Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 100(2): 190-198, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35686523

RESUMO

AIM: The impact of Grade III coronary perforations (G3-CP) in the setting of CTO-PCI is not well assessed. METHODS AND RESULTS: We reviewed 7773 CTO-PCI and 98,819 non CTO-PCI performed in 10 European centers: G3 perforation occurred in 87 patients (1.1%) during CTO PCI and 224 patients (0.22%) during non CTO-PCI (p < 0.001). G3-CP involved the CTO segment in 68% of patients and the retrograde channels in 14% of cases. In the CTO PCI group, wire induced G3-CP (50.5% vs. 32.5%, p = 0.02) occurred predominantly when dedicated CTO tapered and highly penetrative wires were used. Intra-procedural and in-hospital death rates were 4.6% vs. 5.8% and 3.6% vs. 7.5% respectively for CTO PCI and non-CTO PCI groups (p = NS). At a median follow up of 24 months, the overall mortality and MAE were respectively 7.8% and MAE 19% without difference among groups. CONCLUSIONS: We showed similar in-hospital and long-term outcomes when G3 perforations occurred during CTO PCI and non CTO-PCI.


Assuntos
Doença da Artéria Coronariana , Oclusão Coronária , Traumatismos Cardíacos , Intervenção Coronária Percutânea , Lesões do Sistema Vascular , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/terapia , Mortalidade Hospitalar , Humanos , Sistema de Registros , Fatores de Risco , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/terapia
2.
Eur Heart J Suppl ; 23(Suppl E): E177-E183, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34650381

RESUMO

Renal denervation (RDN) is a therapeutic strategy for patients with uncontrolled arterial hypertension characterized by considerable fluctuations during its progression. After initial strong enthusiasm, the procedure came to an abrupt halt following the publication of the Symplicity HTN-3 study results. The results of recently published studies highlight the reduction in blood pressure values after RDN and justify the inclusion in the Guidelines of new recommendations for the use of RDN in clinical practice, in selected patients. Additionally, RDN findings are summarized in view of other potential indications such as atrial fibrillation. Six prospective, randomized studies are presented that evaluated RDN as an adjunct therapy to pulmonary vein isolation for the treatment of atrial fibrillation. In five studies, patients had uncontrolled hypertension despite therapy with three antihypertensive drugs. The analysis of these studies showed that RDN reduced the recurrence of atrial fibrillation (AF) by 57% compared to patients with pulmonary vein isolation (PVI) only. Modulation of the autonomic nervous system by RDN has been shown not only to reduce blood pressure but also to have an antiarrhythmic effect in symptomatic AF patients when the strategy is combined with PVI, thus opening up new therapeutic scenarios.

3.
Eur Heart J Suppl ; 22(Suppl L): L160-L165, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33239993

RESUMO

Initial studies on renal denervation (RDN) for the treatment of non-controlled arterial hypertension (HTN) through radiofrequency ablation of renal arteries demonstrated that RDN is an effective therapeutic strategy to reduce arterial blood pressure (BP). Nonetheless, the first randomized study, SYMPLICITY-HTN-3, failed to demonstrate a clear benefit for RND over the control group. Technologic evolution, with the introduction of new second generation multi-electrode devices, allowed deep energy delivery along the full circumference of the vessel. Two recent randomized studies involving patients assuming (SPYRAL HTN-ON MED) or not (SPYRAL HTN-OFF MED) antihypertensive pharmacologic treatment, demonstrated the efficacy and safety of RDN using second generation systems for radiofrequency ablation. Another recent randomized study demonstrated that RDN with ultrasounds (RADIANCE-HTN SOLO) of the main renal arteries led to a significant BP reduction compared to the control group. These studies have once again raised the interest of the scientific community towards attempting to define the appropriate role of RDN in the treatment of hypertension. Nonetheless, larger and longer clinical trials will be necessary to draw further conclusions.

4.
Catheter Cardiovasc Interv ; 93(6): E346-E348, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30286525

RESUMO

Cerebral ischemic lesions occurring during transcatheter valve interventions are common feared complications and the use of filter device seems to reduce their incidence. We report the case of an 84-year old female patient with severe mitral regurgitation undergoing MitraClip. During the trans-esophageal echocardiography (TEE)-guided procedure was detected the presence of a little fibrin strand adherent to the steerable guide catheter for which we decided to implant the Claret CE Pro (Claret Medical, Inc. Santa Rosa, CA, USA) cerebral protection device and to continue the procedure during which the thrombus disappeared. At the end of the procedure a big thrombus was detected in the distal filter. The histologic analysis of the debris captured by the filters showed the presence of a thrombus, compatible with the image identified by TEE.


Assuntos
Cateterismo Cardíaco/instrumentação , Dispositivos de Proteção Embólica , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Embolia Intracraniana/prevenção & controle , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Tromboembolia/prevenção & controle , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Embolia Intracraniana/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Tromboembolia/etiologia , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 92(7): 1247-1255, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30244520

RESUMO

BACKGROUND: Covered stent (CS) implantation is considered a useful device in the setting of Grade III Coronary Perforation (G3CP), one of the most harmful PCI complication. However, data regarding efficacy of this device and clinical outcomes are still limited. METHODS AND RESULTS: From 1993 to 2015, among 97,779 patients from 9 European centres undergoing PCI, 224 patients had G3CP (0.23%), and 102 patients were managed with CS implantation (96 with PTFE, 6 with pericardium). Device oriented composite endpoint (DOCE), a composite of cardiac death, target lesion revascularization, and stent thrombosis (ST) in-hospital and at long term follow-up were evaluated. G3-CP perforations were successfully sealed with CS in 88 patients (86.3%) with need of intraprocedural pericardiocentesis in one-third of cases. Protamine as heparin reversal agent was administered in 36 (35%) of cases. The cumulative incidence of in-hospital DOCE were 16.6% (17/102): death 14.7%, TLR 2.9%, ST 3.9%. At long-term follow-up (mean 42 ± 38 months), DOCE rates occurred in 19.7%: death 7.4%, TLR 11%, and ST 6.2%. Indication to Dual Antiplatelet Therapy (DAPT) was lifelong in 20% of cases, 1 to 6 months in 22.5% and 12-months in 57.5% without differences in long-term DOCE before and after DAPT interruption (8.0 vs. 6.6%, respectively, P = 0.20). CONCLUSIONS: Use of CS was successful in sealing grade 3 coronary artery perforations in the majority of cases. Beside the high rate of clinical events at short and long-term, ST remains the leading cause of device failure.


Assuntos
Vasos Coronários/lesões , Traumatismos Cardíacos/terapia , Intervenção Coronária Percutânea/instrumentação , Pericárdio/transplante , Politetrafluoretileno , Stents , Lesões do Sistema Vascular/terapia , Idoso , Idoso de 80 Anos ou mais , Vasos Coronários/diagnóstico por imagem , Europa (Continente) , Feminino , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/mortalidade
6.
Catheter Cardiovasc Interv ; 91(5): 884-891, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28707375

RESUMO

BACKGROUND: Patients with diabetes mellitus (DM) remain at higher risk of restenosis after percutaneous coronary intervention despite the use of contemporary drug-eluting stents. The Cre8 amphilimus-eluting stent (AES) has shown promising results in DM patients. Whether this holds true irrespective of patient's clinical and angiographic complexity is unknown. METHODS: Five hundred and ninety five consecutive patients (738 lesions) undergoing AES implantation were included in the INVESTIG8 multicenter registry. Patients were stratified according to DM status and further stratified according to patients' complexity. The prespecified primary endpoint was target lesion failure (TLF)-defined as the composite of cardiac death, target-vessel myocardial infarction, and target lesion revascularization (TLR). RESULTS: DM patients were more often complex as compared to non-DM patients (70% vs. 61%, P = 0.015). At 18-month follow-up, there was a trend to a higher TLF rate in DM than in non-DM patients (6.9% vs. 3.5%, P = 0.063). This was largely driven by a markedly higher risk of TLF among complex DM patients as compared to simple DM patients (8.9% vs. 2.4%, P = 0.053). A multivariate analysis identified complexity (HR 6.11, 95% CI: 1.42-26.2) but not DM (HR 1.59; 95% CI 0.71-3.56) as an independent predictor of TLF. Of note, TLR rates were similar between DM and non-DM patients (3.3% vs. 1.9%, P = 0.228). CONCLUSIONS: In this real-world, multicenter registry the Cre8 AES showed favorable clinical outcomes in DM patients. Increased risk of TLF appears to be driven by patients' complexity rather than DM status. These findings will need to be confirmed in a large-scale randomized trial.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Stents Farmacológicos/efeitos adversos , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Recidiva , Sistema de Registros , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 92(1): E1-E8, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-28699188

RESUMO

OBJECTIVES: Culprit plaque characteristics in young patients who experience an Acute Coronary Syndrome (ACS) evaluated by OCT (Optical Coherence Tomography) have to be defined. The OCT-FORMIDABLE is a multicentre retrospective registry enrolling consecutive patients with ACS who performed OCT in 9 European centres. METHODS: Patients were divided in two groups according to age at presentation: juvenile-ACS (age ≤ 50 years) and not juvenile-ACS (age > 50 years). Primary end-point was the prevalence of plaque rupture (PR). Secondary end point was the prevalence of thin cap fibro atheroma (TCFA), fibrocalcific and fibrotic plaque. RESULTS: 285 patients were included, 71 (24.9%) in juvenile-ACS group and 215 (75.1%) in not juvenile-ACS group. Younger patients showed a trend for a higher prevalence of TCFA (70 vs. 58%, P = 0.06) and thrombus presence (62 vs. 51%, P = 0.1), while no statistical difference concerning PR (70 vs. 64%, P = 0.29). Of interest patients younger that 35 years showed a higher prevalence of PR compared to patients aged between 35 and 45 or 45 and 50 years (100 vs. 72 vs. 55%, P = 0.03). Culprit plaque in juvenile-ACS group showed more frequently a reduced mean cap thickness (119 ± 66 vs. 155 ± 95 nm, P = 0.05) and less frequently fibrotic (32 vs. 57%, P < 0.001) or fibrocalcific (17 vs. 36%, P = 0.003) characteristics. CONCLUSION: young patients with ACS show a trend for a higher prevalence of culprit PR, a thinner cap and less fibrotic or fibrocalcific components.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Placa Aterosclerótica , Tomografia de Coerência Óptica , Calcificação Vascular/diagnóstico por imagem , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/patologia , Adulto , Fatores Etários , Idoso , Artérias Carótidas/patologia , Doenças das Artérias Carótidas/epidemiologia , Doenças das Artérias Carótidas/patologia , Europa (Continente)/epidemiologia , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Ruptura Espontânea , Calcificação Vascular/epidemiologia , Calcificação Vascular/patologia
9.
Catheter Cardiovasc Interv ; 89(4): E112-E123, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27469063

RESUMO

OBJECTIVES: To compare the safety and efficacy of the Axxess™ biolimus-eluting stent with the second-generation drug-eluting stent (DES) in the treatment of bifurcation lesions. BACKGROUND: The Axxess™ is a dedicated bifurcation stent, designed to cover the lesion at the carina level. METHODS: Between April 2012 and August 2014, 165 patients with de novo bifurcation lesions were treated with the Axxess™ stent (Axxess group). A propensity-score matched group of 165 patients treated with DES in the same period was selected (Control group). The primary objectives were (1) the procedural complication rate, including side branch (SB) occlusion and trouble in SB access after main vessel stenting; and (2) the device, the angiographic, and the procedural success rate. RESULTS: Procedural complications occurred in 1 patient (0.6%) in the Axxess group and in 20 patients (12%) in the Control group (OR = 0.03; 95% confidence interval 0.005-0.27; P < 0.001). Device success was obtained in 164 (99.5%) patients in the Axxess group and in all in the Control group (P = 1.00). Angiographic success was obtained in all patients. Inaccurate Axxess™ stent position occurred in 21 (13%) patients, and was more often associated with moderate-to-severe calcifications and distal lesion site. Procedural success was obtained in 91.5% patients in the Axxess group and in 90% patients in the Control group (P = 0.72). CONCLUSIONS: The present registry suggests that the Axxess™ stent (1) may represent a valid alternative approach for the treatment of bifurcation lesions and (2) should be avoided in moderate-to-severe calcifications and/or in distal lesions. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose Coronária/cirurgia , Vasos Coronários/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Sirolimo/análogos & derivados , Idoso , Angiografia Coronária , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Pontuação de Propensão , Estudos Prospectivos , Desenho de Prótese , Sirolimo/farmacologia , Ultrassonografia de Intervenção
13.
Circulation ; 136(6): 602-604, 2017 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-28784829
14.
Catheter Cardiovasc Interv ; 81(1): E36-43, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22517610

RESUMO

OBJECTIVES: The aim of this study is to assess the efficacy of the high-dose rosuvastatin preadministration in reducing periprocedural myocardial necrosis and major adverse cardiovascular and cerebrovascular events (MACCE) in patients undergoing elective percutaneous coronary intervention (PCI). BACKGROUND: Elective PCI may be complicated with an elevation of cardiac biomarkers. Several studies suggested that pretreatment with statins may be associated with a reduction in periprocedural myocardial necrosis. METHODS: One hundred and sixty patients with stable angina who underwent elective PCI were randomly assigned to receive either a preprocedural loading dose (40 mg) of rosuvastatin group (RG, n = 80) or a standard treatment [control group (CG), n = 80].The primary endpoint was the incidence of periprocedural myocardial necrosis. The secondary endpoint was the assessment of MACCE [cardiac death, all-myocardial infarction (MI), stroke, and target vessel revascularization (TVR)] at a 30-day and 12-month follow-up, as well as the rate of periprocedural rise of Troponin T-serum levels >3× upper limit of normal. RESULTS: Twelve and 24-hr post-PCI creatinine kinase MB isoform elevation >3× occurred more frequently in the CG than in the RG (22.7 vs. 7.1; P = 0.034 and 26.4 vs. 8.7; P = 0.003). At the 30-day and 12-month follow-up, the incidence of cumulative MACCE was higher in CG than in the RG (30.0% vs. 8.7%; P = 0.001 and 35.0% vs. 12.5%; P = 0.001).The difference between the groups was mainly due to the periprocedural MI incidence (26.4% vs. 8.7%; P = 0.003).The rate of cardiac death, spontaneous MI, TVR, and stroke were similar in the two groups. CONCLUSIONS: High loading dose of rosuvastatin within 24 hr before elective PCI seems to decrease the incidence of periprocedural myocardial necrosis during a period of 12-months compared to the standard treatment.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Estenose Coronária/terapia , Fluorbenzenos/administração & dosagem , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Infarto do Miocárdio/prevenção & controle , Pré-Medicação , Pirimidinas/administração & dosagem , Sulfonamidas/administração & dosagem , Idoso , Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Cardiotônicos/administração & dosagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Esquema de Medicação , Feminino , Seguimentos , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/patologia , Necrose/etiologia , Necrose/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Pulsoterapia , Medição de Risco , Rosuvastatina Cálcica , Taxa de Sobrevida , Resultado do Tratamento
15.
Int Heart J ; 54(4): 234-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23924937

RESUMO

Drug-eluting stents (DES) have a moderately higher incidence of stent thrombosis compared to bare metal stents (BMS) and very late DES thrombosis has been frequently described. We report a case of a 66 year-old male who experienced very late stent thrombosis at 5 years after paclitaxel-eluting stent (PES) implantation and 3 days after clopidogrel withdrawal. Intravascular ultrasound (IVUS) performed during the index procedure showed that the previously implanted PES was undersized. Since the patient could not take clopidogrel, we treated him with only a noncompliant balloon (3.0 × 15 mm) with optimal expansion as confirmed by IVUS. This case report describes a patient who continued clopidogrel treatment for 5 years and was probably protected from a procedural failure. During the current hospitalization, the patient was found to be a responder to clopidogrel after a platelet function assessment with Multiplate (Dynabyte Informationssysteme GmbH, Munich, Germany).


Assuntos
Stents Farmacológicos , Oclusão de Enxerto Vascular/etiologia , Paclitaxel/farmacologia , Ticlopidina/análogos & derivados , Suspensão de Tratamento , Idoso , Antineoplásicos Fitogênicos/farmacologia , Clopidogrel , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Inibidores da Agregação Plaquetária/administração & dosagem , Fatores de Risco , Ticlopidina/administração & dosagem , Fatores de Tempo , Ultrassonografia de Intervenção
16.
Comput Biol Med ; 154: 106547, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36696813

RESUMO

BACKGROUND: Clinical decisions about Heart Failure (HF) are frequently based on measurements of left ventricular ejection fraction (LVEF), relying mainly on echocardiography measurements for evaluating structural and functional abnormalities of heart disease. As echocardiography is not available in primary care, this means that HF cannot be detected on initial patient presentation. Instead, physicians in primary care must rely on a clinical diagnosis that can take weeks, even months of costly testing and clinical visits. As a result, the opportunity for early detection of HF is lost. METHODS AND RESULTS: The standard 12-Lead ECG provides only limited diagnostic evidence for many common heart problems. ECG findings typically show low sensitivity for structural heart abnormalities and low specificity for function abnormalities, e.g., systolic dysfunction. As a result, structural and functional heart abnormalities are typically diagnosed by echocardiography in secondary care, effectively creating a diagnostic gap between primary and secondary care. This diagnostic gap was successfully reduced by an AI solution, the Cardio-HART™ (CHART), which uses Knowledge-enhanced Neural Networks to process novel bio-signals. Cardio-HART reached higher performance in prediction of HF when compared to the best ECG-based criteria: sensitivity increased from 53.5% to 82.8%, specificity from 85.1% to 86.9%, positive predictive value from 57.1% to 70.0%, the F-score from 56.4% to 72.2%, and area under curve from 0.79 to 0.91. The sensitivity of the HF-indicated findings is doubled by the AI compared to the best rule-based ECG-findings with a similar specificity level: from 38.6% to 71%. CONCLUSION: Using an AI solution to process ECG and novel bio-signals, the CHART algorithms are able to predict structural, functional, and valve abnormalities, effectively reducing this diagnostic gap, thereby allowing for the early detection of most common heart diseases and HF in primary care.


Assuntos
Insuficiência Cardíaca , Função Ventricular Esquerda , Humanos , Volume Sistólico , Insuficiência Cardíaca/diagnóstico por imagem , Ecocardiografia , Redes Neurais de Computação
17.
Panminerva Med ; 65(4): 454-460, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37335246

RESUMO

BACKGROUND: Acute coronary syndromes (ACS) are a common cause of morbidity and mortality. Several studies have focused on ACS at admission, but limited evidence is available on sex-based comparison of patients discharged after ACS. We appraised the outlook of women and men discharged after ACS. METHODS: Details on women enrolled in the PRAISE registry, an international cohort study spanning 23,700 patients included between 2003 and 2019, were systematically collected. We focused on patient and procedural features, medications at discharge, and 1-year outcomes. The primary endpoint was the composite of death, myocardial infarction, or major bleeding after discharge. RESULTS: A total of 17,804 (76.5%) men and 5466 (23.5%) women were included. Several baseline differences were found, including risk factors and prior revascularization (all P<0.05). Men underwent more frequently radial access, and at discharge they received more commonly dual antiplatelet therapy and guideline-directed medical therapy (P<0.001). At 1-year follow-up, risks of death, reinfarction, major bleeding, and non-fatal major bleeding, jointly or individually, were all significantly higher in women (all P≤0.01). All such differences however did not hold true at multivariable analysis, with the exception of major bleeding, which appeared surprisingly less common in females at fully adjusted analysis (P=0.017). CONCLUSIONS: Women, albeit only apparently, had worse outcomes 1 year after discharge for ACS, but adjusted analysis suggested instead that they faced a lower risk of major bleeding after discharge. These findings support the call for more aggressive management of women after ACS.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Masculino , Humanos , Feminino , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Alta do Paciente , Estudos de Coortes , Hemorragia/tratamento farmacológico , Sistema de Registros , Resultado do Tratamento , Inibidores da Agregação Plaquetária/uso terapêutico
18.
J Interv Cardiol ; 25(6): 596-603, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22248370

RESUMO

BACKGROUND: Twelve-month dual antiplatelet therapy (DAT) with aspirin and clopidogrel after drug-eluting stent (DES) implantation is routinely recommended. It is unclear if prolonged (>12-month) DAT is also favorable. We compared the outcome of patients discontinuing DAT 12 months after off-label DES implantation versus those with DAT for >12 months. METHODS: Baseline, treatment, and outcome data of patients undergoing off-label DES implantation and free from events 11.5 months after index procedure were retrospectively retrieved. Those discontinuing DAT between 11.5 and 12.5 months (12-month DAT group) were compared to those discontinuing DAT after 12.5 months (>12-month DAT group). The primary end-point was the long-term (>24-month) rate of major adverse cerebro-cardiovascular events (MACCE). RESULTS: Two hundred seventy-two patients met study inclusion criteria: 133 (48.9%) in the 12-month DAT group and 139 (51.1%) in the >12-month DAT group (who were on DAT for an average of 24 months). After an average of 36 months after DES implantation, 14 patients (5.1%) developed MACCE, with 6 (3.5%) cardiac deaths, 7 (2.2%) myocardial infarctions, no stroke, and 5 (1.8%) repeat revascularizations. The >12-month DAT group had a significantly lower risk of MACCE (1 [0.7%] vs. 13 [9.8%] in the 12-month DAT group, P < 0.001) and myocardial infarction (0 vs. 7 [5.3%], P = 0.006), with such differences confirmed at multivariable propensity-adjusted analyses. No significant differences in terms of minor or major bleedings occurred. CONCLUSIONS: In this retrospective registry, patients with off-label DES implantation receiving prolonged (>12 months) DAT presented with lower rates of MACCE and myocardial infarction.


Assuntos
Stents Farmacológicos , Inibidores da Agregação Plaquetária/uso terapêutico , Aspirina/uso terapêutico , Clopidogrel , Quimioterapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica , Uso Off-Label , Sistema de Registros , Retratamento/estatística & dados numéricos , Estudos Retrospectivos , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico
19.
Eur Heart J Case Rep ; 6(6): ytac154, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35775019

RESUMO

Background: Currently, the leadless pacemaker indications are limited to few and highly selected cases. Case summary: We describe the first reported case of an atrioventricular Micra™ leadless pacemaker implantation complicated by tricuspid posterior leaflet flail with severe regurgitation in a 29-year-old man affected by asymptomatic and progressive high degree atrio-ventricular block. The patient was then treated with endoscopic tricuspid valve repair, leadless pacemaker removal and implantation of an epicardial pacemaker. Discussion: Leadless pacemaker complications are multiple, hence it is essential to ensure a safe procedure, especially in the younger patients. We thought that the application of a transesophageal echocardiography guidance might mitigate the risk of major complications.

20.
Open Heart ; 9(1)2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35190470

RESUMO

PURPOSE: In a comparator study, designed with assistance from the Food and Drug Administration, a State-of-the-Art (SOTA) ECG device augmented with automated analysis, the comparator, was compared with a breakthrough technology, Cardio-HART (CHART). METHODS: The referral decision defined by physician reading biosignal-based ECG or CHART report were compared for 550 patients, where its performance is calculated against the ground truth referral decision. The ground truth was established by cardiologist consensus based on all the available measurements and findings including echocardiography (ECHO). RESULTS: The results confirmed that CHART analysis was far more effective than ECG only analysis: CHART reduced false negative rates 15.8% and false positive (FP) rates by 5%, when compared with SOTA ECG devices. General physicians (GP's) using CHART saw their positive diagnosis rate significantly increased, from ~10% to ~26% (260% increase), and the uncertainty rate significantly decreased, from ~31% to ~1.9% (94% decrease). For cardiology, the study showed that in 98% of the cases, the CHART report was found to be a good indicator as to what kind of heart problems can be expected (the 'start-point') in the ECHO examination. CONCLUSIONS: The study revealed that GP use of CHART resulted in more accurate referrals for cardiology, resulting in fewer true negative or FP-healthy or mildly abnormal patients not in need of ECHO confirmation. The indirect benefit is the reduction in wait-times and in unnecessary and costly testing in secondary care. Moreover, when used as a start-point, CHART can shorten the echocardiograph examination time.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Ecocardiografia , Eletrocardiografia , Medicina Geral/métodos , Cardiopatias/diagnóstico , Cardiologia/métodos , Cardiologia/tendências , Tomada de Decisão Clínica , Tomada de Decisões Assistida por Computador , Sistemas de Apoio a Decisões Clínicas/instrumentação , Sistemas de Apoio a Decisões Clínicas/tendências , Ecocardiografia/instrumentação , Ecocardiografia/métodos , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Prova Pericial/métodos , Prova Pericial/estatística & dados numéricos , Humanos , Encaminhamento e Consulta/estatística & dados numéricos , Avaliação da Tecnologia Biomédica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA