Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Front Cardiovasc Med ; 8: 719405, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34513958

RESUMO

Background: Failure of the native aortic valve and degenerative anatomy of ascending aorta in patients with previous Tirone-David operation may represent a clinical challenge, because sometimes the risk of reoperation is prohibitive. Case: We described the case of a patient suffering from severe aortic valve regurgitation and pseudoaneurysm of the aortic arch, 6 years after cardiac surgery operation. The aim of this clinical case was to assess if the complex anatomy of aortic pseudoaneurysm and aortic root geometry can be accurately reproduced from contrast-enhanced computed tomography scan into a three-dimensional (3D) printed model. Based on this procedural method, with the aid of transesophageal 3D ultrasound, we efficaciously treated the patient percutaneously with a combination of transcatheter occluder device plus microcoil embolization and transfemoral aortic valve implantation. The patient was free from complications and the need to redo cardiac surgery. Conclusion: To the best of our knowledge, this is the first description of two simultaneous complications and their staged treatment in a patient with previous aortic valve-sparing operation. This is a useful report in a single 3D model applying such specific technology to these two simultaneous clinical settings.

2.
Artigo em Inglês | MEDLINE | ID: mdl-34281108

RESUMO

Wearable devices (WDs) can objectively assess patient-reported outcomes (PROMs) in clinical trials. In this study, the feasibility and acceptability of using commercial WDs in elderly patients undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) will be explored. This is a prospective observational study. Participants were trained to use a WD and a smartphone to collect data on their physical activity, rest heart rate and number of hours of sleep. Validated questionnaires were also used to evaluate these outcomes. A technology acceptance questionnaire was used at the end of the follow up. In our participants an overall good compliance in wearing the device (75.1% vs. 79.8%, SAVR vs. TAVR) was assessed. Half of the patients were willing to continue using the device. Perceived ease of use is one of the domains that scored higher in the technology acceptance questionnaire. In this study we observed that the use of a WD is accepted in our frail population for an extended period. Even though commercial WDs are not tailored for clinical research, they can produce useful information on patient behavior, especially when coordinated with intervention tailored to the single patient.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Dispositivos Eletrônicos Vestíveis , Idoso , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Humanos , Medidas de Resultados Relatados pelo Paciente , Fatores de Risco , Resultado do Tratamento
3.
Int J Cardiol ; 168(6): 5323-8, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24007969

RESUMO

BACKGROUND: Coronary bifurcation lesions represent a difficult problem regularly confronting interventional cardiologist, in part due to the lack of dedicated device. OBJECTIVE: To investigate the feasibility, safety and effectiveness of the Tryton Side Branch Stent (Tryton Medical, Durham, NC, USA), a dedicated bare metal stent deployed in conjunction with a standard drug-eluting stent to treat bifurcation lesions. METHODS: The SAFE-TRY is a prospective single arm multicenter registry including patients with de novo bifurcation lesions in native coronary arteries and syntax score <32. The primary endpoint was target vessel failure (TVF) at 30 days that comprised cardiac death, target vessel myocardial infarction and clinically driven target vessel revascularization. Secondary endpoints included device, angiographic and procedural success, 9-month major adverse cardiac and cerebrovascular event (MACCE), and stent thrombosis (ST) rates (ClinicalTrials.gov identifier: NCT01174433). RESULTS: Among 252 enrolled patients, 24% had diabetes and 35.3% unstable angina. True bifurcation lesions involving both branches occurred in 96.8% of cases with Medina classification 1.1.1 in 62%. The left anterior descending artery and the left main were treated in 70% and 8.3% of the patients, respectively. A 6 Fr guide catheter was used in 61% of the cases. Device, angiographic and procedural success rates were 99.6%, 99.6% and 97.2% respectively. The 30-day TVF was 2.8%; the 9-month MACCE rate was 13.7%, with target lesion revascularization being 4.4%. No definite ST occurred. CONCLUSIONS: This prospective, multicenter study confirmed the feasibility, safety and effectiveness of the Tryton Side Branch Stent to treat patients with de novo complex bifurcation lesions.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/efeitos adversos , Stents/efeitos adversos , Idoso , Angioplastia Coronária com Balão/estatística & dados numéricos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Reestenose Coronária/epidemiologia , Trombose Coronária/epidemiologia , Vasos Coronários/patologia , Stents Farmacológicos/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Stents/estatística & dados numéricos , Resultado do Tratamento
4.
JACC Cardiovasc Interv ; 6(10): 1012-22, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24055444

RESUMO

OBJECTIVES: This study sought to investigate the efficacy and performance of the XIENCE V everolimus-eluting stent (EES) (Abbott Vascular, Santa Clara, California) in the treatment of de novo coronary lesions in patients with 2- to 3-vessel multivessel coronary artery disease (MV-CAD). BACKGROUND: Drug-eluting stents (DES) have emerged as an alternative to conventional coronary artery bypass surgery in patients with MV-CAD although first-generation DES yielded inferior efficacy and safety compared with surgery. METHODS: Prospective, randomized (1:1), multicenter feasibility trial was designed to assess angiographic efficacy of EES compared with the TAXUS paclitaxel-eluting stent (PES) in 200 patients, and a prospective, open-label, single-arm, controlled registry was designed to analyze the clinical outcome of EES at 1-year follow-up in 400 MV-CAD patients. For the randomized trial, the primary endpoint was in-stent late loss at 9 months. For the registry, the primary endpoint was a composite of all-cause death, myocardial infarction, and ischemia-driven target vessel revascularization at 12 months. RESULTS: The primary endpoint per single lesion was significantly lower in the EES group compared with the PES group (-0.03 ± 0.49 mm vs. 0.23 ± 0.51 mm, p = 0.001). Similar results were observed when analyzing all lesions (0.05 ± 0.51 mm vs. 0.24 ± 0.50 mm, p < 0.001). Clinical outcome at 1 year yielded a composite of major adverse cardiac events of 9.2% in the single-arm registry, and 11.1% and 16.5% in the EES and PES randomized groups, respectively (p = 0.30). CONCLUSIONS: The EXECUTIVE trial was a randomized pilot trial dedicated to the comparison of the efficacy of 2 different DES among patients with 2- to 3-vessel MV-CAD. The study shows lower in-stent late loss at 9 months with the EES XIENCE V compared with the PES TAXUS Libertè, and a low major adverse cardiac event rate at 1 year in patients with 2-to 3-vessel MV-CAD. (EXECUTIVE [EXecutive RCT: Evaluating XIENCE V in a Multi Vessel Disease]; NCT00531011).


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Everolimo , Estudos de Viabilidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
5.
J Invasive Cardiol ; 20(11): E316-9, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18987409

RESUMO

Percutaneous coronary intervention (PCI) is routinely performed in patients with non-ST elevation acute coronary syndromes after pretreatment with clopidogrel and periprocedural administration of unfractionated heparin on a weight-adjusted basis. Although activated clotting time (ACT) monitoring is encouraged to verify the adequacy of anticoagulation during the procedures, this is not a common practice in many laboratories. The authors describe 4 cases of patients with bifurcation lesions involving the left anterior descending coronary artery, who developed periprocedural thrombosis with acute transmural ischemia. All patients had inadequate ACT measurements, despite conventional heparin dosage and ongoing clopidogrel treatment. In order to achieve complete anticoagulation, patients were switched to bivalirudin, which determined a prompt effect on measured ACT. This therapeutic regimen, coupled with further intervention, allowed resolution of the thrombotic complication without bleeding. This report suggests the feasibility of a strategy of bivalirudin use in patients who have some degree of heparin 'resistance' in the setting of complicated PCI.


Assuntos
Síndrome Coronariana Aguda/terapia , Angioplastia Coronária com Balão/efeitos adversos , Anticoagulantes/administração & dosagem , Trombose Coronária/tratamento farmacológico , Hirudinas/administração & dosagem , Fragmentos de Peptídeos/administração & dosagem , Idoso , Trombose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Proteínas Recombinantes/administração & dosagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA