinética
18.
PeerJ Comput Sci ; 7: e513, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34084925

RESUMO

Cloud computing has emerged as a cutting-edge technology which is widely used by both private and public institutions, since it eliminates the capital expense of buying, maintaining, and setting up both hardware and software. Clients pay for the services they use, under the so-called Service Level Agreements (SLAs), which are the contracts that establish the terms and costs of the services. In this paper, we propose the CloudCost UML profile, which allows the modeling of cloud architectures and the users' behavior when they interact with the cloud to request resources. We then investigate how to increase the profits of cloud infrastructures by using price schemes. For this purpose, we distinguish between two types of users in the SLAs: regular and high-priority users. Regular users do not require a continuous service, so they can wait to be attended to. In contrast, high-priority users require a constant and immediate service, so they pay a greater price for their services. In addition, a computer-aided design tool, called MSCC (Modeling SLAs Cost Cloud), has been implemented to support the CloudCost profile, which enables the creation of specific cloud scenarios, as well as their edition and validation. Finally, we present a complete case study to illustrate the applicability of the CloudCost profile, thus making it possible to draw conclusions about how to increase the profits of the cloud infrastructures studied by adjusting the different cloud parameters and the resource configuration.

19.
J Hazard Mater ; 410: 124548, 2021 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-33246823

RESUMO

This work focuses on the removal of antibiotic-resistant bacteria (ARB) contained in hospital urines by UV disinfection enhanced by electrochemical oxidation to overcome the limitations of both single processes in the disinfection of this type of effluents. UV disinfection, electrolysis, and photoelectrolysis of synthetic hospital urine intensified with K. pneumoniae were studied. The influence of the current density and the anode material was assessed on the disinfection performance of combined processes and the resulting synergies and/or antagonisms of coupling both technologies were also evaluated. Results show that the population of bacteria contained in hospital urine is only reduced by 3 orders of magnitude during UV disinfection. Electrolysis leads to complete disinfection of hospital urine when working at 50 A m-2 using Boron Doped Diamond (BDD) and Mixed Metal Oxides (MMO) as anodes. The coupling of electrolysis to the UV disinfection process leads to the highest disinfection rates, attaining a complete removal of ARB for all the current densities and anode materials tested. The use of MMO anodes leads to higher synergies than BDD electrodes. Results confirm that UV disinfection can be enhanced by electrolysis for the removal of ARB in urine, considering both technical and economic aspects.


Assuntos
Desinfecção , Poluentes Químicos da Água , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , Diamante , Eletrodos , Eletrólise , Oxirredução , Poluentes Químicos da Água/análise
20.
Environ Sci Pollut Res Int ; 28(19): 23657-23666, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32948947

RESUMO

This work focuses on the development of electro-absorption and photoelectro-absorption technologies to treat gases produced by a synthetic waste containing the highly volatile perchloroethylene (PCE). To do this, a packed absorption column coupled with a UV lamp and an undivided electrooxidation cell was used. Firstly, it was confirmed that the absorption in a packed column is a viable method to achieve retention of PCE into an absorbent-electrolyte liquid. It was observed that PCE does not only absorb but it was also transformed into phosgene and other by-products. Later, it was confirmed that the electro-absorption process influenced the PCE degradation, favoring the transformation of phosgene into final products. Opposite to what is expected, carbon dioxide is not the main product obtained, but carbon tetrachloride and trichloroacetic acid. Both species are also hazardous but their higher solubility in water opens possibilities for a successful and more environmental-friendly removal. The coupling with UV-irradiation has a negative impact on the degradation of phosgene. Finally, a reaction mechanism was proposed for the degradation of PCE based on the experimental observations. Results were not as expected during the planning of the experimental work but it is important to take in mind that PCE decomposition occurs in wet conditions, regardless of the applied technology, and this work is a first approach to try to solve the treatment problems associated to PCE gaseous waste flows in a realistic way.


Assuntos
Tetracloroetileno , Tetracloreto de Carbono , Gases , Tetracloroetileno/análise , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA